HAC RF Validation Plots

FCC ID: OVF-K33BIC01

Test Report

Download: PDF
FCCID_1048548

                                                                                           FCC ID: OVF-K33BIC01


                                                                                                      Date: 12/14/2008


File Name: Validation H-Field, Ceramix PCS only_#1339, 1900Mhz 121408.da4


Communication System: CW; Frequency: 1900 MHz;Duty Cycle: 1:1
Medium parameters used: σ = 0 mho/m, εr = 1; ρ = 1 kg/m3
Phantom section: H Device Section


DASY4 Configuration:
- Probe: H3DV6 - SN6123; ; Calibrated: 8/18/2008
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn530; Calibrated: 4/15/2008
- Phantom: HAC Test Arch; Type: SD HAC P01 BA;
- Measurement SW: DASY4, V4.7 Build 71; Postprocessing SW: SEMCAD, V1.8 Build 184


H-Field Scan/Hearing Aid Compatibility Test (21x181x1): Measurement grid: dx=5mm, dy=5mm
Maximum value of peak Total field = 0.494 A/m
Probe Modulation Factor = 1.00
Device Reference Point: 0.000, 0.000, 353.7 mm
Reference Value = 0.541 A/m; Power Drift = 0.066 dB



                                                            Peak H-field in A/m


                                                             Grid 1     Grid 2    Grid 3
                                                             0.461 M2 0.467 M2 0.457 M2
                                                             Grid 4     Grid 5    Grid 6
                                                             0.489 M2 0.494 M2 0.484 M2
                                                             Grid 7     Grid 8    Grid 9
                                                             0.444 M2 0.448 M2 0.438 M2




                                      0 dB = 0.494A/m




System Validation Plots                                                 Page 1 of 2             Model: K33BIC-01


                                                                                            FCC ID: OVF-K33BIC01


                                                                                                       Date: 12/14/2008


File Name: Validation E-Field, Ceramix PCS only_#1339, 1900Mhz 121408.da4


Communication System: CW; Frequency: 1900 MHz;Duty Cycle: 1:1
Medium parameters used: σ = 0 mho/m, εr = 1; ρ = 1000 kg/m3
Phantom section: E Device Section


DASY4 Configuration:
- Probe: ER3DV6 - SN2341; ConvF(1, 1, 1); Calibrated: 4/17/2008
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn530; Calibrated: 4/15/2008
- Phantom: HAC Test Arch; Type: SD HAC P01 BA;
- Measurement SW: DASY4, V4.7 Build 71; Postprocessing SW: SEMCAD, V1.8 Build 184


E-Field Scan/Hearing Aid Compatibility Test (21x181x1): Measurement grid: dx=5mm, dy=5mm
Maximum value of peak Total field = 144.9 V/m
Probe Modulation Factor = 1.00
Device Reference Point: 0.000, 0.000, 353.7 mm
Reference Value = 72.9 V/m; Power Drift = -0.035 dB



                                                            Peak E-field in V/m


                                                             Grid 1     Grid 2    Grid 3
                                                             143.2 M2 144.9 M2 141.5 M2
                                                             Grid 4     Grid 5    Grid 6
                                                             89.5 M3    91.1 M3   90.4 M3
                                                             Grid 7     Grid 8    Grid 9
                                                             140.9 M2 142.2 M2 140.9 M2




                                       0 dB = 144.9V/m




System Validation Plots                                                 Page 2 of 2              Model: K33BIC-01



Document Created: 2008-12-17 14:51:23
Document Modified: 2008-12-17 14:51:23