RF Exposure

FCC ID: OWS-MIL51

RF Exposure Info

Download: PDF
FCCID_3244869

        Company: Silver Spring Networks

              Evaluation of; Milli 5

To: FCC CFR 47 Part 15 RF Exposure requirements

           Report No.: SSNT122 MPE




             MPE TEST REPORT


               MPE TEST REPORT
                              FROM




    Evaluation of: Silver Spring Networks Milli 5
                                to
To: FCC CFR 47 Part 15 RF Exposure requirements
       Test Report Serial No.: SSNT122 MPE
            This report supersedes: NONE
                  Applicant:         Silver Spring Networks
                                     230 W Tasman Dr
                                     San Jose, California 95134
                                     USA
       Product Function:             900 MHz Radio Device
                Issue Date:          20th September 2016


  This Test Report is Issued Under the Authority of:

      MiCOM Labs, Inc.
      575 Boulder Court
      Pleasanton California 94566
      USA
      Phone: +1 (925) 462-0304
      Fax: +1 (925) 462-0306
      www.micomlabs.com

  MiCOM Labs is an ISO 17025 Accredited Testing Laboratory


                                                                              Title:         Silver Spring Networks Milli 5
                                                                                To:          FCC CFR 47 Part 15
                                                                           Serial #:         SSNT122 MPE
                                                                        Issue Date:          20th September 2016
                                                                             Page:           3 of 4




1. MAXIMUM PERMISSABLE EXPOSURE
Calculations for Maximum Permissible Exposure Levels
Power Density = Pd (mW/cm ) = EIRP/(4*π*d )
                             2           2

EIRP = P * G
P = Peak output power (mW)
G = Antenna numeric gain (numeric)
d = Separation distance (cm)
Numeric Gain = 10 ^ (G (dBi)/10)

Because the EUT belongs to the General Population/Uncontrolled Exposure the limit of power density is
          2
0.6 mW/cm

The calculations in the table below use the highest conducted power values together with the lowest
antenna gain specified for the EUT. These calculations represent worst case in terms of the exposure
levels.
                                             Peak         Peak     Calculated Calculated Minimum
                      Ant     Numeric
   Freq. Band                               Output       Output        Safe        Power       Separation
                     Gain       Gain
      (MHz)                                 Power        Power     Distance @ Density @ Distance
                     (dBi) (numeric)                                           2
                                            (dBm)         (mW)    0.6 mW/cm         20cm          (cm)
  902.0 – 928.0       3.0       2.00         23.77       238.23        7.94          0.09         20.0


Note: for mobile or fixed location transmitters the minimum separation distance is 20cm, even if
calculations indicate the MPE distance to be less.




Specification
Maximum Permissible Exposure Limits



                                        2
FCC §1.1310 Limit = 1mW / cm from 1.310 Table 1




              This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                         personnel. All changes will be noted in the Document History section of the report.

  MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com