Users Manual

FCC ID: OWS-NIC511

Users Manual

Download: PDF
FCCID_1167105

     I-210+ NIC and Meter Labeling
              Product Requirements




Document Number 340-048002
 VERSION    DATE          AUTHOR        REVISIONS
   1.0     4/13/07        B. Gilbert    Initial version
   1.1     5/14/07        B. Gilbert    Change incorporates EUI-64 addressing
   1.2     8/4/2009     K. Thompson     Updated for SoC board and FCC IDs




                   Silver Spring Networks – Confidential and Proprietary
                                     NIC511User.doc


I-210+ NIC and Meter Labeling
Product Requirements




1 Introduction
The I-210+ NIC is a FCC Part 15.247 compliant device that enables communication between
Silver Spring Networks AMI network and the I-210+ family of meters. The NIC transmits in the
902 to 928 MHz, ISM band and transfers data from utility meter to Silver Spring Networks Relays
and Gateways.




1.1 References
   -   Guidelines for use of a 64-bit Extended Unique Identifier (EUI-64), IEEE Publication.


2 Meter Labeling
2.1 Meter Nameplate
The meter nameplate shall not contain information pertaining to the Silver Spring Networks
radio.

                        Figure 1 - Example of Meter Nameplate Label




                     Silver Spring Networks - Confidential and Proprietary
                                               2


I-210+ NIC and Meter Labeling
Product Requirements

2.2 Meter Auxiliary Label or NIC Address Label
For radio identification, the I-210+ meter shall have an auxiliary label containing the Silver
Spring Networks NIC address presented in text (16 alphanumeric digits) and barcode formats.

•   Bar Code Type = Code 3 of 9
•   Bar Code Font Size = unknown
•   Font Type = unknown
•   Font Size = unknown
•   Bar Code Label Dimensions = 1.50” x 0.25”
•   Bar Code Material Type = Static Dissipative Polyimide

The following figure is an example of the NIC address label, which is consistent with FCC
requirements set forth in section 4.1, and contain the Silver Spring Networks corporate name
and NIC EUI-64 address.


                           Figure 2 - Example of NIC Address Label
                                           Silver Spring Networks
                                              1234567890123456

                                Contains
                                 FCC ID: OWS-NIC511, IC: 5975A-NIC511


The NIC address label shall be place on the meter nameplate in the location identified by
“Label A” in the following figure.
NOTE: “Label B” location is not used.


                         Figure 3 – Nameplate NIC Address Locations




                     Silver Spring Networks - Confidential and Proprietary
                                               3


I-210+ NIC and Meter Labeling
Product Requirements


3 NIC Labeling
The SSN I-210+ NIC has two labels relevant to meter final assembly and RMA – the FCC & GE
Part Number label and the SSN NIC Address label. Both labels are located on the top side of the
NIC PCA. The barcode format is Code 3 of 9.
Figure 4 is an example of the FCC ID label that can be found in the location indicated in Figure
6. The size of the label is 1.5” x 1.0” inches. The barcode format is Code 3 of 9.

                              Figure 4 – FCC ID Label for NIC PCA



                                         GE PN 123S123456
                                         SSN PN 340-040301
                         FCC ID: OWS-NIC511              IC: 5975A-NIC511
                         This device complies with Part 15 of the FCC
                         Rules. Operation is subject to the following two
                         conditions: (1) this device may not cause harmful
                         interference, and (2) this device must accept any
                         interference received, including interference that
                         may cause undesired operation.
                                                               996-000015A


Figure 5 Figure 1is an example of the NIC address label that can be found in the location
indicated in Figure 6. The barcode format is Code 3 of 9.


                           Figure 5 – NIC Address Label for NIC PCA



                                        1234567890123456




                     Silver Spring Networks - Confidential and Proprietary
                                               4


I-210+ NIC and Meter Labeling
Product Requirements

                 Figure 6 – Label Locations on Top Side of I-210+ NIC PCA
     FCC Part
 Number Label
                                                         MAC Address
                                                         Label




                         Figure 7 – Bottom Side of I-210+ NIC PCA

                                                                            SSN Par Number




                                                                            MAC Address




4 FCC and Government Guidelines
                                Silver Spring Networks NIC
                          FCC ID: OWS-NIC507 IC: 5975A-NIC507



                    Silver Spring Networks - Confidential and Proprietary
                                              5


I-210+ NIC and Meter Labeling
Product Requirements

The I-210+ NIC is REQUIRED to be professionally installed by a properly trained technician.
Improper installation could void the user’s authority to operate the equipment.
The device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
1. The device may not cause harmful interference.
2. The device must accept any interference received, including interference that may cause
   undesired operation.


                          Figure 8 – Sample FCC ID Label for NIC PCA




                       FCC ID: OWS-NIC511                           IC: 5975A-NIC511
                       This device complies with Part 15 of the FCC Rules. Operation
                       is subject to the following two conditions: (1) this device may
                       not cause harmful interference, and (2) this device must
                       accept any interference received, including interference that
                       may cause undesired operation.




NOTE: For FCC compliance, the following text MUST be included in I-210+ and I-210+c
meter manuals and user’s guides.
The antenna of this transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
The device should be installed so that people will not come within 20 cm (8 in.) of the
antenna.
This equipment has been tested and found to comply with Part 15 of the FCC Rules. This
equipment generates, uses and can radiate radio frequency energy, and if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:

•   Reorient or relocate the receiving antenna.
•   Increase the separation between the equipment and receiver.
•   Connect the equipment into an outlet on a circuit different from that to which the receiver
    disconnected.
•   Consult the dealer or an experienced Radio/TV technician for help.

    CAUTION: Changes or modifications not expressly approved by Silver Spring Networks could
    void the user’s authority to operate the equipment.




                      Silver Spring Networks - Confidential and Proprietary
                                                6


I-210+ NIC and Meter Labeling
Product Requirements

4.1 FCC Guidelines for Devices Containing a Transmitter
    Module
The following is an extract from FCC PART 15 UNLICENSED MODULAR TRANSMITTER
APPROVAL, DA 00-1407, Released: June 26, 2000, Section 6 describing labeling
requirements for devices containing a modular transmitter.
        Section 6. The modular transmitter must be labeled with its own FCC ID
        number, and, if the FCC ID is not visible when the module is installed inside
        another device, then the outside of the device into which the module is
        installed must also display a label referring to the enclosed module. This
        exterior label can use wording such as the following: “Contains Transmitter
        Module FCC ID: XYZMODEL1” or “Contains FCC ID: XYZMODEL1.” Any similar
        wording that expresses the same meaning may be used. The Grantee may
        either provide such a label, an example of which must be included in the
        application for equipment authorization, or, must provide adequate
        instructions along with the module which explain this requirement.
In the latter case, a copy of these instructions must be included in the application for
equipment authorization."

                 Figure 9 – Sample FCC ID Label for Devices Containing a NIC




                           Contains FCC ID: OWS-NIC511, IC: 5975A-NIC511




4.2 Safety Information
WARNING!: Severe shock and explosion hazard! Touching energized parts can result in massive
equipment damage, and severe injury or death. Short-circuiting energized parts will result in
blinding flash and explosion. Opening and closing electrical circuits can also produce dangerous
and explosive arc flashes. Involuntary muscular reactions associated with electrical shock may
result in other injuries. Observe the following safety guidelines.
Careful planning of every job is essential. Nothing should be taken for granted. Do not take
chances!

•   Read and follow all approved policies and procedures provided by your employer associated
    with the procedures in this manual.
•   The procedures in this manual must only be performed by qualified workers in accordance
    with local utility safety practices, utility requirements, and applicable OSHA and NFPA
    standards.
•   The information contained in this document is intended to aid qualified personnel, and is
    not a replacement for the proper training required to make a person qualified.
•   Silver Spring Networks assumes no liability for the customer’s failure to follow these safety
    guidelines.




                      Silver Spring Networks - Confidential and Proprietary
                                                7


I-210+ NIC and Meter Labeling
Product Requirements

4.3 General Electrical Safety
•   Perform the procedures in this manual in accordance with applicable workplace standards
    established by the following agencies:

    •   Occupational Safety and Health Act (OSHA).
    •   The National Electrical Code published by the National Fire Protection Association
        (NFPA-70).
    •   National Electrical Manufacturers Association (NEMA).
    •   Electronics Industries Association (EIA).
    •   Insulated Power Cable Engineers Association (IPCEA).

•   American National Standards Institute (ANSI). Whenever possible, de-energize all circuits or
    equipment before working on them.
•   Maintain a minimum clearance of 10 ft. between line potential and all unqualified persons
    at all times.
•   Keep unauthorized people out of the work area. Be especially cautious of children, who
    tend to be drawn to work activity.
•   Determining if a circuit is OFF can be difficult in some instances. Check for circuit voltage
    with an appropriate voltmeter before working on equipment presumed to have been de-
    energized. Tiebreakers, double throw disconnect switches, automatic transfer switches and
    emergency generators can supply power through an alternate circuit or from another
    source.
•   120V current can be just a lethal as higher voltages because current flow through a body
    depends upon the body’s resistance.
•   Do not trust insulation and/or weatherproofing on a wire as protection from shock.
•   Use electrically insulated tools. Inspect portable electrical equipment or tools for defects
    and remove any defective devices from service immediately. All portable electrical
    equipment must have Ground Fault Circuit Interrupter (GFCI) protection.
•   Select the right tool for the job. Use tools properly. Keep tools in good working order.
•   Make sure the work area is free of any flammable material. Flammable vapors can be
    ignited by an arc flash.
•   Keep the work area clean and dry. Cluttered work areas cause accidents and injuries.
•   Provide good lighting in the work area. You cannot work safely if you cannot see what you
    are doing.
•   Report unsafe conditions or defective equipment to your immediate supervisor.
•   Handle material carefully. Lift and carry properly.


4.4 Personal Protective Equipment (PPE)
•   Always wear Personal Protective Equipment (PPE), in accordance with OSHA and ANSI
    standards.
•   Wear eye protection and electrically insulated gloves. Test gloves in accordance with ANSI
    standards before use. Do not use gloves that do not pass appropriate test procedures.
•   Wear protective clothing such as long sleeve shirts and long pants made of flame resistant
    materials.
•   Remove all jewelry.
•   Do not pass any objects to or from other persons not protected by insulating platforms or
    tested, electrically insulated gloves.


4.5 Fall Protection
When performing work at any elevation:

                     Silver Spring Networks - Confidential and Proprietary
                                               8


I-210+ NIC and Meter Labeling
Product Requirements

•   Always use a fall protection system, in accordance with OSHA standards, whenever
    performing work at any elevation.
•   Never use conductors, guy wires, pins, or cross-arm braces, etc. to support your weight.
•   Whenever using aerial lift devices such as hoists, man-lifts, vehicle-mounted work
    platforms and overhead lifts, read and follow the manufacturer’s guidelines for safe and
    proper operation.
•   Use ladders and scaffolding only in accordance with the manufacturer’s guidelines and/or
    according to OSHA standards.
•   Only use ladders made of non-metallic, non-conductive material. They should be the
    proper size and type for the work intended. Inspect ladders for wear and breakage.
    Remove any oil, grease, or other slippery materials.
•   Do not set the ladder at too steep or too shallow of an angle. A rule of thumb is to stand
    erect with your toes against the bottom rails of the ladder, with your arms extended
    straight out. If you can set your palms on top of the rung that is at eye level, the ladder
    should be at the proper angle. If a ladder angle label is provided, follow its
    recommendations.
•   If the ladder is to remain in place for an extended period, secure it at the top. The support
    point at the top of the ladder should be at least 24 inches (60 centimeters) wide to
    maintain support in the event of sideways movement. For jobs of short duration, have a
    fellow worker support the ladder at the base.
•   Evaluate all tasks to be performed from a ladder for potential fall hazards, such as complex
    tasks or situations that require leaning from the side of the ladder.
•   The use of scaffolding or a work platform should be considered as an alternative solution in
    such cases.


4.6 Shock Accident First Aid
•   Do not touch the victim with your bare hands; use something non-conductive to separate
    the victim from the energy source.
•   Call for emergency medical help immediately. Keep the victim lying down, warm, and
    comfortable until help arrives. Avoid moving the victim in case of injury to neck or back.
    Position an unconscious victim on a side to let fluids drain.
•   Check the victim’s breathing and heartbeat. If properly trained, apply mouth-to-mouth
    resuscitation and/or CPR if necessary.
•   Remove constricting items from the victim, such as shoes, belts, jewelry, and tight collars;
    they could cut off circulation if the victim experiences swelling.
•   Apply water or saline for a few minutes to any burns until the skin returns to normal
    temperature. Do not attempt to remove clothing that is stuck to a burn. If possible,
    elevate burned areas to reduce swelling.
•   Make sure the victim receives professional medical attention, even if they feel fine.
    Electric shock can cause heart failure hours after the shock is received.




                     Silver Spring Networks - Confidential and Proprietary
                                               9



Document Created: 2009-08-20 11:46:26
Document Modified: 2009-08-20 11:46:26

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC