                                                                                                      Evaluation of RF Exposure
                                                                                                                                                                                                  Date:       3/20/2014
                                       Part Number: 174-0395-00                                                                                                                                  FCC ID: OWS-NIC441
                                        Description: NIC 441-0702
                                         Frequency: 902 - 928 MHz FHSS, 2400-2483.5 FHSS

                                                          900 MHz          2400 MHz
Max RF Power                                                       29.82                       24.5   dBm
Source Based Time Average Correction                                   0                          0   dB
Tx Antenna                                                             3                          4   dBi
EIRP                                                               32.82                       28.5   dBm
EIRP                                                        1914.255925                707.9457844    mW
EIRP                                                        1.914255925                0.707945784    W
MPE dist                                                                      20                      cm

                                                               EIRP
Equation 1 -                                              S=
                                                               4πR 2

                                                                 EIRP
Equation 2 -                                              R=
                                                                 4πS
OET Bulletin No. 65, Supplement C
Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields.
Appendix A: FCC Exposure Criteria, FCC Limits for Maximum Permissible Exposure (MPE)
                                                                                                                                     Limit                                                       Calculated
                                                                                                            Smax, occupational                 Smax, general public        S, mW/cm2      S, mW/cm2      Rmin, occupational   Rmin, general public
                         Radio                                 F(MHz)           Actual F, MHz           Controlled, Ave 6 min             Uncontrolled, Ave 30 min         @ 20cm dist    @ 20 cm dist
                                                                                                              mW/cm2                              mW/cm2                    mW/cm2         mW/cm2                 cm                 cm
                                                          0.3-1.34*                    --                      100                                 100                --                                           --                 --
                                                          1.34-30                    --                        900/f2                             180/f2              --                                         --                --
                                                          30-300                     --                          1                                  0.2               --                                         --                --
900FHSS                                                   300-1500                  902                     3.006666667                        0.601333333                  0.380829116    0.380829116        7.117908921       15.9161282
2400FHSS                                                  1500-100,000             2400.8                        5                                   1                      0.140841339    0.140841339        3.356680965      7.505766817
* upper frequency range is 3 MHz for occupational limit
NOTE: For mobile or fixed location transmitters, minimum separation distance for FCC compliance is 20 cm, even if calculations indicate MPE distance is less


                                                                           % 900 MHz RFx                                         63.33%
                                                                           % 2.4 GHz RFx                                         14.08%

                                                                           Total RFx                                             77.41%