Operational Instruction

FCC ID: OWS-925

Users Manual

Download: PDF
FCCID_124341

   C&I Electric
Unit Test Procedure

       Revision A

     August 22, 2000


         Table of Contents

         1.     Equipment Requirements
         2.     PCA Sub-Assembly Power Supply Function Test
         3.     PCA Sub-Assembly RF Communications Test
         4.     Final Assembly Test
         5.     Shipping Preparation




Document Type: Test Procedure                                 Page 2 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


1.      Equipment Requirements

                DVM (Digital voltmeter) with ohm and amp functions.
                (Bel MERIT, DX451)
                Dual Channel Oscilloscope, 100 MHz, 1GBs
                (Tektronix, TDS 220)
                Variable/Isolation AC Transformer (VIT), 0-150 Vac, 4 Amp
                (Global Specialties, 1504)
                PC with Windows 95 Operating System
                NCTT, Test software, Version 2.2.0 or later
                Field Service Unit with Version 2 Communications Chip (Siliconians) NCI installed
                Unit Under Test (UUT), in this case the C&I Electric Unit, Fab. Rev. 5.3 or higher, Firmware Ver. 23 or
                higher (CnI_V23.HEX, CS = 1c59)
                (Innovatec, Relay, Rev. 5.3 or later)

                Note: The information in parentheses is a suggested test equipment Manufacturer and Model.
                Equivalents may be substituted.




Document Type: Test Procedure                                                                                  Page 3 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


2.      PCA Sub-Assembly Power Supply and Battery Charger Function Test

        The following test in this section is to be performed before the PCA is installed into the Relay Housing.

        2.1.    Visual Inspection

                2.1.1    Verify that the following components are installed with proper orientation / polarity, per assembly
                         drawings: IC’s, Transistors, Diodes, Capacitors and Transformer.

                2.1.2    Check for solder bridges/solder splash across traces or other conductors.

                                                                                             Pass____Fail___


        2.2.    Continuity Tests

                2.2.1    Perform continuity test using DVM between metal tabs of U1, D2 and their heatsinks.
                         It should be open circuit or > 10 Meg Ohms for U1 and > 2 Meg Ohms for D2.

                                                                                           Pass____Fail___

                2.2.2    Perform continuity test between input AC line connectors (J3 to J4) and line to ground (J3-H to
                         J1-G and J4-N to J1-G). Should be open circuit or >2 Meg Ohms.

                                                                                           Pass____Fail___




Document Type: Test Procedure                                                                                       Page 4 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


        2.3.    Power Supply Test

                2.3.1.   Connect 220 V variac (with isolation transformer and built-in fuse) to the input connector of
                         power supply. Then, slowly bring up the voltage from 0 –85V while monitoring the line current.
                         The line current at 85V should be < 15 mA
                                                                                           Pass____Fail___

                2.3.2.   Wait few seconds and then verify all LEDs are turned on.
                                                                                         Pass____Fail___

                2.3.3. Measure the DC voltage between pins 3 and 21 of NCI connector (J7).
                Specification: 5.5 – 5.7V DC.
                                                                                    Pass____Fail___

                2.3.4. Measure DC voltage between pins 15 and 21 of NCI connector (J7).
                Specification: 5.0 to 5.1 Vdc
                                                                                    Pass____Fail___

                2.3.5. Measure DC voltage between pins 17 and 21 of NCI connector (J7).
                Specification: 3.5 to 3.7 Vdc
                                                                                    Pass____Fail___

                2.3.6.   Measure DC voltage between pins 2 and 5 of Molex connector (JP2).

                Specification: 12 to 14 Vdc
                                                                                         Pass____Fail___

                2.3.7.   Disconnect AC Power to UUT and install NCI unit onto the main board. Then, bring the voltage
                         slowly up to 85 Vac and repeat the above steps 4.2- 4.6.
                                                                                        Pass____Fail___

                2.3.8.   Bring up the AC line voltage slowly from 85 to 265 Vac and repeat the above steps with NCI
                         installed (full-load).
                                                                                         Pass____Fail___




Document Type: Test Procedure                                                                                 Page 5 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


        2.4.    Battery Charger Tests

                2.4.1.   Connect battery charger module to C&I main board connector (JP2) and verify that the voltage
                         across BAT + and BAT- on the charger board is set to 6.9 Vdc with 680 Ohm resistor connected
                         across battery leads. Otherwise, adjust R7 Pot to set battery voltage to 6.9Vdc.

                                                                                           Pass__Fail___

                2.4.2.    Connect battery leads to the battery terminals and verify that voltage across battery terminals
                          has reached to 6.9Vdc (fully charged).
                                                                                           Pass__Fail___

                2.4.3.    Disconnect AC power to C&I main board and verify that the LEDs stays on (good indication that
                          UUT is powered by battery only).
                                                                                       Pass__Fail___

                2.4.4.   Remove battery charger module from C&I board with battery leads disconnected from battery
                         terminals. Then connect a dc power supply to battery leads and slowly increase the voltage from
                         0-6.5 Vdc while monitoring battery status pin (JP1-4). Verify that battery status pin goes high at
                         5.25 Vdc
                                                                                           Pass__Fail___

                2.4.5.   Then, lower the dc Power supplies voltage slowly and verify that battery status pin (JP1-4) goes
                         low at 5.0Vdc.

                                                                                           Pass__Fail___




Document Type: Test Procedure                                                                                   Page 6 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


3. PCA Sub-Assembly RF Communications Test

        3.1.    System Hardware Set-up:

                3.1.1.   Firmware Installation:

                         Remove AC line voltage from PCA power leads.
                         Disconnect battery lead from Charger Assembly.
                         Verify installation of the EPROM with appropriate firmware reversion.


                3.1.2.   NCI Installation:

                         Install the NCI with version 2 communications IC (Siliconians) onto the PCA with appropriate
                         antenna, 900 MHz, and 50 Ohms impedance.

                3.1.3.   Electric Meter RS-232 Communication connection:

                         Install the Electric Meter to connector J7 as follow:
                         J7, Pin 12        =       Transmit         (Pin 2 of the DB9 Meter communications cable)
                         J7, Pin 11        =       Receive          (Pin 3 of the DB9 Meter communications cable)
                         J7, Pin 10        =       Ground           (Pin 5 of the DB9 Meter communications cable)

                         Power up the electric meter.

                3.1.4.   Power on test:

                         Apply 120V AC line voltage to the PCA power leads, observe for the Status Indicator LEDs, make
                         sure the Green and Yellow LEDs are illuminated.

                         Reconnect battery lead to Charger Assembly.


                                                                                                  Pass__Fail___




Document Type: Test Procedure                                                                                  Page 7 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


        3.2.    NCTT Setting:

                Using the PC, start the NCTT program.

                Connect the FSU (Field Service Unit) with version 2 communications IC (Siliconians) to the PC.

                Select “Setting” ! “Option”:

                Serial Port:             =      Select appropriate Serial Port
                Wakeup Interval          =      1.25    Sec
                Transmit Power           =      28 dBm
                Repeat Interval          =      3       Sec (Min.); Unchecked “Random”
                NCI Interaction          =      Checked “Automatic”
                Conversion Factor        =      0.00001




                FIGURE 1

                Select “O.K.”, then setting NCTT for C&I Electric Communications:




Document Type: Test Procedure                                                                                    Page 8 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


        3.3.    C&I Electric Communications and Functional Test

                3.3.1.   General device setup in NCTT:

                For “DEVICE”, select “Electric IMU” and “Device ID” select “7”
                For “TRANSMIT”, select “CHANNEL”= 0 (Default for untested Relay PCA)

                The following Transmit options are “unchecked”:
                “Auto Repeat”
                “Scan”
                “Wakeup/IMU”

                (The untested Relay UUT Communication Channel defaults initially to Channel 0; if unable to establish a
                communications link between the FSU and the Relay UUT, try to scan all channels for the UUT. Select
                “Query Serial Numbers” message type, “Select Scan”, and press “Transmit”, then observe the reply
                message to identify the Relay communications channel setting.)




                FIGURE 2




Document Type: Test Procedure                                                                                Page 9 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


                3.3.1.   [Query Serial Number]

                Select Query Serial Numbers and select “Transmit!”
                Observer for the “Incoming Message”, make sure the FSU (Field Service Unit) are communicating with
                the UUT, and reporting the correct serial number for attached Meter (Either Landis & Gyr, Vectron or
                applicable Device)




                         FIGURE 3


        METER S/N REPORTED:                      ______________________

        C&I DEVICE S/N REPORTED:                 ______________________

                                                                                       Pass__Fail___




Document Type: Test Procedure                                                                              Page 10 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


                3.3.2.   [Set Serial Number]

                         Set “Electric USN”      =      Type in the C&I Serial Number then press “Transmit”
                         Make sure to obtain a “Acknowledgement Message “ reply from Incoming Data

                                                                                       Pass__Fail___




                         FIGURE 4




Document Type: Test Procedure                                                                             Page 11 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


                3.3.3.   [Set Communication Parameters]

                         RF CHANNEL            =       INITIAL CHANNEL
                         LCD UPDATE RATE       =       1
                         BLINK RATE            =       1

                         Press “TRANMIT”
                         Make sure to obtain a “Acknowledgement Message “ reply from Incoming Data

                                                                                     Pass__Fail___




                         FIGURE 5




Document Type: Test Procedure                                                                        Page 12 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


                3.3.4.   [Query Status]

                         Select “Query Status for Message Type” then press “Transmit”
                         Make sure to obtain a reply from Incoming Data

                                                                                        Pass__Fail___




                         FIGURE 6




Document Type: Test Procedure                                                                           Page 13 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


4. Final Assembly Test

      The following test is to be performed after the PCA Assembly has been tested and install into appropriate Relay
      housing unit.

        4.1.    General Test

                Repeat step 3.3.2. and step 3.3.3., if necessary.

                4.1.1.   [Set Clock]

                         Select “Set Clock” message, enter the applicable data then press “Transmit”
                         Observe “Acknowledged Message “ reply in Incoming Data (See Figure 7)

                                                                                          Pass__Fail__




                         FIGURE 7




Document Type: Test Procedure                                                                                Page 14 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


                4.1.2.   [Query Clock]

                         Select “Query Clock” message, enter the appropriate Relay Serial Number,
                         and press “Transmit”
                         Observe “Acknowledged Message” reply in the Incoming Data fields (See Figure 8)
                         Verify Calendar and Clock settings.

                                                                                       Pass__Fail__




                         FIGURE 8




Document Type: Test Procedure                                                                              Page 15 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


        4.2.    Alarms Test:

                4.2.1.   [Set Alarm Option]

                         Electric USN              =   UUT Serial Number
                         Set Alarm Active Mask     =   FFFFFFFF (8)
                         Set Alarm Priority Mask   =   FFFFFFFF (8)
                         Alarm Timer               =   1       (Optional)
                         Alarm Channel             =   INITIAL CHANNEL (Same as Communications Channel)

                                                                                   Pass__Fail___




                         FIGURE 9




Document Type: Test Procedure                                                                       Page 16 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


                4.2.2.   Tamper Alarm Function Test:

                         Open the C&I UUT cover (Will release the Tamper Switch)
                         Verify the Tamper Alarm message is sent

                                                                                   Pass__Fail___




                         FIGURE 10




Document Type: Test Procedure                                                                      Page 17 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


                4.2.3.   Power Failure Alarm Function Test:

                         Disconnect the ac power to the C&I UUT; verify the Power Failure Alarm Message is sent

                                                                                        Pass__Fail___




                         FIGURE 11




Document Type: Test Procedure                                                                              Page 18 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


                4.2.4.   Power Restore Alarm Function Test

                         Re-connect the ac power to the C&I UUT; verify the Power Failure Restore Status Report

                                                                                        Pass__Fail___




                         FIGURE 12




Document Type: Test Procedure                                                                              Page 19 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


                4.2.5.   Disabling Alarm Transmit Function Test

                         Repeat step 4.2.1 and set “Alarm Active Mask” and “Alarm priority Mask” to 0:

                         Electric USN              =     UUT Serial Number
                         Set Alarm Active Mask     =     00000000 (8)
                         Set Alarm Priority Mask   =     00000000 (8)
                         Alarm Timer               =     1       (Optional)
                         Alarm Channel             =     INITIAL CHANNEL (Same as Communications Channel)

                         4.2.5.1. Activate “Tamper” switch; observe for none alarm send message transmits.

                         4.2.5.2. Disconnect AC power; observe for none alarm send message transmits.

                         4.2.5.3. Reconnect AC powers; observe for none alarm send message transmits.

                                                                                         Pass__Fail___




                         FIGURE 13




Document Type: Test Procedure                                                                                Page 20 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


        4.3.    Actuators Test:

                4.3.5.   [Set Actuator 1 Output]

                         Type in Electric USN      =    C&I UUT Serial Number
                         Set Actuator 1            =    ON
                         Set Actuator 2            =    OFF

                         Press “Transmit”
                         Make sure to obtain a “Acknowledgement Message “ reply from Incoming Data

                         Use DVM to verify between Pin 1, J10 (Actuator 1 Output) and Pin 3, J10 (Actuator 1) Common
                         are “Closed”
                         Use DVM to verify between Pin 2, J10 (Actuator 2 Output) and Pin 4, J10 (Actuator 2) Common
                         are “Open”

                                                                                       Pass__Fail___




                         FIGURE 13




Document Type: Test Procedure                                                                             Page 21 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


                4.3.6.   [Set Actuator 2 Output]

                         Type in Electric USN      =    C&I UUT Serial Number
                         Set Actuator 1            =    OFF
                         Set Actuator 2            =    ON

                         Press “Transmit”
                         Make sure to obtain a “Acknowledgement Message “ reply from Incoming Data

                         Use DVM to verify between Pin 1, J10 (Actuator 1 Output) and Pin 3, J10 (Actuator 1) Common
                         are “Open”
                         Use DVM to verify between Pin 2, J10 (Actuator 2 Output) and Pin 4, J10 (Actuator 2) Common
                         are “Close”

                                                                                       Pass__Fail___




                         FIGURE 14




Document Type: Test Procedure                                                                             Page 22 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


        4.4.    Battery Power Sustain Test:

                4.4.5.   Disconnect the ac power to the C&I UUT
                4.4.6.   [Query Serial Number]
                         Verify to obtain the correct Serial Number report for the C&I UUT.

                                                                                          Pass__Fail___




                         FIGURE 15




Document Type: Test Procedure                                                                             Page 23 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.


5.     Shipping Preparation:

                         •   IMPORTANT!:

                                 Make sure to disconnect the hook-up wire from the Battery charger to the
                                 Positive (+) terminal of the battery!

                                                         Battery Disconnect Check:         Initial_____


                         •   Mechanical Inspection:
                             Inspect all harware, screw and nut, wires and cables for propper fitting.

                         •   Cosmetic Inspection:
                             Inspect for cosmetic defective.




Document Type: Test Procedure                                                                             Page 24 of 24
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.