Test Report

FCC ID: OXGZW30

Test Report

Download: PDF
FCCID_2587903

                 FCC RADIO TEST REPORT
                         FCC ID: OXGZW30
                          IC: 10460A-ZW30

Product Name:    Smart Switch

Trademark:       Show Home


Model Number:    ZW30


Prepared For :   Willis Electric CO.,Ltd.

Address :        No.504-1,Chung-Hua Road, Sec.4, Hsin Chu,300 Taiwan

Prepared By :    DongGuan Precise Testing Service Co.,Ltd.

                 Building D, Baoding Technology Park, Guangming Road 2, Guangming
Address :        Community, Dongcheng District, Dongguan, Guangdong, China

Test Date:       Mar. 11 - Mar. 25, 2015

Date of
                 Mar. 25, 2015
Report :

Report No.:      PTS1503058014F


                                 Page 2 of 27              Report No.: PTS1503058014F

VERIFICATION OF COMPLIANCE

Applicant:             Willis Electric CO.,Ltd.

Address                No.504-1,Chung-Hua Road, Sec.4, Hsin Chu,300 Taiwan

Manufacturer Name:     Kupoint(DongGuan)Electric Co.,Ltd

Address:               Huai De Village, HumenTown, Dong Guan, Guang Dong, China

Product Description:   Smart Switch

Brand Name:            Show Home

Model Name:            ZW30
Model difference:      N/A

Test procedure         ANSI C63.4-2014, CISPR 16-1-4:2010, RSS-Gen Issue 4,2014

Standards              FCC PART15.249, RSS-210 Issue 8,Dec 2010




                    Prepared by :

                                                                  Assistant


                    Reviewer :
                                                               Supervisor



                    Approved & Authorized Signer :


                       Page 3 of 27               Report No.: PTS1503058014F




                        Table of Contents                              Page


1 . SUMMARY OF TEST RESULTS                                              4
  1.1 TEST FACILITY                                                      5
  1.2 MEASUREMENT UNCERTAINTY                                            5
2 . GENERAL INFORMATION                                                  6
  2.1 GENERAL DESCRIPTION OF EUT                                         6
  2.2 DESCRIPTION OF TEST MODES                                          7
  2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED            8
  2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE)                       9
  2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS                                10
3 . TEST RESULT                                                         11
  3.1 ANTENNA REQUIREMENT                                               11
     3.1.1 STANDARD REQUIREMENT                                         11
     3.1.2 EUT ANTENNA                                                  11
  3.2 CONDUCTED EMISSION MEASUREMENT                                    12
     3.2.1 POWER LINE CONDUCTED EMISSION LIMITS                         12
     3.2.2 TEST PROCEDURE                                               13
     3.2.3 DEVIATION FROM TEST STANDARD                                 13
     3.2.4 TEST SETUP                                                   13
     3.2.5 TEST RESULT                                                  14
  3.3 RADIATED EMISSION MEASUREMENT                                     16
     3.3.1 RADIATED EMISSION LIMITS                                     16
     3.3.2 TEST PROCEDURE                                               17
     3.3.3 DEVIATION FROM TEST STANDARD                                 17
     3.3.4 TEST SETUP                                                   18
     3.3.5 TEST RESULTS (BLOW 30MHZ)                                    20
     3.3.6 TEST RESULTS (BETWEEN 30 – 1000 MHZ)                         21
     3.3.7 TEST RESULTS (ABOVE 1000 MHZ)                                24
4 . 20DB BANDWIDTH TEST                                                 26
     4.1 TEST PROCEDURE                                                 26
     4.2 DEVIATION FROM STANDARD                                        26
     4.3 TEST SETUP                                                     26
     4.4 TEST RESULTS                                                   27
APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS


                               Page 4 of 27              Report No.: PTS1503058014F


1. SUMMARY OF TEST RESULTS

Test procedures according to the technical standards:
                           FCC Part15, Subpart C (15.249)
                         RSS-Gen Issue 4 & RSS-210 Issue 8
        Standard
                                      Test Item            Judgment         Remark
         Section
        15.207&
                                Conducted Emission           Pass
  RSS-Gen issue 4,8.8

         15.203                Antenna Requirement           Pass

     15.249& A8.5           Radiated Spurious Emission       Pass

     15.249& A8.1                20 DB Bandwidth             Pass

     15.205& A8.5               Band Edge Emission           Pass


                               Page 5 of 27                   Report No.: PTS1503058014F


1.1 TEST FACILITY
   Dongguan Dongdian Testing Service Co., Ltd
   Add.: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan
   City, Guangdong Province, China, 523808
   FCC Registration No.: 270092; IC Registration No.: 10288A-1

1.2 MEASUREMENT UNCERTAINTY
  The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a
  standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
  approximately 95 %.

             No.      Item                                 Uncertainty
             1        Conducted Emission Test              ±1.38dB
             2        RF power,conducted                   ±0.16dB
             3        Spurious emissions,conducted         ±0.21dB
             4        All emissions,radiated(<1G)          ±4.68dB
             5        All emissions,radiated(>1G)          ±4.89dB
             6        Temperature                          ±0.5°C
             7        Humidity                             ±2%


                               Page 6 of 27                     Report No.: PTS1503058014F


2. GENERAL INFORMATION

2.1 GENERAL DESCRIPTION OF EUT



        Equipment                   Smart Switch
        Trade Name                  Show Home
        Model Name                  ZW30
        Serial Model                N/A
        Model Difference            N/A
                                    The EUT is a Smart Switch

                                    Operation Frequency:   908.42MHz
                                    Modulation Type:       FSK
                                    Channel number         1 channel
                                    Antenna Designation: Wire antenna
        Product Description         Antenna Gain(Peak)     -2.1dBi
                                    Max. QP field strength 91.21 dBuV/m@3m

                                    Based on the application, features, or specification
                                    exhibited in User's Manual, the EUT is considered as an
                                    ITE/Computing Device. More details of EUT technical
                                    specification, please refer to the User's Manual.

        Power Supply                AC 120V,60Hz
        HVIN                        ZW30
        FVIN                        F_smart switch V1
Note:
    1. For a more detailed features description, please refer to the manufacturer’s specifications
       or the User's Manual.


                              Page 7 of 27                     Report No.: PTS1503058014F


2.2 DESCRIPTION OF TEST MODES

   To investigate the maximum EMI emission characteristics generates from EUT, the test system
   was pre-scanning tested base on the consideration of following EUT operation mode or test
   configuration mode which possible have effect on EMI emission level. Each of these EUT
   operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively.

       Pretest Mode                              Description
          Mode 1                                     TX


                              For Conducted Emission

      Final Test Mode                            Description
          Mode 1                                     TX


                                For Radiated Emission

      Final Test Mode                            Description
          Mode 1                                     TX



Note: For the TX mode, the EUT is configured as the continuously transmitting mode.


                       Page 8 of 27           Report No.: PTS1503058014F


2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED




                                         AC
                           E-1
                           EUT


                                 Page 9 of 27                    Report No.: PTS1503058014F


2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE)

The EUT has been tested as an independent unit together with other necessary accessories or
support units. The following support units or accessories were used to form a representative test
configuration during the tests.

Item         Equipment             Mfr/Brand    Model/Type No.     Series No.          Note
E-1        Smart Switch          Show Home          ZW30              N/A              EUT




 Item    Shielded Type   Ferrite Core      Length                           Note




 Note:
  (1)     The support equipment was authorized by Declaration of Confirmation.
  (2)     For detachable type I/O cable should be specified the length in cm in『Length』column.


                                  Page 10 of 27                   Report No.: PTS1503058014F

2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS

Radiation Test equipment
            Kind of                                                      Last        Calibrated
 Item                    Manufacturer       Type No.    Serial No.
          Equipment                                                   calibration      until
           EMI Test
   1                        R&S              ESU8        100316      2014/10/25     2015/10/24
           Receiver
        Double Ridged
   2     Horn Antenna       R&S              HF907       100276       2014/11/01    2015/10/31
       (0.8GHz-18GHz)
         Log-periodic
            Dipole
   3                        R&S              HL223       100435       2014/11/01 2015/10/31
           Antenna
        (30MHz-1GHz)
             Trilog                          VULB
   4      Broadband      Schwarzbeck         9163       9163-462     2014/04/12      2015/04/11
           Antenna
            Signal
   5     Conditioning       R&S             SCU-08     10008         2014/10/25     2015/10/24
              Unit
   6       Pre-amplifer     R&S             SCU-01        10049      2014/10/25     2015/10/24
            Active loop
   7         antenna          Schwarzbeck FMZB1519      1519-038      2014/11/01    2015/10/31
           (9K-30MHz)
           Spectrum
   8                           Agilent      E4407B     MY45109572 2014/11/01        2015/10/31
            Analyzer
   9       RF cables            R&S           L03        RS710        2014/11/01    2015/10/31
  10       RF cables            R&S           L04        RS719        2014/11/01    2015/10/31


Conduction Test equipment
             Kind of      Manufactur                                    Last        Calibrated
  Item                                     Type No.     Serial No.
           Equipment         er                                      calibration       until
       1    Test Receiver        R&S         ESU8        100316      2014/10/25     2015/10/24

            Current Probe        R&S        EZ-17        100532      2014/10/25     2015/10/24
              Two Line                     ENV216        101109      2014/10/25     2015/10/24
       3                         R&S
             V-Network
           Passive Voltage                 ESH2-Z3       100169      2014/10/25     2015/10/24
       4                         R&S
                Probe
       5                                   ESH3-Z6       100694      2014/10/25     2015/10/24
             V-Network           R&S
       6     V-Network           R&S       ESH3-Z6       100690      2014/10/25     2015/10/24

       7   Artificial mains      R&S       ESH2-Z5       100309      2014/10/25     2015/10/24

       8    Pulse Limiter        R&S       ESH3-Z2       101242      2014/10/25     2015/10/24

       9      RF cables           R&S         L05        RS782       2014/11/01     2015/10/31


                                Page 11 of 27                     Report No.: PTS1503058014F


3. TEST RESULT

3.1 ANTENNA REQUIREMENT

  3.1.1 STANDARD REQUIREMENT

   15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall
    be designed to ensure that no antenna other than that furnished by the responsible party
   shall be used with the device.

  3.1.2 EUT ANTENNA

The EUT antenna is Wire Antenna. It’s permanent attached antenna. It comply with the standard
requirement.


                                  Page 12 of 27                  Report No.: PTS1503058014F


3.2 CONDUCTED EMISSION MEASUREMENT

3.2.1 POWER LINE CONDUCTED EMISSION Limits               (Frequency Range 150KHz-30MHz)

                                   Class A (dBuV)            Class B (dBuV)
   FREQUENCY (MHz)                                                                   Standard
                              Quasi-peak       Average   Quasi-peak      Average
         0.15 -0.5                                        66 - 56 *      56 - 46 *   CISPR
         0.50 -5.0                                         56.00          46.00      CISPR
         5.0 -30.0                                         60.00          50.00      CISPR


         0.15 -0.5                                        66 - 56 *      56 - 46 *   LP002.
         0.50 -5.0                                         56.00          46.00      LP002.
        5.0 -30.0                                         60.00      50.00       LP002.
       Note:
         (1) The tighter limit applies at the band edges.
         (2) The limit of " * " marked band means the limitation decreases linearly with the
             logarithm of the frequency in the range.


The following table is the setting of the receiver
             Receiver Parameters                                       Setting
                   Attenuation                                          10 dB
                 Start Frequency                                      0.15 MHz
                 Stop Frequency                                        30 MHz
                  IF Bandwidth                                          9 kHz


                                Page 13 of 27                     Report No.: PTS1503058014F



3.2.2 TEST PROCEDURE
 a. The EUT was placed 0.4 meters from the horizontal ground plane with EUT being connected
    to the power mains through a line impedance stabilization network (LISN). All other support
    equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
    impedance for the measuring instrument.
 b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
    and forth in the center forming a bundle 30 to 40 cm long.
 c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
    cable may be terminated, if required, using the correct terminating impedance. The overall
    length shall not exceed 1 m.
 d. LISN at least 80 cm from nearest part of EUT chassis.
 e. For the actual test configuration, please refer to the related Item –EUT Test Photos.
3.2.3 DEVIATION FROM TEST STANDARD
No deviation


3.2.4 TEST SETUP
                      Vertical Reference
                      Ground Plane                                            Test Receiver


                      EUT
       40cm




                                                80cm
       LISN




                                                              Horizontal Reference
                                                              Ground Plane

         Note: 1.Support units were connected to second LISN.
                 2.Both of LISNs (AMN) are 80 cm from EUT and at least 80
                   from other units and other metal planes


                                 Page 14 of 27                  Report No.: PTS1503058014F


3.2.5 TEST RESULT

EUT:              Smart Switch                     Model Name. :      ZW30
Temperature:      26 ℃                             Relative Humidity: 54%
Pressure:         1010hPa                          Phase :            L
Test Voltage :    AC 120V/60Hz                     Test Mode:         Mode 1

   Frequency     Meter Reading    Factor    Emission Level   Limits     Margin
                                                                                 Detector Type
     (MHz)          (dBμV)         (dB)          (dBμV)      (dBμV)      (dB)
     0.1700          42.82         10.12         52.94       64.96      -12.02        QP
     0.1700          25.03         10.12         35.15       54.96      -19.81       AVG
     0.3180          40.32         10.11         50.43       59.76       -9.33        QP
     0.3180          23.72         10.11         33.83       49.76      -15.93       AVG
     0.6700          40.35         10.07         50.42       56.00       -5.58        QP
     0.6700          22.68         10.07         32.75       46.00      -13.25       AVG
     1.2460          39.61         10.09         49.40       56.00       -6.60        QP
     1.2460          22.92         10.09         33.01       46.00      -12.99       AVG
     1.5500          33.54         10.09         43.63       56.00      -12.37        QP
     1.5500          19.80         10.09         29.89       46.00      -16.11       AVG
     2.2659          31.80         10.10         41.90       56.00      -14.10        QP
     2.2659          16.96         10.10         27.06       46.00      -18.94       AVG
 Remark:
 1. All readings are Quasi-Peak and Average values.
 2. Factor = Insertion Loss + Cable Loss.


                                 Page 15 of 27                      Report No.: PTS1503058014F


EUT:              Smart Switch                      Model Name. :      ZW30
Temperature:      26 ℃                              Relative Humidity: 54%
Pressure:         1010hPa                           Phase :            N
Test Voltage :    AC 120V/60Hz                      Test Mode:         Mode 1

   Frequency     Meter Reading    Factor   Emission Level     Limits       Margin
                                                                                    Detector Type
    (MHz)           (dBμV)         (dB)          (dBμV)      (dBμV)         (dB)
    0.1820           42.35        10.12          52.47        64.39        -11.92       QP
    0.1820           22.62        10.12          32.74        54.39        -21.65       AVG
    0.5420           40.47        10.08          50.55         56          -5.45        QP
    0.5420           22.23        10.08          32.31         46          -13.69       AVG
    1.1340           39.06        10.08          49.14         56          -6.86        QP
    1.1340           21.47        10.08          31.55         46          -14.45       AVG
    1.4340           36.40        10.09          46.49         56          -9.51        QP
    1.4340           22.03        10.09          32.12         46          -13.88       AVG
    1.9740           30.77        10.09          40.86         56          -15.14       QP
    1.9740           15.77        10.09          25.86         46          -20.14       AVG
    2.7500           29.34        10.10          39.44         56          -16.56       QP
    2.7500           12.25        10.10          22.35         46          -23.65       AVG
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.


                               Page 16 of 27                      Report No.: PTS1503058014F


3.3 RADIATED EMISSION MEASUREMENT

3.3.1 Radiated Emission Limits     ( FCC 15.209 )
      Frequencies              Field Strength                     Measurement Distance
          (MHz)              (micorvolts/meter)                        (meters)

      0.009~0.490                     2400/F(KHz)                         300
      0.490~1.705                    24000/F(KHz)                          30
       1.705~30.0                           30                             30
          30~88                            100                             3
         88~216                            150                             3
        216~960                            200                             3
       Above 960                           500                             3
      Note:
         (1) The tighter limit applies at the band edges.
         (2) Emission level (dBuV/m)=20log Emission level (uV/m).


     LIMITS OF RADIATED EMISSION MEASUREMENT ( FCC 15.249)
                                           Field Strength of              Field Strength of
      Frequency of Emission
                                               fundamental                  Harmonics
                (MHz)
                                           ((millivolts /meter)          (microvolts/meter)
           902-928 MHz                              50                          500
     Notes:
        (1) Emissions radiated outside of the specified frequency bands, except for harmonics,
            shall be attenuated by at least 50 dB below the level of the fundamental or to the
            general radiated emission limits in Section 15.209, whichever is the lesser
            attenuation.




 Spectrum Parameter                       Setting
 Attenuation                              Auto
 Start Frequency                          1000 MHz
 Stop Frequency                           10th carrier harmonic
 RB / VB (emission in restricted band)    1MHz / 1MHz for Peak

 Receiver Parameter                       Setting
 Attenuation                              Auto
 Start ~ Stop Frequency                   9kHz~150kHz / RB 200Hz for QP
 Start ~ Stop Frequency                   150kHz~30MHz / RB 9kHz for QP
 Start ~ Stop Frequency                   30MHz~1000MHz / RB 120kHz for QP


                                Page 17 of 27                      Report No.: PTS1503058014F


3.3.2 TEST PROCEDURE
 a. The measuring distance of at 3 m shall be used for measurements at frequency up to 1GHz.
     For frequencies above 1GHz, any suitable measuring distance may be used.
 b. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3m meter
     open area test site. The table was rotated 360 degrees to determine the position of the highest
     radiation.
 c. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the test
     antenna shall vary between 1 m to 4 m.
 d. The initial step in collecting conducted emission data is a spectrum analyzer peak detector
     mode pre-scanning the measurement frequency range. Significant peaks are then marked and
     then Quasi Peak detector mode re-measured.
 e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the
     EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement
     performed.
  f. For the actual test configuration, please refer to the related Item –EUT Test Photos.
     Note:
     Both horizontal and vertical antenna polarities were tested
     and performed pretest to three orthogonal axis. The worst case emissions were reported
3.3.3 DEVIATION FROM TEST STANDARD
No deviation


                          Page 18 of 27              Report No.: PTS1503058014F



3.3.4 TEST SETUP

(A)Radiated Emission Test-Up Frequency Below 30MHz




(B)Radiated Emission Test-Up Frequency 30MHz~1GHz


                          Page 19 of 27             Report No.: PTS1503058014F

(C)Radiated Emission Test-Up Frequency Above 1GHz


                                  Page 20 of 27                          Report No.: PTS1503058014F


3.3.5 TEST RESULTS (BLOW 30MHz)



 EUT:              Smart Switch                         Model Name. :             ZW30
 Temperature:      20 ℃                                 Relative Humidtity:       48%
 Pressure:         1010 hPa                             Test Voltage :            AC 120V
 Test Mode :       TX                                   Polarization :            --


         Freq.           Reading                  Limit                  Margin             State
         (MHz)           (dBuV/m)            (dBuV/m)                     (dB)              P/F
           --                --                    --                      --               PASS
           --                --                    --                      --               PASS


NOTE:

The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible
value has no need to be reported.
Distance extrapolation factor =40 log (specific distance/test distance)(dB);
Limit line = specific limits(dBuv) + distance extrapolation factor.


                               Page 21 of 27                        Report No.: PTS1503058014F


3.3.6 TEST RESULTS (BETWEEN 30 – 1000 MHZ)

EUT:              Smart Switch                    Model Name :       ZW30
Temperature:      20 ℃                            Relative Humidity: 48%
Pressure:         1010 hPa                        Test Voltage :     AC 120V
Test Mode :       TX                              Polarization :     Vertical


  Frequency   Meter Reading      Factor   Emission Level    Limits         Margin
                                                                                     Detector Type
    (MHz)        (dBμV)           (dB)      (dBμV/m)       (dBμV/m)         (dB)

  171.9945        14.6           9.89          24.49         43.5          -19.01        peak

  344.3854        16.17          15.22         31.39         46            -14.61        peak

   487.315        16.08          19.01         35.09         46            -10.91        peak




Remark:
1. Factor = Antenna Factor + Cable Loss – Pre-amplifier.


                               Page 22 of 27                        Report No.: PTS1503058014F


EUT:              Smart Switch                    Model Name :       ZW30
Temperature:      20 ℃                            Relative Humidity: 48%
Pressure:         1010 hPa                        Test Voltage :     AC 120V
Test Mode :       TX                              Polarization :     Horizontal


  Frequency   Meter Reading      Factor   Emission Level    Limits         Margin
                                                                                     Detector Type
    (MHz)        (dBμV)           (dB)      (dBμV/m)       (dBμV/m)         (dB)

  114.5146        14.58          11.66         26.24         43.5          -17.26        peak

  171.9945        12.46          9.89          22.35         43.5          -21.15        peak

  229.2931        14.95          10.39         25.34         46            -20.66        peak

  601.4265        15.29          21.15         36.44         46             -9.56        peak




Remark:
1. Factor = Antenna Factor + Cable Loss – Pre-amplifier.


                     Page 23 of 27                    Report No.: PTS1503058014F




Due to the PK results are less than the QP limit already, the QP measurement is not
required


                        Page 24 of 27   Report No.: PTS1503058014F


3.3.7 TEST RESULTS (ABOVE 1000 MHZ)


                           Page 25 of 27              Report No.: PTS1503058014F


Band Edge Emission:
Due to the operating frequency of this EUT is 908.42MHz only, and its 20dB BW is
just 178.36kHz, the Band Edge is not required because the allowed frequency band is
902~928MHz.


                              Page 26 of 27                   Report No.: PTS1503058014F


4. 20DB BANDWIDTH TEST


4.1 TEST PROCEDURE

 a. The EUT was directly connected to the spectrum analyzer and antenna output port as show in
    the block diagram below,
 b. Spectrum Setting : RBW= 30KHz, VBW≧RBW, Sweep time = Auto.

4.2 DEVIATION FROM STANDARD

No deviation.

4.3 TEST SETUP


                          Page 27 of 27                 Report No.: PTS1503058014F



4.4 TEST RESULTS

EUT:           Smart Switch               Model Name :       ZW30
Temperature:   26 ℃                       Relative Humidity: 53%
Pressure:      1020 hPa                   Test Power :       AC 120V
Test Mode :    TX


                          Frequency        20 dBc Bandwidth
                            (MHz)               (KHz)
                            908.42             178.36



Document Created: 2015-04-16 14:39:23
Document Modified: 2015-04-16 14:39:23

© 2024 FCC.report