Test Report_NIC42ACline

FCC ID: OWS-NIC42

Test Report

Download: PDF
FCCID_1971978

Silver Spring Networks                                             Report No: 13PRO006
FCC ID: OWS-NIC42
IC: 5975A-NIC42                                                       Model No.: NIC42

AC LINE CONDUCTED EMISSIONS TEST REPORT FOR A
LOW POWER TRANSMITTER

I. GENERAL INFORMATION

Requirement:             FCC
Test Requirements:       FCC Part 15

Applicant:               Silver Spring Networks
                         575 Broadway Street
                         Redwood City, CA 94063

FCC ID:                  OWS-NIC42
IC:                      5975A-NIC42
Model No.:               NIC42


II. DESCRIPTION OF EQUIPMENT UNDER TEST (EUT)

The Silver Spring Networks (SSN) model NIC42 is an access point for electric power
meter communications use. The radio incorporates a dual band 900 MHz/ 2.4 GHz
frequency hopping mesh network radio. Test data for 900 MHz FHSS operation are
provided in a separate report.

III. TEST DATES AND TEST LOCATION

Testing was performed on 10 May 2013 at

BACL Laboratories
1274 Anvilwood Ave.
Sunnyvale, CA 94089




T.N. Cokenias                                                   16 May 2013
EMC Consultant/Agent for Silver Spring Networks




                                       Page 1 of 8


Silver Spring Networks                                                Report No: 13PRO006
FCC ID: OWS-NIC42
IC: 5975A-NIC42                                                          Model No.: NIC42
TEST PROCEDURES

All tests were performed in accordance with the applicable procedures called out in the
following documents, unless otherwise noted:

FCC 47CFR15

DA 00-705: Filing and Measurement Guidelines for Frequency Hopping Spread
Spectrum Systems

RSS-Gen Issue 3: General Requirements and Information for the Certification of Radio
Apparatus

RSS-210 Issue 8: Low power license exempt radio frequency devices (December 2010)
RSS-212: Test Facilities and Test Methods for Radio Equipment

ANSI C63.4 – 2003, American National Standard for Methods of Measurement of Radio-
Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of
9 kHz to 40 GHz.

Laboratory Accreditation Information

BACL
2.948 FCC Registration Number: 90464
Industry Canada Test Site Registration Number: 3062A
Accrediting Body: A2LA




                                            Page 2 of 8


Silver Spring Networks                                                         Report No: 13PRO006
FCC ID: OWS-NIC42
IC: 5975A-NIC42                                                                   Model No.: NIC42




Test Equipment List


  Manufacturer              Description               Model No.        Serial No.      Calibration Due
 Rohde & Schwarz          EMI Test Receiver       ESCI 1166.5950K03     100337            2014-04-23
   Solar Electronics              LISN             9252-R-24-BNC         511205           2013-06-25

	
  
	
  
	
  	
  
	
  
                                              laptop
                       Serial cable
            EUT




                                                                          120 VAC
           LISN

                                               EMI
                                               Test
                                               Receiver



Support Equipment

Equipment              Mfr                Model                    Asset No.
Laptop PC              Dell               PP01L                    TW-0791UH1280-
                                                                   OC9-6558
AC/DC adapter          CUI Inc.           DSA-60W-20               2607HB




                                              Page 3 of 8


Silver Spring Networks                                                 Report No: 13PRO006
FCC ID: OWS-NIC42
IC: 5975A-NIC42                                                            Model No.: NIC42
    4.4 POWERLINE CONDUCTED EMISSIONS
LIMIT


§15.207 (a) Except as shown in paragraphs (b) and (c) of this section, for an intentional
radiator that is designed to be connected to the public utility (AC) power line, the radio
frequency voltage that is conducted back onto the AC power line on any frequency or
frequencies within the band 150 kHz to 30 MHz shall not exceed the limits in the
following table, as measured using a 50 µH/50 ohms line impedance stabilization
network (LISN). Compliance with the provisions of this paragraph shall be based on the
measurement of the radio frequency voltage between each power line and ground at the
power terminal.

The lower limit applies at the boundary between the frequency ranges.




TEST PROCEDURE


The EUT is placed on a non-conducting table 40 cm from the vertical ground plane and
80 cm above the horizontal ground plane. The EUT is configured in accordance with ANSI
C63.4.

The resolution bandwidth is set to 9 kHz for both peak detection and quasi-peak detection
measurements. Peak detection is used unless otherwise noted as quasi-peak.

The transmitter was configured to simultaneously transmit FHSS mode in the 902 MHz
and 2.4 GHz bands simultaneously, since this is the worst-case operation (maximum
output power) for simultaneous operation.

Line conducted data is recorded for both NEUTRAL and HOT lines.


RESULTS


No non-compliance noted:




                                        Page 4 of 8


Silver Spring Networks                     Report No: 13PRO006
FCC ID: OWS-NIC42
IC: 5975A-NIC42                               Model No.: NIC42
Hot AC Conducted Emissions




                             Page 5 of 8


Silver Spring Networks                              Report No: 13PRO006
FCC ID: OWS-NIC42
IC: 5975A-NIC42                                        Model No.: NIC42

Neutral AC Line Conducted Emissions




                                      Page 6 of 8


Silver Spring Networks                                                                            Report No: 13PRO006
FCC ID: OWS-NIC42
IC: 5975A-NIC42                                                                                         Model No.: NIC42

Tabulated worst case AC line conducted data
Vasona Data : Formally Assessed Peaks
No           Frequency MHz Raw dBuV      Cable Loss   Factors dB    Level dBuV     Measurement   Line
                                                                                                 Type        Limit dBuV   Margin dB    Pass /Fail
           1     0.163804         31.44         10.09          1.09        42.62   Quasi Peak    Live               65.27       -22.64 Pass
           2     0.184949         31.96          9.82          1.05        42.82   Quasi Peak    Live               64.26       -21.44 Pass
           3     0.210371         23.21          9.76             1        33.97   Quasi Peak    Live               63.19       -29.22 Pass
           4     0.150244         42.94         11.95          1.12        56.01   Quasi Peak    Live               65.99        -9.97 Pass
           5     0.277799         34.11          9.68          0.88        44.67   Quasi Peak    Live               60.88       -16.21 Pass
           6     0.333564         29.71          9.67          0.39        39.77   Quasi Peak    Live               59.36        -19.6 Pass
           7     0.163804          4.26         10.09          1.09        15.44   Average       Live               55.27       -39.83 Pass
           8     0.184949         20.41          9.82          1.05        31.28   Average       Live               54.26       -22.98 Pass
           9     0.210371          5.04          9.76             1        15.79   Average       Live               53.19        -37.4 Pass
          10     0.150244         14.57         11.95          1.12        27.64   Average       Live               55.99       -28.35 Pass
          11     0.277799            4.5         9.68          0.88        15.07   Average       Live               50.88       -35.81 Pass
          12     0.333564          2.07          9.67          0.39        12.12   Average       Live               49.36       -37.24 Pass

Vasona Data : Formally Assessed Peaks
No           Frequency MHz Raw dBuV     Cable Loss   Factors dB    Level dBuV      Measurement   Line
                                                                                                 Type        Limit dBuV   Margin dB    Pass /Fail
           1     0.155837         42.31        10.92          1.11        54.34    Quasi Peak    Neutral            65.68       -11.35 Pass
           2     0.465393         38.32         9.69          0.22        48.22    Quasi Peak    Neutral             56.6        -8.37 Pass
           3     0.191433         40.19          9.8          1.04        51.02    Quasi Peak    Neutral            63.97       -12.95 Pass
           4     0.469572         39.08         9.69          0.22        48.99    Quasi Peak    Neutral            56.52        -7.53 Pass
           5     0.450314         39.26         9.69          0.22        49.17    Quasi Peak    Neutral            56.87         -7.7 Pass
           6     0.483632         38.49         9.69          0.21        48.39    Quasi Peak    Neutral            56.28        -7.88 Pass
           7     0.155837         12.12        10.92          1.11        24.15    Average       Neutral            55.68       -31.54 Pass
           8     0.465393         17.98         9.69          0.22        27.88    Average       Neutral             46.6       -18.71 Pass
           9     0.191433         20.87          9.8          1.04         31.7    Average       Neutral            53.97       -22.27 Pass
          10     0.469572         21.23         9.69          0.22        31.14    Average       Neutral            46.52       -15.38 Pass
          11     0.450314         22.45         9.69          0.22        32.36    Average       Neutral            46.87       -14.51 Pass
          12     0.483632         22.23         9.69          0.21        32.14    Average       Neutral            46.28       -14.14 Pass




                                                      Page 7 of 8


Silver Spring Networks                                                     Report No: 13PRO006
FCC ID: OWS-NIC42
IC: 5975A-NIC42                                                               Model No.: NIC42




                                     END OF REPORT


Report Revision History


 Revision     Revision Description                 Pages     Revised by            Date
   No.                                             Revised
    -         Original issue                                 T. Cokenias           16 May 2013




                                         Page 8 of 8



Document Created: 1030-11-08 00:00:00
Document Modified: 1030-11-08 00:00:00

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC