Users Manual

FCC ID: OW8LSMC01400

Users Manual

Download: PDF
FCCID_101305

     ®
PN XXXXXXXXXX




          Local Status Monitor
              LSM controller
   Installation and Operation Manual




                      CAUTION In order to comply with FCC RF
                      exposure requirements, this device must be
                      installed in such a way as to ensure that a
                      minimum separation distance of 20 cm is always
                      maintained between the antenna and all persons.



                Note: This equipment has been tested and found to comply with the limits for
                a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are
                designed to provide reasonable protection against harmful interference when
                the equipment is operated in a commercial environment. This equipment
                generates, uses, and can radiate radio frequency energy and if not installed and
                used in accordance with the instruction manual, may cause harmful
                interference to radio communications. Operation of this equipment in a
                residential area is likely to cause harmful interference in which case the user
                will be required to correct the interference at his own expense.


Local Status Monitor/Controller Installation/Operation Manual
PN XXXXXXXXXX



Section 1 -- Table of Contents


SECTION 1 -- TABLE OF CONTENTS _______________________________ 2

SECTION 2 -- INTRODUCTION _____________________________________ 3

SECTION 3 – PRODUCT OVERVIEW________________________________ 4
 3a.   Wireless SoftLink ______________________________________________________________4
 3b.   Local Status Monitor Controller (LSMC) ____________________________________________4
 3c.   Local Status Monitor (LSM)______________________________________________________4
 3d.   Craft Software_________________________________________________________________4


SECTION 4 – HARDWARE INSTALLATION __________________________ 5
 a. Network Amplifier_______________________________________________________________5


SECTION 4 – HARDWARE INSTALLATION __________________________ 9
 b. Line Extender__________________________________________________________________9


SECTION 5 – WIRELESS SOFTLINK SOFTWARE INSTALLATION _______ 13
 Step 1   _________________________________________________________________________ 13
 Step 2   _________________________________________________________________________ 13
 Step 3   _________________________________________________________________________ 13
 Step 4   _________________________________________________________________________ 13


SECTION 6 – OPERATION _______________________________________ 14
 a. Introduction___________________________________________________________________ 14
 b. Initializing____________________________________________________________________ 14
 b1 – WSL Setup _________________________________________________________________ 14
 b2 -- LSM Setup____________________________________________________________________ 15
 c. Operation_______________________________________________________________________ 16



SECTION 7 -- INDEX_____________________________________________17




\\Adcvs4\vol2\COMMON\00Sawyer\LSM Manual 4-21-00.doc     Created on 04/21/00 10:34 AM
Page 2 of 6


Local Status Monitor/Controller Installation/Operation Manual
PN XXXXXXXXXX




Section 2 -- Introduction
       The purpose of the Local Status Monitor/Controller Installation/Operation Manual is to provide a
       user-friendly and comprehensive document that makes it easy for technicians to install and operate
       the LSM/LSMC. The manual includes step-by-step LSM/LSMC installation/operation
       instructions and accompanying graphics.

       The information contained in this document is current as of the date of publication and is also
       compatible with the most recent release of Craft Software as well as the initial release of the
       LSM/LSMC software. ADC retains the right to change this document, in part or in whole, without
       prior notice.

       This document is copyrighted. All rights are reserved. This document may not, in whole or in
       part be reproduced or transmitted in any form or by any means electronic or mechanical, without
       the express written consent from ADC.

       In no event will ADC be liable for any special, incidental, or consequential damages or
       commercial losses, even if ADC has been advised thereof, as a result of issue of this publication.




\\Adcvs4\vol2\COMMON\00Sawyer\LSM Manual 4-21-00.doc              Created on 04/21/00 10:34 AM
Page 3 of 6


Local Status Monitor/Controller Installation/Operation Manual
PN XXXXXXXXXX



Section 3 – Product Overview

       3a. Wireless SoftLink

       The Wireless SoftLink, WSL, operates in conjunction with Craft and controls LSMC via an
       RS232 connection. The WSL software enables technicians to address amplifiers with a local
       status monitor/local status monitor controller via the Craft software .

       The WSL can be loaded in any personal computer, or laptop. It must have Craft version 2.0 or
       higher version software installed to operate properly with the LSM and LSMC. ADC maintains
       helpdesk technical support to assist with any Craft or Wireless SoftLink software installation or
       operation issue. You will find complete LSM/LSMC installation/operation instructions in Section
       4 of this manual.

       3b. Local Status Monitor Controller (LSMC)

       The Local Status Monitor Controller, LSMC, is a wireless communication module connected to a
       laptop. The main purpose for the LSMC is to become a two-way wireless link between a ground
       located laptop and the ADC family of Network Amplifiers or Line Extender.

       The LSMC will allow Craft software to control the network amplifier through a wireless
       connection. Technicians can operate the LSMC in a vehicle or attach the LSMC to the belt with a
       clip attached to the LSMC case.

       For optimal performance the LSMC should remain relatively stationary during use to prevent any
       interruption or disconnection of the wireless link with the LSM.

       3c. Local Status Monitor (LSM)

       The Local Status Monitor is an upgrade kit that can be installed in an amplifier. The LSM works
       in conjunction with the LSM controller as a wireless link to receive commands from a laptop.
       Once LSM receives command, it will send commands to the ADC family of network amplifier or
       Line Extender. The LSM will function properly with Craft version 2.0 or higher version software.

       The LSM will allow the operator to monitor and adjust the operating status of the RF amplifier
       without opening the housing.
       The Local Status Monitor receives the seeking transmission from the LSMC and responds to the
       LSMC 1) to confirm a proper connection and 2) to establish correspondence with the WSL. Once
       the LSM has established the connection with Craft, the technician can perform remotely Craft
       functions with the amplifier. The LSM/LSMC enables the technician to save valuable time and
       energy, and avoid hazardous or unpleasant weather conditions.

       3d. Craft Software

       For questions regarding Craft software please refer to the Craft Software Installation/Operation
       Manual.




\\Adcvs4\vol2\COMMON\00Sawyer\LSM Manual 4-21-00.doc              Created on 04/21/00 10:34 AM
Page 4 of 6


Local Status Monitor/Controller Installation/Operation Manual
PN XXXXXXXXXX



Section 4 – Hardware Installation

                         CAUTION In order to comply with FCC RF exposure
                         requirements, this device must be installed in such a way as to
                         ensure that a minimum separation distance of 20 cm is always
                         maintained between the antenna and all persons.




         a. Network Amplifier

                       Note: ADC designed the Network Amplifier tray to be reversible. If further
                       instructions are required for reverse installation, see application note. The Network
                       Amplifier cover, tightened correctly, will provide an air tight internal amplifier
                       chamber. To preserve optimal amplifier operating conditions, carefully and exactly
                       follow this manual’s instructions for removing and fastening the Network Amplifier
                       housing cover.


S TEP 1
                                           Retainer clips
Verify that the replacement kit
includes all the necessary
                                             Antenna
components. All the following
should be included in the installation    Housing cover
kit:
                                          Interface Cable

                                         LSM circuit board

                                          Housing bolts


                                                              Figure 4-1

S TEP 2
Locate the six 5/16-18” bolts holding the housing cover
to the base. Loosen all six bolts with a 1/2” wrench.
Be sure to follow the pattern numbers in the diagram at
the right for loosening the bolts. The bolts are spring-
loaded and will pop up when loosened. Do not attempt
to remove bolts. They are fixed to the lid. The
numbers in Figure 4-2 indicate the pattern for installing
the replacement amplifier lid. Reverse the pattern for
removing the lid from the amplifier. The numbers are
engraved onto the lid.                                       Figure 4-2




\\Adcvs4\vol2\COMMON\00Sawyer\LSM Manual 4-21-00.doc                 Created on 04/21/00 10:34 AM
Page 5 of 6


Local Status Monitor/Controller Installation/Operation Manual
PN XXXXXXXXXX

S TEP 3
Locate the two retainer clips on the Network Amplifier’s hinge posts . Use a
flathead screwdriver to gently pry the clips from each hinge post.




S TEP 4                                                                               Figure 4-3
Carefully remove the Network Amplifier housing cover and set aside.


S TEP 5
Verify that all components on the replacement kit lid are installed
properly and in the correct position. Figure 4-4 illustrates an installed LSM
kit. The Local Status Monitor circuit board with antenna should be
installed in the housing cover. When the LSM unit is installed, the
interface cable will attach through the RF tray cover to the connector in
the Network Amplifier tray.
                                                                                Figure 4-4




                    CAUTION: The LSM unit antenna is attached
                    to the LSM printed wiring board, or PWB,
                   through the housing cover. Any attempt to
                   remove the antenna or reposition or remove
                   the LSM unit could cause serious damage to
                   the function of the Network Amplifier.
                   Under no circumstances should any
                   technician attempt to make adjustments or
                   changes to the LSM unit in its installed              Figure 4-5
                   position.


S TEP 6
Remove the RF tray cover using a No. 1 Phillips
screwdriver to loosen the eight RF tray cover screws
(nine if reverse amplifier is installed) until there is
approximately 1/8 in. (about 3mm) clearance                                                   Figure 4-7
between the bottom of the screw head and the
surface of the RF tray cover. Slide the RF tray
cover until the screw heads are aligned in their
keyway slots and lift RF tray cover off the tray.         Figure 4-6                          Figure 4-8
Then unsnap the connector from the amplifier tray.


               Note: Do not shortcut the installation process by removing only the screw near
               the cable insertion slot on the RF tray cover.

              Note: The keyway feature allows the RF tray cover to be removed without fully removing
              the RF tray cover screws, preventing loss of the screws.




\\Adcvs4\vol2\COMMON\00Sawyer\LSM Manual 4-21-00.doc                   Created on 04/21/00 10:34 AM
Page 6 of 6


Local Status Monitor/Controller Installation/Operation Manual
PN XXXXXXXXXX



S TEP 7

Slide the new amplifier cover onto the hinge posts . See Figure 4-9. Do not
secure the cover with the retainer clips during this step.


                                                                                      Figure 4-9

S TEP 8
Locate the connector slot in the amplifier tray where you will install the
interface cable. See Figure 4-10.




                                                                                      Figure 4-10



S TEP 9
Carefully insert the interface cable into the connector. The cable and
connector are keyed, so they will only fit together in the correct position.
Make sure the cable is folded. Firmly fit the interface cable into the
amplifier. See Figure 4-11. Do not force the insertion.

                                                                                          Figure 4-11


S TEP 10
Replace the amplifier RF tray cover by passing the tray cover screws back
through the keyway slots, sliding the cover until the screw heads are over the
narrowest part of the keyway slots. Refer to Figure 4-12. Tighten the RF tray
cover screws with a No. 1 Phillips screwdriver.

                                                                                             Figure 4-12



S TEP 11
Remove any excess moisture or debris from the interior of the Network Amplifier and the Network
Amplifier tray. If any moisture has accumulated during the installation process, use a clean, dry cotton
cloth to wipe off the housing unit and tray. Although this unit is extremely tolerant of a variety of
environmental conditions, you can enhance the service life of the amplifier by insuring that it is clean and
free of any moisture before closing.

S TEP 12
Close the housing lid and align it squarely with the housing base. Thread all six
housing lid bolts finger-tight to hold the lid in place. Make sure the lid bolts do not
cross thread. The numbered pattern for installing the housing is engraved on the
housing cover.
                                                                                            Figure 4-13




\\Adcvs4\vol2\COMMON\00Sawyer\LSM Manual 4-21-00.doc                   Created on 04/21/00 10:34 AM
Page 7 of 6


Local Status Monitor/Controller Installation/Operation Manual
PN XXXXXXXXXX




S TEP 13
Tighten down the lid bolts. Follow the pattern of the numbers engraved in the
amplifier lid. Use a ½” socket or torque wrench specifically designed to apply
the necessary 5-12 lb.ft (7-16 N·m) of torque to tighten the housing lid bolts.


                                                                                    Figure 4-14



                                    The use of any but the specified tool may result in
                                    excess or incorrect torque on the lid bolts.
                                    Incorrect torque could also damage amplifier
                                    functions and prevent the amplifier from
                                    maintaining its airtight seal.



S TEP 14
Place one new retainer clip on each Network Amplifier hinge post. Firmly secure the retainer clips onto the
posts. Lightly tap the clips onto each post with a hammer until the clips fit snugly on the posts.




\\Adcvs4\vol2\COMMON\00Sawyer\LSM Manual 4-21-00.doc                Created on 04/21/00 10:34 AM
Page 8 of 6


Local Status Monitor/Controller Installation/Operation Manual
PN XXXXXXXXXX



Section 4 – Hardware Installation

                         CAUTION In order to comply with FCC RF exposure
                         requirements, this device must be installed in such a way as to
                         ensure that a minimum separation distance of 20 cm is always
                         maintained between the antenna and all persons.

         b. Line Extender

                       Note: ADC designed the Line Extender tray to be reversible. If further instructions
                       are required for reverse installation, see application note. The Line Extender cover,
                       tightened correctly, will provide an air tight internal amplifier chamber. To preserve
                       optimal amplifier operating conditions, carefully and exactly follow this manual’s
                       instructions for removing and fastening the Line Extender housing cover.


S TEP 1
Verify that the replacement kit includes all the necessary components. All the following should be
included in the installation kit:




S TEP 2
Locate the four 5/16-18” bolts holding the housing cover to the base. Loosen all four bolts with a 1/2”
wrench. Be sure to follow the pattern numbers in the diagram at the right for loosening the bolts. The bolts
are spring-loaded and will pop up when loosened. Do not attempt to remove bolts. They are fixed to the
lid. The numbers in Figure 4-2 indicate the pattern for installing the replacement amplifier lid. Reverse the
pattern for removing the lid from the amplifier. The numbers are engraved onto the lid.

S TEP 3
Locate the two retainer clips on the Line Extender’s hinge posts. Use a flathead screwdriver to gently pry
the clips from each hinge post.

S TEP 4
Carefully remove the Line Extender housing cover and set aside.




S TEP 5
Verify that all components on the replacement kit lid are installed properly and in the correct position.
Figure 4-4 illustrates an installed LSM kit. The Local Status Monitor circuit board with antenna should be
installed in the housing cover. When the LSM unit is installed, the interface cable will attach through the
RF tray cover to the connector in the Line Extender tray.




\\Adcvs4\vol2\COMMON\00Sawyer\LSM Manual 4-21-00.doc                Created on 04/21/00 10:34 AM
Page 9 of 6


Local Status Monitor/Controller Installation/Operation Manual
PN XXXXXXXXXX


                            CAUTION: The LSM unit antenna is
                            attached to the LSM printed wiring
                            board, or PWB, through the housing
                            cover. Any attempt to remove the
                            antenna or reposition or remove the
                            LSM unit could cause serious
                            damage to the function of the Line
                            Extender. Under no circumstances
                            should any technician attempt to
                            make adjustments or changes to the
                            LSM unit in its installed position.



S TEP 6
Remove the RF tray cover using a No. 1 Phillips screwdriver to loosen the seven RF tray cover screws
(eight if reverse amplifier is installed, ten if AGC is installed) until there is approximately 1/8 in. (about
3mm) clearance between the bottom of the screw head and the surface of the RF tray cover. If the AGC is
present, completely remove the two screws at the Craft Interface connector. Slide the RF tray cover until
the screw heads are aligned in their keyway slots and lift RF tray cover off the tray. Then unsnap the
connector from the amplifier tray.

                  Note: Do not shortcut the installation process by removing only the screw
                  near the cable insertion slot on the RF tray cover.

                  Note: The keyway feature allows the RF tray cover to be removed without fully
                  removing the RF tray cover screws, preventing loss of the screws.



                        CAUTION: Do not lose the bolts or AGC interface connector screws.



S TEP 7

Slide the new amplifier cover onto the hinge posts. See Figure 4-9. Do not secure the cover with the retainer
clips during this step.


                                                                                          Figure 4-9



S TEP 8
Locate the connector on the AGC plug-in module where you will install the interface cable. See Figure 4-10.




S TEP 9
Carefully insert the interface cable into the connector. the cable and connector are keyed, so they will only
fit together in the correct position. Make sure the cable is folded. Firmly fit the interface cable into the
amplifier. See Figure 4-11. Do not force the insertion.


\\Adcvs4\vol2\COMMON\00Sawyer\LSM Manual 4-21-00.doc                  Created on 04/21/00 10:34 AM
Page 10 of 6


Local Status Monitor/Controller Installation/Operation Manual
PN XXXXXXXXXX




S TEP 10
Replace the amplifier RF tray cover by passing the tray cover screws back through the keyway slots,
sliding the cover until the screw heads are over the narrowest part of the keyway slots. Refer to Figure 4-12.
Tighten the RF tray cover screws with a No. 1 Phillips screwdriver.




                            Note Do not forget to reinstall the two AGC
                            screws if AGC is insalled.


S TEP 11
Remove any excess moisture or debris from the interior of the Line Extender and the Line Extender tray. If
any moisture has accumulated during the installation process, use a clean, dry cotton cloth to wipe off the
housing unit and tray. Although this unit is extremely tolerant of a variety of environmental conditions,
you can enhance the service life of the amplifier by insuring that it is clean and free of any moisture before
closing.

S TEP 12
Close the housing lid and align it squarely with the housing base. Thread all four
housing lid bolts finger-tight to hold the lid in place. Make sure the lid bolts do not
cross thread. The numbered pattern for installing the housing is engraved on the
housing cover.
                                                                                          Figure 4-13

S TEP 13
Tighten down the lid bolts. Follow the pattern of the numbers engraved in the amplifier lid. Use a ½”
socket or torque wrench specifically designed to apply the necessary 5-12 lb.ft (7-16 N·m) of torque to
tighten the housing lid bolts.




                The use of any but the specified tool may result in incorrect torque on
                the lid bolts. Incorrect torque could damage amplifier functions and
                prevent the amplifier from maintaining its airtight seal.



S TEP 14



\\Adcvs4\vol2\COMMON\00Sawyer\LSM Manual 4-21-00.doc                  Created on 04/21/00 10:34 AM
Page 11 of 6




Local Status Monitor/Controller Installation/Operation Manual
PN XXXXXXXXXX



Section 5 – Wireless SoftLink Software Installation
       Step 1
       Insert the 3 ½” floppy disk labeled “Wireless SoftLink Installation Disk 1” into the floppy drive.

       Step 2
       In the Windows toolbar click on “Start”, then click on “ Run.”

       Step 3
       Type “a:\s etup.exe” in the window and press “Enter” where a:\ is the floppy drive destination.

       Step 4
       Follow the instructions on the screen for installation of the Wireless SoftLink Software.




\\Adcvs4\vol2\COMMON\00Sawyer\LSM Manual 4-21-00.doc                  Created on 04/21/00 10:34 AM
Page 13 of 6


Local Status Monitor/Controller Installation/Operation Manual
PN XXXXXXXXXX



Section 6 – Operation
       a. Introduction
       The Wireless SoftLink is a software program that operates a Local Status Monitor
       Controller. The WSL will allow operator to run Craft software through a wireless
       connection to operate and to monitor the ADC family of Network Amplifiers and
       Line Extender.


       b. Initializing

                             Warning: The LSM Initialization is required. If a technician
                             does not perform the LSM configuration the target LSM will
                             fail to respond. Follow the installation sequence in the exact
                             order listed.



       b1 – WSL Setup
                                                                 WSL Setup

       Press the WSL Setup button. Watch the status bar at the
       bottom of the screen. During the install test the status bar
       will display “Searching,” “Connecting” or “Finished.” When
       the test is finished, proceed to step 2.


                                                                             Figure 6-1




\\Adcvs4\vol2\COMMON\00Sawyer\LSM Manual 4-21-00.doc             Created on 04/21/00 10:34 AM
Page 14 of 6


  c— Operation

  Step 1                                                  Polling button
 Preas the Poling button to iniiste the search for
 L3Ms. Soe Figure 6—3.




                                                                            Faures.s


 As the WSL polls in the target ares and focstes LSM‘s,the WSL screen will display the amplifier
 electronic eesial numbers in the ecteen window. A user—selectedname of up to 30 characters may
 eppeet, if the neme has been previously and menually entered into the amplifier. See Flgure 6—4
Step 2
Mositor the screen window, the progress bar and      LSMSearchresutsl
the scrolling information ber at the bottom of the
sereen. The technicien can connect when the desired              Progress
amplifier sppeats in the ecreen window. See Figure 54.


Step 3
Highlight and select the appropriate amplifier
in the soreen window. Seo Figue 6—5. Press the               Connect
conneet button




When the LSMC locates and connects with the
spprogriate LSM, the approptiate LSM senial oumber will
sppear in the information bar at the bottom of the screen. See
Foure 6—6

                                                                            Figure 6—6


Local Status Monitor/Controller Installation/Operation Manual
PN XXXXXXXXXX




                                                       Figure 6-10




\\Adcvs4\vol2\COMMON\00Sawyer\LSM Manual 4-21-00.doc   Created on 04/21/00 10:34 AM
Page 16 of 6


Local Status Monitor/Controller Installation/Operation Manual
PN XXXXXXXXXX




Section 7 -- Index

                        A                               Local Status Monitor______________________4
ADC ________________________________ 3                  Local Status Monitor Controller ______________4
Antenna ______________________________ 5                Local Status Monitor/Controller ______________3
                                                        LSM circuit board _______________________5
                                                        LSMC _______________________________4
                        C
CAUTION ____________________________                5                         N
Craft ________________________________              4
Craft software __________________________           4   Network Amplifier ________________ 4, 5, 6, 7, 8
Craft Software __________________________           3
Craft Software Installation/Operation Manual ____   4                          P
                                                        Product Overview________________________4
                        E
exposure requirements____________________ 5                                   R
                                                        Retainer clips___________________________5
                        H                               RS232________________________________4
housing bolts __________________________ 5
housing cover __________________________ 5                                     S
                                                        SoftLink ______________________________4
                        I
interface cable __________________________ 5                                  W
                                                        Wireless SoftLink________________________4
                        L
Line Extender __________________________ 4




\\Adcvs4\vol2\COMMON\00Sawyer\LSM Manual 4-21-00.doc            Created on 04/21/00 10:34 AM
Page 17 of 6





Document Created: 2019-09-25 05:51:49
Document Modified: 2019-09-25 05:51:49

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC