Specification

FCC ID: OWS-925

Parts List/Tune Up Info

Download: PDF
FCCID_124347

C & I Meter Hardware Specification

            Internal Document




               Version: 1.3


             February 3, 2000


Gateway Hardware Specification                                                                                                           February 3, 2000



                                                         Table of Contents


TABLE OF CONTENTS...............................................................................................................................2

1.      INTRODUCTION ..................................................................................................................................3

2.      MODULE SPECIFICATION ...............................................................................................................4
     2.1     POWER S UPPLY .................................................................................................................................4
        2.1.1 Electrical ......................................................................................................................................4
        2.1.2 Mechanical ...................................................................................................................................4
     2.2     CONTROL MODULE ...........................................................................................................................4
        2.2.1 Electrical ......................................................................................................................................4
        2.2.2 Mechanical ...................................................................................................................................5
     2.3     NCI MODULE ....................................................................................................................................5
        2.3.1 Electrical ......................................................................................................................................5
        2.3.2 Mechanical ...................................................................................................................................5
     2.4     PAGER ...............................................................................................................................................5
        2.4.1 Electrical ......................................................................................................................................5
     2.5     POTS MODEM ..................................................................................................................................5
        2.5.1 Electrical ......................................................................................................................................5
        2.5.2 Mechanical ...................................................................................................................................5
3.      TAMPER SWITCH ...............................................................................................................................6

4.      BATTERY BACKUP.............................................................................................................................6

5.      ENCLOSURE .........................................................................................................................................6

6.      ANTENNAS ............................................................................................................................................6
     6.1        LAN ANTENNA.................................................................................................................................6
     6.2        WAN ANTENNA................................................................................................................................6
7.      HOUSING CONNECTORS..................................................................................................................7

8.      EXTERNAL CABLES (OPTIONAL)..................................................................................................7

9.      ENVIRONMENTAL..............................................................................................................................7

10.         BLOCK DIAGRAM...........................................................................................................................8

REVISION HISTORY...................................................................................................................................9




Innovatec Communications Confidential                                    Version 1.3                                                              Page 2 of 9


Gateway Hardware Specification                                                                                                   February 3, 2000



1. Introduction
The purpose of this document is to outline all the requirements necessary for the C & I Meter. The C & I
Meter will be the link between the Information Managing Units (IMU), the Commercial and Industrial
(C&I) Electric Meter and the head end system. The IMUs will reside on the water and gas meters, which
will communicate with the C & I Meter via RF. The C & I Meter may reside on a pole top. There will be
two types of C & I Meter Wide Area Network (WAN) interfaces defined within this document, however
the WAN interface is not limited to just these two. One will communicate back to the head end via a
wireless paging system and the other will communicate via Plain Old Telephone Service (POTS).

The C & I Meter will consist of a Power Supply, a Control Module, a Network Communications Interface
(NCI), a paging or POTS modem and one or two antennas depending on the type of C & I Meter required.
The specifications for these modules are listed in the following sections. Presented below are two diagrams
depicting the two types of networks that are possible, using the C & I Meter.


                                                                                                  Telephone Service
                       Pag
                             ing
                                   Sys                          IMU                                                                       IMU
                                         tem
                                                          LAN                                                                    LAN

                                               Pole Top         IMU                                                   Pole Top
                                               Gateway                                                                                    IMU
                                                                                                                      Gateway



     Head End System                                            IMU             Head End System                                           IMU




         Paging Based WAN C & I Meter                                                POTS Based WAN C & I Meter




Innovatec Communications Confidential                             Version 1.3                                                          Page 3 of 9


Gateway Hardware Specification                                                               February 3, 2000



2. Module Specification
The specifications for each of the modules described above and their enclosure are listed in this section.

2.1     Power Supply

2.1.1     Electrical

•     90 – 265 VAC input voltage range.
•     50 or 60 Hz.
•     100% operational with 100 mS of service interruption.
•     +5 VDC ± 5% @ 3.5 A output, continuous.
•     +3.6 VDC @ 300 mA output, continuous.
•     Maximum ripple of ± 100 mV.
•     Load Regulation of ± 5 %.
•     Isolation designed to applicable portions of the ANSI C-12 standard.
•     Processor controller power recycling.
•     Appropriate Electro Static Discharge (ESD) and lightning protection for the power supply.

2.1.2     Mechanical

•     1 Green “POWER” LED
•     1 Red “HEARTBEAT” LED on the Ampro parallel port.
•     1 Red “STATUS” LED on the Ampro parallel port.
•     1 Yellow “TX” and 1 Green “RX” LEDs on the Pager.
•     1 Yellow “TX” and 1 Green “RX” LEDs on the NCI.
•     1 4 pin 0.100” centers header for a manufacturer keyboard connection.
•     A TBD connector for a battery charger card.
•     An SPI UART and RS232 level shifter for interface with the NCI.
•     A manual processor reset, push button switch.
•     PC/104 power interface; 1-64 and 1-40 pin dual row 0.100” centers female sockets.
•     2-10 pin 0.100” centers dual row female sockets for the Ampro COM1 and COM2 RS232 serial ports.
•     1-10 pin 0.100” centers dual row female socket for the Ampro utility port.
•     1-26 pin 0.100” centers dual row female socket for the Ampro parallel port.
•     4 mounting holes for the PC/104 card.
•     2-22 pin 2 mm centers dual row female shrouded connector for Pager and for NCI board.
•     4 mounting holes for the Pager.
•     4 mounting holes for the NCI board.
•     A 5 pin straight, keyed Molex type 0.156” centers header, with pins 2 and 4 removed, for power
      connection.
•     A 3 pin straight, keyed Molex type 0.156” centers header, with pin 2 removed, for telco connection.
•     A 2 pin straight, keyed Molex type 0.156” centers header for the modem connection.

2.2     Control Module

2.2.1     Electrical

•     Ampro CoreModule / 3SXi.
•     +5 VDC powered through PC/104 Interface.
•     500 mA consumption.




Innovatec Communications Confidential            Version 1.3                                      Page 4 of 9


Gateway Hardware Specification                                                              February 3, 2000


2.2.2     Mechanical

•     PC/104 form factor and interface.
•     Two serial (RS232) ports with a 10 pin dual row straight 0.100” centers headers placed on the bottom
      of the board.
•     One parallel interface port with a 26 pin dual row straight 0.100” centers headers placed on the bottom
      of the board.
•     One utility port with a 10 pin dual row straight 0.100” centers headers placed on the bottom of the
      board.

2.3     NCI Module

2.3.1     Electrical

•     900 mA @ +5 VDC and 150 mA @ +3.6 VDC power supply.
•     RF Specification (Refer to NCI specification document).
•     Appropriate Electro Static Discharge (ESD) and lightning protection on the antenna connection.

2.3.2     Mechanical

•     1-22 pin 2 mm centers dual row male shrouded connector, placed on the bottom of the board for
      power, serial (RS232) and other I/O connections.
•     One right angle SMA connector for the external antenna.

2.4     Pager

2.4.1     Electrical

•     Motorola ReFlex CreateaLink 2XT transceiver.
•     2 A max at +5 VDC power consumption set at 2 W transmit power.

2.5     POTS Modem

2.5.1     Electrical

•     33.6Kbps data modem.
•     200 mA @ +5 VDC power supply.
•     Appropriate Electro Static Discharge (ESD) and lightning protection on the telephone line connection.

2.5.2     Mechanical

•     PC/104 form factor and interface.
•     Do not populate RJ11 connectors.
•     Solder to TIP and RING connections 2-22 AWG wires with a Molex type, keyed female connector on
      the other end of the cable.




Innovatec Communications Confidential            Version 1.3                                      Page 5 of 9


Gateway Hardware Specification                                                           February 3, 2000



3. Tamper Switch
A tamper switch in the form of a mechanical switch will be provided. The switch will be actuated by the
lid on the enclosure. The switch will be in the closed position for as long as the lid is closed on the
enclosure. Once the lid is opened the switch will open signaling the processor of a tamper situation.



4. Battery Backup
A battery backup is required such that if the C & I Meter detects MAINS power outage, it will signal the
head end via the WAN of the outage. The battery will hold long enough to support a connection on either
of the two currently supported WAN interfaces, telco and pager.

There will also be a charger card associated with the type of battery used.



5. Enclosure
•     NEMA 4X steel type.
•     Powder coated (white preferred for final product).
•     8"x 6"x 3.5” in dimension.
•     Dedicated grounding stud.
•     Hinged lid with a weather proof gasket.
•     4 outside connector holes; 1 for the power connector, 1 for the LAN antenna connector and 1
      for the WAN antenna connector or the telco connector.



6. Antennas
6.1     LAN Antenna

•     902 – 928 MHz.
•     6 dBi Gain.
•     N type connector.
•     50 Ohms.
•     Water resistant.

6.2     WAN Antenna

•     896 – 942 MHz.
•     6 dBi Gain.
•     N type connector.
•     50 Ohms.
•     Water resistant.




Innovatec Communications Confidential            Version 1.3                                   Page 6 of 9


Gateway Hardware Specification                                                         February 3, 2000



7. Housing Connectors
•   N type, antenna bulkhead connector with a 10 inches RG316/U cable and a right angle SMA on the
    other end of the cable.
•   4 pin Power metal type female connector with 4-18 AWG, XX inches wires, and a 5 pin keyed female
    0.156” centers connector on the other end of the cable.
•   3 pin telco metal type female connector with 3-18 AWG, XX inches wires, and a 3 pin keyed female
    0.156” centers connector on the other end of the cable.



8. External Cables (Optional)
•   4 pin Power metal type male over-molded connector with 4-18 AWG shielded and sleeved, 12 feet
    wires, and a 3 prong light pole power connector on the other end of the cable.
•   3 pin telco metal type male over-molded with 3-18 AWG shielded and sleeved, 20 feet wires, without
    any termination on the other end of the cable.



9. Environmental
•            o
    -40 - +85 C working temperature range.
•   Up to 95 % humidity (non-condensing).
•   10 years mean time before failure.




Innovatec Communications Confidential         Version 1.3                                   Page 7 of 9


Gateway Hardware Specification                                                            February 3, 2000



10. Block Diagram
The following diagram depicts the connections between the 5 different modules within the C & I Meter
enclosure.

                                                                  90 - 265 VAC




                                                    Power
                                                    Supply
                                                                          +3.6 and
                               +5 VDC
                                                                          +5 VDC
                                           +5 VDC            +5 VDC


                                 Wireless
                                                                       NCI
                                  Pager              RS232

                                                                                             Protection
                                                                         RS232
                                                                                               Circuit


    Telephone                      Telco                              Control
       Line                       Modem                               Module
                                                     PC104




The telco modem and the wireless pager are stuffing options. When one is installed the other isn’t
depending on the installation needs.




Innovatec Communications Confidential           Version 1.3                                     Page 8 of 9


Gateway Hardware Specification                                              February 3, 2000



Revision History

Revision    Description                                                          Date
  0.1       Preliminary release                                                08/30/99
  0.2       Released for review                                                09/02/99
  1.0       Production Release                                                 09/08/99
  1.1       Addition of Tamper Switch, Battery Backup and Power Recycling      10/20/99
  1.2       Deleted reference to the Harley Project                            01/26/00
  1.3       Changed Reference from Diablo to Innovatec                         02/03/00




Innovatec Communications Confidential      Version 1.3                           Page 9 of 9



Document Created: 2000-11-06 19:15:40
Document Modified: 2000-11-06 19:15:40

© 2024 FCC.report