Test Report PCB

FCC ID: OWDTR-0160-E

Test Report

Download: PDF
FCCID_4023219

                   Engineering Solutions & Electromagnetic Compatibility Services


                                          FCC Certification Report

                                            Harris Corporation
                                       221 Jefferson Ridge Parkway
                                           Lynchburg, VA 24501

                                             Model: XL-185M
                                          Multiband Mobile Radio
                                         Model #/HVIN: XT-MPS1M

                                          FCC ID: OWDTR-0160-E


                                             September 27, 2018

Standards Referenced for this Report
Part 2: 2017       Frequency Allocations and Radio Treaty Matters; General Rules and Regulations
Part 24: 2017      Personal Communications Services
ANSI/TIA-603-D     Land Mobile FM50 or PM Communications Equipment – Measurement and
2010               Performance Standards


                                    Report Prepared By: Daniel Baltzell

                                     Document Number: 2018025PCB


This report may not be reproduced, except in full, without the full written approval of Rhein Tech Laboratories,
                   Inc. and Harris Corporation. Test results relate only to the item tested.

       These tests are accredited and meet the requirements of ISO/IEC 17025 as verified by ANAB.
                          Refer to certificate and scope of accreditation AT-1445.




                             360 Herndon Pkwy | Suite 1400 | Herndon | Virginia 20170
                           Phone: 703.689.0368 | Fax: 703.689.2056 | www.rheintech.com


Rhein Tech Laboratories, Inc.                                               Client: Harris Corporation
360 Herndon Parkway                                                        Model #/HVIN: XT-MPS1M
Suite 1400                                                                      ID’s: OWDTR-0160-E
Herndon, VA20170                                                            Standards: FCC Part 24
http://www.rheintech.com                                                     Report #: 2018025PCB

 FCC Equipment Class: PCB
                                        Rated
        FCC              Frequency                Frequency
                                      Conducted                Emission           Transmit
        Rule               Range                  Tolerance
                                       Output                 Designator           Mode
        Part               (MHz)                    (ppm)
                                      Power (W)
        24D               901 – 902      7.0         0.1       16K0F3E           Analog FM
        24D               940 – 941      7.0         0.1       16K0F3E          (Wideband)
        24D               901 – 902      7.0         0.1      16K0F1D/E      2-level FSK 9600
                                                                             Data/Digital Voice
        24D               940 – 941      7.0         0.1      16K0F1D/E
                                                                                (Wideband)

        24D               901 – 902      7.0         0.1       11K0F3E           Analog FM
        24D               940 – 941      7.0         0.1       11K0F3E         (Narrowband)
        24D               901 – 902      7.0         0.1      11K7F1D/E      2-level FSK 9600
                                                                             Data/Digital Voice
        24D               940 – 941      7.0         0.1      11K7F1D/E
                                                                               (Narrowband)

        24D               901 – 902      7.0         0.1      7K10F1D/E      2-level FSK 4800
                                                                             Data/Digital Voice
        24D               940 – 941      7.0         0.1      7K10F1D/E
                                                                              (XNarrowband)

       24D            901 – 902          7.0         0.1      8K40F1D/E
                                                                             C4FM Data/Voice
       24D            940 – 941          7.0         0.1      8K40F1D/E
       24D            901 – 902          7.0         0.1      8K10DXW          H-CPM (TDMA)
       24D            940 – 941          7.0         0.1      8K10DXW            Data/Voice
 * power is maximum ERP




                                                                               Page 2 of 34


Rhein Tech Laboratories, Inc.                                                                                            Client: Harris Corporation
360 Herndon Parkway                                                                                                     Model #/HVIN: XT-MPS1M
Suite 1400                                                                                                       ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                                                          Standard: FCC Part 24
http://www.rheintech.com                                                                                                  Report #: 2018025PCB

                                                                Table of Contents


  1   Test Result Summary ............................................................................................................................. 5
  2   General Information ................................................................................................................................ 5
    2.1 Test Facility....................................................................................................................................... 5
    2.2 Related Submittal(s)/Grant(s) ............................................................................................................ 5
    2.3 Grant Notes ...................................................................................................................................... 5
    2.4 Tested System Details ...................................................................................................................... 6
    2.5 Configuration of Tested System ........................................................................................................ 7
  3 FCC Part 2.1033(C)(8): Voltages and Currents through the Final Amplifying Stage ................................. 8
  4 FCC Part 2.1046(a): RF power output: Conducted; Part 24.132(b): Power and antenna height limits;...... 8
    4.1 Test Procedure ................................................................................................................................. 8
    4.2 Test Data .......................................................................................................................................... 8
  5 FCC Part 2.1051: Spurious Emissions at Antenna Terminals .................................................................. 9
    5.1 Test Procedure ................................................................................................................................. 9
    5.2 Test Data .......................................................................................................................................... 9
  6 FCC Part 2.1053(a): Field Strength of Spurious Emissions ................................................................... 10
    6.1 Test Procedure ............................................................................................................................... 10
    6.2 Test Data ........................................................................................................................................ 10
  7 FCC Part 2.1049(c)(1): Occupied Bandwidth; Part 24.131, Part 24.133(a)(1),(2): Authorized Bandwidth;13
    7.1 Test Procedure ............................................................................................................................... 13
    7.2 Test Data ........................................................................................................................................ 14
  8 FCC Part 2.1055: Frequency Stability; Part 24.135: Frequency Stability................................................ 29
    8.1 Test Procedure ............................................................................................................................... 29
    8.2 Test Data ........................................................................................................................................ 29
      8.2.1   Frequency Stability/Voltage Variation ...................................................................................... 30
  9 FCC Part 2.202: Necessary Bandwidth and Emission Bandwidth ......................................................... 31
  10 Conclusion ........................................................................................................................................... 32




                                                                                                                                    Page 3 of 34


Rhein Tech Laboratories, Inc.                                                                                      Client: Harris Corporation
360 Herndon Parkway                                                                                               Model #/HVIN: XT-MPS1M
Suite 1400                                                                                                 ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                                                    Standard: FCC Part 24
http://www.rheintech.com                                                                                            Report #: 2018025PCB

                                                            Table of Figures

Figure 2-1:          Configuration of Tested System .......................................................................................... 7


                                                             Table of Tables

Table 2-1:           Equipment Under Test (EUT) .............................................................................................. 6
Table 2-2:           Auxiliary Equipment ............................................................................................................ 6
Table 4-1:           RF Conducted Output Power – Measured ........................................................................... 8
Table 4-2:           Test Equipment Used For Testing RF Power Output - Conducted ....................................... 8
Table 5-1:           Test Equipment Used For Testing Spurious Emissions........................................................ 9
Table 6-1:           Field Strength of Spurious Radiation – 901.9750 MHz....................................................... 10
Table 6-2:           Field Strength of Spurious Radiation – 940.9750 MHz....................................................... 11
Table 6-3:           Test Equipment Used For Testing Field Strength of Spurious Radiation ............................ 11
Table 7-1:           Test Equipment Used For Testing Occupied Bandwidth .................................................... 28
Table 8-1:           Temperature Frequency Stability – 937.5 MHz .................................................................. 29
Table 8-2:           Test Equipment Used For Testing Temperature Frequency Stability .................................. 30
Table 8-3:           Frequency Stability/Voltage Variation – 937.5 MHz ........................................................... 30
Table 8-4:           Test Equipment Used For Testing Frequency Stability/Voltage Variation ........................... 30


                                                                Table of Plots

Plot 7-1:            Occupied Bandwidth – 901.9750 MHz; NB Analog; Mask 24.133(2) .................................. 14
Plot 7-2:            Occupied Bandwidth – 901.9750 MHz; WB Analog; Mask 24.133(1) ................................. 15
Plot 7-3:            Occupied Bandwidth – 901.9750 MHz; 2-Level FSK 9600 WB; Mask 24.133(1) ................ 16
Plot 7-4:            Occupied Bandwidth – 901.9750 MHz; 2-Level FSK 9600 NB; Mask 24.133(2) ................. 17
Plot 7-5:            Occupied Bandwidth – 901.9750 MHz; 2-Level FSK 4800 XNB; Mask 24.133(2) ............... 18
Plot 7-6:            Occupied Bandwidth – 901.9750 MHz; P25; Mask 24.133(2)............................................. 19
Plot 7-7:            Occupied Bandwidth – 901.9750 MHz; H-CPM (TDMA); Mask 24.133(2) .......................... 20
Plot 7-8:            Occupied Bandwidth – 940.9750 MHz; NB Analog; Mask 24.133(2) .................................. 21
Plot 7-9:            Occupied Bandwidth – 940.9750 MHz; WB Analog; Mask 24.133(1) ................................. 22
Plot 7-10:           Occupied Bandwidth – 940.9750 MHz; 2-Level FSK 9600 WB; Mask 24.133(1) ................ 23
Plot 7-11:           Occupied Bandwidth – 940.9750 MHz; 2-Level FSK 9600 NB; Mask 24.133(2) ................. 24
Plot 7-12:           Occupied Bandwidth – 940.9750 MHz; 2-Level FSK 4800 XNB; Mask 24.133(2) ............... 25
Plot 7-13:           Occupied Bandwidth – 940.9750 MHz; P25; Mask 24.133(2)............................................. 26
Plot 7-14:           Occupied Bandwidth – 940.9750 MHz; H-CPM (TDMA); Mask 24.133(2) .......................... 27


                                                           Table of Appendixes

Appendix A:          Test Configuration Photographs ........................................................................................ 33


                                                           Table of Photographs

Photograph 1:        Radiated Emissions (Spurious/Harmonics) – Front View ................................................... 33
Photograph 2:        Radiated Emissions (Spurious/Harmonics) – Back View.................................................... 34




                                                                                                                             Page 4 of 34


Rhein Tech Laboratories, Inc.                                                            Client: Harris Corporation
360 Herndon Parkway                                                                     Model #/HVIN: XT-MPS1M
Suite 1400                                                                       ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                          Standard: FCC Part 24
http://www.rheintech.com                                                                  Report #: 2018025PCB

  1     Test Result Summary

                        Test                                       FCC Reference                       Result
  RF Power Output                                    2.1046(a), 24.132(b)                             Complies
  Spurious Emissions at Antenna Terminals            2.1051                                           Complies
  Field Strength of Spurious Radiation               2.1053(a)                                        Complies
  Occupied Bandwidth/Emission Masks                  2.1049(c)(1), 24.131, 24.133(a)(1),(2)           Complies
  Frequency Stability vs. Temperature and
                                                     2.1055, 24.135                                   Complies
  Voltage


  2     General Information

  The following Certification Report is prepared on behalf of Harris Corporation in accordance with the Federal
  Communications Commission and ISED rules and regulations. The Equipment Under Test (EUT) was the
  XL-185M, Model #/HVIN XT-MPS1M; FCC ID: OWDTR-0160-E.

  All measurements contained in this application were conducted in accordance with the applicable sections of
  FCC Rules and Regulations CFR 47 Parts 2 and 24. Calibration checks are performed regularly on the
  instruments, and all accessories including high pass filter, coaxial attenuator, preamplifier and cables.

  2.1    Test Facility

  The open area test site and conducted measurement facility used to collect the radiated data is located on the
  parking lot of Rhein Tech Laboratories, Inc. 360 Herndon Parkway, Suite 1400, Herndon, Virginia 20170.
  This site has been fully described in a report submitted to, and approved by, the Federal Communications
  Commission to perform AC line conducted and radiated emissions testing.

  2.2    Related Submittal(s)/Grant(s)

  This is an original certification application for Harris Corporation Model XL-185M, Model #/HVIN XT-MPS1M,
  FCC ID: OWDTR-0160-E.

  2.3    Grant Notes

  RF power switchable from 2 W to rated power 7 W ERP.




                                                                                               Page 5 of 34


Rhein Tech Laboratories, Inc.                                                              Client: Harris Corporation
360 Herndon Parkway                                                                       Model #/HVIN: XT-MPS1M
Suite 1400                                                                         ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                            Standard: FCC Part 24
http://www.rheintech.com                                                                    Report #: 2018025PCB

  2.4     Tested System Details

  The test sample was received on August 24, 2018. Listed below are the identifiers and descriptions of all
  equipment, cables, and internal devices used with the EUT for this test, as applicable.

  The device was programmed for multiple modes of operation and modulation types.

  Table 2-1:        Equipment Under Test (EUT)
                                                                                                              RTL
         Part            Manufacturer          Model/HVIN              PN/SN                FCC ID             Bar
                                                                                                              Code
     Vehicular
                                                 XL-185M/           14050-1100-
  Communication       Harris Corporation                                                OWDTR-0160-E         22754
                                                XT-MPS1M           11/EVM2 No.25
    Hub (VCH)
                                               XL-CH Mobile
   Control Head       Harris Corporation       Control Head/      14050-1150-01/005     OWDTR-0160-E         22755
                                                   N/A

  Table 2-2:        Auxiliary Equipment
                                                                                                             RTL
             Part               Manufacturer          Model                PN/SN               FCC ID         Bar
                                                                                                             Code
        USB Mobile Mic              N/A          USB Mobile Mic      14050-6010-01/V22e           N/A        22756
                                                     Remote
        Remote Speaker              N/A                                 14050-6100-01             N/A         N/A
                                                     Speaker
        Analog Deskmic              N/A          Analog Deskmic        MC-014121-003              N/A         N/A
           CH                                         CH
                                    N/A                                 14050-6210-01             N/A         N/A
      Mounting Kit                                 Mounting Kit
          VCH                                         VCH
                                    N/A                                 14050-6200-01             N/A         N/A
      Mounting Kit                                 Mounting Kit
  Antenna, Flex, Heavy-
                                    N/A             XM-AN7G             12099-0300-01             N/A         N/A
   Duty, 136-870 MHz
   Antenna, Element,
   Multiband, 136-870               N/A             XMAN6H              12099-0310-01             N/A         N/A
       MHz, 0 dB
     Antenna, Base,
  Standard Roof Mount               N/A          AN-125001-002         AN-125001-002              N/A         N/A
        Low Loss
  Antenna, Base, Thick
                                    N/A          AN-125001-004         AN-125001-004              N/A         N/A
  Roof Mount Low Loss
     Antenna, Base,
  Standard Roof Mount               N/A          AN-125001-006         AN-125001-006              N/A         N/A
     Low Loss GPS
     Antenna, Base,
  Magnetic Mount Low                N/A          AN-125001-008         AN-125001-008              N/A         N/A
          Loss
  Mount, NMO Antenna,
                                    N/A             XM-AN7H             12099-0370-01             N/A         N/A
  Magnetic, Heavy-Duty
   Antenna, Element,
                                    N/A          AN-225001-001         AN-225001-001              N/A         N/A
      700/800 3db
   Antenna, Element,
                                    N/A          AN-225005-001         AN-225005-001              N/A         N/A
        900, 3db
                                                                                                 Page 6 of 34


Rhein Tech Laboratories, Inc.                                                  Client: Harris Corporation
360 Herndon Parkway                                                           Model #/HVIN: XT-MPS1M
Suite 1400                                                             ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                Standard: FCC Part 24
http://www.rheintech.com                                                        Report #: 2018025PCB

         Antenna, GPS,
                                    N/A      AN-025187-001   AN-025187-001            N/A         N/A
          Roof Mount
         Antenna, GPS,
                                    N/A      AN-025187-003   AN-025187-003            N/A         N/A
         Magnet Mount
         Antenna Base,
        Stnd Roof Mount             N/A      AN-125001-006   AN-125001-006            N/A         N/A
         Low Loss GPS
          Antenna 3dB
                                    N/A      12099-0380-01   12099-0380-01            N/A         N/A
          700/800/900
    Squid Cable (HD44)              N/A          N/A         14002-0174-50            N/A         N/A
        Ethernet Cable,
                                    N/A          N/A         14050-6300-01            N/A         N/A
        overmold, 45cm
        Ethernet Cable,
                                    N/A          N/A         14050-6300-02            N/A         N/A
         overmold, 9m
  DC power cables (CH)              N/A          N/A         CA-012616-001            N/A         N/A
        DC power cables
                                    N/A          N/A         CA-012365-001            N/A         N/A
            (VCH)

  2.5     Configuration of Tested System

                                                                Power Supply 13.6 VDC




         Microphone

                                                                 EUT
                                Control
                                Head

                                                    VCH




                To Laptop Serial / Control




  Figure 2-1:      Configuration of Tested System




                                                                                     Page 7 of 34


Rhein Tech Laboratories, Inc.                                                        Client: Harris Corporation
360 Herndon Parkway                                                                 Model #/HVIN: XT-MPS1M
Suite 1400                                                                   ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                      Standard: FCC Part 24
http://www.rheintech.com                                                              Report #: 2018025PCB

  3      FCC Part 2.1033(C)(8): Voltages and Currents through the Final Amplifying Stage

         13.6 VDC / 8.6 A


  4      FCC Part 2.1046(a): RF power output: Conducted; Part 24.132(b): Power and antenna height limits;

  4.1     Test Procedure

  ANSI C63.26, section 5.2

  The EUT was connected to a coaxial attenuator having a 50 Ω load impedance. Manufacturer’s rated power:
  7 W.

  4.2     Test Data

  Table 4-1:     RF Conducted Output Power – Measured
    Frequency (MHz)      High Power (dBm)     High Power (W)           Low Power (dBm)       Low Power (W)
        901.9750               38.5                 7.0                     33.2                  2.1
        940.9750               38.5                 7.0                     33.2                  2.1

  Notes: Data presented is for analog mode. All other modes were investigated and found to have equivalent
  power within measurement tolerances.

  Table 4-2:       Test Equipment Used For Testing RF Power Output - Conducted
                                                                                                Calibration
   RTL Asset #        Manufacturer       Model            Part Type        Serial Number
                                                                                                 Due Date
                        Rohde &
        901581                            FSU         Spectrum Analyzer     1166.1660.50          4/26/21
                        Schwarz
                      API Weinschel,                     40 dB 100W
        901724                         48-40-34                                CJ8921              8/7/19
                           Inc.                           Attenuator

  Measurement uncertainties shown for these tests are expanded uncertainties expressed at the 95%
  confidence level using a coverage factor K=2. Measurement uncertainty: ±0.5 dB

  Results: Pass

  Test Personnel:


            Daniel Baltzell                                                  September 26, 2018
          EMC Test Engineer                       Signature                     Date of Test




                                                                                           Page 8 of 34


Rhein Tech Laboratories, Inc.                                                           Client: Harris Corporation
360 Herndon Parkway                                                                    Model #/HVIN: XT-MPS1M
Suite 1400                                                                      ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                         Standard: FCC Part 24
http://www.rheintech.com                                                                 Report #: 2018025PCB

  5     FCC Part 2.1051: Spurious Emissions at Antenna Terminals

  5.1    Test Procedure

  ANSI C63.26, Section 5.7

  The transmitter is terminated with a 50 Ω load and interfaced with a spectrum analyzer.

  Device with digital modulation: Modulated to its maximum extent using a pseudo-random data sequence.

  5.2    Test Data

  Frequency range of measurement per Part 2.1057: 9 kHz to 10 x Fc

  Limits: (43+10LOG P(W)) for wideband and 50 + 10 LOG P(W)) for narrowband

  The following channels (in MHz) were investigated:

                                                    901.9750
                                                    940.9750

  Both high and low power settings were checked; high power was found to be worst case and is presented. All
  modes were investigated and no emissions were found within 20 dB below the limit, therefore no data is
  presented.

  Measurement uncertainties shown for these tests are expanded uncertainties expressed at the 95%
  confidence level using a coverage factor K=2. Measurement uncertainty: ±0.5 dB

  Results: Pass

  Table 5-1:       Test Equipment Used For Testing Spurious Emissions
    RTL                                                                              Serial         Calibration
                Manufacturer          Model                   Part Type
   Asset #                                                                          Number           Due Date
                  Rohde &
   901581                              FSU              Spectrum Analyzer        1166.1660.50         4/26/21
                  Schwarz
                API Weinschel,
   901724                            48-40-34          40 dB 100W Attenuator        CJ8921             8/7/19
                     Inc.
   901132       Par Electronics   806-902 (25W)          UHF Notch Filter             N/A             8/10/19

  Test Personnel:


           Daniel Baltzell                                                      September 27, 2018
         EMC Test Engineer                        Signature                        Date of Test




                                                                                              Page 9 of 34


Rhein Tech Laboratories, Inc.                                                           Client: Harris Corporation
360 Herndon Parkway                                                                    Model #/HVIN: XT-MPS1M
Suite 1400                                                                      ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                         Standard: FCC Part 24
http://www.rheintech.com                                                                 Report #: 2018025PCB

  6     FCC Part 2.1053(a): Field Strength of Spurious Emissions

  6.1     Test Procedure

  ANSI C63.26 section 5.5

  The device uses digital modulation modulated to its maximum extent using a pseudo-random data sequence.

  The spurious emissions levels were measured, and the device under test was replaced by a substitution
  antenna connected to a signal generator. This signal generator level was then corrected by subtracting the
  cable loss from the substitution antenna to the signal generator, and the gain of the antenna (dBi) was added
  to achieve the EIRP level, then converted from the corrected signal generator level (dBm) to dBc and
  compared to the limit.

  6.2     Test Data

  Table 6-1:       Field Strength of Spurious Radiation – 901.9750 MHz
                      Conducted Power 45.8 dBm; 38.0 W; Limit=50+10 Log P=65.8 dBc
                                                   Cable
                                                                            Corrected
                     Spectrum        Signal        Loss        Substitution
                                                                             Signal
      Frequency      Analyzer      Generator         to          Antenna                              Margin
                                                                            Generator
        (MHz)          Level           Level     Transmit          Gain                                (dB)
                                                                              Level
                      (dBuV)          (dBm)      Antenna           (dBi)
                                                                              (dBc)
                                                    (dB)
      1803.9500          2.1          -69.8           0.4              8.8             107.2            -41.4
      2705.9250          15.6         -62.2           0.6              0.0             108.6            -42.8
      3607.9000          8.1          -66.1           0.8              9.7             103.0            -37.2
      4509.8750          -2.6         -74.2           0.9             11.0             109.9            -44.1
      5411.8500          -0.7         -72.6           1.0             10.6             108.8            -43.0
      6313.8250          -5.7         -76.6           1.2             11.4             112.2            -46.4
      7215.8000          -1.3         -71.1           1.3             11.2             107.0            -41.2
      8117.7750          -4.2         -67.9           1.5             11.4             103.8            -38.0
      9019.7500          -7.5         -69.9           1.6             11.1             106.1            -40.3




                                                                                             Page 10 of 34


Rhein Tech Laboratories, Inc.                                                       Client: Harris Corporation
360 Herndon Parkway                                                                Model #/HVIN: XT-MPS1M
Suite 1400                                                                  ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                     Standard: FCC Part 24
http://www.rheintech.com                                                             Report #: 2018025PCB

  Table 6-2:       Field Strength of Spurious Radiation – 940.9750 MHz
                      Conducted Power 45.7 dBm; 37.2 W; Limit=50+10 Log P=65.7 dBc
                                                   Cable
                                                                            Corrected
                     Spectrum        Signal        Loss        Substitution
                                                                             Signal
   Frequency         Analyzer      Generator         to          Antenna                            Margin
                                                                            Generator
     (MHz)             Level           Level     Transmit          Gain                              (dB)
                                                                              Level
                      (dBuV)          (dBm)      Antenna           (dBi)
                                                                              (dBc)
                                                    (dB)
    1881.9500           2.8            -68.7         0.5             8.5      106.4                  -40.7
    2822.9250           7.5            -70.0         0.6            10.0      106.3                  -40.6
    3763.9000            21.7        -52.2          0.8            9.2             89.5              -23.8
    4704.8750            11.6        -59.9          0.9            11.1            95.4              -29.7
    5645.8500            5.0         -66.6          1.1            11.0            102.4             -36.7
    6586.8250            -5.2        -75.7          1.2            11.8            110.8             -45.1
    7527.8000            2.0         -67.2          1.4            11.1            103.2             -37.5
    8468.7750           -11.2        -72.2          1.5            11.5            107.9             -42.2
    9409.7500            -8.2        -71.6          1.7            11.5            107.4             -41.7

  Measurement uncertainties shown for these tests are expanded uncertainties expressed at the 95%
  confidence level using a coverage factor K=2. Measurement uncertainty: ±4.6 dB

  Results: Pass

  Table 6-3:       Test Equipment Used For Testing Field Strength of Spurious Radiation
    RTL                                                                          Serial         Calibration
                Manufacturer          Model                 Part Type
  Asset #                                                                      Number            Due Date
                  Rhein Tech                         3 meter antenna mast,
   900878                         AM3-1197-0005                                 OATS1                N/A
                 Laboratories                               polarizing
                Insulated Wire   KPS-1503-3150-
   901729                                             SMK RF Cables 20’           NA                8/21/19
                      Inc.             KPR
   901128       Par Electronics   806-902 (25W)         UHF Notch Filter          N/A               8/10/19
                Insulated Wire
   901727                       KPS-1503-360-KPR      SMK RF Cables 36”           NA                8/20/19
                      Inc.
                  Rhein Tech
   901242                         WRT-000-0003        Wood rotating table         N/A                N/A
                 Laboratories
                                                          Bilog antenna
   900791           Chase           CBL6111B                                      N/A               10/4/20
                                                     (30 MHz – 2000 MHz)
                                                          Horn Antenna
   900321           EMCO             3161-03                                  9508-1020             4/9/19
                                                         (4.0 - 8.2 GHz)
                                                          Horn Antenna
   900323           EMCO             3160-07                                  9605-1054             4/9/19
                                                        (8.2 - 12.4 GHz)
                                                          Horn Antenna
   900772           EMCO             3161-02                                  9804-1044             4/9/19
                                                           (2 - 4 GHz)
                   Rohde &
   901581                              FSU             Spectrum Analyzer     1166.1660.50           4/26/21
                   Schwarz
                   Rohde &
   901582                          1167.0000.02         Signal Generator        101903              4/24/21
                   Schwarz




                                                                                          Page 11 of 34


Rhein Tech Laboratories, Inc.                       Client: Harris Corporation
360 Herndon Parkway                                Model #/HVIN: XT-MPS1M
Suite 1400                                  ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                     Standard: FCC Part 24
http://www.rheintech.com                             Report #: 2018025PCB

  Test Personnel:


             Daniel Baltzell                September 13-17, 2018
             Test Engineer      Signature       Dates of Tests




                                                         Page 12 of 34


Rhein Tech Laboratories, Inc.                                                           Client: Harris Corporation
360 Herndon Parkway                                                                    Model #/HVIN: XT-MPS1M
Suite 1400                                                                      ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                         Standard: FCC Part 24
http://www.rheintech.com                                                                 Report #: 2018025PCB

  7     FCC Part 2.1049(c)(1): Occupied Bandwidth; Part 24.131, Part 24.133(a)(1),(2): Authorized Bandwidth;

  Occupied Bandwidth - Compliance with the Emission Masks

  7.1    Test Procedure

  ANSI C63.26-2015, section 5.4

  Device with digital modulation: Modulated to its maximum extent using a pseudo-random data sequence.

  Part 24.131 Authorized Bandwidth

  The authorized bandwidth of narrowband PCS channels will be 10 kHz for 12.5 kHz channels and 45 kHz
  for 50 kHz channels. For aggregated adjacent channels, a maximum authorized bandwidth of 5 kHz less than
  the total aggregated channel width is permitted.

  Part 24.133 Emission Limits

  (1) For transmitters authorized a bandwidth greater than 10 kHz:

  (i) On any frequency outside the authorized bandwidth and removed from the edge of the authorized
  bandwidth by a displacement frequency (fd in kHz) of up to and including 40 kHz: at least 116 Log10 ((fd +
  10)/6.1) decibels or 50 plus 10 Log10 (P) decibels or 70 decibels, whichever is the lesser attenuation;

  (ii) On any frequency outside the authorized bandwidth and removed from the edge of the authorized
  bandwidth by a displacement frequency (fd in kHz) of more than 40 kHz: at least 43 + 10 Log10 (P) decibels
  or 80 decibels, whichever is the lesser attenuation.

  (2) For transmitters authorized a bandwidth of 10 kHz:

  (i) On any frequency outside the authorized bandwidth and removed from the edge of the authorized
  bandwidth by a displacement frequency (fd in kHz) of up to and including 20 kHz: at least 116 × Log10 ((fd +
  5)/3.05) decibels or 50 + 10 × Log10 (P) decibels or 70 decibels, whichever is the lesser attenuation;

  (ii) On any frequency outside the authorized bandwidth and removed from the edge of the authorized
  bandwidth by a displacement frequency (fd in kHz) of more than 20 kHz: at least 43 + 10 Log 10 (P) decibels
  or 80 decibels, whichever is the lesser attenuation.

  (d) The following minimum spectrum analyzer resolution bandwidth settings will be used: 300 Hz when
  showing compliance with paragraphs (a)(1)(i) and (a)(2)(i) of this section; and 30 kHz when showing
  compliance with paragraphs (a)(1)(ii) and (a)(2)(ii) of this section.




                                                                                             Page 13 of 34


Rhein Tech Laboratories, Inc.                                                          Client: Harris Corporation
360 Herndon Parkway                                                                   Model #/HVIN: XT-MPS1M
Suite 1400                                                                     ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                        Standard: FCC Part 24
http://www.rheintech.com                                                                Report #: 2018025PCB

  7.2      Test Data

  Plot 7-1:           Occupied Bandwidth – 901.9750 MHz; NB Analog; Mask 24.133(2)
                                                                         Marker 1 [T1 ]
                                                                                   -56.83 dBm
           Ref    40 dBm                                                    902.025000000 MHz
                  Offset   39.5 dB
            30                            LIMIT CHECK    PASS
            20                                                                                  A

          10
   1 RM *
   MAXH   0
                                                                                                LVL
            -10
            -20
            -30
            -40
   SPECT
            -50                                                                             13DB

           Center 901.975 MHz                  10 kHz/                          Span 100 kHz

            Tx Channel                                                          None
            Bandwidth              10 kHz         Power                  38.48 dBm
              Start     Stop     RBW       Freq        PwrAbs   PwrRel   ∆ Limit
              [Hz]      [Hz]     [Hz]      [Hz]         [dBm]    [dBc]      [dB]
            -50.000 k -25.000 k 300.00   901.936500 M -44.97    -83.46   -31.97
            -25.000 k -14.740 k 300.00   901.960000 M -40.45    -78.93   -20.45
            -14.740 k  -5.000 k 300.00   901.967500 M    0.36   -38.12   -23.12
              5.000 k  14.740 k 300.00   901.980100 M   17.16   -21.33   -20.74
             14.740 k  25.000 k 300.00   901.990100 M -40.71    -79.19   -20.71
             25.000 k  50.000 k 300.00   902.013700 M -44.24    -82.72   -31.24




  Date: 27.SEP.2018         12:57:47




                                                                                            Page 14 of 34


Rhein Tech Laboratories, Inc.                                                                 Client: Harris Corporation
360 Herndon Parkway                                                                          Model #/HVIN: XT-MPS1M
Suite 1400                                                                            ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                               Standard: FCC Part 24
http://www.rheintech.com                                                                       Report #: 2018025PCB

  Plot 7-2:         Occupied Bandwidth – 901.9750 MHz; WB Analog; Mask 24.133(1)
                                                                                Marker 1 [T1 ]
                                                                                          -66.76 dBm
         Ref    50 dBm                                                             902.075000000 MHz
                Offset   39.5 dB
          40                                    LIMIT CHECK    PASS
          30                                                                                           A

          20
   1 SA *
   MAXH   10
                                                                                                       LVL
          0
          -10
          -20
         -30
   SPECT -40                                                                                        3DB
                                                                                                   1

         Center 901.975 MHz                          20 kHz/                           Span 200 kHz

          Tx Channel                                                                   None
          Bandwidth                       10 kHz         Power                  38.94 dBm
            Start          Stop         RBW       Freq        PwrAbs   PwrRel   ∆ Limit
            [Hz]           [Hz]         [Hz]      [Hz]         [dBm]    [dBc]      [dB]
         -100.000 k      -50.000   k   300.00   901.885600 M -46.83    -85.77   -33.83
          -50.000 k      -19.480   k   300.00   901.936400 M -44.93    -83.87   -24.93
          -19.480 k      -10.000   k   300.00   901.955800 M -49.20    -88.14   -30.93
           10.000 k       19.480   k   300.00   901.994000 M -47.72    -86.66   -30.68
           19.480 k       50.000   k   300.00   902.000600 M -43.17    -82.10   -23.17
           50.000 k      100.000   k   300.00   902.064400 M -44.19    -83.13   -31.19




  Date: 27.SEP.2018       14:36:32




                                                                                                   Page 15 of 34


Rhein Tech Laboratories, Inc.                                                                Client: Harris Corporation
360 Herndon Parkway                                                                         Model #/HVIN: XT-MPS1M
Suite 1400                                                                           ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                              Standard: FCC Part 24
http://www.rheintech.com                                                                      Report #: 2018025PCB

  Plot 7-3:         Occupied Bandwidth – 901.9750 MHz; 2-Level FSK 9600 WB; Mask 24.133(1)


         Ref    40 dBm
                Offset   39.5 dB
          30                                    LIMIT CHECK    PASS
          20                                                                                         A

          10
   1 SA *
   MAXH   0
                                                                                                     LVL
          -10
          -20
          -30
         -40
   SPECT -50                                                                                         3DB

         Center 901.975 MHz                          20 kHz/                          Span 200 kHz

          Tx Channel                                                                   None
          Bandwidth                       10 kHz         Power                  42.55 dBm
            Start          Stop         RBW       Freq        PwrAbs   PwrRel   ∆ Limit
            [Hz]           [Hz]         [Hz]      [Hz]         [dBm]    [dBc]      [dB]
         -100.000 k      -50.000   k   300.00   901.880200 M -48.59    -91.14   -35.59
          -50.000 k      -19.480   k   300.00   901.955400 M -26.84    -69.38    -6.84
          -19.480 k      -10.000   k   300.00   901.955600 M -26.03    -68.58    -6.03
           10.000 k       19.480   k   300.00   901.994200 M -25.12    -67.67    -6.85
           19.480 k       50.000   k   300.00   901.994480 M -23.98    -66.53    -3.98
           50.000 k      100.000   k   300.00   902.040400 M -46.15    -88.69   -33.15




  Date: 27.SEP.2018       13:27:01




                                                                                                  Page 16 of 34


Rhein Tech Laboratories, Inc.                                                         Client: Harris Corporation
360 Herndon Parkway                                                                  Model #/HVIN: XT-MPS1M
Suite 1400                                                                    ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                       Standard: FCC Part 24
http://www.rheintech.com                                                               Report #: 2018025PCB

  Plot 7-4:         Occupied Bandwidth – 901.9750 MHz; 2-Level FSK 9600 NB; Mask 24.133(2)
                                                                        Marker 1 [T1 ]
                                                                                  -51.46 dBm
         Ref    40 dBm                                                     902.025000000 MHz
                Offset   39.5 dB
          30                             LIMIT CHECK    PASS
          20                                                                                   A

          10
   1 SA *
   MAXH   0
                                                                                               LVL
          -10
          -20
          -30
         -40
   SPECT -50                                                                               1
                                                                                            3DB

         Center 901.975 MHz                   10 kHz/                          Span 100 kHz

          Tx Channel                                                           None
          Bandwidth              10 kHz         Power                   44.60 dBm
            Start     Stop     RBW       Freq        PwrAbs    PwrRel   ∆ Limit
            [Hz]      [Hz]     [Hz]      [Hz]         [dBm]     [dBc]      [dB]
          -50.000 k -25.000 k 300.00   901.944200 M -46.66     -91.26   -33.66
          -25.000 k -14.740 k 300.00   901.960100 M -37.27     -81.87   -17.27
          -14.740 k  -5.000 k 300.00   901.960500 M -37.08     -81.67   -18.52
            5.000 k  14.740 k 300.00   901.989600 M -37.47     -82.07   -18.31
           14.740 k  25.000 k 300.00   901.990000 M -34.89     -79.48   -14.89
           25.000 k  50.000 k 300.00   902.013100 M -45.43     -90.03   -32.43




  Date: 27.SEP.2018       13:39:42




                                                                                           Page 17 of 34


Rhein Tech Laboratories, Inc.                                                         Client: Harris Corporation
360 Herndon Parkway                                                                  Model #/HVIN: XT-MPS1M
Suite 1400                                                                    ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                       Standard: FCC Part 24
http://www.rheintech.com                                                               Report #: 2018025PCB

  Plot 7-5:         Occupied Bandwidth – 901.9750 MHz; 2-Level FSK 4800 XNB; Mask 24.133(2)
                                                                        Marker 1 [T1 ]
                                                                                  -55.21 dBm
         Ref    40 dBm                                                     902.025000000 MHz
                Offset   39.5 dB
          30                             LIMIT CHECK    PASS
          20                                                                                   A

          10
   1 SA *
   MAXH   0
                                                                                               LVL
          -10
          -20
          -30
         -40
   SPECT -50                                                                               13DB

         Center 901.975 MHz                   10 kHz/                          Span 100 kHz

          Tx Channel                                                           None
          Bandwidth              10 kHz         Power                   43.53 dBm
            Start     Stop     RBW       Freq        PwrAbs    PwrRel   ∆ Limit
            [Hz]      [Hz]     [Hz]      [Hz]         [dBm]     [dBc]      [dB]
          -50.000 k -25.000 k 300.00   901.938100 M -45.62     -89.15   -32.62
          -25.000 k -14.740 k 300.00   901.959300 M -40.19     -83.71   -20.19
          -14.740 k  -5.000 k 300.00   901.960600 M -40.03     -83.56   -22.07
            5.000 k  14.740 k 300.00   901.989500 M -38.84     -82.37   -20.29
           14.740 k  25.000 k 300.00   901.990000 M -39.92     -83.45   -19.92
           25.000 k  50.000 k 300.00   902.000500 M -47.46     -90.99   -34.46




  Date: 27.SEP.2018       14:04:21




                                                                                           Page 18 of 34


Rhein Tech Laboratories, Inc.                                                         Client: Harris Corporation
360 Herndon Parkway                                                                  Model #/HVIN: XT-MPS1M
Suite 1400                                                                    ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                       Standard: FCC Part 24
http://www.rheintech.com                                                               Report #: 2018025PCB

  Plot 7-6:         Occupied Bandwidth – 901.9750 MHz; P25; Mask 24.133(2)
                                                                        Marker 1 [T1 ]
                                                                                  -54.60 dBm
         Ref    40 dBm                                                     902.025000000 MHz
                Offset   39.5 dB
          30                             LIMIT CHECK    PASS
          20                                                                                   A

          10
   1 SA *
   MAXH   0
                                                                                               LVL
          -10
          -20
          -30
         -40
   SPECT -50                                                                               13DB


         Center 901.975 MHz                   10 kHz/                          Span 100 kHz

          Tx Channel                                                           None
          Bandwidth              10 kHz         Power                   43.89 dBm
            Start     Stop     RBW       Freq        PwrAbs    PwrRel   ∆ Limit
            [Hz]      [Hz]     [Hz]      [Hz]         [dBm]     [dBc]      [dB]
          -50.000 k -25.000 k 300.00   901.936000 M -46.36     -90.24   -33.36
          -25.000 k -14.740 k 300.00   901.958700 M -38.10     -81.98   -18.10
          -14.740 k  -5.000 k 300.00   901.960300 M -38.84     -82.73   -18.84
            5.000 k  14.740 k 300.00   901.989500 M -37.18     -81.07   -18.62
           14.740 k  25.000 k 300.00   901.990100 M -38.18     -82.06   -18.18
           25.000 k  50.000 k 300.00   902.013800 M -43.99     -87.88   -30.99




  Date: 27.SEP.2018       13:38:27




                                                                                           Page 19 of 34


Rhein Tech Laboratories, Inc.                                                        Client: Harris Corporation
360 Herndon Parkway                                                                 Model #/HVIN: XT-MPS1M
Suite 1400                                                                   ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                      Standard: FCC Part 24
http://www.rheintech.com                                                              Report #: 2018025PCB

  Plot 7-7:         Occupied Bandwidth – 901.9750 MHz; H-CPM (TDMA); Mask 24.133(2)
                                                                       Marker 1 [T1 ]
                                                                                 -55.98 dBm
         Ref    40 dBm                                                    902.025000000 MHz
                Offset   39.5 dB
          30                            LIMIT CHECK    PASS
          20                                                                                  A

          10
   1 SA *
   MAXH   0
                                                                                              LVL
          -10
          -20
          -30
         -40
   SPECT -50                                                                              13DB

         Center 901.975 MHz                  10 kHz/                          Span 100 kHz

          Tx Channel                                                          None
          Bandwidth              10 kHz         Power                  43.89 dBm
            Start     Stop     RBW       Freq        PwrAbs   PwrRel   ∆ Limit
            [Hz]      [Hz]     [Hz]      [Hz]         [dBm]    [dBc]      [dB]
          -50.000 k -25.000 k 300.00   901.936700 M -42.70    -86.59   -29.70
          -25.000 k -14.740 k 300.00   901.960200 M -36.55    -80.44   -16.55
          -14.740 k  -5.000 k 300.00   901.960300 M -36.97    -80.86   -16.97
            5.000 k  14.740 k 300.00   901.989500 M -39.17    -83.07   -20.62
           14.740 k  25.000 k 300.00   901.990000 M -35.86    -79.75   -15.86
           25.000 k  50.000 k 300.00   902.003900 M -41.33    -85.22   -28.33




  Date: 27.SEP.2018       14:01:59




                                                                                          Page 20 of 34


Rhein Tech Laboratories, Inc.                                                        Client: Harris Corporation
360 Herndon Parkway                                                                 Model #/HVIN: XT-MPS1M
Suite 1400                                                                   ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                      Standard: FCC Part 24
http://www.rheintech.com                                                              Report #: 2018025PCB

  Plot 7-8:         Occupied Bandwidth – 940.9750 MHz; NB Analog; Mask 24.133(2)
                                                                       Marker 1 [T1 ]
                                                                                  35.03 dBm
         Ref    40 dBm                                                    940.975000000 MHz
                                                1
                Offset   39.5 dB
          30                            LIMIT CHECK    PASS
          20                                                                                  A

          10
   1 RM *
   MAXH   0
                                                                                              LVL
          -10
          -20
          -30
         -40
   SPECT -50                                                                                  3DB

         Center 940.975 MHz                  10 kHz/                          Span 100 kHz

          Tx Channel                                                          None
          Bandwidth              10 kHz         Power                  38.49 dBm
            Start     Stop     RBW       Freq        PwrAbs   PwrRel   ∆ Limit
            [Hz]      [Hz]     [Hz]      [Hz]         [dBm]    [dBc]      [dB]
          -50.000 k -25.000 k 300.00   940.948500 M -43.03    -81.53   -30.03
          -25.000 k -14.740 k 300.00   940.960000 M -30.26    -68.75   -10.26
          -14.740 k  -5.000 k 300.00   940.960300 M -37.20    -75.69   -17.20
            5.000 k  14.740 k 300.00   940.987700 M -25.68    -64.18   -17.94
           14.740 k  25.000 k 300.00   940.990100 M -30.50    -69.00   -10.50
           25.000 k  50.000 k 300.00   941.002100 M -44.69    -83.18   -31.69




  Date: 27.SEP.2018       12:56:28




                                                                                          Page 21 of 34


Rhein Tech Laboratories, Inc.                                                                    Client: Harris Corporation
360 Herndon Parkway                                                                             Model #/HVIN: XT-MPS1M
Suite 1400                                                                               ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                                  Standard: FCC Part 24
http://www.rheintech.com                                                                          Report #: 2018025PCB

  Plot 7-9:         Occupied Bandwidth – 940.9750 MHz; WB Analog; Mask 24.133(1)
                                                                                   Marker 1 [T1 ]
                                                                                             -52.10 dBm
         Ref    50 dBm                                                                941.006600000 MHz
                Offset   39.5 dB
          40                                    LIMIT CHECK    PASS
          30                                                                                              A

          20
   1 SA *
   MAXH   10
                                                                                                          LVL
          0
          -10
          -20
         -30
   SPECT -40                                                                                              3DB
                                                                      1

         Center 940.975 MHz                          20 kHz/                              Span 200 kHz

          Tx Channel                                                                      None
          Bandwidth                       10 kHz         Power                     38.82 dBm
            Start          Stop         RBW       Freq        PwrAbs      PwrRel   ∆ Limit
            [Hz]           [Hz]         [Hz]      [Hz]         [dBm]       [dBc]      [dB]
         -100.000 k      -50.000   k   300.00   940.885800 M -47.33       -86.15   -34.33
          -50.000 k      -19.480   k   300.00   940.951800 M -41.32       -80.14   -21.32
          -19.480 k      -10.000   k   300.00   940.955600 M -49.53       -88.35   -29.53
           10.000 k       19.480   k   300.00   940.994000 M -44.98       -83.80   -27.94
           19.480 k       50.000   k   300.00   941.000600 M -43.46       -82.28   -23.46
           50.000 k      100.000   k   300.00   941.064400 M -44.78       -83.60   -31.78




  Date: 27.SEP.2018       14:34:30




                                                                                                      Page 22 of 34


Rhein Tech Laboratories, Inc.                                                                Client: Harris Corporation
360 Herndon Parkway                                                                         Model #/HVIN: XT-MPS1M
Suite 1400                                                                           ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                              Standard: FCC Part 24
http://www.rheintech.com                                                                      Report #: 2018025PCB

  Plot 7-10:        Occupied Bandwidth – 940.9750 MHz; 2-Level FSK 9600 WB; Mask 24.133(1)


         Ref    40 dBm
                Offset   39.5 dB
          30                                    LIMIT CHECK    PASS
          20                                                                                         A

          10
   1 SA *
   MAXH   0
                                                                                                     LVL
          -10
          -20
          -30
         -40
   SPECT -50                                                                                         3DB

         Center 940.975 MHz                          20 kHz/                          Span 200 kHz

          Tx Channel                                                                   None
          Bandwidth                       10 kHz         Power                  42.30 dBm
            Start          Stop         RBW       Freq        PwrAbs   PwrRel   ∆ Limit
            [Hz]           [Hz]         [Hz]      [Hz]         [dBm]    [dBc]      [dB]
         -100.000 k      -50.000   k   300.00   940.918200 M -43.48    -85.78   -30.48
          -50.000 k      -19.480   k   300.00   940.955400 M -27.46    -69.76    -7.46
          -19.480 k      -10.000   k   300.00   940.955600 M -24.93    -67.24    -4.93
           10.000 k       19.480   k   300.00   940.993800 M -23.39    -65.69    -7.59
           19.480 k       50.000   k   300.00   940.994480 M -25.87    -68.18    -5.87
           50.000 k      100.000   k   300.00   941.029400 M -44.45    -86.76   -31.45




  Date: 27.SEP.2018       13:28:07




                                                                                                  Page 23 of 34


Rhein Tech Laboratories, Inc.                                                         Client: Harris Corporation
360 Herndon Parkway                                                                  Model #/HVIN: XT-MPS1M
Suite 1400                                                                    ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                       Standard: FCC Part 24
http://www.rheintech.com                                                               Report #: 2018025PCB

  Plot 7-11:        Occupied Bandwidth – 940.9750 MHz; 2-Level FSK 9600 NB; Mask 24.133(2)
                                                                        Marker 1 [T1 ]
                                                                                  -52.51 dBm
         Ref    40 dBm                                                     941.025000000 MHz
                Offset   39.5 dB
          30                             LIMIT CHECK    PASS
          20                                                                                   A

          10
   1 SA *
   MAXH   0
                                                                                               LVL
          -10
          -20
          -30
         -40
   SPECT -50                                                                               13DB


         Center 940.975 MHz                   10 kHz/                          Span 100 kHz

          Tx Channel                                                           None
          Bandwidth              10 kHz         Power                   44.07 dBm
            Start     Stop     RBW       Freq        PwrAbs    PwrRel   ∆ Limit
            [Hz]      [Hz]     [Hz]      [Hz]         [dBm]     [dBc]      [dB]
          -50.000 k -25.000 k 300.00   940.949600 M -47.75     -91.81   -34.75
          -25.000 k -14.740 k 300.00   940.958700 M -38.11     -82.18   -18.11
          -14.740 k  -5.000 k 300.00   940.960300 M -39.24     -83.31   -19.24
            5.000 k  14.740 k 300.00   940.989600 M -38.70     -82.77   -19.54
           14.740 k  25.000 k 300.00   940.990400 M -37.39     -81.46   -17.39
           25.000 k  50.000 k 300.00   941.000600 M -44.87     -88.94   -31.87




  Date: 27.SEP.2018       13:34:19




                                                                                           Page 24 of 34


Rhein Tech Laboratories, Inc.                                                         Client: Harris Corporation
360 Herndon Parkway                                                                  Model #/HVIN: XT-MPS1M
Suite 1400                                                                    ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                       Standard: FCC Part 24
http://www.rheintech.com                                                               Report #: 2018025PCB

  Plot 7-12:        Occupied Bandwidth – 940.9750 MHz; 2-Level FSK 4800 XNB; Mask 24.133(2)
                                                                        Marker 1 [T1 ]
                                                                                  -52.28 dBm
         Ref    40 dBm                                                     940.925000000 MHz
                Offset   39.5 dB
          30                             LIMIT CHECK    PASS
          20                                                                                   A

          10
   1 SA *
   MAXH   0
                                                                                               LVL
          -10
          -20
          -30
          -40
   SPECT 1-50                                                                                  3DB

         Center 940.975 MHz                   10 kHz/                          Span 100 kHz

          Tx Channel                                                           None
          Bandwidth              10 kHz         Power                   42.37 dBm
            Start     Stop     RBW       Freq        PwrAbs    PwrRel   ∆ Limit
            [Hz]      [Hz]     [Hz]      [Hz]         [dBm]     [dBc]      [dB]
          -50.000 k -25.000 k 300.00   940.936200 M -49.34     -91.71   -36.34
          -25.000 k -14.740 k 300.00   940.960100 M -42.23     -84.60   -22.23
          -14.740 k  -5.000 k 300.00   940.960500 M -39.66     -82.03   -21.10
            5.000 k  14.740 k 300.00   940.989300 M -41.45     -83.82   -24.09
           14.740 k  25.000 k 300.00   940.990700 M -42.39     -84.76   -22.39
           25.000 k  50.000 k 300.00   941.013400 M -47.67     -90.05   -34.67




  Date: 27.SEP.2018       14:07:43




                                                                                           Page 25 of 34


Rhein Tech Laboratories, Inc.                                                         Client: Harris Corporation
360 Herndon Parkway                                                                  Model #/HVIN: XT-MPS1M
Suite 1400                                                                    ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                       Standard: FCC Part 24
http://www.rheintech.com                                                               Report #: 2018025PCB

  Plot 7-13:        Occupied Bandwidth – 940.9750 MHz; P25; Mask 24.133(2)
                                                                        Marker 1 [T1 ]
                                                                                  -50.45 dBm
         Ref    40 dBm                                                     941.025000000 MHz
                Offset   39.5 dB
          30                             LIMIT CHECK    PASS
          20                                                                                   A

          10
   1 SA *
   MAXH   0
                                                                                               LVL
          -10
          -20
          -30
         -40
                                                                                           1
   SPECT -50                                                                                3DB

         Center 940.975 MHz                   10 kHz/                          Span 100 kHz

          Tx Channel                                                           None
          Bandwidth              10 kHz         Power                   44.22 dBm
            Start     Stop     RBW       Freq        PwrAbs    PwrRel   ∆ Limit
            [Hz]      [Hz]     [Hz]      [Hz]         [dBm]     [dBc]      [dB]
          -50.000 k -25.000 k 300.00   940.949600 M -44.71     -88.93   -31.71
          -25.000 k -14.740 k 300.00   940.960200 M -39.43     -83.65   -19.43
          -14.740 k  -5.000 k 300.00   940.960300 M -40.67     -84.89   -20.67
            5.000 k  14.740 k 300.00   940.989500 M -39.59     -83.81   -21.03
           14.740 k  25.000 k 300.00   940.990400 M -37.78     -82.00   -17.78
           25.000 k  50.000 k 300.00   941.000500 M -43.29     -87.51   -30.29




  Date: 27.SEP.2018       13:33:07




                                                                                           Page 26 of 34


Rhein Tech Laboratories, Inc.                                                         Client: Harris Corporation
360 Herndon Parkway                                                                  Model #/HVIN: XT-MPS1M
Suite 1400                                                                    ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                       Standard: FCC Part 24
http://www.rheintech.com                                                               Report #: 2018025PCB

  Plot 7-14:        Occupied Bandwidth – 940.9750 MHz; H-CPM (TDMA); Mask 24.133(2)
                                                                        Marker 1 [T1 ]
                                                                                  -55.31 dBm
         Ref    40 dBm                                                     940.925000000 MHz
                Offset   39.5 dB
          30                            LIMIT CHECK    PASS
          20                                                                                   A

          10
   1 SA *
   MAXH   0
                                                                                               LVL
          -10
          -20
          -30
          -40
   SPECT 1-50                                                                                  3DB

         Center 940.975 MHz                  10 kHz/                           Span 100 kHz

          Tx Channel                                                           None
          Bandwidth              10 kHz         Power                   43.16 dBm
            Start     Stop     RBW       Freq        PwrAbs    PwrRel   ∆ Limit
            [Hz]      [Hz]     [Hz]      [Hz]         [dBm]     [dBc]      [dB]
          -50.000 k -25.000 k 300.00   940.949800 M -38.51     -81.67   -25.51
          -25.000 k -14.740 k 300.00   940.960100 M -28.18     -71.34    -8.18
          -14.740 k  -5.000 k 300.00   940.960500 M -28.13     -71.29    -9.58
            5.000 k  14.740 k 300.00   940.989500 M -26.90     -70.05    -8.34
           14.740 k  25.000 k 300.00   940.989740 M -27.57     -70.73    -7.57
           25.000 k  50.000 k 300.00   941.000700 M -39.24     -82.40   -26.24




  Date: 27.SEP.2018       13:59:25



  Measurement uncertainties shown for these tests are expanded uncertainties expressed at the 95%
  confidence level using a coverage factor K=2. Measurement uncertainty: ±0.5 Hz

  Results: Pass




                                                                                           Page 27 of 34


Rhein Tech Laboratories, Inc.                                                      Client: Harris Corporation
360 Herndon Parkway                                                               Model #/HVIN: XT-MPS1M
Suite 1400                                                                 ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                    Standard: FCC Part 24
http://www.rheintech.com                                                            Report #: 2018025PCB

  Table 7-1:       Test Equipment Used For Testing Occupied Bandwidth

                                                                                Serial         Calibration
  RTL Asset #        Manufacturer    Model                  Part Type
                                                                               Number           Due Date

                       Rohde &
     901581                           FSU            Spectrum Analyzer      1166.1660.50         4/26/21
                       Schwarz
                       Weinschel     48-20-34
     901724                                        Attenuator, 100W 20dB       CJ8921             8/7/19
                         Corp.      DC-18GHz
                        Hewlett                       Synthesizer/Level
     901057                          3336B                                  2514A02585           1/31/20
                       Packard                           Generator

  Test Personnel:


           Daniel Baltzell                                                 September 27, 2018
         EMC Test Engineer                      Signature                     Date of Test




                                                                                        Page 28 of 34


Rhein Tech Laboratories, Inc.                                                               Client: Harris Corporation
360 Herndon Parkway                                                                        Model #/HVIN: XT-MPS1M
Suite 1400                                                                          ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                             Standard: FCC Part 24
http://www.rheintech.com                                                                     Report #: 2018025PCB

  8     FCC Part 2.1055: Frequency Stability; Part 24.135: Frequency Stability

  8.1    Test Procedure

  ANSI C63.26, section 5.6

  The carrier frequency stability is the ability of the transmitter to maintain an assigned carrier frequency.

  The EUT was evaluated over the temperature range -30°C to +60°C. The AFC was not locked to the base
  station.

  Note: Though the frequency tested below is not within the Part 24 frequency allocations, it is representative of
  the frequency stability for the entire 900 MHz band.

  The temperature was initially set to -30°C and a 1-hour period was observed for stabilization of the EUT. The
  frequency stability was measured within one minute after application of primary power to the transmitter. The
  temperature was raised at intervals of 10 degrees centigrade through the range. A ½-hour period was
  observed to stabilize the EUT at each measurement step and the frequency stability was measured within
  one minute after application of primary power to the transmitter. Additionally, the power supply voltage of the
  EUT was varied +/-15% nominal input voltage.

  Part 24.135: Frequency Stability

  (a) The frequency stability of the transmitter shall be maintained within ±0.0001 percent (±1 ppm) of the
  center frequency over a temperature variation of -30° Celsius to +60° Celsius at normal supply voltage, and
  over a variation in the primary supply voltage of 85 percent to 115 percent of the rated supply voltage at a
  temperature of 20° Celsius.
  (b) For battery operated equipment, the equipment tests shall be performed using a new battery without any
  further requirement to vary supply voltage.
  (c) It is acceptable for a transmitter to meet this frequency stability requirement over a narrower temperature
  range provided the transmitter ceases to function before it exceeds these frequency stability limits.

  8.2    Test Data

  Table 8-1:      Temperature Frequency Stability – 937.5 MHz
          Temperature (°C)            Measured Frequency (Hz)                                  ppm
                   -30                        937.500031                                        0.03
                   -20                        937.500000                                        0.00
                   -10                        937.500016                                        0.02
                     0                        937.500027                                        0.03
                    10                        937.499949                                       -0.05
             20 (reference)                   937.500000                                        0.00
                    30                        937.500031                                        0.03
                    40                        937.500051                                        0.05
                    50                        937.500125                                        0.13
                    55                        937.500086                                        0.09
                    60                        937.500063                                        0.07

  Measurement uncertainties shown for these tests are expanded uncertainties expressed at the 95%
  confidence level using a coverage factor K=2. Measurement uncertainty: ±0.5 Hz

  Results: Pass

                                                                                                 Page 29 of 34


Rhein Tech Laboratories, Inc.                                                       Client: Harris Corporation
360 Herndon Parkway                                                                Model #/HVIN: XT-MPS1M
Suite 1400                                                                  ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                     Standard: FCC Part 24
http://www.rheintech.com                                                             Report #: 2018025PCB

  Table 8-2:     Test Equipment Used For Testing Temperature Frequency Stability
    RTL                                                                     Serial                Calibration
             Manufacturer        Model                 Part Type
  Asset #                                                                 Number                   Due Date
  901350       Meterman          33XR                  Multimeter        040402802                  4/26/19
               Rohde &
  901672                        FSEM30             Spectrum Analyzer      FSEM30                    4/17/19
               Schwarz
             API Weinschel,
  901724                        48-40-34         40 dB 100W Attenuator     CJ8921                   8/7/19
                  Inc.
                                                                                                     Not
  901124           Alinco       DM-33MVT 32A             Power Supply              1638
                                                                                                   Required

  Test Personnel:


            Daniel Baltzell                                                  September 3, 2018
          EMC Test Engineer                    Signature                        Date of Test


  8.2.1    Frequency Stability/Voltage Variation

  Table 8-3:       Frequency Stability/Voltage Variation – 937.5 MHz
               Voltage (VDC)                 Measured Frequency (Hz)                       ppm
                    11.56                            937.500031                            0.03
               13.6(reference)                       937.500000                            0.00
                    15.64                            937.500000                            0.00

  Measurement uncertainties shown for these tests are expanded uncertainties expressed at the 95%
  confidence level using a coverage factor K=2. Measurement uncertainty: ±0.5 Hz

  Results: Pass

  Table 8-4:     Test Equipment Used For Testing Frequency Stability/Voltage Variation
    RTL                                                                       Serial              Calibration
             Manufacturer        Model                 Part Type
  Asset #                                                                    Number                Due Date
  901350       Meterman          33XR                  Multimeter           040402802               4/26/19
               Rohde &
  901672                        FSEM30             Spectrum Analyzer         FSEM30                 4/17/19
               Schwarz
             API Weinschel,
  901724                        48-40-34         40 dB 100W Attenuator       CJ8921                 8/7/19
                  Inc.
                                                                                                     Not
  901124           Alinco       DM-33MVT 32A             Power Supply              1638
                                                                                                   Required

  Test Personnel:


            Daniel Baltzell                                                  September 3, 2018
          EMC Test Engineer                    Signature                        Date of Test




                                                                                          Page 30 of 34


Rhein Tech Laboratories, Inc.                                               Client: Harris Corporation
360 Herndon Parkway                                                        Model #/HVIN: XT-MPS1M
Suite 1400                                                          ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                             Standard: FCC Part 24
http://www.rheintech.com                                                     Report #: 2018025PCB

  9    FCC Part 2.202: Necessary Bandwidth and Emission Bandwidth

  Voice – 12.5 kHz channel separation
  Calculation:
  Max modulation (M) in kHz: 3.0
  Max deviation (D) in kHz: 2.5
  Constant factor (K): 1 (assumed)
  Bn = 2xM+2xDK = 11.0 kHz
  Emission designator: 11K0F3E

  Voice – 25 kHz channel separation
  Calculation:
  Max modulation (M) in kHz: 3.0
  Max deviation (D) in kHz: 5
  Constant factor (K): 1 (assumed)
  Bn = 2M+2DK = 16.0 kHz
  Emission designator: 16K0F3E

  P25 – 9600 bps
  Calculation:
  Data rate in bps (R) = 9600
  Peak deviation of carrier (D) = 1800
  Bn = [9600/log2(4) + 2 (1800) (1) = 8.400 kHz
  Emission designator: 8K40F1D, 8K40F1E

  P25 Phase 2 Data/Voice (H-CPM TDMA)
  Calculation:
  Data rate in bps (R) =12000
  Peak deviation of carrier (D) = 1050
  Bn = [12000/log2(4) + 2 (1050) (1) = 8.1 kHz
  Emission designator: 8K10DXW

  2-level FSK 9600 Data/Digital Voice (NB)
  Calculation:
  Data rate in bps (R) = 9600
  Peak deviation of carrier (D) = 3450
  Bn = [9600/log2(4) + 2 (3450) (1) = 11.700 kHz
  Emission designator: 11K7F1D, 11K7F1E

  2-level FSK 9600 Data/Digital Voice (WB)
  Calculation:
  Data rate in bps (R) = 9600
  Peak deviation of carrier (D) = 5600
  Bn = [9600/log2(4) + 2 (5600) (1) = 16.000 kHz
  Emission designator: 16K0F1D, 16K0F1E

  2-level FSK 4800 Data/Digital Voice (XNB)
  Calculation:
  Data rate in bps (R) = 4800
  Peak deviation of carrier (D) = 1800
  Bn = [4800/log2(4) + 2 (2350) (1) = 7.100 kHz
  Emission designator: 7K10F1D, 7K10F1E




                                                                                 Page 31 of 34


Rhein Tech Laboratories, Inc.                                                     Client: Harris Corporation
360 Herndon Parkway                                                              Model #/HVIN: XT-MPS1M
Suite 1400                                                                ID’s: OWDTR-0160-E/3636B-0160
Herndon, VA20170                                                                   Standard: FCC Part 24
http://www.rheintech.com                                                           Report #: 2018025PCB

  10   Conclusion

  The data in this measurement report shows that the Harris Corporation XL-185M, Model #/HVIN XT-MPS1M,
  FCC ID: OWDTR-0160-E, complies with the applicable requirements of Parts 2 and 24 of the FCC Rules.




                                                                                       Page 32 of 34



Document Created: 2018-09-27 14:42:42
Document Modified: 2018-09-27 14:42:42

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC