RF Exposure Report

FCC ID: OWS-MIL51

RF Exposure Info

Download: PDF
FCCID_3405435

MPE/RF EXPOSURE EVALUATION REPORT
                                FROM




      Evaluation of: Silver Spring Networks LNIC
                                  to
  To: FCC CFR 47 Part 15 RF Exposure requirements
     Test Report Serial No.: SSNT136 MPE Rev A
              This report supersedes: NONE
                    Applicant:         Silver Spring Networks
                                       230 W Tasman Dr
                                       San Jose, California 95134
                                       USA
         Product Function:             Modular radio device, will
                                       communicate over 900 MHz.
                  Issue Date:          3rd May 2017


    This Test Report is Issued Under the Authority of:

        MiCOM Labs, Inc.
        575 Boulder Court
        Pleasanton California 94566
        USA
        Phone: +1 (925) 462-0304
        Fax: +1 (925) 462-0306
        www.micomlabs.com

    MiCOM Labs is an ISO 17025 Accredited Testing Laboratory


                                                                              Title:         Silver Spring Networks LNIC
                                                                                To:          FCC CFR 47 Part 1.1310
                                                                           Serial #:         SSNT136 MPE
                                                                        Issue Date:          3rd May 2017
                                                                             Page:           2 of 3



1. MAXIMUM PERMISSABLE EXPOSURE
Calculations for Maximum Permissible Exposure Levels
Power Density = Pd (mW/cm ) = EIRP/(4*π*d )
                             2           2

EIRP = P * G
P = Peak output power (mW)
G = Antenna numeric gain (numeric)
d = Separation distance (cm)
Numeric Gain = 10 ^ (G (dBi)/10)

Because the EUT belongs to the General Population/Uncontrolled Exposure the limit of power density is
          2
0.6 mW/cm

These calculations represent worst case in terms of the exposure levels.
                                             Peak         Peak      Calculated Calculated Minimum
                     Ant    Numeric
   Freq. Band                              Output        Output        Safe      Power    Separation
                    Gain      Gain
     (MHz)                                 Power         Power     Distance @ Density @ Distance
                    (dBi) (numeric)                                           2
                                            (dBm)         (mW)     0.6 mW/cm     20cm        (cm)
  902.0 – 928.0      0.0      1.00           23.77       238.23        5.62      0.047       20.0


Note: for mobile or fixed location transmitters the minimum separation distance is 20cm, even if
calculations indicate the MPE distance to be less.




Specification
Maximum Permissible Exposure Limits



FCC §1.1310 Limit = f/1500 from 1.310 Table 1 for devices operating in the 900 MHz band, where f =
frequency in MHz




              This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                         personnel. All changes will be noted in the Document History section of the report.

  MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


       575 Boulder Court
Pleasanton, California 94566, USA
     Tel: +1 (925) 462 0304
     Fax: +1 (925) 462 0306
      www.micomlabs.com



Document Created: 2017-10-23 23:56:32
Document Modified: 2017-10-23 23:56:32

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC