Test report

FCC ID: OWT-CEU7100BT

Test Report

Download: PDF
FCCID_2575108

                               Global United Technology Services Co., Ltd.

                                                                                       Report No.: GTSE15030026601



                                        FCC REPORT
    Applicant:                         Arts Digital Technology (HK) Limited

    Address of Applicant:              RM 1607A, 16F, Fo Tan Industrial Centre 26-28 Au Pui Wan
                                       Street, Fo Tan, Shatin, Hong Kong
    Equipment Under Test (EUT)

      Product Name:                    BLUETOOTH TOWER SPEAKER WITH USB CHARGER

      Model No.:                       TSB-80316, PSP264, SP264, CEU7100-BT
      Trade Mark:                      SYLVANIA , PROSCAN, AKAI

    FCC ID:                            OWT-CEU7100BT
    Applicable standards:              FCC CFR Title 47 Part 15 Subpart C Section 15.249:2013

    Date of sample receipt:            March 19, 2015
    Date of Test:                      March 20-23, 2015
    Date of report issued:             March 24, 2015
    Test Result :                      PASS *

*     In the configuration tested, the EUT complied with the standards specified above.




    Authorized Signature:




      Robinson Lo
Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not
relate to other samples of the same product and does not permit the use of the GTS product certification mark. The
manufacturer should ensure that all products in series production are in conformity with the product sample detailed in
this report.
This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other
than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. Any
mention of GTS or testing done by GTS in connection with, distribution or use of the product described in this report must
be approved by GTS in writing.
This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 90 days only.


                                                                                Report No.: GTSE15030026601

2     Version

           Version No.                               Date                             Description
                00                              March 24, 2015                          Original




Prepared By:                                                     Date:                March 24, 2015

                                    Project Engineer



Check By:                                                        Date:                March 24, 2015

                                        Reviewer




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                            Page 2 of 32


                                                                                                                  Report No.: GTSE15030026601

3         Contents
                                                                                                                                                           Page
1     COVER PAGE ............................................................................................................................................ 1

2      VERSION .................................................................................................................................................. 2

3      CONTENTS .............................................................................................................................................. 3

4      TEST SUMMARY ..................................................................................................................................... 4

5      GENERAL INFORMATION ...................................................................................................................... 5
    5.1        CLIENT INFORMATION ......................................................................................................................... 5
    5.2        GENERAL DESCRIPTION OF EUT ......................................................................................................... 5
    5.3        TEST MODE ........................................................................................................................................ 7
    5.4        DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 7
    5.5        TEST FACILITY.................................................................................................................................... 7
    5.6        TEST LOCATION ................................................................................................................................. 7
    5.7        OTHER INFORMATION REQUESTED BY THE CUSTOMER ......................................................................... 7
6      TEST INSTRUMENTS LIST ..................................................................................................................... 8

7      TEST RESULTS AND MEASUREMENT DATA...................................................................................... 9
    7.1     ANTENNA REQUIREMENT ..................................................................................................................... 9
    7.2     CONDUCTED EMISSIONS ................................................................................................................... 10
    7.3     RADIATED EMISSION METHOD ........................................................................................................... 13
       7.3.1 Field Strength of The Fundamental Signal ................................................................................ 15
       7.3.2 Spurious emissions .................................................................................................................... 16
       7.3.3 Bandedge emissions.................................................................................................................. 20
    7.4     20DB OCCUPY BANDWIDTH .............................................................................................................. 21
8      TEST SETUP PHOTO ............................................................................................................................ 23

9      EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 25




Global United Technology Services Co., Ltd.                                                                         Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                                                     Page 3 of 32


                                                                                Report No.: GTSE15030026601

4      Test Summary
                Test Item                            Section in CFR 47                      Result
          Antenna requirement                              15.203                            Pass
    AC Power Line Conducted Emission                       15.207                            Pass
Field strength of the fundamental signal                  15.249 (a)                         Pass
           Spurious emissions                       15.249 (a) (d)/15.209                    Pass
               Band edge                              15.249 (d)/15.205                      Pass
        20dB Occupied Bandwidth                           15.215 (c)                         Pass
Pass: The EUT complies with the essential requirements in the standard.




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                            Page 4 of 32


                                                                                Report No.: GTSE15030026601

5     General Information
5.1 Client Information
      Applicant:                       Arts Digital Technology (HK) Limited
      Address of Applicant:            RM 1607A, 16F, Fo Tan Industrial Centre 26-28 Au Pui Wan Street, Fo
                                       Tan, Shatin, Hong Kong
      Manufacturer/Factory:            Shenzhen Junlan Electronic Ltd
      Address of Manufacturer/         No.277 PingKui Road, Shijing Community, Pingshan Street, Pingshan
      Factory:                         New District, Shenzhen, China.
5.2 General Description of EUT
      Product Name:                    BLUETOOTH TOWER SPEAKER WITH USB CHARGER
      Model No.:                       TSB-80316, PSP264, SP264, CEU7100-BT
      Operation Frequency:             2402MHz~2480MHz
      Channel numbers:                 79
      Channel separation:              1MHz
      Modulation type:                 GFSK, Pi/4 QPSK
      Antenna Type:                    PCB Antenna
      Antenna gain:                    2dBi
      Power supply:                    SWITCHING POWER SUPPLY
                                       Model No.: GKYPS0120120US1
                                       Input: AC 100-240V, 50/60Hz, 0.5A
                                       Output: DC 12V, 1200mA




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                            Page 5 of 32


                                                                                       Report No.: GTSE15030026601


Operation Frequency each of channel
 Channel       Frequency       Channel       Frequency      Channel      Frequency            Channel        Frequency

     1          2402MHz           21         2422MHz           41         2442MHz                61          2462MHz
     2          2403MHz           22         2423MHz           42         2443MHz                62          2463MHz
    ..….




                     ..….




                                 ..….




                                                ..….




                                                              ..….




                                                                                ..….




                                                                                                ..….




                                                                                                               ..….
    19          2420MHz           39         2440MHz           59         2460MHz                79          2480MHz
    20          2421MHz           40         2441MHz           60         2461MHz
Note:
In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the
middle frequency, and the highest frequency of channel were selected to perform the test, and the selected
channel see below:

           Channel                      Frequency

   The lowest channel                   2402MHz

  The middle channel                    2441MHz
  The Highest channel                   2480MHz




Global United Technology Services Co., Ltd.                                            Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                   Page 6 of 32


                                                                                Report No.: GTSE15030026601


5.3 Test mode
      Transmitting mode                   Keep the EUT in continuously transmitting mode
Remark: During the test, the test voltage was tuned from 85% to 115% of the nominal rated supply voltage,
and found that the worst case was under the nominal rated supply condition. So the report just shows that
condition’s data.


Per-test mode.
We have verified the construction and function in typical operation, The EUT was placed on three different
polar directions; i.e. X axis, Y axis, Z axis. which was shown in this test report and defined as follows:
             Axis                         X                            Y                           Z
  Field Strength(dBuV/m)                91.87                        94.98                     93.05
Final Test Mode:
The EUT was tested in GFSK, Pi/4DQPSK, modulation, and found the GFSK modulation is the worst case.
According to ANSI C63.4 standards, the test results are both the “worst case” and “worst setup”:
Y axis (see the test setup photo)
5.4 Description of Support Units
      None
5.5 Test Facility
      The test facility is recognized, certified, or accredited by the following organizations:
      ● CNAS —Registration No.: CNAS L5775
      CNAS has accredited Global United Technology Services Co., Ltd. To ISO/IEC 17025 General
      Requirements for the competence of testing and calibration laboratories (CNAS-CL01 Accreditation
      Criteria for the Competence of Testing and Calibration Laboratories) for the competence in the field of
      testing.
      ● FCC —Registration No.: 600491
      Global United Technology Services Co., Ltd., Shenzhen EMC Laboratory has been registered and fuly
      described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
      from the FCC is maintained in files. Registration 600491, June 28, 2013.
      ● Industry Canada (IC) —Registration No.: 9079A-2
      The 3m Semi-anechoic chamber of Global United Technology Services Co., Ltd. has been registered by
      Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration
      No.: 9079A-2, June 26, 2013.
5.6 Test Location
      All tests were performed at:
      Global United Technology Services Co., Ltd.
      Address: Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building, No. 300 Laodong
      Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
      Tel: 0755-27798480
      Fax: 0755-27798960
5.7 Other Information Requested by the Customer
      None.




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                            Page 7 of 32


                                                                                  Report No.: GTSE15030026601

6       Test Instruments list
Radiated Emission:
                                                                           Inventory        Cal.Date      Cal.Due date
Item      Test Equipment         Manufacturer           Model No.
                                                                              No.          (mm-dd-yy)     (mm-dd-yy)
        3m Semi- Anechoic
 1                             ZhongYu Electron    9.2(L)*6.2(W)* 6.4(H)   GTS250        Mar. 29 2014     Mar. 28 2015
            Chamber
 2        Control Room         ZhongYu Electron    6.2(L)*2.5(W)* 2.4(H)   GTS251             N/A               N/A
 3       Spectrum Analyzer          Agilent              E4440A            GTS533         Jul. 01 2014    Jun 30 2015

 4       EMI Test Receiver     Rohde & Schwarz           ESU26             GTS203         Jul. 01 2014    Jun 30 2015
                               SCHWARZBECK
 5       BiConiLog Antenna                              VULB9163           GTS214         Jul. 01 2014    Jun 30 2015
                              MESS-ELEKTRONIK
          Double -ridged       SCHWARZBECK
 6                                                      9120D-829          GTS208        June 27 2014     June 26 2015
          waveguide horn      MESS-ELEKTRONIK
7          Horn Antenna        ETS-LINDGREN               3160             GTS217        Mar. 28 2014     Mar. 27 2015
8        EMI Test Software         AUDIX                   E3               N/A               N/A              N/A
9          Coaxial Cable            GTS                   N/A              GTS213        Mar. 29 2014     Mar. 28 2015
10         Coaxial Cable            GTS                   N/A              GTS211        Mar. 29 2014     Mar. 28 2015
11          Coaxial cable           GTS                   N/A              GTS210        Mar. 29 2014     Mar. 28 2015
12         Coaxial Cable            GTS                   N/A              GTS212        Mar. 29 2014     Mar. 28 2015
13     Amplifier(100kHz-3GHz)        HP                  8347A             GTS204        Jul. 01 2014     Jun. 30, 2015
14     Amplifier(2GHz-20GHz)         HP                  8349B             GTS206        Jul. 01 2014     Jun. 30, 2015
15                                                    AFS33-18002
        Amplifier (18-26GHz)   Rohde & Schwarz                             GTS218        June 27 2014     June 26 2015
                                                      650-30-8P-44
16           Band filter           Amindeon               82346            GTS219        Mar. 29 2014     Mar. 28 2015



Conducted Emission:

                                                                           Inventory         Cal.Date        Cal.Due date
Item      Test Equipment          Manufacturer           Model No.
                                                                                No.         (mm-dd-yy)       (mm-dd-yy)

 1        Shielding Room        ZhongYu Electron   7.0(L)x3.0(W)x3.0(H)     GTS264         July 01 2014   June 30 2015

 2       EMI Test Receiver      Rohde & Schwarz           ESCS30            GTS223         July 01 2014   June 30 2015

 3       10dB Pulse Limita      Rohde & Schwarz             N/A             GTS224         July 01 2014   June 30 2015

 4         Coaxial Switch       ANRITSU CORP              MP59B             GTS225         July 01 2014   June 30 2015

                                SCHWARZBECK
 5              LISN                                    NSLK 8127           GTS226         July 01 2014   June 30 2015
                               MESS-ELEKTRONIK

 6         Coaxial Cable             GTS                    N/A             GTS227         July 01 2014   June 30 2015

 7       EMI Test Software          AUDIX                   E3                  N/A            N/A              N/A




Global United Technology Services Co., Ltd.                                           Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                   Page 8 of 32


                                                                                    Report No.: GTSE15030026601

7      Test results and Measurement Data
7.1 Antenna requirement
      Standard requirement:            FCC Part15 C Section 15.203
      15.203 requirement:
       An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible
       party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a
       unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be
       replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited.
      E.U.T Antenna:

        The antenna is PCB Antenna, the best case gain of the antenna is 2dBi




Global United Technology Services Co., Ltd.                                           Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                    Page 9 of 32


                                                                                Report No.: GTSE15030026601


7.2 Conducted Emissions
      Test Requirement:              FCC Part15 C Section 15.207
      Test Method:                   ANSI C63.4:2009
      Test Frequency Range:          150KHz to 30MHz
      Class / Severity:              Class B
      Receiver setup:                RBW=9KHz, VBW=30KHz, Sweep time=auto
      Limit:                                                                       Limit (dBuV)
                                        Frequency range (MHz)
                                                                        Quasi-peak              Average
                                               0.15-0.5                   66 to 56*             56 to 46*
                                                0.5-5                         56                   46
                                                 5-30                         60                   50
                                     * Decreases with the logarithm of the frequency.
      Test setup:




      Test procedure:                1. The E.U.T and simulators are connected to the main power through a
                                        line impedance stabilization network (L.I.S.N.). This provides a
                                        50ohm/50uH coupling impedance for the measuring equipment.
                                     2. The peripheral devices are also connected to the main power through a
                                        LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                        termination. (Please refer to the block diagram of the test setup and
                                        photographs).
                                     3. Both sides of A.C. line are checked for maximum conducted
                                        interference. In order to find the maximum emission, the relative
                                        positions of equipment and all of the interface cables must be changed
                                        according to ANSI
                                                      ANSI C63.4:
                                                            C63.4: 2009
                                                                     2003 on conducted measurement.
      Test Instruments:              Refer to section 6.0 for details
      Test mode:                     Refer to section 5.3 for details
      Test results:                  Pass


Measurement data:




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 10 of 32


                                                                                Report No.: GTSE15030026601
Line:




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 11 of 32


                                                                                Report No.: GTSE15030026601


Neutral:




Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss
4. If the average limit is met when using a quasi-peak detector receiver, the EUT shall be deemed to meet
   both limits and measurement with the average detector receiver is unnecessary.




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 12 of 32


                                                                                Report No.: GTSE15030026601


7.3 Radiated Emission Method
      Test Requirement:              FCC Part15 C Section 15.209
      Test Method:                   ANSI C63.4:2009
      Test Frequency Range:          30MHz to 25GHz
      Test site:                     Measurement Distance: 3m
      Receiver setup:                   Frequency        Detector        RBW        VBW           Remark
                                         30MHz-         Quasi-peak      120KHz     300KHz    Quasi-peak Value
                                          1GHz
                                                           Peak          1MHz       3MHz        Peak Value
                                      Above 1GHz
                                                           Peak          1MHz       10Hz       Average Value
      Limit:                                  Frequency              Limit (dBuV/m @3m)           Remark
      (Field strength of the                                                  94.00            Average Value
                                        2400MHz-2483.5MHz
      fundamental signal)                                                    114.00             Peak Value
      Limit:                                   Frequency            Limit (dBuV/m @3m)            Remark
      (Spurious Emissions)                  30MHz-88MHz                     40.00            Quasi-peak Value
                                            88MHz-216MHz                    43.50            Quasi-peak Value
                                           216MHz-960MHz                    46.00            Quasi-peak Value
                                             960MHz-1GHz                    54.00            Quasi-peak Value
                                                                            54.00              Average Value
                                            Above 1GHz
                                                                            74.00               Peak Value
      Limit:                         Emissions radiated outside of the specified frequency bands, except for
      (band edge)                    harmonics, shall be attenuated by at least 50 dB below the level of the
                                     fundamental or to the general radiated emission limits in Section 15.209,
                                     whichever is the lesser attenuation.
      Test setup:                    Below 1GHz




                                     Above 1GHz




Global United Technology Services Co., Ltd.                                      Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                            Page 13 of 32


                                                                                Report No.: GTSE15030026601




      Test Procedure:                1. The EUT was placed on the top of a rotating table 0.8 meters above the
                                        ground at a 3 meter camber. The table was rotated 360 degrees to
                                        determine the position of the highest radiation.
                                     2. The EUT was set 3 meters away from the interference-receiving
                                        antenna, which was mounted on the top of a variable-height antenna
                                        tower.
                                     3. The antenna height is varied from one meter to four meters above the
                                        ground to determine the maximum value of the field strength. Both
                                        horizontal and vertical polarizations of the antenna are set to make the
                                        measurement.
                                     4. For each suspected emission, the EUT was arranged to its worst case
                                        and then the antenna was tuned to heights from 1 meter to 4 meters
                                        and the rota table was turned from 0 degrees to 360 degrees to find the
                                        maximum reading.
                                     5. The test-receiver system was set to Peak Detect Function and
                                        Specified Bandwidth with Maximum Hold Mode.
                                     6. If the emission level of the EUT in peak mode was 10dB lower than the
                                        limit specified, then testing could be stopped and the peak values of the
                                        EUT would be reported. Otherwise the emissions that did not have
                                        10dB margin would be re-tested one by one using peak, quasi-peak or
                                        average method as specified and then reported in a data sheet.
      Test Instruments:              Refer to section 6.0 for details
      Test mode:                     Refer to section 5.3 for details
      Test results:                  Pass


Measurement data:




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                            Page 14 of 32


                                                                                Report No.: GTSE15030026601

7.3.1   Field Strength of The Fundamental Signal
Peak value:
                 Read       Antenna       Cable      Preamp                                    Over
Frequency                                                           Level       Limit Line
                 Level       Factor       Loss        Factor                                   Limit      polarization
  (MHz)                                                           (dBuV/m)      (dBuV/m)
                (dBuV)       (dB/m)        (dB)        (dB)                                    (dB)
  2402.00        91.45        27.58        5.39        30.18        94.24        114.00       -19.76        Vertical
  2402.00        88.60        27.58        5.39        30.18        91.39        114.00       -22.61      Horizontal
  2441.00        91.77        27.55        5.43        30.06        94.69        114.00       -19.31        Vertical
  2441.00        89.46        27.55        5.43        30.06        92.38        114.00       -21.62      Horizontal
  2480.00        91.92        27.52        5.47        29.93        94.98        114.00       -19.02        Vertical
  2480.00        88.78        27.52        5.47        29.93        91.84        114.00       -22.16      Horizontal
Average value:
                 Read       Antenna       Cable      Preamp                                    Over
Frequency                                                           Level       Limit Line
                 Level       Factor       Loss        Factor                                   Limit      polarization
  (MHz)                                                           (dBuV/m)      (dBuV/m)
                (dBuV)       (dB/m)        (dB)        (dB)                                    (dB)
  2402.00        81.40        27.58        5.39        30.18        84.19         94.00        -9.81        Vertical
  2402.00        78.66        27.58        5.39        30.18        81.45         94.00       -12.55      Horizontal
  2441.00        80.42        27.55        5.43        30.06        83.34         94.00       -10.66        Vertical
  2441.00        78.44        27.55        5.43        30.06        81.36         94.00       -12.64      Horizontal
  2480.00        81.54        27.52        5.47        29.93        84.60         94.00        -9.40        Vertical
  2480.00        78.33        27.52        5.47        29.93        81.39         94.00       -12.61      Horizontal


Remark: RBW 3MHz, VBW 10MHz , peak detector for PK value, RBW 3MHz, VBW 10MHz AV detector for AV value




Global United Technology Services Co., Ltd.                                      Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 15 of 32


                                                                                Report No.: GTSE15030026601

7.3.2   Spurious emissions
    Below 1GHz
                 Read       Antenna       Cable      Preamp                                    Over
Frequency                                                           Level       Limit Line
                 Level       Factor       Loss        Factor                                   Limit      polarization
  (MHz)                                                           (dBuV/m)      (dBuV/m)
                (dBuV)       (dB/m)        (dB)        (dB)                                    (dB)
    53.88       51.81         15.07        0.81        31.95        35.74         40.00        -4.26        Vertical
    103.81      50.65         14.78        1.22        31.78        34.87         43.50        -8.63        Vertical
    126.33      50.87         11.51        1.41        31.89        31.90         43.50       -11.60        Vertical
    312.18      40.69         15.22        2.42        32.14        26.19         46.00       -19.81        Vertical
    554.83      36.43         19.67        3.54        31.27        28.37         46.00       -17.63        Vertical
    706.70      38.24         20.86        4.12        31.20        32.02         46.00       -13.98        Vertical
    56.99       44.93         14.89        0.84        31.95        28.71         40.00       -11.29      Horizontal
    96.44       43.31         14.94        1.16        31.75        27.66         43.50       -15.84      Horizontal
    194.45      38.31         12.56        1.81        32.12        20.56         43.50       -22.94      Horizontal
    332.52      38.73         15.86        2.53        32.08        25.04         46.00       -20.96      Horizontal
    750.11      37.95         21.43        4.28        31.26        32.40         46.00       -13.60      Horizontal
    564.64      36.20         19.83        3.58        31.22        28.39         46.00       -17.61      Horizontal




Global United Technology Services Co., Ltd.                                      Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 16 of 32


                                                                                Report No.: GTSE15030026601

     Above 1GHz
Test channel:                                             Lowest channel
Peak value:
                 Read        Antenna       Cable      Preamp                                   Over
Frequency                                                           Level       Limit Line
                 Level        Factor       Loss        Factor                                  Limit      polarization
  (MHz)                                                           (dBuV/m)      (dBuV/m)
                (dBuV)        (dB/m)        (dB)        (dB)                                   (dB)
    4804.00      35.45        31.78        8.60        32.09        43.74         74.00       -30.26        Vertical
    7206.00      30.60        36.15        11.65       32.00        46.40         74.00       -27.60        Vertical
    9608.00      30.37        37.95        14.14       31.62        50.84         74.00       -23.16        Vertical
 12010.00          *                                                              74.00                     Vertical
 14412.00          *                                                              74.00                     Vertical
    4804.00      39.35        31.78        8.60        32.09        47.64         74.00       -26.36      Horizontal
    7206.00      32.19        36.15        11.65       32.00        47.99         74.00       -26.01      Horizontal
    9608.00      29.62        37.95        14.14       31.62        50.09         74.00       -23.91      Horizontal
 12010.00          *                                                              74.00                   Horizontal
 14412.00          *                                                              74.00                   Horizontal
Average value:
                 Read       Antenna       Cable      Preamp                                    Over
Frequency                                                           Level       Limit Line
                 Level       Factor       Loss       Factor                                    Limit      polarization
  (MHz)                                                           (dBuV/m)      (dBuV/m)
                (dBuV)       (dB/m)        (dB)       (dB)                                     (dB)
    4804.00      24.61        31.78        8.60       32.09         32.90         54.00       -21.10        Vertical
    7206.00      19.49        36.15       11.65       32.00         35.29         54.00       -18.71        Vertical
    9608.00      18.69        37.95       14.14       31.62         39.16         54.00       -14.84        Vertical
 12010.00          *                                                              54.00                     Vertical
 14412.00          *                                                              54.00                     Vertical
    4804.00      28.64        31.78        8.60       32.09         36.93         54.00       -17.07      Horizontal
    7206.00      21.55        36.15       11.65       32.00         37.35         54.00       -16.65      Horizontal
    9608.00      18.26        37.95       14.14       31.62         38.73         54.00       -15.27      Horizontal
 12010.00          *                                                              54.00                   Horizontal
 14412.00         *                                                             54.00                Horizontal
Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. The emission levels of other frequencies are very lower than the limit and not show in test report.
3. “*”, means this data is the too weak instrument of signal is unable to test.




Global United Technology Services Co., Ltd.                                      Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 17 of 32


                                                                                Report No.: GTSE15030026601

Test channel:                                             Middle channel
Peak value:
                 Read       Antenna       Cable      Preamp                                    Over
Frequency                                                           Level       Limit Line
                 Level       Factor       Loss       Factor                                    Limit      polarization
  (MHz)                                                           (dBuV/m)      (dBuV/m)
                (dBuV)       (dB/m)        (dB)       (dB)                                     (dB)
  4882.00        34.95        31.85        8.67       32.12         43.35         74.00       -30.65        Vertical
  7323.00        30.27        36.37       11.72       31.89         46.47         74.00       -27.53        Vertical
  9764.00        30.08        38.35       14.25       31.62         51.06         74.00       -22.94        Vertical
 12205.00          *                                                              74.00                     Vertical
 14646.00          *                                                              74.00                     Vertical
  4882.00        38.75        31.85        8.67       32.12         47.15         74.00       -26.85      Horizontal
  7323.00        31.81        36.37       11.72       31.89         48.01         74.00       -25.99      Horizontal
  9764.00        29.28        38.35       14.25       31.62         50.26         74.00       -23.74      Horizontal
 12205.00          *                                                              74.00                   Horizontal
 14646.00          *                                                              74.00                   Horizontal
Average value:
                 Read       Antenna       Cable      Preamp                                    Over
Frequency                                                           Level       Limit Line
                 Level       Factor       Loss       Factor                                    Limit      polarization
  (MHz)                                                           (dBuV/m)      (dBuV/m)
                (dBuV)       (dB/m)        (dB)       (dB)                                     (dB)
  4882.00        24.21        31.85        8.67       32.12         32.61         54.00       -21.39        Vertical
  7323.00        19.22        36.37       11.72       31.89         35.42         54.00       -18.58        Vertical
  9764.00        18.45        38.35       14.25       31.62         39.43         54.00       -14.57        Vertical
 12205.00          *                                                              54.00                     Vertical
 14646.00          *                                                              54.00                     Vertical
  4882.00        28.18        31.85        8.67       32.12         36.58         54.00       -17.42      Horizontal
  7323.00        21.24        36.37       11.72       31.89         37.44         54.00       -16.56      Horizontal
  9764.00        17.98        38.35       14.25       31.62         38.96         54.00       -15.04      Horizontal
 12205.00          *                                                              54.00                   Horizontal
 14646.00         *                                                             54.00                Horizontal
Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. The emission levels of other frequencies are very lower than the limit and not show in test report.
3. “*”, means this data is the too weak instrument of signal is unable to test.




Global United Technology Services Co., Ltd.                                      Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 18 of 32


                                                                                Report No.: GTSE15030026601

Test channel:                                             Highest channel
Peak value:
                 Read       Antenna       Cable      Preamp                                    Over
Frequency                                                           Level       Limit Line
                 Level       Factor       Loss       Factor                                    Limit      polarization
  (MHz)                                                           (dBuV/m)      (dBuV/m)
                (dBuV)       (dB/m)        (dB)       (dB)                                     (dB)
  4960.00        35.94        31.93        8.73       32.16         44.44         74.00       -29.56        Vertical
  7440.00        30.93        36.59       11.79       31.78         47.53         74.00       -26.47        Vertical
  9920.00        30.66        38.81       14.38       31.88         51.97         74.00       -22.03        Vertical
 12400.00          *                                                              74.00                     Vertical
 14880.00          *                                                              74.00                     Vertical
  4960.00        39.95        31.93        8.73       32.16         48.45         74.00       -25.55      Horizontal
  7440.00        32.56        36.59       11.79       31.78         49.16         74.00       -24.84      Horizontal
  9920.00        29.96        38.81       14.38       31.88         51.27         74.00       -22.73      Horizontal
 12400.00          *                                                              74.00                   Horizontal
 14880.00          *                                                              74.00                   Horizontal
Average value:
                 Read       Antenna       Cable      Preamp                                    Over
Frequency                                                           Level       Limit Line
                 Level       Factor       Loss       Factor                                    Limit      polarization
  (MHz)                                                           (dBuV/m)      (dBuV/m)
                (dBuV)       (dB/m)        (dB)       (dB)                                     (dB)
  4960.00        25.06        31.93        8.73       32.16         33.56         54.00       -20.44        Vertical
  7440.00        19.80        36.59       11.79       31.78         36.40         54.00       -17.60        Vertical
  9920.00        18.95        38.81       14.38       31.88         40.26         54.00       -13.74        Vertical
 12400.00          *                                                              54.00                     Vertical
 14880.00          *                                                              54.00                     Vertical
  4960.00        29.14        31.93        8.73       32.16         37.64         54.00       -16.36      Horizontal
  7440.00        21.88        36.59       11.79       31.78         38.48         54.00       -15.52      Horizontal
  9920.00        18.58        38.81       14.38       31.88         39.89         54.00       -14.11      Horizontal
 12400.00          *                                                              54.00                   Horizontal
 14880.00         *                                                             54.00                Horizontal
Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. The emission levels of other frequencies are very lower than the limit and not show in test report.
3. “*”, means this data is the too weak instrument of signal is unable to test.




Global United Technology Services Co., Ltd.                                      Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 19 of 32


                                                                                  Report No.: GTSE15030026601

7.3.3   Bandedge emissions
        All of the restriction bands were tested, and only the data of worst case was exhibited.
Test channel:                                                 Lowest channel
Peak value:
                 Read       Antenna       Cable      Preamp                                      Over
Frequency                                                           Level       Limit Line
                 Level       Factor       Loss        Factor                                     Limit       Polarization
  (MHz)                                                           (dBuV/m)      (dBuV/m)
                (dBuV)       (dB/m)        (dB)        (dB)                                      (dB)
 2390.00        44.83        27.59        5.38        30.18         47.62         74.00         -26.38       Horizontal
 2400.00        61.90        27.58        5.39        30.18         64.69         74.00          -9.31       Horizontal
 2390.00      45.57          27.59        5.38        30.18         48.36         74.00         -25.64         Vertical
 2400.00      64.14          27.58        5.39        30.18         66.93         74.00          -7.07         Vertical
Average value:
              Read          Antenna      Cable       Preamp                                      Over
Frequency                                                           Level       Limit Line
              Level          Factor      Loss         Factor                                     Limit       Polarization
  (MHz)                                                           (dBuV/m)      (dBuV/m)
             (dBuV)          (dB/m)       (dB)         (dB)                                       (dB)
 2390.00      34.94           27.59      5.38         30.18         37.73         54.00         -16.27       Horizontal
 2400.00      46.29           27.58      5.39         30.18         49.08         54.00          -4.92       Horizontal
 2390.00      35.02           27.59      5.38         30.18         37.81         54.00         -16.19        Vertical
 2400.00      48.13           27.58      5.39         30.18         50.92         54.00          -3.08        Vertical

Test channel:                                                 Highest channel
Peak value:
                 Read       Antenna       Cable      Preamp                                      Over
Frequency                                                           Level       Limit Line
                 Level       Factor       Loss        Factor                                     Limit       Polarization
  (MHz)                                                           (dBuV/m)      (dBuV/m)
                (dBuV)       (dB/m)        (dB)        (dB)                                      (dB)
 2483.50        47.17        27.53        5.47        29.93         50.24         74.00         -23.76       Horizontal
 2500.00        45.97        27.55        5.49        29.93         49.08         74.00         -24.92       Horizontal
 2483.50        48.33        27.53        5.47        29.93         51.40         74.00         -22.60         Vertical
 2500.00        47.15        27.55        5.49        29.93         50.26         74.00         -23.74         Vertical
Average value:
              Read         Antenna       Cable       Preamp
Frequency                                                          Level        Limit Line      Over
              Level         Factor       Loss        Factor                                                  Polarization
  (MHz)                                                          (dBuV/m)       (dBuV/m)      Limit (dB)
             (dBuV)         (dB/m)        (dB)        (dB)
 2483.50        37.79        27.53        5.47        29.93        40.86          54.00         -13.14       Horizontal
 2500.00        35.51        27.55        5.49        29.93        38.62          54.00         -15.38       Horizontal
 2483.50        39.16        27.53        5.47        29.93        42.23          54.00         -11.77         Vertical
 2500.00     35.60       27.55       5.49      29.93       38.71       54.00       -15.29                      Vertical
Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor




Global United Technology Services Co., Ltd.                                        Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                  Page 20 of 32


                                                                                Report No.: GTSE15030026601

7.4 20dB Occupy Bandwidth
      Test Requirement:              FCC Part15 C Section 15.249/15.215
      Test Method:                   ANSI C63.4:2009
      Limit:                         Operation Frequency range 2400MHz~2483.5MHz
      Test setup:




      Test Instruments:              Refer to section 6.0 for details
      Test mode:                     Refer to section 5.3 for details
      Test results:                  Pass


Measurement Data
         Test channel                       20dB bandwidth(MHz)                           Result
               Lowest                               0.815                                  Pass
               Middle                               0.815                                  Pass
               Highest                              0.813                                  Pass


Test plot as follows:




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 21 of 32


                                                                                Report No.: GTSE15030026601




                                                Lowest channel




                                                 Middle channel




                                                Highest channel




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 22 of 32


                                                                                Report No.: GTSE15030026601

8     Test Setup Photo
       Radiated Emission




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 23 of 32


                                                                                Report No.: GTSE15030026601


       Conducted Emissions




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 24 of 32


                                                                                Report No.: GTSE15030026601


9     EUT Constructional Details




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 25 of 32


                                                                                Report No.: GTSE15030026601




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 26 of 32


                                                                                Report No.: GTSE15030026601




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 27 of 32


                                                                                Report No.: GTSE15030026601




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 28 of 32


                                                                                Report No.: GTSE15030026601




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 29 of 32


                                                                                Report No.: GTSE15030026601




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 30 of 32


                                                                                Report No.: GTSE15030026601




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 31 of 32


                                                                                Report No.: GTSE15030026601




                                                  ------End------




Global United Technology Services Co., Ltd.                                     Project No.: GTSE150300266RF
Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building,
No. 300 Laodong Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 32 of 32



Document Created: 2015-04-02 19:18:59
Document Modified: 2015-04-02 19:18:59

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC