MPE calculation

FCC ID: OWS-NIC511-LTE

RF Exposure Info

Download: PDF
FCCID_3314835

   Company: Silver Spring Networks

       Evaluation of: MicroAP 5
     To: FCC CFR 47 Part 1.1310

Report No.: SSNT135_MPE Rev A Report




           MPE REPORT


              MPE TEST REPORT
                              FROM




  Evaluation of: Silver Spring Networks MicroAP 5
                          to
             To: FCC CFR 47 Part 1.1310
Test Report Serial No.: SSNT135-MPE Rev A Report
            This report supersedes: NONE

                  Applicant:        Silver Spring Networks
                                    230 W Tasman Drive
                                    San Jose, California 95134
                                    USA
       Product Function:            Plug in Radio Device
                Issue Date:         3rd Feb 2017


  This Test Report is Issued Under the Authority of:

      MiCOM Labs, Inc.
      575 Boulder Court
      Pleasanton California 94566
      USA
      Phone: +1 (925) 462-0304
      Fax: +1 (925) 462-0306
      www.micomlabs.com

     MiCOM Labs is an ISO 17025 Accredited Testing Laboratory


  1. MAXIMUM PERMISSABLE EXPOSURE
  Calculations for Maximum Permissible Exposure Levels
  Power Density = Pd (mW/cm 2) = EIRP/(4*π*d2)
  EIRP = P * G
  P = Peak output power (mW)
  G = Antenna numeric gain (numeric)
  d = Separation distance (cm)
  Numeric Gain = 10 ^ (G (dBi)/10)


  The calculations in the table below use the highest conducted power values together with the lowest
  antenna gain specified for the EUT. These calculations represent worst case in terms of the exposure
  levels.


                                          Peak        Peak     Source Based   Calculated  Limit of Power
                   Ant      Numeric
 Freq. Band                              Output      Output    Time Average Power Density    Density
                  Gain       Gain
   (MHz)                                 Power       Power      Correction   (mW/cm2) @    (mW/cm2) @
                  (dBi)    (numeric)
                                         (dBm)        (mW)         (dB)         20cm          20cm
  902 - 925        1.2        1.32         30         1000           0          0.262         0.601
 2400 - 2483.5     5.6        3.63          27       501.19             0            0.362               1
LTE FDD Band
                   3.5        2.24          24       251.19             -12          0.007               1
       II
LTE FDD Band
                    1         1.26          24       251.19             -12          0.004           0.551
       V


  Assessment for simultaneous operation Scenarios:

      1. 900 MHz and 2.4GHz and LTE band II

  Total Evaluation: (0.262/0.601) + (0.362/1) + (0.007/1) = 0.805 ≤ 1


      2. 900 MHz and 2.4GHz and LTE band V

  Total Evaluation: (0.262/0.601) + (0.362/1) + (0.004/1) = 0.805 ≤ 1


  Note: for mobile or fixed location transmitters the minimum separation distance is 20cm, even if
  calculations indicate the MPE distance to be less.

  Specification
  Maximum Permissible Exposure Limits



  FCC §1.1310 Limit = 1.310 Table 1


       575 Boulder Court
Pleasanton, California 94566, USA
     Tel: +1 (925) 462 0304
     Fax: +1 (925) 462 0306
      www.micomlabs.com



Document Created: 2017-02-08 15:33:19
Document Modified: 2017-02-08 15:33:19

© 2024 FCC.report