INSTALLATION

NOTES:        Pin spacing on all connectors is 2.54mm (0.1")
              All dimensions in millimetres


CONNECTION

Connection to the SR600 receiver is via PL1, PL2 and PL3 which plug directly into the
user's own equipment. The location of these connectors is shown in Figure 1 and detailed
in the following tables.




             PIN NAME         FUNCTION                REMARKS

              1      0V     0 volts           common ground
              2    RF I/P   RF input          50 ohms input
              3      0V     0 volts           common ground

                               Connector PL1 pin detail




             PIN NAME         FUNCTION                REMARKS

              1     +VIN    positive supply   +6.0V to +15.0V
              2      0V     0 volts           common ground

                               Connector PL2 pin detail


PIN   NAME     FUNCTION                                  REMARKS
 1    RSSI S meter output            0.5 - 2V signal strength indicator, 60dB range
 2    SQF    Squelch flag            open collector output, ON (low) = no signal
                                     250mV p-p ±20% into 10kS
                                     Note: The output audio is inverted with respect to
 3    AUDIO AF output
                                     the ST600 (or similar Wood & Douglas product)
                                     audio input.
 4    DATA   Data output             open collector, no pull-up
                                     Note: The data output is inverted with respect to
                                     the ST600 (or similar Wood & Douglas product)
                                     data input.
 5     +5V   +5 volt supply output   50mA maximum current drain
 6     0V    0 volts                 common ground
      RS232 serial programming       RS232 programming input
 7     I/P  input                    Note: inverted TTL level data can also be used. If
                                     not used, leave not connected, or connect to 0/V
 8     RB1
             parallel frequency      internal pull-up to +5V, active low
 9     RB2
             select
10     RB3

                            Connector PL3 pin detail


FREQUENCY PROGRAMMING

The SR600 has an internal memory which can store up to 128 RF channels (16 randomly
programmed and 112 sequentially programmed). The frequency and set-up information
is programmed into the unit by a synchronous PCM interface protocol.

The software supplied with the SR600 receiver is the STSRn00.exe program. The software
can be run on a PC with the serial port connected to PL3 of the SR600 receiver via a
suitable adaptor as shown in Figure 2. For the read-back function PL3 pin 10 of the
receiver must be connected to pin 2 of the PC serial port via a buffer circuit. A 1k pull-up
resistor to +5V must also be provided as shown.




                             Figure 2 Programming adaptor


RUNNING THE SOFTWARE

1.     Connect SR600 to a suitable supply and to the PC using the programming adaptor.

2.     Insert the STSRn00PRG disk into drive A and type:

              A:STSRn00 <return>

3.     The user is then prompted to enter the serial port number of his PC which is used
       to communicate with the SR600 receiver. Enter 1 or 2.

4.     Next there is a prompt to select STn00 or SRn00. Enter 2 for the SR600

5.     Next is the prompt to select freq. range:   1 : ST100 (125 - 180MHz)
                                                   2 : ST/SR500 (400 - 650MHz)
                                                   3 : ST/SR800 (800 - 880MHz)

After the software has successfully loaded the main menu screen is displayed as shown in
Figure 3. The screen shows the default settings which are entered at factory set-up. These
default settings will be displayed whenever the STSRn00 software is run.

Please note that mouse operation is not supported with this program.


FREQUENCY STORAGE

The internal PIC processor allows for both random allocated frequencies and sequential
channels. The program displays the 16 (as channel 0/ to 15) random channels on the main
screen. If a sequential table is used then these are stored in channels 16 to 127. These
cannot be displayed or printed out.

To simplify the situation, the first 16 channels of the sequential table can be copied to the
random channel by pressing the F2 button.

The first 8 channels (0 to 7) can be selected using the serial interface or the parallel
interface, as described later.


     STSRn00 Programmer v.1.0.02

     Chan   0    458.5    MHz <<   Comparison freq. 12.5 KHz
     Chan   1    458.5125 MHz      Ref. (TCXO) freq. 12. 8 MHz
     Chan   2    458.525 MHz       Parallel channel select
     Chan   3    458.5375 MHz
     Chan   4    458.55     MHz
     Chan   5    458.5625 MHz
     Chan   6    458.575 MHz       COMMANDS:
     Chan   7    458.5875 MHz
     Chan   8    458.6    MHz      F2        :copy Ch 16-31 to Ch 0-15
     Chan   9    458.6125 MHz      F3        :change comparison frequency
     Chan   10    458.625 MHz      F4        :set parallel ch. mode
     Chan   11   458.6375MHz       F5        :read from unit
     Chan   12    458.65 MHZ       F6        :program unit
     Chan   13   458.6625MHz       F7        :program serial channel
     Chan   14    458.675 MHz      F12       :QUIT
     Chan   15   458.6875MHz

     Start table 458.7    MHz
     Max. Freq. 458.95 MHz         Sequential frequencies, Chan. 16 to 127
     Table step 1 x 12.5 kHz




                                         Figure 3
NOTES:

1.       The reference (TXCO) frequency is not programmable.

2.       The readback function (F5) reads the current settings from the unit into the PC.

3.       Function F6 (program the unit) is only enabled after the read-back, (refer to Figure
         2). This function re-programs the unit connected.

4.       A value for each parameters has to be entered.

5.       Only channel 0 to 15 frequencies can be displayed by this software explicitly.

6.       Sequential channel table is displayed as start, step and stop frequencies.

Serial channel selection

The unit defaults to serial channel selection whenever the software is run. Selecting the F7
function key prompts the user to enter the new serial channel number which is then
displayed in ‘Serial channel selected’.


Parallel channel selection

To enable parallel channel selection mode press the F4 (Parallel channel mode) function
key, The screen then displays ‘parallel channel selected’.

Three inputs RB1, RB3 and RB3 applied via PL3 to pin 8, pin 9 and pin 10 respectively,
select the operating channel as shown in the following table.


                                 CHANNEL SELECTION
       PIN 10            PIN 9             PIN 8                  CHANNEL
        LOW              LOW               LOW                         7
        LOW              LOW               HIGH                        6
        LOW              HIGH              LOW                         5
        LOW              HIGH              HIGH                        4
        HIGH             LOW               LOW                         3
        HIGH             LOW               HIGH                        2
        HIGH             HIGH              LOW                         1
        HIGH             HIGH              HIGH                        0

The logic levels are :      LOW < 0.8V
                            HIGH > 2V or floating

Programming random channels

Random channels between 0 and 15 can be entered using the Up 8 and Down 9 arrow keys
and then entering the required operating frequency. The entered value must be an integer
multiple of comparison frequency otherwise an ‘invalid’ message is displayed.

Programming sequential channels

To generate a new frequency table the following parameter values must be entered:

       - start frequency
       - the table step as a multiple of comparison frequency.

The maximum frequency is calculated from the start table frequency and the table step..
Therefore if the calculation exceeds the maximum frequency then this parameter will be
increased automatically.

When the frequency table has been generated the user then selects F6 to program the unit,
assuming the unit has been read before.

The function key F2 can be used to copy the contents of channel 16-31 to channel 0 - 15 to
ease sequential programming.




Programming from customer equipment

In the event of a customer wishing to program the SR600 receiver from his own equipment
then the following data sequence must be used allowing 5ms between the characters in the
data stream:

      1200 baud, RS232 levels, 1 start bit - 8 bit data - no parity - 1 stop bit

      40 (decimal 64) synchronising code
      7 bit channel 0 - 127 (bit 7 = 0)
      95 (decimal 149) confirmation byte


RANGE INFORMATION

The following table gives an indication of the typical ranges to be expected between a
transmitter and receiver that have simple end-fed dipole antennas.

The following assumptions have been made in the calculations:

      line-of-sight between antennas
      0dB gain for the transmitter and receiver antennas
      0dB loss for connectors and cables between the antenna and the radio connector
      20dB fade and environmental margin
      -100dBm received signal strength, allowing for digital and analogue signals

                               Range versus TX power

      Frequency (MHz)        Power (mW)       Power (dBm)       Range        Miles
                                                                 (km)
             600                 1mW                 0            0.4         0.3
             600                10mW                10            1.3         0.8
             600                25mW                14            2.0         1.2
             600                100mW               20            4.0         2.5
             600                500mW               27            8.9         5.5


TECHNICAL SPECIFICATION

Frequency range                :       580 - 625MHz
Switching bandwidth            :       8MHz
Frequency stability            :       +/-2.5ppm
Number of RF channels          :       up to 128 (16 randomly programmed, 112 sequential),
                                       serial select/reprogram, 1200 baud RS232 or
                                       1 of 8 parallel select (10 pin option)
Channel switching delay        :       <50mS across switching bandwidth
Channel spacing                :       25kHz
Modulation type                :       F3D
Spurious emissions
(conducted & radiated)         :       in accordance with ETS/CEPT specifications
Supply voltage                 :       6-12 DC, -ve earth
Supply current at 7.2V         :       <40mA
Interface connections          :       2 + 10 pin 0.1" header
RF connection                  :       3 pin 0.1" header
Operating temperature          :       -30oC to +55oC
Storage temperature            :       -30oC to +70oC
Weight                         :       35g
Size                           :       60 x 39 x 15mm (2.36 x 1.53 x 0.59 inches)
Type approval                  :
Sensitivity                    :       <-117 dBm for 12dB SINAD (25 kHz)
                                       (Measured with a flat audio response)
Image/spurii                   :       >60dB
Intermodulation response
rejection                      :     >60dB
Blocking                       :     >75dB
Intermediate frequencies       :     45 MHz and 455kHz
Adjacent chan. selectivity     :     >60dB for 12.5kHz channel spacing
                                     >70dB for 25kHz channel spacing
Audio response                 :     9Hz to 6kHz at -3dB (25kHz channels)
Recovered audio level          :     >250mV p-p (±20%) into 10kS
Squelch type       :           Noise operated open collector output
General facilities             :     RSSI output (0.5 to +2V nominal)
                                     +5V output
                                     Independent data output




Wood and Douglas Ltd
Lattice House, Baughurst Road, Tadley, Hampshire RG26 5LP                           1892 1274
Tel: +44(0) 118 981 1444. Fax: +44(0) 118 981 1567                         1.0/September 2000



Document Created: 2019-07-13 00:40:57
Document Modified: 2019-07-13 00:40:57

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC