RF Exposure Info

FCC ID: OU9BS-1507

RF Exposure Info

Download: PDF
FCCID_2879498

                                                         RF exposure Estimation

1.         Introduction
           The EUT is weigh scale, which contain Bluetooth function inside.

2.         Limit and Guidelines on Exposure to Electromagnetic Fields
           According to§15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this
           section shall be operated in a manner that ensure that the public is not exposed to radio
           frequency energy level in excess of the Commission’s guideline.

           According to KDB 447498 D01 Mobile Portable RF Exposure v05r01, no SAR required if power
           is lower than the flowing threshold:
           The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation
           distances ≤ 50 mm are determined by:
            [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]
            [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
                • f(GHz) is the RF channel transmit frequency in GHz
                • Power and distance are rounded to the nearest mW and mm before calculation25
                • The result is rounded to one decimal place for comparison
                • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below

           The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm
           and for transmission frequencies between 100 MHz and 6 GHz.

3.         Calculation method

           [(max. power of` channel, including tune-up tolerance, mW)/(min. test separation distance,
           mm)] ·[√f(GHz)] ≤ 3.0

           Conducted Power + tune up tolerance =-2.76dBm= 0.5mW
           Distance = 20 mm
           f = 2.440 GHz

           [0.5/20] * SQRT (2.440) =0.04
           0.04 ≤ 3.0
           Therefore, excluded from SAR testing.


TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch


Reviewed by:                                                                                   Prepared By:




Phoebe Hu/EMC Project Manager                                                       Felix Li/EMC Project Engineer
Date: 2016-01-07                                                                    Date: 2016-01-07


                                                            Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Culture Creative Park, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299



Document Created: 2016-01-07 16:19:31
Document Modified: 2016-01-07 16:19:31

© 2024 FCC.report