Simplified Operating Instruction, 340M OB Telemetry, 608-614MHz
GE Medical Systems Information Technologies                                                            4/9/01



340M OB Telemetry Simplified Operating Instructions

Overview:
The 340M OB Telemetry system is comprised of a transmitter and receiver to provide an RF link between
patient worn transducers and fetal monitor, allowing patient to freely move about while staff monitor fetal
heart rate and uterine contractions remotely.

The 341 Receiver is line powered from 120 VAC, and the 342 Transmitter is powered from (4) AA size
primary Alkaline cells. Expected life of the Alkaline cells in continuous use is roughly 16 Hrs.

There are two simulators used for exercising the transmitter. One is a production simulator (Model 325)
and the other is a radiation hardened simulator (built into a metal box). The 325 simulator will be used for
SAR testing and the radiation hardened will be used for other testing.

Other accessories are provided for their use in testing, if necessary.



Descriptions: (refer also to 340 Service manual, pages 3-2,3,4)

341 Receiver:

Front Panel:

         AC power switch                                         far right

         Toco/Iup mode change switch                             left

         Indicator lamps                                         center right

                  Signal strength indicator, green               top

                  Battery status, red                            center

                  AC mains, green                                bottom

Rear Panel:

         Power Entry Module                                      far left top

         Mark interconnect cable Jack                            far left bottom

         System Interconnect cable jack                          left bottom

         Ultrasound interconnect cable jack                      bottom center

         ECG interconnect cable jack                             bottom right

         UA interconnect cable jack                              bottom far right

         Equipotential ground jack                               top center



                                                                                                  Page 1 of 8


Simplified Operating Instruction, 340M OB Telemetry, 608-614MHz
GE Medical Systems Information Technologies                                                            4/9/01

         Antenna jack (RA female BNC)                           top center
                 Connect to ¼ wave stainless whip



342 Transmitter:

Front Panel:

         Ultrasound Transducer jack                             left

         ECG Transducer jack                                    center

         UA transducer jack                                     right


Rear Panel:

         Headphone jack                                         far left

         Remote mark transducer jack                            left

         Power switch                                           right

         Antenna jack (BNC)                                     far right
                 Connect to ¼ wave helical wound ant.


Bottom Panel:

         Battery access door



Radiation Hardened Simulator (for use at ITS, Boxborough):

This is an aluminum die-cast box containing (2) Alkaline ‘D’ cells providing power, and active circuitry
providing signal to the 5700 Ultrasound Transducers and UA Transducer plug.

Top:

         Power switch:

                  Must be in the ‘ON’ position to obtain simulated transducer signal. Turn ‘OFF’ when not
         needed to conserve battery.

         UA Ref pushbutton:

                  Forces UA simulated signal to a baseline level for physiologic signal drift testing. Not
used for RF testing.

         Adjustment Potentiometer:

                  Allows UA simulated signal to be offset from baseline level by adjustable amount. Not
used for RF testing.



                                                                                                  Page 2 of 8


Simplified Operating Instruction, 340M OB Telemetry, 608-614MHz
GE Medical Systems Information Technologies                                                         4/9/01




Side:

        (4) Gray Cables total

                 - Gray cable, no plug:

                          Not used

                 -Gray cable, 5700 Transducer at end, nothing beyond

                          Not used

                 -Gray cable, 5700 Transducer at end, mechanically face connected to slave 5700
transducer

                          This slave 5700 plug connects to Ultrasound input jack of the 342 transmitter.

                 -Gray cable, round 12 pin white connector at end

                          This plugs into the UA connector jack of the 342 Transmitter.



325 Maternal/Fetal Simulator (for use at ITS, Menlo Park, SAR):

Front Panel:

        FECG/MECG section:

                 RATE bpm:
                        Set to 120
                 QRS AMPLITUDE:
                        Set to 2000
                 CMR:
                        Set to BAL
                 MODE:
                        Set to FECG
                 QRS POLARITY:
                        Set to (+)

        ULTRASOUND/FMD section:

                 RATE bpm:
                        Set to 120
                 SIGNAL LEVEL:
                        Set to HIGH
                 MODE:
                        Set to US/FMD

        UA Section

                 Black Slide Switch:



                                                                                               Page 3 of 8


Simplified Operating Instruction, 340M OB Telemetry, 608-614MHz
GE Medical Systems Information Technologies                                                  4/9/01

                       Left position
                 LEVEL mmHg:
                       Set to 100
                 MODE:
                       Set to TOCO

        Bottom Center section

                 MANUAL ADJUSTMENT:
                      Full clockwise

                 PATTERN MEMORY:
                       ON

        Bottom Right

                 POWER indicator:
                       Glows green when AC power connected and rear panel switch depressed


Rear Panel:

        Power inlet:
                Connect IEC style power cord to 120 VAC

        Power button:
                Push on/ Push off style button. 325 must be powered on for testing.


Cable Harness, Front Panel:

        From Top Center (3) gray cables are connected from ‘CONNECT TO FETAL MONITOR’
connector.
               -Round white to UA input jack of 341 Transmitter

                 -Round Gray/Blue to ULTRASOUND input jack of 341 Transmitter

                 -Round dark gray to ECG input jack of 341 Transmitter



Procedure:

1)      Identify packed items.


        - 341M Telemetry Receiver
                - Line cord
                - System Interconnect cable #1563AAO
                - Mark interconnect cable #1397AAO
                - US interconnect cable #1399BAO
                - ECG interconnect cable #1375AAO
                - UA interconnect cable #1400AAO
                - Quarter wave stainless whip antenna (receiver)




                                                                                       Page 4 of 8


Simplified Operating Instruction, 340M OB Telemetry, 608-614MHz
GE Medical Systems Information Technologies                                                          4/9/01


        - 342M Telemetry Transmitter
                - Black Helical antenna (transmitter)
                - 3 sets of AA batteries
                - Remote Mark transducer #3919BAO
                - Softrans Cable #1336AAO
                - Softrans Intrauterine Pressure Catheter #2076AAO
                - Ultrasound Transducer #5700AAX
                - Toco transducer, #2264LAX
                - Headset #3316AAO
                - Qwik Connect Plus Legplate interface cable, #1590AAO

                 - Radiation Hardened Simulator, (no marking) Boxborough site

                 - Model 325 Simulator, Menlo Park site

2)      For tests involving fully modulated transmitter signals, interconnect system as shown:


                 Boxborough, MA:
                                                                                          Headset
Helical Ant.                                                                              (3316AAO)

                                                      (2) 5700 transducers
                            Ultrasound                         face to face
342M Transmitter                                                                        Boxborough:
                                                                                        RF Hardened
                                                                                        Simulator
(power switch on)
                            Uterine Activity                                            (Power switch on)


                            ECG


                                                                              1590AAO Legplate




stainless        AC Power
                                                                              Remote Mark
whip ant.
                                                                              pushbutton
                                                                              (3919BAO)
341M Receiver
                                               System Interconnect cable #1563AAO
(power switch on)
                                               Mark interconnect cable #1397AAO
(green signal strength LED
indicates transmitter active)                  US interconnect cable #1399BAO

                                               ECG interconnect cable #1375AAO

                                               UA interconnect cable #1400AAO



                                                                                                 Page 5 of 8


Simplified Operating Instruction, 340M OB Telemetry, 608-614MHz
GE Medical Systems Information Technologies                                                          4/9/01




3) Description of System as connected above.

        Input to modulate transmitter is derived from simulator. Can be monitored via headset.

        Uterine activity modulation derived from simulator.

        ECG modulation derived from simulator.

        Helical antenna radiates modulated RF to 341 Receiver.

        341 Receiver intercepts RF via ¼ wave stainless whip antenna.

        341 Receiver signal strength LED indicates transmitter active.




                                                                                                 Page 6 of 8


Simplified Operating Instruction, 340M OB Telemetry, 608-614MHz
GE Medical Systems Information Technologies                                                       4/9/01




Menlo Park Configuration:



                                                                                          Headset
                                                                                          (3316AAO)
Helical ant.

                                Ultrasound
    342M Transmitter                                                                    Menlo Park:
                                                                                        Model 325
                                                                                        Simulator
    (power switch on)
                                Uterine Activity                                        (Power switch on)


                                ECG




stainless           AC Power
                                                                                Remote Mark
whip                                                                            pushbutton
                                                                                (3919BAO)

    341M Receiver
                                             System Interconnect cable #1563AAO
    (power switch on)                                                                           Open (5)
                                             Mark interconnect cable #1397AAO
    (green signal strength LED
    indicates transmitter active)            US interconnect cable #1399BAO

                                             ECG interconnect cable #1375AAO

                                             UA interconnect cable #1400AAO




                                                                                              Page 7 of 8


Simplified Operating Instruction, 340M OB Telemetry, 608-614MHz
GE Medical Systems Information Technologies                                                          4/9/01




3) Description of System as connected above.

        Input to modulate transmitter is derived from simulator. Can be monitored via headset.

        Uterine activity modulation derived from simulator.

        ECG modulation derived from Model 325 simulator.

        Helical antenna radiates modulated RF to 341 Receiver.

        341 Receiver intercepts RF via ¼ wave stainless whip antenna.

        341 Receiver signal strength LED indicates transmitter active.