User Manual (Installation)

FCC ID: OWS-IMU516

Users Manual

Download: PDF
FCCID_1459822

    Single Channel Rotary and
Turbine Meter IMU Installation
                                 April 6, 2011




                 innovation in utility networking


                                                       Overview


   • Connect the pulser and IMU cables

   • Connect the IMU battery cable

   • Configure the IMU for field use

   • Attach the mounting plate and the cover to the IMU enclosure

   • Attach the IMU and mounting plate to the pipe or wall




© 2010 Silver Spring Networks | Company Confidential                2


                                                       Safety First!



   • Always follow applicable standards for safety!

   • Refer to the meter documentation for further safety information.

   • Follow your employer’s best practices.

   • If you smell gas, report it to the utility.

   • Do not use power tools!




© 2010 Silver Spring Networks | Company Confidential                    3


                                                 RF Exposure Notice (509)
   • The antenna of this transmitter must not be co-located or operating in conjunction with any other antenna
     or transmitter.

   • The device should be installed so that people will not come within 20 cm (8 in.) of the antenna.

   • This equipment has been tested and found to comply with Part 15 of the FCC Rules, and with Industry
     Canada licence-exempt RSS standard(s). This equipment generates, uses and can radiate radio frequency
     energy, and if not installed and used in accordance with the instructions, may cause harmful interference
     to radio communications. However, there is no guarantee that interference will not occur in a particular
     installation. If this equipment does cause harmful interference to radio or television reception, which can
     be determined by turning the equipment off and on, the user is encouraged to try to correct the
     interference by one or more of the following measures:

   • Reorient or relocate the receiving antenna.

   • Increase the separation between the equipment and receiver.

   • Connect the equipment into an outlet on a circuit different from that to which the receiver disconnected.

   • Consult the dealer or an experienced Radio/TV technician for help.
                                                         Modifications to the IMU not
                                                  expressly approved by Silver Spring Networks
                                                   may void your authority to operate the IMU.


© 2010 Silver Spring Networks | Company Confidential                                                               4


                                                       Components and Tools
   • Components:
                                           Component             Qty.   Part Number

                                           SSN IMU (top level,   1      224-040001
                                           includes hardware)




         –     See next page for hardware component detail

   • Tools:
         –     Flathead screw driver (capable of torque setting)
         –     Phillips screw driver (capable of torque setting)
         –     Pliers
         –     Nut driver
         –     Service magnet




                                                                        Service magnet

© 2010 Silver Spring Networks | Company Confidential                                     5


                                                       Components




               Screws 10-24 x 1/2                       Tamper Seals      Mounting Plate




               Flanged nut 10-24                         Pipe clamp    Cover screws, 6-32 x 1”




© 2010 Silver Spring Networks | Company Confidential                                             6


        Assembly Drawing (Single Channel Rotary and Turbine Meter IMU)




© 2010 Silver Spring Networks | Company Confidential                     7


        Assembly Drawing (Single Channel Rotary and Turbine Meter IMU)




© 2010 Silver Spring Networks | Company Confidential                     8


                                                   Inspect the Pulser Cable
   • Inspect the end of the pulser
     cable that will connect to the
     IMU.
         – There should be three wires
           exiting the outside insulation.
         – The red and black wires are
           insulated.
         – The 3rd wire is bare coming out
           of outside insulation, with a
           white sleeve on the end.

   • If needed, trim the pulser wires
     so the conductor is flush with
     the insulation and sleeve.

   Insert photo

   Pulser installation onto the gas meter is not
      covered here. Refer to the pulser
      manufacturer’s installation instructions.
© 2010 Silver Spring Networks | Company Confidential                          9


                                                       Inspect the IMU

   • Verify that the IMU has 3 wires

   • Verify that the enclosure is not                        • Verify that the
     cracked and that the MAC Address                          battery
     label is present                                          connectors are
                                                               undamaged.




                                                             • Verify




         If the IMU is damaged, return it to your supervisor and get a replacement.

© 2010 Silver Spring Networks | Company Confidential                                  10


                                         Connect the Pulser to the IMU


   •Thread the pulser cable through
   the cable seal connector.

   •Thread the pulser cable through
   the tie wrap.

   •Connect the 3 cables with the gel
   splices.
         – Do not strip the insulation from
           the wires.
         – Insert the wire pair (red and red,
           black and black, white and
           white) to be connected into a gel
           splice; push all the way forward.
         – Close the gel splice by squeezing
           the gel splice with pliers.
         – Repeat for the 3 pairs of wires
© 2010 Silver Spring Networks | Company Confidential                     11


                                         Connect the Pulser to the IMU
   • Make sure the 3 gel splices are to
     the right of the cable tie.

   • Tighten the cable tie. This
     provides extra strain relief for the
     cable.

   • Trim the cable tie.

   • Leave 1” of cable slack inside the
     IMU, and pull the rest of the
     cable out of the cable seal
     connector.

   • Tighten the cable seal connector.




© 2010 Silver Spring Networks | Company Confidential                     12


                               Connect the Battery Cable Connector


   •Connect the battery cable to the
   IMU cable. The connectors are
   keyed; you will not need to force
   them together.



   •Put the battery inside the battery
   compartment as shown.
         – The connector fits underneath
           the battery.
         – The flat part of the battery
           should be next to the inside wall.




© 2010 Silver Spring Networks | Company Confidential                 13


                                         Program the IMU for Field Use
   • Slowly pass the service magnet
     once (for 2 to 5 seconds) over the
     top of the IMU.

   • Watch for the light-emitting diode
     (LED) to flash on the lower left
     corner of the IMU circuit board
         – If you don’t see the LED flash,
           make sure the battery cable
           connections are made.
         – If you still don’t see the LED flash
           after checking that all the battery
           connections are made and re-
           swiping the magnet, return the IMU
           to your supervisor. Insert photo

   • Configure the IMU with the
     programming tool. (Field
       Configuration is a separate document).


© 2010 Silver Spring Networks | Company Confidential                     14


                         Inspect the Gasket and Fasten the Cover
      •     Re-inspect the gasket to
            ensure it seals the area
            between the enclosure and
            cover. Insert photo

      •     Fasten the cover to the
            enclosure with the 4 cover
            screws.
             –      The Silver Spring logo faces
                    up
             –      Torque the cover screws to
                    xxx

      •     Use a nut driver to push two
            tamper seals into the
            openings on the IMU cover.




© 2010 Silver Spring Networks | Company Confidential               15


              Attach the IMU Enclosure to the Mounting Plate

       • Determine where you want to
         install the IMU. This will
         determine if the plate should
         attach to the pipe horizontally or
         vertically.

       The photos here show a vertical attachment.


       • Attach the IMU enclosure to the
         mounting plate with the 2 screws
         and 2 flanged nuts.

                • Torque the screws to…




© 2010 Silver Spring Networks | Company Confidential           16


                Attach the IMU and Mounting Plate to the Pipe
   • Guide the metal clamp through
     the slot in the mounting plate.



   • Wrap the metal clamp around
     the pipe.



   • Tighten the metal clamp around
     the pipe by torquing the screw to
     12-20 in lb.




© 2010 Silver Spring Networks | Company Confidential            17



Document Created: 2011-04-25 07:35:56
Document Modified: 2011-04-25 07:35:56

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC