Operations User Manual

FCC ID: OWS-963

Users Manual

Download: PDF
FCCID_373269

Applicant: Silver Spring Networks, Inc. Gas Pulse Interface   FCC ID:OWS-963




Commercial & Industrial Gas Meter IMU Interface
Operational/Installation and Specification Manual


Silver Spring Networks AxisPathTM Network


Applicant: Silver Spring Networks, Inc. Gas Pulse Interface                                                FCC ID:OWS-963

Copyright  2003 Silver Spring Networks, Inc.
13000 West Silver Spring Drive
Butler, Wisconsin 53007
Phone: 262-783-0200
Fax: 262-783-0205
Internet: www.silverspringnetworks.com


                                         FCC WARNING STATEMENT

Note: This equipment has been tested and found to comply with the limits for Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential/office installation. The equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures.

    •   Reorient or relocate the receiving antenna
    •   Increase the separation between the equipment and receiver
    •   Connect the equipment into an outlet on a circuit different from that to which the receiver is
        connected
    •   Consult the dealer or an experienced Radio/TV technician for help


                                                      CAUTION

                     Changes or modifications not expressly approved by Silver Spring Networks, Inc.
                                could void the user’s authority to operate the equipment.

                                  The antenna on this device is professionally installed.


Note

The device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

        1.   The device may not cause harmful interferences.

        2.   The device must accept any interference received, including interference that may cause undesired operation.



Confidentiality Statement: The information, graphics, and materials in this document are confidential and proprietary.
Document Revision Number: 1.0.2


Applicant: Silver Spring Networks, Inc. Gas Pulse Interface                           FCC ID:OWS-963


Contents______________________________________________




                Preface……………………………………………………………………………………………………. iv
                   Organization of Manual………………………………………………………………………………… iv
                   Documentation Conventions…………………………………………………………………………… iv

PART I                   C&I Gas Interface Theory and Installation                .
                  Chapter 1 Theory of Operation……………………………………………………………………                        1-1
                     C&I Gas Interface Purpose……………………………………………………………………….                       1-1
                     Functionality………………………………………………………………………………………                              1-1
                     Components……………………………………………………………………………………….                                1-1

                  Chapter 2    Specifications…………………………………………………………………………… 2-1

                  Chapter 3 Installation and Initialization………………………………………………………….. 3-1
                      Introduction………………………………………………………………………………………. 3-1
                     Safety Information………………………………………………………………………………... 3-1
                      Installation Procedures……………………………………………………………………………. 3-2
                          Equipment Needs……………………………………………………………………………… 3-2
                         Download Work Orders from the Utility Network……………………………………………. 3-2
                         Before Installation……………………………………………………………………………… 3-3
                         C&I Gas Interface End-Point Device Installation……………………………………………... 3-4
                         Complete and Close the Task………………………………………………………………….. 3-9
                         After Installation……………………………………………………………………………… 3-10

                  Chapter 4    Troubleshooting………………………………………………………………………… 4-1


Applicant: Silver Spring Networks, Inc. Gas Pulse Interface                                             FCC ID:OWS-963


Preface_______________________________________________



Organization of Manual
        This manual is divided in the following manner:
        • “C&I Gas Meter Interface Theory and Installation”, provides information specific to the IMU end-point device.
        • “Theory of Operation”, containing a basic overview of the Silver Spring Networks AxisPathTM network and
            how the C&I Gas Meter Interface end-point device functions within the network.
        • “Installation and Initialization”, containing step-by-step IMU end-point device installation and initialization
            instructions.
        • “Troubleshooting”, containing IMU-specific system troubleshooting information.



Document Conventions

        This document uses a number of conventions designed to help communicate specific information. These
        conventions include the following:

        •   Danger, Warning, and Caution:

                                                           DANGER!
                         Danger messages alert you to situations that will cause
                         personal injury or death if you do not follow the instructions
                         correctly.

                                                          WARNING!
                         Warnings alert you to situations that may potentially cause
                         personal injury or death if you do not follow the directions
                         correctly.

                                                           CAUTION
                         Cautions alert you to situations that may result in damage to
                         the hardware or software if you do not follow the
                         instructions correctly.


Applicant: Silver Spring Networks, Inc. Gas Pulse Interface                                                  FCC ID:OWS-963



Chapter 1___________________________________________________
Theory of Operation


C&I Gas Meter Interface Purpose
        The C&I Gas Meter Interface is a programmable end-point device, designed to replace or supplement a customer’s
        existing mechanical utility meter index. Using a magnetic pulse output adapter to interface to the meter output, it
        can be installed on a variety of meter brands.

        The C&I Gas Meter Interface end-point device allows for accurate, near-real-time customer utility use information,
        which can be read from a remote location.


Functionality
        The C&I Gas Meter Interface end-point device performs two basic functions:

        •   Gathering and recording customer utility use information directly at the metering point.

        •   Sending and receiving messages to and from the utility company computer system such as:

                 -   Utility use, status, alarm data, and similar information.
                 -   Data requests, configuration, and verification messages.

        C&I Gas Meter Interface end-point devices communicate with the utility company computer system using a
        combination of Local Area Networks (LAN), AxisGateTM nodes, and a Wide Area Network (WAN).


Components
        C&I Gas Meter Interfaces are Silver Spring Networks end-point devices, containing two primary components: a
        digital processor and a radio transceiver.

        The digital processor within the end-point device gathers and records utility use data at the metering point. Every
        time the meter drive rotates, pulses are recorded by the digital processor. The pulses are converted into utility use
        data, and this data is stored until readings are requested from the utility.

        Each C&I Gas Meter Interface also contains a 900MHz two-way radio frequency (RF) transceiver. This radio
        provides communication between the end-point device, and an AxisGateTM node. Depending upon the
        communication distance involved, and Silver Spring Networks relay might be used between the end-point device
        and the node, to extend RF communications. This RF connection between the end-point device and the node,
        possibly through a relay, is a Local Area Network (LAN).

        AxisGateTM nodes then communicate with the rest of the AxisPathTM network using a Wide Area Network (WAN).
        This communication allows C&I Gas Meter Interfaces to transmit use data to the utility, or to receive requests or
        programming instructions from the utility, or from a technician or installer using a Field Service Unit attached to a
        laptop computer.

        See Silver Spring Networks publication 98-00004 (System Summary) for a more detailed explanation of
        communications on the Local Area Network (LAN) and Wide Area Network (WAN).


Applicant: Silver Spring Networks, Inc. Gas Pulse Interface                                    FCC ID:OWS-963


Chapter 2_____________________________________________
Technical Specifications


                                             C&I Gas Meter Interface Features
•   Full Two-way 900 MHz spread-spectrum communications between the IMU and the utility
•   Direct sequence spread-spectrum communication improves security
•   17 channels allow frequency coordination in dense applications with minimal interference
•   Software programmable configuration and control profiles
•   3.6-volt lithium-based long life battery pack
•   Unique serial number and assignable PIN
•   Autonomous tamper alarms
•   Professionally installed antenna
•   Virtual Shut-off capabilities
•   Run-away meter detection
•   First/Final Reading
•   Customer Selectable Billing Dates
•   Data and Intelligence Stored in the Meter




Item                           Specification
Physical dimensions            6.67”L X 4.76”W X 2.19”H
Weight                         2.7 lbs.
Power supply                   (3) 3.6 volt D-cell lithium-based battery pack
Output power                   20 dBm
Sensitivity                    >40 dBm SINAD
Channels                       17 (spaced at 1.5 MHz)
Frequency range                903 to 927 MHz
Modulation                     Direct Sequence Spread Spectrum
Base data rate                 62.5 KB / second
Compliance                     FCC Part 15, Class C
Interface                      RF LAN
Antenna type                   Internal
Enclosure                      Lexan NEMA 4X Enclosure
Temperature range              -40° to +85°C


Applicant: Silver Spring Networks, Inc. Gas Pulse Interface                                                FCC ID:OWS-963




Chapter 3_____________________________________________
Installation and Initialization


Introduction
        This section includes a set of detailed procedures for installation, configuration, and testing.

                                                        CAUTION
                          Read and study the following safety information before you
                          proceed with installation. In addition, cautions and warnings
                          appear within procedures and throughout the test, where
                          appropriate, to remind you of any related safety information.


Safety Information

        •   The antenna on this device is to be professionally installed. Contact the supplier or manufacturer for further
            instructions and see additional information below
        •   Observe the following safety guidelines. Careful planning of every job is essential. Nothing should be taken
            for granted. Do not take chances!
        •   Read and follow all approved policies and procedures provided by your employer associated with the
            procedures in this manual.
        •   Keep the work area clean and dry. Cluttered work areas cause accidents and injuries.
        •   Provide good lighting in the work area. You cannot work safely if you cannot see what you are doing.
        •   Report unsafe conditions or defective equipment to your immediate supervisor.
        •   Select the right tool for the job. Use tools properly. Keep tools in good working order.
        •   Handle materials carefully. Lift and carry properly.
        •   Keep unauthorized people out of the work area. Be especially cautious of children, who tend to be drawn to
            work activity.
        •   Silver Spring Networks Inc. assumes no liability for the customer’s failure to follow these safety guidelines.



Equipment Needs

        This section lists, and briefly describes, the various pieces of equipment required for C&I Gas Meter Interface end-
        point device installation, initialization, and testing processes.
        • Laptop computer-Runs the FSA software, which stores and retrieves work order information, and configures
            and tests installed C&I Gas Meter Interfaces.
        • Field Service Unit-900 MHz two-way radio frequency (RF) transceiver, allowing communication with an IMU
            for initialization.’


Applicant: Silver Spring Networks, Inc. Gas Pulse Interface                                             FCC ID:OWS-963




INSTRUCTIONS TO INSTALLERS AND USERS

Minimum Safe Distance from Antenna:                20cm (approximately 8inches)

Antenna Mounting

        •   The antenna as supplied by the manufacturer must not be mounted at a location such that any person or persons
            can come closer than the above-indicated minimum safe distance to the antenna

Antenna Substitution

        •   Do not substitute any antenna for the one supplied by the manufacturer. You may be exposing persons to
            harmful radiation. Contact supplier or manufacturer for further instructions.


Applicant: Silver Spring Networks, Inc. Gas Pulse Interface                                                  FCC ID:OWS-963


Before Installation

        Field Service Unit Set-Up
                The Field Service Unit is a 900 MHz two-way radio frequency (RF) transceiver, used for configuring and
                testing Silver Spring devices.

                 After arriving at the customer site, activate and test the Field Service Unit as follows:

                                             CAUTION
                                   DO NOT turn the Field Service Unit ON if
                                   the antenna is not installed. Damage to
                                   the Field Service Unit will result.

                 1.   Plug the Field Service Unit connection cord into the serial port of the laptop computer.

                 2.   Plug a 9 VDC / 500 mA power supply into the Field Service Unit power socket.

                                             CAUTION

                                   Using anything other than a 9 VDC /
                                   500 mA power source may damage the
                                   Field Service Unit.

                 3.   Turn on the Field Service Unit. An indicator light will shine if the
                      Field Service Unit power supply is functioning correctly.


Installation Procedure
        1.   Remove index register from C&I gas meter. For American, Rockwell and Sprague meters, remove the index
             register and replace with the Pulsimatic pulse output register or the RioTronics index register with pulse output.
             For a Roots meter interface, attach the appropriately modified register head with pulse output to the meter
             before installing the pulse output pickup device.
        2.   Attach the Silver Spring Networks C&I Gas Meter Interface (p/n 1620-05001) to a surrounding fixture to the
             gas meter. Fixturing locations can include the meter piping, meter fixturing brackets or surrounding structures.
        3.   Attach the cable assembly from the Pulsimatic or RioTronics pulse output generator to the Silver Spring
             Networks C&I Gas Meter Interface (p/n 1620-05001). The cable assembly attaches with a ‘push and twist’ lock
             for the weather-resistant seal.


Start the Field Service Application
         Note
         See Silver Spring Networks publication 98-00001 (Field Service Application User’s Guide) for a more detailed
         explanation of FSA operation.

        1.   Turn on the laptop computer.
        2.   Launch the FSA software. No error messages will display if the connection between the computer and the Field
             Service Unit is working.
        3.   Log in to the Field Service Application.


Applicant: Silver Spring Networks, Inc. Gas Pulse Interface                                                    FCC ID:OWS-963

Install the Pulse Output Interface Device
          For American/Sprague and Rockwell meters, interface with either the Pulsimatic pulse output adapter or the
          RioTronics adapter.
          • Install the Pulsimatic unit in line with the index register and upon installation of the unit, replace the index
              register on top of the Pulsimatic.
          • Install the RioTronics-enabled index register in place of the existing index register.

         For Dresser Industries’ Roots meters, please follow the instructions for installation of the RioTronics Interface
         module.

         Install the Silver Spring Networks C&I Gas Meter Interface radio device to the surrounding structure which can
         include the meter piping, meter fixtures/supports or some adjacent structure to the meter.

         Connect the meter pulse output device to the C&I Gas Meter Interface by using the weather-resistant cable assembly
         from the pulse output device.


Setup the Radio for Communication through the Gateway


Applicant: Silver Spring Networks, Inc. Gas Pulse Interface                        FCC ID:OWS-963


Chapter 4_____________________________________________
Troubleshooting


Table 3-1 Troubleshooting the C&I Gas Meter Interface
 Problem                               Possible Solution

 C&I Gas Meter Interface fails to          C&I GMI end-point device ID mis-match
 respond to the Field Service
 Application (FSA).                        RF channel mis-match

                                           Replace C&I GMI end-point device




Table 3-2 Troubleshooting the Laptop Computer/Field Service Unit
 Problem                                Possible Solution

 Laptop computer does not power up         Charge/replace battery
 Laptop computer does not start up         Contact System Administrator
 properly and/or the Field Service
 Application cannot be found.
 Field Service Unit does not power up      Check power source and power circuit
                                           connections.




Table 3-3 Troubleshooting the Field Service Application (FSA)
 Problem                                  Possible Solution

 Error message displays when Field         Check field service unit connection.
 Service Application (FSA) starts up.



Document Created: 2003-11-12 23:39:37
Document Modified: 2003-11-12 23:39:37

© 2024 FCC.report