Test Report

FCC ID: OSLOKA-211W

Test Report

Download: PDF
FCCID_4450420

 Report Number:             F690501/RF—RTLO14157—1                                            Page:      1     of      28




                              TEST REPORT
                                                            of

                                    FCC Part 15 Subpart C §15.209

                                          FCC ID: OSLOKA¥—211W


Equipment Under Test                     UNIT ASSY — WIRELESS CHARGING
Model Name                          : OKA—211W
Variant Model Name                  : OKA—213W
Applicant                           : Omron Automotive Electronics Korea Co., Ltd.
Manufacturer                        : Omron Automotive Electronics Korea Co., Ltd.
Date of Receipt                     : 2019.05.07
Date of Test(s)                     : 2019.07.01 ~2019.07.29
Date of Issue                       : 2019.08.19


In the configuration tested, the EUT complied with the standards specified above.




  Tested By:                                                        Date:                      2019.08.19


                                 Murphy Kim


   Technical                         z"                             Date:                      2019.08.19
   Manager:                            zi


                                Jungmin Yang




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory)    4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807   hftp/www.sgsgroup.kr
RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 /Fax. +82 31 427 2370           A4(210 mm x 297 mm)


Report Number:              F690501/RE—RTLO14157—1                                         Page:       2       of        28




                                             Contents
 1. G@NBAL INfOFMAtION ——————————————onn n on ooeoenoonnnonnnoennonnnnnn en enc nnc e>                               3

 2. Field Strength of Fundamental and Spurious Emission —                                                            7

 3. 20 4B BANUWIGtAoooococccccnnommcnnncnnnccnnccnnncnnncnenccenccces                                               26




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


Report Number:              F690501/RE—RTLO14157—1                                           Page:       3       of      28


1. General Information

1.1. Testing Laboratory
SGS Korea Co., Ltd. (Gunpo Laboratory)
     — 10—2, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807
     — 4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807
     — Designation number: KRO150
All SGS services are rendered in accordance with the applicable SGS conditions of service available on
request and accessible at http://www.sqs.com/en/Terms—and—Conditions.aspx.
Phone No.              :    +82 31 688 0901
Fax No.                :    +82 31 688 0921

1.2. Details of Applicant
Applicant             :     Omron Automotive Electronics Korea Co., Ltd.
Address               :     790—12, Bogaewonsam—ro, Bogae—myeon, Anseong—si, Gyeonggi—do, South Korea,
                            17507
Contact Person        _:    Nam, Sang—ll
Phone No.             1     +822 850 5789

1.3. Details of Manufacturer
Company               :     Same as applicant
Address               :     Same as applicant

1.4. Description of EUT

 Kind of Product                     UNIT ASSY — WIRELESS CHARGING

 Model Name                          OKA—211W

 Variant Model Name                  OKA—213W

 Power Supply                        DC 12.0 V

 Frequency Range                     112 k

 Antenna Type                        Inductive loop coil antenna


1.5. Declaration by the Manufacturer
— The EUT has 3 loop coil antennas with one amplifier, and only one antenna can transmit at once.




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)     4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                          Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


 Report Number:              F690501/RE—RTLO14157—1                                          Page:          4     of     28


1.6. Test Equipment List
     a                                                                                             Cal.
  Equipment        Manufacturer              Model                  S/N           Cal. Date      Interval         Cal. Due

   Spectrum
   Analyzer
                        nas                  FSvao                103210        Dec. 05, 2018    Annual         Dec. 05, 2019
    Signal
  Generator             R&S               SMBV100A                259067        Jun. 10, 2019    Annual         Jun. 10, 2020


Test Receiver           R&S                  ESU26                100109        Jan. 31, 2019    Annual         Jan. 31, 2020

   Amplifier            H.P.                 8447F             2944403909       Aug. 07, 2018    Annual         Aug. 07, 2019

                   Schwarzbeck                                                                    ols
 Loop Antenna     Mess—Elektronik          FMZB 1519             1519—039       Aug. 23, 2017    Biennial       Aug. 23, 2019

 Bilog Antenna     Schwarzbeck
                  Mess—Elektronik
                                           vuLBores                on26         Mar. 26, 2018    Biennial       Mar. 26, 2020
                   Innco systems                               MA4640/536/3
Antenna Master         GmbH              MA4640—XP—ET            83305161           N.C.R.            N/A          NC.R.

  Turn Tabie       InncoGmbH
                         systems           Ds 1200 s                NA              N.C.R.            N/A          N.CR.
                   Innco systems         CONTROLLER            ©O3000/963/3
   Controller          GmbH               C03000—4P             83305161            N.C.R.            N/A          NC.R.

   Anechoic                  .              Lx W x H
   Chamber        SY Corporation     (9.6 m x 6.4 m x 6.6 m)        NA              N.C.R.            N/A          NC.R.

Coaxial Cable       SUCOFLEX                104 (3 m)           MY3258414       Jul. 04, 2019     S;’E;I        Jan. 04, 2020

Coaxial Cable       SUCOFLEX               104 (10 m)           MY3145814       Jul. 04, 2019     S::S;I        Jan. 04, 2020


> Support Equipment
          Description                        Manufacturer                       Model                       FCC ID

   Samsung Mobile Phone             Samsung Electronies Co., Ltd.            SM—G955N                 ASLSMG9S5N


1.7. Sample Calculation
Where relevant, the following sample calculation is provided:
Field strengthlevel (dBa¥/m) = Measured level (dBzV) + Antenna factor (dB) + Cable loss (dB)




mmz
 The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
 the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
 withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)    4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807    Affp:s/fivwwsasoroup kr

 RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370           A4(210 mm x 297 mm)


 Report Number:              F690501/RE—RTLO14157—1                                         Page:       5       of      28


1.8. Worst Case of Test Configurations

             EUT Configuration                                                 Description


               Charging Mode                                                  1 % of battery
              With Client Device                                                o
             (Model: SM—G95S5N,                                              50 % of battery
            FCC ID: ASLSMGISS5N)                                             99 % of battery


Note;

EUT was investigated with client device under normal charging condition as above then worst value was only
reported.

1.9. Summary of Test Result
The EUT has been tested according to the following specification:


                                   APPLIED STANDARD: FCC Part 15 Subpart C

        Section                                          Test Item                                           Result

         15.209                       Radiated emission, Spurious Emission and
                                             Field Strength of Fundamental                                  Complied

         2.1049                                     20 dB Bandwidth                                         Complied


1.10. Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the apparatus:

                      Parameter                                                      Uncertainty

                 Occupied Bandwidth                                                   + 9.66 h

        Radiated Disturbance, 9 ki to 30 Ift                                          £ 3.59 dB

         Radiated Disturbance, below 1 6t                                             £ 5.88 dB

Uncertainty figures are valid to a confidence level of 95 %.




mmz
 The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
 the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
 withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)    4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

 RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


Report Number:              F690501/RE—RTLO14157—1                                         Page:           6      of       28


1.11. Test Report Revision

 Revision             Report Number                Date of Issue                           Description

     0           F690501/RF—RTLO14157                2019.08.01                                Initial

     1          F690501/RF—RTLO14157—1               2019.08.19           Revised the spurious emission test result


1.12. Information of Variant Model

              Model Name                                                      Description

    Basic Model              OKA—211 W         — Basic model

   Variant Model             OKA—213W          — Same to basic madel except the cover case.




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807       hitp:/worw.sascroup ks
RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370             A4(210 mm x 297 mm)


 Report Number:             F690501/RE—RTLO14157—1                                            Page:         7     of      28


2. Field Strength of Fundamental and Spurious Emission
2.1. Test Setup
The diagram below shows the test setup that is utilized to make the measurements for emission from 9. i#
to 30 M.


                                                 Tumn Table



                                     EUT
                            fi                                     f                                         Coaxial
           Power Cable                                        0.8 m                               (€——Cable

                                               |
                                              Pm
                                                                                                      Ground Plane
                         Power

                                                                                         EMI Receiver


The diagram below shows the test setup that is utilized to make the measurements for emission from 30 M
to 1 (z.




                                                                                                  im — 4m
                                                 Turn Table                                          l


                                 ___| Eut            l
                                                              a—3 —»




                                                                                                        Coaxial

            Power Cable                                   o8                                            Cable




                                                                                                  Ground Plane
                          Power
                                                                                      EMI F




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)      4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                           Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


 Report Number:             F690501/RE—RTLO14157—1                                         Page:       8       of      28


2.2. Limit

2.2.1. Radiated emission limits, general requirements

According to §15.209(a), except as provided elsewhere in this subpart, the emissions from an intentional
radiator shall not exceed the field strength levels specified in the following table:

             Frequency                             Field Strength                        Measurement Distance
                (Mz)                            {microvolts/meter)                                 {meter)
            0.009—0.490                               2 400/F(kz)                                    300
            0.490—1.705                              24 00O0/F(Kit)                                   30
             1.705—30.0                                   30                                          30
                30—88                                    100**                                        3
               88—216                                    150**                                        3
              216—960                                    200**                                        3
             Above 960                                    500                                         3
** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this
section shall not be located in the frequency bands 54—72 Mk, 76—88 Mt, 174—216 k or 470—806 z. however,
operation within these frequency bands is permitted under other sections of this part, eg., §§15.231 and
15.241.




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


 Report Number:             F690501/RE—RTLO14157—1                                         Page:       9       of      28


2.3. Test Procedures

Radiated emissions from the EUT were measured according to the dictates of ANSI €63.10:2013.


2.3.1. Test Procedures for emission from 9 k to 30 Mz

a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter anechoic
   chamber test site. The table was rotated 360 degrees to determine the position of the highest radiation.
b. Then antenna is a loop antenna is fixed at one meter above the ground to determine the maximum value
   of the field strength. Both parallel and perpendicular of the antenna are set to make the measurement.
c. For each suspected emission, the EUT was arranged to its worst case and then the table was turned from
   0 degrees to 360 degrees to find the maximum reading.
d. The test—receiver system was set to Quasi Peak and Average Detect Function and Specified Bandwidth
  with Maximum Hold Mode.

2.3.2. Test Procedures for emission from 30 M to 1 000 Mz

a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter anechoic
   chamber test site. The table was rotated 360 degrees to determine the position of the highest radiation.
b. During performing radiated emission below 1 (, the EUT was set 3 meters away from the interference
   receiving antenna, which was mounted on the top of a variable—height antenna tower. During performing
   radiated emission above 1. (%, the EUT was set 3 meter away from the interference—receiving antenna.
c. The antenna is a broadband antenna, and its height is varied from one meter to four meters above the
   ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of
  the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
   heights from 1 meter to 4 meters and the table was turned from 0 degrees to 360 degrees to find the
   maximum reading.
e. The test—receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold
  Mode.




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


 Report Number:              F690501/RE—RTLO14157—1                                                  Page:   10        of        28


2.4. Field Strength of Fundamental Test Result

Ambient temperature              :10    (2341) °C
Relative humidity                :0     47      % R.H.


The following table shows the highest levels of radiated emissions on both polarizations of horizontal and
vertical.

Test Condition: Operating Mode with Client Device (1 % Battery Status of Client Device)

                i       feat                                  Correction                                               Imi
            Radiated Emissions                    Ant.          Factors                     Total                     Limit
                        i                                                          Actual           Actual    Limit                i
  Frequency       Reading              Detect               Ant.      Cable                                                 Margin

      w             ceam               mode °* com ©                              Tom mooom stovom                             _
Ant. 1

    0.112          70.62        Average            H       19.69       0.05        90.36            10.36     26.62           16.26

Ant. 2

    0.112          68.80        Average            H       19.69       0.05        88.54            8.54      26.62           18.08

Ant. 3

    0.112          69.10        Average            H       19.69       0.05        88.84            8.84      26.62           17.78

Remark;

1. According to §15.31(f)(2),
  — 300 m Result (dBaV¥/m) = 3 m Result (dBaV/m) — 40log (300/3) (dBa¥/m).
2. According to field strength table of general requirement in §15.209(a), field strength limits below 1.705 t
  were calculated as below.
  —9 kk to 490 kk: 20 log (2 400 / F (K)) at 300 m (dBa¥/m)
  — 490 kk to 1.705 Mk: 20log (24 000/F (kk)) at 30 m (dBa¥/m)
3. According to §15.209(d), the measurements were tested by using Quasi peak detector except for the
   frequency bands 9—90 kit, 110—490 it and above 1 & in these three bands on measurements employing
   an average detector.
4. The limit above was calculated based on table of §15.209(a).




mmz
 The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
 the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
 withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
 SGS Korea Co., Lid. (Gunpo Laboratory)         4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807    Affp:s/fivwwsasoroup kr

 RTT5041—19(2019.04.24)(1)                               Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


 Report Number:          F690501/RF—RTLO14157—1                                                  Page:    11                28


— Test plots

Test Condition: Operating Mode with Client Device (1 % Battery Status of Client Device)

Ant. 1

                            &                         m        ow o
                                  FREQUENCY                112.4984         kHz
                                  xo         7o.é5    aBav (7o.7      i12.4984 knz)
                                  cex        7o.60    aBav (7o.6      112.4984 knz)
                                  ay         7o.62    aBav (7o.6      112.4984 knz)




                            oae: an.omcoom. sereine


Ant. 2

                            &                         m        ow io
                                  FREQUENCY                112.4984         kHz
                                  xo         ss.92.   aBpv (68.9      112.4984 knz)
                                  cex        se.76     aBpv (e8.8     112.4984 knz)
                                  ay         ss.79     aBpv (68.8     112.4984 knz)




                            oanes ancomcaomm accons




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)        4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807   hitp:/worw.sascroup ks
RTT5041—19(2019.04.24)(1)                              Tel. +82 31 428 5700 / Fax. +82 31 427 2370        A4(210 mm x 297 mm)


 Report Number:          F690501/RF—RTLO14157—1                                                       Page:   12                28


Ant. 3

                            &                           m ne en     How t "
                                   FREQUENCY                      112.4984       kHz
                                   xo          so.11.      dBav (69.1      112.4984 knz)
                                   cex         e9.05        dBav (69.1     112.4984 knz)
                                   ay          9.07        aBav (69.1      i12.4984 knz)




                            oares an.ovi omm acconces




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)          4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807     hitp:/worw.sascroup ks
RTT5041—19(2019.04.24)(1)                                   Tel. +82 31 428 5700 / Fax. +82 31 427 2370       A4(210 mm x 297 mm)


 Report Number:              F690501/RE—RTLO14157—1                                                             Page:     13          of           28


2.5. Spurious Emission Test Result
Ambient temperature              :     (2341) °C
Relative humidity                :0    47      % R.H.

The following table shows the highest levels of radiated emissions on both polarizations of horizontal and
vertical.

Test Condition: Operating Mode with Client Device (1 % Battery Status of Client Device)

Ant. 1

Below 30 M
                i       feat                                     Correction                                                           Imi
            Radiated Emissions                   Ant.              Factors                         Total                             Limit
                                                                                         Actual             Actual         Limit
  Frequency       Reading             Detect     Pol:           AF         CL           (dB(;;/:n)         (dBa¥im)      (dBa¥/im)          Margin
      (G)           (cBav)            Mode              *     (dBim)       (dB)           at 3 m
                                                                                                           at 300 m      at 300 m             (dB)
                                                                                                           or 30 m       or 30 m
    0.019           25.60      Average            H           19.97       0.01            45.58                ~34.42     42.03              76.45

    0.049           25.80      Average            H           19.77       0.02            45.59            ~34.41         33.80              68.21

    0.084           11.00      Average            H           19.72       0.03            30.75            ~49.25         29.12              78.37

    0.339           29.70      Average            H           19.60       0.22            49.52            ~30.48         17.00              47.48
    Above            Not                .          .             .          .               .                    .              .              .
    1.000         detected

Above 30 Mz
            Radiated Emissions                   Ant             Correction Factors                   Total                         Limit
 Frequency        Reading             Detect     Pol                 AF         AMP + CL             Actual              Limit              Margin
     (Of)          (dBay)             Mode         2            (dB/m)             (dB)              (dBa¥/im)          (dBy¥t/m)             (dB)
   264.94          35.40              Peak        H             18.50             2518                28.72              46.00               17.28

   275.77          34.20              Peak        H             18.72             <25.27              27.65              46.00               18.35

   307.50          33.20              Peak        H             19.25             25.04               27.41              46.00               18.59

   365.30          32.30              Peak        H             20.31             24.79               27.82              46.00               18.18
   Above            Not                 .          .                 .              .                      .                .                  .
   400.00         detected




mmz
 The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
 the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
 withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
 SGS Korea Co., Lid. (Gunpo Laboratory)        4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807                 Affp:s/fivwwsasoroup kr

 RTT5041—19(2019.04.24)(1)                                  Tel. +82 31 428 5700 / Fax. +82 31 427 2370                   A4(210 mm x 297 mm)


 Report Number:             F690501/RE—RTLO14157—1                                                       Page:    14          of           28


Ant. 2

Below 30 M
           Radiated Emissions              Ant.             Correction                       Total                           Limit
                                                              Factors
                                                                                    Actual             Actual       Limit
 Frequency       Reading        Detect     Pol:            AF         CL           (dBa¥im)          (dBa¥/m)     (dBa¥/im)         Margin
    (Mz)          (cBa¥)        Mode               *     (dB/m)       (dB)           t3              at 300 m     at 300 m            (dB)
                                                                                    atom              or 30 m      or 30 m
   0.018           24.60      Average        H           19.98       0.01            44.59           ~35.41        42.50             77.91

   0.067           17.00      Average        H           19.75       0.03            36.78           ~43.22        31.08             74.30

   0.084           13.40      Average        H           19.72       0.03            38.15           ~46.85        29.12             75.97

   0.338           35.50      Average        H           19.60       0.22            55.92           —24.68        17.03             41.71

   0.564           27.70        %Zii'        HO|         1g61        o.ss            47.66               7.66      s2ss              24.92
   Above            Not            .         .              .          .               .                  .             .              .
   1.000         detected

Above 30 Mz
           Radiated Emissions              Ant              Correction Factors                  Total                       Limit
 Frequency       Reading        Detect     Pol                  AF         AMP + CL            Actual             Limit             Margin
    (6H)          (cBa)         Mode               "       (cB/m)             (dB)            (cBaW/im)          (cBa¥im)             (dB)
  109.99          34.90         Peak        H              16.50             —25.36            26.04              43.50              17.46

  128.98          37.40         Peak        V              14.60             —25.38            26.62              43.50              16.88

   50.98          32.30         Peak        H              20.11             —26.38            26.03              40.00              13.97

  226.43          34.40         Peak        H              17.63             <25.24            26.79              46.00              19.21

  283.25          37.70         Peak        H              18.87             —25.26            31.31              46.00              14.69

  352.04          34.20         Peak        H              20.98             —25.08            30.10              46.00              15.90
   Above           Not             .         .                  .              .                     .              .                  .
  400.00         detected




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807                hitp:/worw.sascroup ks
RTT5041—19(2019.04.24)(1)                              Tel. +82 31 428 5700 / Fax. +82 31 427 2370                A4(210 mm x 297 mm)


 Report Number:             F690501/RE—RTLO14157—1                                                Page:    15          of         28


Ant. 3

Below 30 M
         Radiated Emissions                Ant.            Correction                   Total                       Limit
                                                             Factors
                                                                                Actual            Actual     Limit
 Frequency       Reading        Detect     Pol:           AF         CL        (dBa¥im)         (dBa¥/m)   (dBa¥/im)        Margin
    (Mz)          (dBaw)        Mode              *     (dB/m)       (dB)        t3             at 300 m   at 300 m           (dB)
                                                                                atom             or 30 m    or 30 m
   0.020          23.10       Average        H          19.95       0.01        43.06           ~36.94      41.58           78.52

   0.070           14.90      Average        H          19.74       0.03        34.67           ~45.33      30.70           76.03

   0.098           15.00        %Zzi'        H          19.70       o.04        s474            —4s2e       2778            79.04
   0.337          29.80       Average        H          19.60       0.22        49.62           —30.38      17.05           47.43
   Above            Not            .         .             .          .            .                .           .             .
    1.000        detected




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807         Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                             Tel. +82 31 428 5700 / Fax. +82 31 427 2370          A4(210 mm x 297 mm)


 Report Number:             F690501/RE—RTLO14157—1                                            Page:    16        of          28


Above 30 Mz
           Radiated Emissions              Ant         Correction Factors              Total                   Limit
 Frequency       Reading        Detect     Pol          AF          AMP + CL           Actual          Limit           Margin
    (6k)          (dBav)        Mode         O‘       (dB/m)            (dB)          (dBa¥/im)       (dBa¥im)          (dB)

  226.51          34.10         Peak        H         17.63           25.24            26.49           46.00           19.51

  252.90          33.80         Peak        H         18.32           25.24            26.88           46.00           19.12

  277.03          34.50         Peak        H         18.74           25.29            27.95           46.00           18.05

  305.80          33.40         Peak        H         19.22           —25.08           27.54           46.00           18.46

  352.92          32.90         Peak        H         20.96           25.07            28.79           46.00           17.21
   Above           Not             .         .           .                .               .              .               .
  400.00         detected

Remark;

1. According to §15.31(f)(2)
  — 300 m Result (dBa¥/m) = 3 m Result (dBaV¥/m) — 4010g(300/3) (dBeV/m)
  — 30 m Result (dBaV/m) = 3 m Result (dBa¥/m) — 4010g(30/3) (dBe¥/m)
2. According to field strength table of general requirement in §15.209 (a), field strength limits below 1.705 M
   were calculated as below.
  —9 kk to 490 kk: 20log (2 400 / F (ki)) at 800 m (dBaV/m)
  — 490 k to 1.705 Mk: 20log (24.000 / F (K)) at 30 m (dBa¥/m)
3. According to §15.209(d), the measurements were tested by using Quasi peak detector except for the
   frequency bands 9—90 k, 110—490 ki and above 1 (z in these three bands on measurements employing an
   average detector.
4. The limit above was calculated based on table of §15.209(a).




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807     Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                         Tel. +82 31 428 5700 / Fax. +82 31 427 2370          A4(210 mm x 297 mm)


 Report Number:              F690501/RE—RTLO14157—1                                              Page:     17        of      28


Test Condition: Operating Mode with Client Device (1 % Battery Status of Client Device)

— Test plots

Ant. 1

Below 30 M

                            &                                  us 5
                                   FREQUENCY                 18.7244        kHz
                                   xo         s0.98    aBpv (32.5      i8.7244 kiz)        ,
                                   cex        26.06    deny (26.5      i8.7244 kiz)        ,
                                   ay         24.02.   deay (25.6      i8.7244 kiz)        |




                            oaes an.omcoomm. aecanos




                            &                                  us 5
                                   FREQUENCY                 49.2003        kHz
                                   xo         a7.se    deay (29.8      49.2003 kiz)        ,
                                   cex        a5.57    deay (25.8      49.2003 kiz)        ,
                                   ay         as.s6    deay (25.8      49.2003 kiz)        |




                            oae: in oncoom. aeanne




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)         4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                              Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


Report Number:           F690501/RF—RTLO14157—1                                                      Page:   18                28




                            &                            me e      ToBP5
                                   FREQUENCY                     84 .4439       kHz
                                   xo          18.73      aBav (19.1          L4439 knz)
                                   cex         i2.14      aBav (12.3          L4439 knz)
                                   ay           a.23       aBav (11.0         L4439 knz)




                            oares anomcoomm. acanst




                            &                                      us3"
                                   FREQUENCY                    338 .5417       kHz
                                   xo          s2.79      aBpv (33.3          15417 knz)
                                   cex         s0.75      aBpv (30.8          15417 knz)
                                   ay          29.52.     deay (29.7          15417 knz)




                            oares an.omcaomm. aessicas




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)           4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807   hitp:/worw.sascroup ks
RTT5041—19(2019.04.24)(1)                                  Tel. +82 31 428 5700 / Fax. +82 31 427 2370       A4(210 mm x 297 mm)


 Report Number:              F690501/RE—RTLO14157—1                                              Page:            19         of        28


Above 30 Mz


    wmas
    iy                                                              cmove
                                                                    fnou                 reo rat issutent can
    doke
    aovem                                                           Em
                                                                    Eud
    e                                                               Emm
         mt
          it                                                                                                     «reosient &
          so                                                                                                     L
                                                                                                                 ——__— umrey Umay
                                                                                                                 ie one
          so                                                                                                                 seeciuntion
                                                                                                                 _ Erevnve o
          ro                                                                                                     ts SRSAR ienss
          so
          so
   lsw




          «
          s
          zo
          io
           o
          snov        seov               rovom                                  svoove                  voonom
                                                     reamsy                                              bewr



Remark;

— Traces shown in the plot were made by using a peak detector.




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)    4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807               Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                         Tel. +82 31 428 5700 / Fax. +82 31 427 2370                     A4(210 mm x 297 mm)


 Report Number:          F690501/RF—RTLO14157—1                                                     Page:    20                28


Ant. 2

Below 30 M

                            &                                     us 5
                                   FREQUENCY                    18.4904        kHz
                                   xo          29.30     deay (32.3       i8.4904 kiz)
                                   cex         25.04     deay (25.4       i8.4904 kiz)
                                   ay          22.99     deay (24.6       i8.4904 kiz)




                            oares an.omcaomm. aessocas




                            &                                     us 5
                                   FREQUENCY                    66.8686        kHz
                                   xo          18.95      aBpv (21.5      se.e686 knz)
                                   cex         16.72.    aBpv (16.7       se.e686 knz)
                                   ay          16.00     aBav (17.0       se.e686 knz)




                            oares an.omcaomm aessose




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)           4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807   hitp:/worw.sascroup ks
RTT5041—19(2019.04.24)(1)                                 Tel. +82 31 428 5700 / Fax. +82 31 427 2370        A4(210 mm x 297 mm)


Report Number:           F690501/RF—RTLO14157—1                                                    Page:     21                28



                            &                                     ol    es
                                   FREQUENCY                     84.3574      kHz
                                   xo          1s.92     aBpv (19.0       84.3574 knz)
                                   cex         is.8e     aBpv (13.3       84.3574 knz)       j
                                   ay          12.33     aBav (13.4       84.3574 knz)       ;




                            oares an.omcoomm. aesaacss




                            &                                     F o.
                                   FREQUENCY                    337.7404 kHz
                                   pro         s8.00     aBpv (38.4      337.7404 kmz)
                                   orK         36. 00    dBnv   (36.0    337.7404   kiz)
                                   Av          35. 29    dBnv   (35.5    337.7404   kiz)




                            oae: in oncoom. acanst




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)           4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807   hitp:/worw.sascroup ks
RTT5041—19(2019.04.24)(1)                                Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


 Report Number:          F690501/RE—RTLO14157—1                                             Page:          22              of      28




                               FREQUENCY             564.3718 kHz
                               pre  29.95         dny (30.6 seq.3718 knz)             ,
                               orK       27.65   dBny    (27.7   564.3718    kiz)     ;
                               Av        26.13   dBnv    (26.3   564.3718    kiz)     |


                             mm
                             _




Above 30 M



   in                                                               ce
    en
      1st
       s                                                                                                  To Goarn
                                                                                                          «roo surour 6>
                                                                                                             tnify
                                                                                                          gine on
        so                                                                                                                 sequntind
        o                                                                                                 200 SeQtearend
        so
        so
 t




        «o
        so
        2o
        is
         s
        sa ovo                        rovovo                                   se               vevvovo
                                                    reaseney                                      fured



Remark;

— Traces shown in the plot were made by using a peak detector.




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)    4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807       hitp:/worw.sascroup ks
RTT5041—19(2019.04.24)(1 )                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370              A4(210 mm x 297 mm)


 Report Number:          F690501/RF—RTLO14157—1                                                    Page:    23                28


Ant. 3

Below 30 M

                            &                                    us 5
                                   FREQUENCY                   19.6282        kHz
                                   xo         27.55      deay (31.3      19.6282 knz)
                                   cex        as.61.     deay (24.3      19.6282 knz)
                                   ay         20.62.     deay (23.1      19.6282 knz)




                            oares ancomcaomm acconcns




                            &                                    us 5
                                   FREQUENCY                   70.2751        kHa
                                   xo          19.43     aBpv (20.8      70.2751 kiz)
                                   cex         15.20     aBav (15.4      70.2751 kiz)
                                   ay          1is.54.   aBav (14.3      70.2751 kiz)




                            oares ancovcaom   acconcs0




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)          4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807   hitp:/worw.sascroup ks
RTT5041—19(2019.04.24)(1)                                Tel. +82 31 428 5700 / Fax. +82 31 427 2370        A4(210 mm x 297 mm)


Report Number:           F690501/RF—RTLO14157—1                                                       Page:   24                28




                            &                             me e      ToBP5
                                   FREQUENCY                      98. 4079       kHz
                                   x+          20. 57      deny (25.5          .4073 knz)
                                   goxk        14. 54      deny (15.0          .4073 knz)
                                   ay          12.17       depy (rals          .4073 knz)




                            oares an.ovcaom    accomos




                            &                                       us3"
                                   FREQUENCY                     337 .4199       kHz
                                   xo          33.00       aBav (33.5      337 24199 knz)
                                   cex         s0.97        aBav (31.0     337 24199 knz)
                                   ay          a29.77       deay (29.8     337 24199 knz)




                            oares an.ovcaomm   accosces




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)           4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807    hitp:/worw.sascroup ks
RTT5041—19(2019.04.24)(1)                                   Tel. +82 31 428 5700 / Fax. +82 31 427 2370       A4(210 mm x 297 mm)


 Report Number:             F690501/RE—RTLO14157—1                                          Page:         25        of      28


Above 30 Mz




    Ti                                                               mmn
    fmolline                                                         mm
                                                                                                          «reosmont &
                                                                                                          gerbe
                                                                                                          To mnecuntind
                                                                                                                      ho
                                                                                                          _ Siteetdianen
                                                                                                                      Seainien
                                                                                                          2




                                         omm                                    se use          rom ooo
                                                     remeny                                      toed




Remark;

— Traces shown in the plot were made by using a peak detector.




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)    4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807       Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                         Tel. +82 31 428 5700 / Fax. +82 31 427 2370             A4(210 mm x 297 mm)


 Report Number:             F690501/RE—RTLO14157—1                                         Page:     26       of       28


3. 20 dB Bandwidth
3.1. Test Setup




                                                                                               Spectrum
                   EUT                                                                         Analyzer




3.2. Limit

None:; for reporting purposed only

3.3. Test Procedure

   a. Span = set to capture all products of the modulation process, including the emission skirts.
      RBW = 200 Hz, VBW = 200 Hz, Sweep = auto, Detector = peak, Trace = max hold.
   b. The marker—to—peak function to set the mark to the peak of the emission. Use the marker—delta
     function to measure 20 dB down one side of the emission. Reset the function, and move the marker to
     the other side of the emission, until it is (as close as possible to) even with the reference marker level.
     The marker—delta reading at this point is 20 dB bandwidth of the emission.




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807   hitp:/worw.sascroup ks
RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


 Report Number:              F690501/RE—RTLO14157—1                                                                     Page:         27       of       28



3.4. Test Result

Ambient temperature                      (23 + 1) °C
Relative humidity                        47          %RH.

           is                                                                                                      20 dB                         hss
 Test condition                                       EUT status                                               Bandwidth (i)                    Limit


         Ant. 1                                                                                                      0.521


                                                  With client device                                                                         Reporting
         Ant. 2                     (1 % battery status of client device)                                            0.521                 propased only


         Ant. 3                                                                                                      0.521


— Test plots

Ant. 1

                  Spectrum                                                                                                            z>
                                                                                                                                       y
                   Ref Level —10.00 dem                   & Rew 200 hz
                   are             10 d8        SWT 50 ms @ VBW 200 Hz       Mode Swee
                  o irk max
                                                                                        malnl                                ~15.00 db
                                                                                                                          112.49570 ki
                  —20 dam                                                               maki]                                —8.91 dbm
                                                                                                                          112,20820 ki
                  —20 dom
                  40 dom
                  —50 dom
                  —0 dom
                                  1 —52.050 d
                  70 dam
                  —20 dom
                  o
                  —100 dam

                   or 112.5 ki                                           so1 pts                                           Spon 5.0 kiie
                  Marker
                   Type | Ret | Trc |           x—value            Y—value        |   runction                 Function Result
                      ms             1           112.4057 e         =3.06 dam
                      me             1           112,2952 ine       ~63.21 dam
                      bs!    ve      f               s21.0 he           a.65 ce
                                                                                                 Neasuring..




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)              4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807                         hitp:/worw.sascroup ks
RTT5041—19(2019.04.24)(1)                                       Tel. +82 31 428 5700 / Fax. +82 31 427 2370                           A4(210 mm x 297 mm)


 Report Number:                  F690501/RE—RTLO14157—1                                                                        Page:         28        of      28


Ant. 2

                  Spectrum                                                                                                                   T
                   Ref Level —10.00 dem                       & Rew 200 hz
                   am              10 d8            SWT 50 ms @ VBW 200 Hz           Mode Swee
                  o irk max
                                                                                                wmiru                               ~i2.66 db
                                                                                                                                 112.49570 ki
                  —20 dam                                                                       mati]                               —62.75 d
                                                                                                                                 112,20820 ki
                  —30 dom
                  40 dom
                  —50 dom
                  —0 dom              1 —52.500 d
                  70 dam
                            m
                  —20 dom
                  100 dam

                   cr 128 uie                                                    so1 pts                                          Spon 5.0 kiz
                  Marker
                   Type | Ref | Trc |               X—value         |      Y—value        |   unction                 Function Result
                      in                 i           121057 e               =2.60 dam
                      me                 i           112,2902 ine           —62.75 dam
                      osl       vel      i               s21.0 he               042 as
                                                                                                        Neasuring..



Ant. 3

                  Spectrum                                                                                                                   y
                   Ref Level —10.00 dem                       & Rew. 200 hz
                   am              10 d8            SWT 50 ms @ VBW 200 Hz           Mode Swee
                  o irk max
                                                                                                wmiru                               ~i4.64 d
                                                                                                                                 112.49570 kitel
                  «20 dam                                                                       mati]                               —64.96 d
                                                                                                                                 112,20820 ki
                  —20 dom
                  40 dom

                  —50 dom
                  —0 dom
                                      1 —s.600 d
                  70 dam
                  —20 dom
                  «0 d
                  —100 dam

                   or 112.5 ki                                                   so1 pts                                          Spon 5.0 kiie
                  Marker
                   Type | Ref | Trc |               X—value         |      Y—value        |   unction                 Function Result
                      in                 i           121057 e               ~#1.68 cam
                      me                 i           112,2902 lne           —68.90 dam
                      osl       vel      i               s21.0 he               0.63 as
                                                                                                        Neasuring..



                                                              — End of the Test Report —
mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)                  4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807                            Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                                               Tel. +82 31 428 5700 / Fax. +82 31 427 2370                          A4(210 mm x 297 mm)



Document Created: 2019-11-04 20:04:23
Document Modified: 2019-11-04 20:04:23

© 2024 FCC.report