Gas IMU Installation
 and Configuration
                                2009




       innovation in utility networking


                                                       Overview
   • Remove existing index and prepare the meter

   • Attach the tamper magnet holder

   • Attach the index to the IMU

   • Attach the IMU assembly to the meter

   • Prepare IMU for programming




© 2010 Silver Spring Networks | Company Confidential              2


                                                       Safety First!



   • Always follow applicable standards for safety!

   • Refer to the meter documentation for further safety information.

   • Follow your employer’s best practices.

   • If you smell gas, report it to the utility.

   • Do not use power tools!




© 2010 Silver Spring Networks | Company Confidential                    3


                                                 RF Exposure Notice (509)
   • The antenna of this transmitter must not be co-located or operating in conjunction with any other antenna
     or transmitter.

   • The device should be installed so that people will not come within 20 cm (8 in.) of the antenna.

   • This equipment has been tested and found to comply with Part 15 of the FCC Rules, and with Industry
     Canada licence-exempt RSS standard(s). This equipment generates, uses and can radiate radio frequency
     energy, and if not installed and used in accordance with the instructions, may cause harmful interference
     to radio communications. However, there is no guarantee that interference will not occur in a particular
     installation. If this equipment does cause harmful interference to radio or television reception, which can
     be determined by turning the equipment off and on, the user is encouraged to try to correct the
     interference by one or more of the following measures:

   • Reorient or relocate the receiving antenna.

   • Increase the separation between the equipment and receiver.

   • Connect the equipment into an outlet on a circuit different from that to which the receiver disconnected.

   • Consult the dealer or an experienced Radio/TV technician for help.
                                                         Modifications to the IMU not
                                                  expressly approved by Silver Spring Networks
                                                   may void your authority to operate the IMU.


© 2010 Silver Spring Networks | Company Confidential                                                               4


                                                       Components and Tools
   • Components:
                                           Component              Qty.   Size             Part Numbers

                                           SSN IMU                1      n/a              221-010001 (Am)
                                                                                          222-010001 (RW)
                                           Index cover            1      n/a              976-000195 (Am)
                                                                                          976-000196 (RW)
                                           Index cover screws     4      -20” x 21/4”    901-000052 (Am)
                                                                         10-24 x 21/4”    901-000053 (RW)
                                           Index screws           2      8-32 x 3/16”     901-000054 (Am)
                                                                         6-32 x 3/4”      901-000057 (RW)
                                           Red tamper seals       2      n/a              976-000204

                                           Tamper magnet holder   1      n/a              976-000212 (Am)
                                           & magnet                                       976-000213 (RW)
   • Tools:
         –     Flathead screw driver
         –     Phillips screw driver
         –     Nut driver
         –     Awl, scraper, wire brush
         –     Service magnet
                                                                         Service magnet

© 2010 Silver Spring Networks | Company Confidential                                                        5


                                                       Components (cont.)

                                Index cover
        Tamper                    screws
         seals

                                                         Index
                                                         cover               Tamper magnet holder
                                                       (American)           with magnet for American


              Index
             screws




                                                                             Tamper magnet holder
                                                                            and magnet for Rockwell



                               Service magnet




© 2010 Silver Spring Networks | Company Confidential                                                   6


                                                       Schematic (American)
                                                                  Tamper magnet

                                                                                       Tamper magnet holder
                                                                                          (for American)




                                                                   IMU



                                                          Index

                                                                           Battery
          Index cover
                                                                         compartment
            screws

                                                  Index
                                                  cover

                                                                     Index
                                                                    screws



                                             Tamper seals


© 2010 Silver Spring Networks | Company Confidential                                                          7


                                                       Schematic (Rockwell)
                                                            Tamper magnet holder
                                                          and magnet (for Rockwell)




                                                                         IMU


                                                                                 Battery
                                                                               compartment
                         Index cover                      Index
                           screws


                                                  Index               Index
                                                  cover              screws



                                         Tamper seals




© 2010 Silver Spring Networks | Company Confidential                                         8


                               Remove Existing Cover & Prep Meter
   • Remove the existing index cover
     and index from the meter.




   • Clean the meter index area
     and make sure to remove
     any remaining parts
     of the old gasket.




© 2010 Silver Spring Networks | Company Confidential                9


                                   Attach the Tamper Magnet Holder
   • On an American meter,
     attach the magnet so that
     the protrusion holding the
     magnet points down and to
     the left and the gap in the
     circle fits around the
     notch on the meter.



                                                                       American



   • On a Rockwell meter, attach the
                                                       American
     magnet holder so that the
     protrusion holding the magnet
     points down and to the left and
     the inner pin is inserted into
     the index screw hole.
                                                                                  American
                                                                  Rockwell


© 2010 Silver Spring Networks | Company Confidential                                         10


                                               Attach Meter Index to IMU
   • Align the IMU drive train
     with the index wriggler.




                                       IMU Drive Train




                                                            Index Wriggler



© 2010 Silver Spring Networks | Company Confidential                         11


                                   Attach Meter Index to IMU (cont.)
   • Use the two index screws
     to firmly attach the index
     to the IMU.

   • Torque:
         –     Rockwell: 13-15 inch pounds
         –     American: 14-17 inch pounds




   • Rotate the IMU drive train two turns,
     clockwise or counter-clockwise
     to ensure it spins freely.



© 2010 Silver Spring Networks | Company Confidential                   12


                                         Attach IMU Assembly to Meter
   • Insert the four cover screws
     through the index cover
     and set the cover down.




   • Attach the IMU assembly to
     the meter so that the drive
     train aligns with the meter
     wriggler and the screw
     holes on the meter align
     with those on the cover.


© 2010 Silver Spring Networks | Company Confidential                    13


                              Attach IMU Assembly to Meter (cont.)
   • While holding the enclosure
     against the meter to
     maintain proper alignment,
     rotate the test hand to
     verify proper engagement.

   • Attach the index cover and
     screws to the meter.

   • Torque:
         – Rockwell: 17-20 inch pounds
         – American: 25-35 inch pounds




   • Tighten the four screws firmly.

   • Use the nut driver to push the
     two red tamper seals into place.


© 2010 Silver Spring Networks | Company Confidential                 14


                                   Prepare the IMU for Programming
   • Slowly pass the service magnet once (for 2 to 5 seconds) over the top of the IMU.

   • Doing so wakes up the IMU, enabling you to program it.




© 2010 Silver Spring Networks | Company Confidential                                     15


      Rockwell 415
Gas IMU Installation
 and Configuration
                        August 2010




       innovation in utility networking


                                                Rockwell 415 IMU Retrofit

   Overview
   • Check the components and tools list.

   • Remove the index cover and index.

   • Fasten the adapter plate to the meter.

   • Fasten the meter index to the IMU.

   • Fasten the IMU to the meter.

   • Fasten the index lens cover and the tamper seal.

   • Prepare the IMU for programming.




© 2010 Silver Spring Networks | Company Confidential                        17


                              Check the Components and Tools List

      • Components:                        Component                 Qty.    Size              Part Numbers

                                           Silver Spring Networks    1       n/a               178-000101 rev 06
                                           IMU
                                           Adapter system            1       n/a               178-000098 rev 02

                                           Index cover               1       n/a               976-000196 rev 1

                                           Index cover screws        4       10-24 X 2.75” L   901-000061 rev 01

                                           Index screws              3       6-32 X ” L       901-000063 rev 01

                                           Red tamper seals          3       n/a               976-000203 rev 1

      • Tools:
            –     Flathead screw driver                   Awl, scraper, wire brush
            –     Phillips screw driver                   Service magnet
            –     Nut driver




                                                                              Service magnet

© 2010 Silver Spring Networks | Company Confidential                                                               18


           Check the Components and Tools List (continued)




                                               IMU                          Index cover

              Tamper seals




                               Index screws            Index cover screws        Adapter plate




                                                        Service magnet


© 2010 Silver Spring Networks | Company Confidential                                             19


                Check the components and tools list (continued)

    Rockwell 415
     schematic




© 2010 Silver Spring Networks | Company Confidential              20


                                 Remove the Index Cover and Index
   1. Remove the existing index
      cover and index from the meter.




   2. Clean the meter index area
      and make sure to remove
      any remaining parts of the
      old gasket.




© 2010 Silver Spring Networks | Company Confidential                21


                              Fasten the Adapter Plate to the Meter


      1. Position the adapter plate pin
         into the center left hole on the
         meter and seat the adapter
         onto the meter.




      2. Position an index screw in the
         center right hole and fasten
         the adapter using 7-8 in-lbs of
         torque.




© 2010 Silver Spring Networks | Company Confidential                  22


           Fasten the Adapter Plate to the Meter (continued)
      4. Rotate the gear on the plate clockwise until you feel it engage with the
         gear inside the IMU. Make sure that the gears are not locked up.




© 2010 Silver Spring Networks | Company Confidential                                23


                                  Fasten the Meter Index to the IMU
      1. Attach the meter index to the IMU with
         two index screws using 7-8 in-lbs of
         torque.




      2. Make sure that the gears engage by
         moving the lower dial.




© 2010 Silver Spring Networks | Company Confidential                  24


                                            Fasten the IMU to the meter

                 1. Angling in from the left, seat the
                    IMU on the adapter plate on the
                    meter. Adjust the rear gasket as
                    needed and make sure that the
                    gears are engaged but not locked
                    up.




                 2. Rotate the lower dial to make
                    sure it is engaged with the gear
                    on the adapter.




© 2010 Silver Spring Networks | Company Confidential                      25


            Fasten the index lens cover and the tamper seals
      1. Fasten the lens cover and the IMU
         to the meter using the four long lens
         cover screws and a torque of 13-15
         in-lbs.




      2. Use a nut driver to push the three
         tamper seals into the openings on
         the IMU.




© 2010 Silver Spring Networks | Company Confidential           26


                                   Prepare the IMU for Programming

    Slowly pass the service magnet once (for 2 to 5 seconds) over the top of the IMU.

    This activates the IMU so you can program it.




© 2010 Silver Spring Networks | Company Confidential                                    27