Report_FCC_MPE

FCC ID: OU5-MAC7

RF Exposure Info

Download: PDF
FCCID_4164059

GE Medical Systems Information
Technologies, Inc.
MPE ASSESSMENT REPORT
Report Type:
FCC MPE assessment report


Model:
MAC 7


REPORT NUMBER:
190100631SHA-004


ISSUE DATE:
January 7, 2019



DOCUMENT CONTROL NUMBER:
TTRFFCCMPE-01_V1 © 2018 Intertek


                                                                                                                  Intertek Testing Services Shanghai
                                                                                                        Building No.86, 1198 Qinzhou Road (North)
 In tert@ k                                                                                                           CacheJing Development Zone
                                                                                                                            Shanghai 200233, China
 Total Quality. Assured.
                                                                                                                       Telephone: 86 21 6127 8200
 TEST REPORT                                                                                                                     www.intertek.com

                                                                                                                    Report no.: 190100631SHA—004



  Applicant:                              GE Medical Systems Information Technologies, Inc.
                                          8200W, Tower Ave, Milwaukee, WI 53223 USA

  Manufacturer:                           GE Medical Systems Information Technologies, Inc.
                                          8200W, Tower Ave, Milwaukee, WI 53223 USA

  Factory 1:                              GE Medical Systems (China)Co., Ltd
                                          No.19 Changjiang Road, Wuxi National Hi—Tech Development Zone,
                                          Jiangsu, 214028, China

 Factory 2:                               GE Medical Systems Information Technologies
                                          CRITIKON DE MEXICO S. de R.L. de CV. Calle Valle del Cedro 1551—
                                          Juarez— 32575 CHIHUAKHUA—MEX

 FCC ID:                                  OUS—MAC7




  KDB447498 DO1 General RF Exposure Guidance vO6
  FCC Part2.1091, FCC Part2.1093 FCC Part1.1307(b)




   M/"‘/\?é
Project Engineer                                                            Reviewer
Nemo Li                                                                     Daniel Zhao




This report is for the exclusive use of Intertek‘s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek‘s
responsibility and fiability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the
Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to
permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or
advertisementof the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this
reportare relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been
under an Intertek certification program.

TTRFFCCMPE—O01_V1© 2018 Intertek                                    Page 2 of 8


                                                                             Report No.: 190100631SHA-004



TEST REPORT


                                            Revision History

      Report No.                  Version              Description                      Issued Date
  190100631SHA-004                Rev. 01          Initial issue of report              January 7, 2019




TTRFFCCMPE-01_V1© 2018 Intertek                Page 3 of 8


                                                                          Report No.: 190100631SHA-004



TEST REPORT


1 GENERAL INFORMATION

1.1 Description of Equipment Under Test (EUT)

 Product name:                    Resting ECG Analysis System
 Type/Model:                      MAC 7
 Description of EUT:              EUT is a product with WiFi function and has only one model.
 Rating:                          100-240V AC, 50/60Hz
 EUT type:                            Table top    Floor standing
 Software Version:                /
 Hardware Version:                /
 Sample received date:            December 4, 2018
 Date of test:                    December 4, 2018 ~ December 26, 2019


1.2 Technical Specification

 Frequency Range:                 2400MHz ~ 2483.5MHz
                                  IEEE 802.11b, IEEE 802.11g, IEEE 802.11n(HT20), IEEE
 Support Standards:               802.11n(HT40)
                                  IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK)
                                  IEEE 802.11g: OFDM (64-QAM, 16-QAM, QPSK, BPSK)
                                  IEEE 802.11n(HT20): OFDM (64-QAM, 16-QAM, QPSK, BPSK)
 Type of Modulation:              IEEE 802.11n(HT40): OFDM (64-QAM, 16-QAM, QPSK, BPSK)
                                  11 Channels for 802.11b, 802.11g and 802.11n(HT20)
 Channel Number:                  7 Channels for 802.11n(HT40)
 Channel Separation:              5 MHz

                                  5150 ~ 5250MHz
                                  5250 ~ 5350MHz
                                  5470 ~ 5725MHz
 Frequency Range:                 5725 ~ 5850MHz
 Support Standards:               802.11a, 802.11n/ac(HT20), 802.11n/ac(HT40)
 Type of Modulation:              OFDM (BPSK, QPSK, 16QAM, 64QAM)
                                  For 5150 ~ 5250MHz band: Channel 36 - 48
                                  For 5250 ~ 5350MHz Band: Channel 52 - 64
                                  For 5470 ~ 5725MHz Band: Channel 100 - 140
 Channel Number:                  For 5725 ~ 5850MHz band: Channel 149 - 165



TTRFFCCMPE-01_V1© 2018 Intertek                    Page 4 of 8


                                                                           Report No.: 190100631SHA-004



TEST REPORT


1.3 Description of Test Facility

 Name:                   Intertek Testing Services Shanghai

 Address:                Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China

 Telephone:              86 21 61278200

 Telefax:                86 21 54262353



 The test facility is    CNAS Accreditation Lab
 recognized,             Registration No. CNAS L0139
 certified, or
                         FCC Accredited Lab
 accredited by these
                         Designation Number: CN1175
 organizations:
                         IC Registration Lab
                         Registration code No.: 2042B-1
                         VCCI Registration Lab
                         Registration No.: R-4243, G-845, C-4723, T-2252
                         A2LA Accreditation Lab
                         Certificate Number: 3309.02




TTRFFCCMPE-01_V1© 2018 Intertek                    Page 5 of 8


                                                                       Report No.: 190100631SHA-004



TEST REPORT


2 MPE Assessment
      Test result:          Pass

2.1 MPE Assessment Limit

Mobile device exposure for standalone operations:
Frequency range E-field strength H-field strength            B-field          Equivalent plane wave
                        (V/m)             (A/m)               (uT)               power density
                                                                                   Seq (W/m2)
      0-1 Hz                      -         3,2 × 104        4 × 104                     -
      1-8 Hz                   10 000      3,2 × 104/f2    4 × 104/f2                    -
     8-25 Hz                   10 000        4 000/f         5 000/f                     -
  0,025-0,8 kHz                 250/f           4/f            5/f                       -
    0,8-3 kHz                   250/f            5            6,25                       -
    3-150 kHz                    87              5            6,25                       -
   0,15-1 MHz                    87           0,73/f         0,92/f                      -
    1-10 MHz                   87/f1/2        0,73/f         0,92/f                      -
   10-400 MHz                    28           0,073           0,092                     2
 400-2 000 MHz                1,375 f1/2   0,0037 f1/2     0,0046 f1/2                f/200
    2-300 GHz                    61            0,16           0,20                      10


Mobile device exposure for simultaneous transmission operations: the sum of the MPE ratios
for all simultaneously transmitting antennas incorporated in a host device is ≤ 1.0




TTRFFCCMPE-01_V1© 2018 Intertek              Page 6 of 8


                                                                 Report No.: 190100631SHA-004



TEST REPORT

2.2 Assessment Results

Power density (S) is calculated according to the formula:
S = P / (4πR² )
Where S = power density in mW/cm²
         P = Radiated transmit power in mW
         G = numeric gain of transmit antenna
         R = distance (cm)

As we can see from the test report 190100631SHA-001 and 190100631SHA-002:
The maximum radiated power = 20.41dBm = 109.9 mW;
Here R is chosen to be 20cm,

S = P / (4πR²) = 109.9 / (4 * 3.14 * 20 * 20) = 0.022 mW/cm² < 1 mW/cm²




TTRFFCCMPE-01_V1© 2018 Intertek             Page 7 of 8


                                                                  Report No.: 190100631SHA-004



TEST REPORT

Appendix I

Definition below must be outlined in the User Manual:

To satisfy FCC RF exposure requirements, a separation distance of 20 cm or more should be
maintained between the antenna of this device and persons during device operation.
To ensure compliance, operations at closer than this distance is not recommended.