HAC attachment B

FCC ID: OVF-K33BIC04

Test Report

Download: PDF
FCCID_1314367

                                                                                    FCC ID: OVF-K33BIC04


Validation E Field Probe SN2282, Dipole SN1015, 1900MHz
                                                                                            Date: 6/15/2010
Communication System: CW, Frequency: 1900 MHz, Duty Cycle: 1:1
Medium: Air,Medium parameters used: σ = 0 mho/m, εr = 1; ρ = 1000 kg/m3
Phantom: HAC Test Arch with AMCC,Phantom section: RF Section
DASY4 Configuration:
Probe: ER3DV6 - SN2282, ConvF(1, 1, 1), Calibrated: 8/14/2009
Sensor-Surface: (Fix Surface),
Electronics: DAE4 Sn527,Calibrated: 7/9/2009
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:
Room T = 21.8  1 deg C, Liquid T = 22.0  1 deg C

E Scan 1880 - measurement distance from the probe sensor center to CD1880 Dipole = 10mm/Hearing Aid
Compatibility Test (41x181x1): Measurement grid: dx=5mm, dy=5mm
Maximum value of peak Total field = 147.7 V/m
Probe Modulation Factor = 1.00
Device Reference Point: 0.000, 0.000, -6.30 mm
Reference Value = 164.0 V/m; Power Drift = -0.045 dB


                                         Peak E-field in V/m
                                          Grid 1   Grid 2   Grid 3
                                          126.3 M2 131.6 M2 129.4 M2
                                          Grid 4     Grid 5     Grid 6
                                          86.3 M3    88.7 M3    86.4 M3
                                          Grid 7   Grid 8   Grid 9
                                          135.5 M2 147.7 M2 145.8 M2




                                       0 dB = 147.7V/m




        HAC RF Validation Plots                          Page 1 of 2              Model: K33BIC-04


                                                                                    FCC ID: OVF-K33BIC04


Validation H Field Probe SN6123, Dipole SN1015, 1900MHz
                                                                                            Date: 6/13/2010
Communication System: CW, Frequency: 1900 MHz, Duty Cycle: 1:1
Medium: Air,Medium parameters used: σ = 0 mho/m, εr = 1; ρ = 1 kg/m3
Phantom: HAC Test Arch with AMCC,Phantom section: RF Section
DASY4 Configuration:
Probe: H3DV6 - SN6123, , Calibrated: 7/16/2009
Sensor-Surface: (Fix Surface),
Electronics: DAE4 Sn527,Calibrated: 7/9/2009
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:
Room T = 21.8 +/- 1 deg C, Liquid T = 22.0 +/- 1 deg C

H Scan - measurement distance from the probe sensor center to CD1880 Dipole = 10mm/Hearing Aid
Compatibility Test (41x181x1): Measurement grid: dx=5mm, dy=5mm
Maximum value of peak Total field = 0.453 A/m
Probe Modulation Factor = 1.00
Device Reference Point: 0.000, 0.000, -6.30 mm
Reference Value = 0.487 A/m; Power Drift = -0.073 dB


                                          Peak H-field in A/m
                                           Grid 1   Grid 2   Grid 3
                                           0.390 M2 0.412 M2 0.392 M2
                                           Grid 4   Grid 5   Grid 6
                                           0.430 M2 0.453 M2 0.437 M2
                                           Grid 7   Grid 8   Grid 9
                                           0.394 M2 0.418 M2 0.403 M2




                                      0 dB = 0.453A/m




        HAC RF Validation Plots                         Page 2 of 2               Model: K33BIC-04