MPE

FCC ID: OWS-NIC44

RF Exposure Info

Download: PDF
FCCID_1915743

                                                                                     Sheet1




Silver Spring Networks
FCC ID: OWS-NIC44
896 - 928 MHz                                                                                  Calculate mW/cm2 here. Enter frequency in MHz:
Electric Meter Mesh Network Radio
RF Hazard Distance Calculation                                                                 Calculation of Limits from 1.1310 Table 1
                                                                                                                                                Controlled      Uncontrolled
                                                                                                                                                Ave 6 min       Ave 30 min
mW/cm2 from Table1:                 0.60                                                            F(MHz)         Actual F, MHz                 Occ, mW/c2     Gen, mW/cm2
                                                                                                     0.3-3             0.5                          100.0           100.0
Max RF Power TX Antenna       MPE distance   S, mW/cm@         Comment                             3.0 - 30.0            5                          180.0            36.0
P, dBm       G, dBi           cm             at MPE distance                                       30.0-300             55                           1.0             0.2
                                                                                                   300-1500            896                           3.0             0.60
    29.95            6.00           22.8          0.6000                                         1500-100000          5555                           5.0             1.0


                                                                                               Enter P(mW)        Equivalent dBm Enter dBm      Equivalent Watts




Basis of Calculations:                                                                         895.4              29.52            29.52                895.4

E^2/3770 = S, mW/cm2
E, V/m = (Pwatts*Ggain*30)^.5/d, meters
d = ((Pwatts*G*30)/3770*S))^0.5                Pwatts*Ggain = 10^(PdBm-30+GdBi)/10)
S@20cm = 20 log (MPE dist/20cm)
NOTE: For mobile or fixed location transmitters, minimum separation distance is for FCC compliance is 20 cm,
         even if calculations indicate MPE distance is less




                                                                                      Page 1



Document Created: 0260-10-22 00:00:00
Document Modified: 0260-10-22 00:00:00

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC