RF Exposure (MPE)

FCC ID: OWS-NIC531-06

RF Exposure Info

Download: PDF
FCCID_4270818

MPE/RF EXPOSURE EVALUATION REPORT
                                FROM




          Evaluation of: Itron Inc NIC 531-0601
                                  to
  To: FCC CFR 47 Part 15 RF Exposure requirements
  Test Report Serial No.: ITRO18-U5 Rev A FCC MPE
              This report supersedes: NONE
                    Applicant:         Itron Networked Solutions, Inc.
                                       230 West Tasman Drive
                                       San Jose, California 95134
                                       USA
         Product Function:             Plug in radio device, mesh and
                                       HAN networks
                  Issue Date:          29th April 2019

    This Test Report is Issued Under the Authority of:

        MiCOM Labs, Inc.
        575 Boulder Court
        Pleasanton California 94566
        USA
        Phone: +1 (925) 462-0304
        Fax: +1 (925) 462-0306
        www.micomlabs.com

    MiCOM Labs is an ISO 17025 Accredited Testing Laboratory


                                                                              Title:         ITRON Inc. NIC 531-0601
                                                                                To:          FCC CFR 47 Part 1.1310
                                                                           Serial #:         ITRO18-U5 Rev A FCC MPE
                                                                        Issue Date:          29th April 2019
                                                                             Page:           2 of 4



1. MAXIMUM PERMISSABLE EXPOSURE
Calculations for Maximum Permissible Exposure Levels
                             2           2
Power Density = Pd (mW/cm ) = EIRP/(4*π*d )
EIRP = P * G
P = Peak output power (mW)
G = Antenna numeric gain (numeric)
d = Separation distance (cm)
Numeric Gain = 10 ^ (G (dBi)/10)

Because the EUT belongs to the General Population/Uncontrolled Exposure the limit of power density is 1
      2
mW/cm

These calculations represent worst case in terms of the exposure levels for the device.
                                    Peak
                  Ant   Numeric                 Peak     Calculated Power Power Density Min Calculated safe
  Freq. Band                       Output
                 Gain     Gain                 Output    Density (mW/cm2)       Limit    distance for Limit
    (MHz)                          Power
                 (dBi) (numeric)             Power (mW)      @ 20cm           (mW/cm2)          (cm)
                                   (dBm)
  902- 928
                  1.0     1.26     27.70       588.8          0.147              0.6           9.92
   (DSSS)
  902- 928
                  1.0     1.26     29.88       972.7          0.244              0.6           12.75
   (FHSS)
2400 - 2483.5     0.0      1.0     26.40       436.5           0.09              1.0           5.89


Note: for mobile or fixed location transmitters the minimum separation distance is 20cm, even if
calculations indicate the MPE distance to be less.




Specification
Maximum Permissible Exposure Limits


FCC §1.1310 Table 1 (B) Limits for General Population/Uncontrolled Exposure




              This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                         personnel. All changes will be noted in the Document History section of the report.

  MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


                                                                              Title:         ITRON Inc. NIC 531-0601
                                                                                To:          FCC CFR 47 Part 1.1310
                                                                           Serial #:         ITRO18-U5 Rev A FCC MPE
                                                                        Issue Date:          29th April 2019
                                                                             Page:           3 of 4


Specification - Maximum Permissible Exposure Limits

                            TABLE 1—LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
 Frequency range           Electric field strength         Magnetic field strength          Power density        Averaging time
      (MHz)                         (V/m)                          (A/m)                      (mW/cm2)             (minutes)

                                      (A) Limits for Occupational/Controlled Exposure

      0.3-3.0                       614                              1.63                        *100                    6
                                                                                                        2
      3.0-30                       1842/f                           4.89/f                     *900/f                    6
      30-300                        61.4                            0.163                         1.0                    6
    300-1,500                         --                               --                       f/300                    6
 1,500-100,000                        --                               --                          5                     6
                                 (B) Limits for General Population/Uncontrolled Exposure

     0.3-1.34                       614                              1.63                        *100                   30
                                                                                                        2
     1.34-30                        824/f                           2.19/f                     *180/f                   30
      30-300                        27.5                            0.073                         0.2                   30
    300-1,500                         --                               --                       f/1500                  30
 1,500-100,000                        --                               --                         1.0                   30

                                      f = frequency in MHz * = Plane-wave equivalent power density




              This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                         personnel. All changes will be noted in the Document History section of the report.

  MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


       575 Boulder Court
Pleasanton, California 94566, USA
     Tel: +1 (925) 462 0304
     Fax: +1 (925) 462 0306
      www.micomlabs.com



Document Created: 2019-05-11 00:07:02
Document Modified: 2019-05-11 00:07:02

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC