RF Exoosure Info

FCC ID: OSLOKA-211W

RF Exposure Info

Download: PDF
FCCID_4450419

          —        l
 Report Number:             F690501/RF—RTLO14158                                              Page:       1      of      9




                             TEST REPORT
                                                           of

                               FCC CFR 47 part 1, 1.1307(b), 1.1310
                                          FCC ID: OSLOKA—211W

Equipment Under Test                : UNIT ASSY — WIRELESS CHARGING
Model Name                          : OKA—211W
Variant Model Name                  _: OKA—213W
Applicant                           : Omron Automotive Electronics Korea Co., Ltd.
Manufacturer                        : Omron Automotive Electronics Korea Co., Ltd.
Date of Receipt                     : 2019.05.07
Date of Test(s)                     : 2019.07.01 ~2019.07.29
Date of Issue                       : 2019.08.01



In the configuration tested, the EUT complied with the standards specified above.




  Tested By:           }///’                                       Date:                       2019.08.01
                                  //

                 /”              Murphy Kim


  Technical
  Manager:
                                                                   Date:                       2019.08.01

                                Jungmin Yang




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807    hitp/www.sqsgroup.kr
RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 /Fax. +82 31 427 2370           A4(210 mm x 297 mm)


Report Number:              F690501/RE—RTLO14158                                           Page:        2        of      9




                                              Contents
   1. G@N@rAl INfOPMANION ———————o———————ooononoonnno ooo cce n ons nc nnonnn ons ces cce ce

   2. T@St R@SUlt ————————oon on moemoennoonnoonnnonnonnnoennoennonnonnnonnnoenn en en nn n ne ce >




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


Report Number:              F690501/RE—RTLO14158                                             Page:        8        of      9


1. General Information

1.1. Testing Laboratory

SGS Korea Co., Ltd. (Gunpo Laboratory)
     — 10—2, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807
     — 4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807
     — Designation number: KRO150
All SGS services are rendered in accordance with the applicable SGS conditions of service available on
request and accessible at http://www.sqs.com/en/Terms—and—Conditions.aspx.
Phone No.              :    +82 31 688 0901
Fax No.                :    +82 31 688 0921

1.2. Details of Applicant
Applicant             :     Omron Automotive Electronics Korea Co., Ltd.
Address               :     790—12, Bogaewonsam—ro, Bogae—myeon, Anseang—si, Gyeonggi—do, South Korea,
                            17507
Contact Person        _:    Nam, Sang—ll
Phone No.             1     +822 850 5789

1.3. Details of Manufacturer
Company               :     Same as applicant
Address               :     Same as applicant

1.4. Description of EUT

 Kind of Product                     UNIT ASSY — WIRELESS CHARGING

 Model Name                          OKA—211W

 Variant Model Name                  OKA—213W

 Power Supply                        DC 12.0 V

 Frequency Range                     112 k

 Antenna Type                        Inductive loop coil antenna


1.5. Declaration by the Manufacturer
— The EUT has 3 loop coil antennas with one amplifier, and only one antenna can transmit at once.




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)     4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                          Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


 Report Number:              F690501/RE—RTLO14158                                            Page:                4     of        9


1.6. Test Equipment List

    :                                                                                                    Cal.
 Equipment           Manufacturer              Model                   S/N            Cal. Date        Interval        Cal. Due
     .                 D.A.R.E!!               .
 E—Field Probe                              RadiSense 4          13100444SNOO4 Jun. 24, 2019            Annual        Jun. 24, 2020
                      Instruments

 Magnetic
    Sensor
          Field           HIOKI               1087—c1                  a471          Aug 31, 2018       Annual |Aug. 31, 2019
 Magi't’:;'f;'e'd         HIOKI              FT3470—50              171129500        Aug 31, 2018       Annual Aug 31, 2019
   Anechoic                     .             Lx W x H
   Chamber           SY Corporation    (9.6 m x 6.4 m x 6.6 m)          N/A              N.C.R.             N/A          N.C.R.


> Support Equipment
            Description                       Manufacturer                       Model                         FCC ID

   Samsung Mobile Phone               Samsung Electronies Co., Ltd.           SM—G955N                      ASLSMGIS5N


1.7. Worst Case of Test Configurations

             EUT Configuration                                                  Description


               Charging Mode                                                   1 % of battery
              With Client Device                                                 o
             (Model: SM—G955N,                                                50 % of battery
            FCC ID: ASLSMG9S5N)                                               99 % of battery


Note;

EUT was investigated with client device under normal charging condition as above then worst value was only
reported.

1.8. Test report Revision

 Revision              Report Number                Date of Issue                            Description

        0           F690501/RF—RTLO14158               2019.08.01                                 Initial


1.9. Information of Variant Model

                 Model Name                                                     Description

     Basic Model              OKA—211 W         — Basic model

    Variant Model             OKA—213W          — Same to basic model except the cover case.


The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)    4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807         Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                          Tel. +82 31 428 5700 / Fax. +82 31 427 2370               A4(210 mm x 297 mm)


 Report Number:             F690501/RF—RTLO14158                                               Page:         5       of



2. Test Result

2.1. Test Setup




                                                                                 E—Field & B—Field Probe



                                                                                                   _
                                                                                                   D
                                           1
                                          1
                                         1



                                         Test distance




2.2. Measurement Procedure

a) The RF exposure test was performed in anechoic chamber.
b) The minimum separation distance to user is 6 cm. Thus, the measurement probe was placed at test
   distance (6, 8, 10, 13, 15 cm) which is between the edge of the charger and the geometric center of probe.
c) The highest emission level was recorded and compared with limit as soon as measurement of each points
   (A, B, C, D, E) were completed.
d) The EUT was measured according to the dictates of KDB 680106 DO1 v03.

Note;

— Bottom of EUT shall be connected into the vehicle.
  So these parts are not considered from MPE measurement.




 The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory)        4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807   http://www.sqsgroup.kr

RTT5041—19(2019.04.24)(1)                            Tel. +82 31 428 5700 / Fax. +82 31 427 2370          A4(210 mm x 297 mm)


 Report Number:              F690501/RE—RTLO14158                                           Page:        6        of      9


2.3. Equipment Approval Considerations item 5 b) of KDB 680106 D01 v03.
(1) Power transfer frequency is less that 1 .
   — The device operates at a frequency 112 k.

(2) Output power from each primary coil is less than or equal to 15 watts.
  — Output power from primary coil: 5 watts.

(3) The transfer system includes only single primary and secondary coils. This includes charging systems
that may have multiple primary coils and clients that are able to detect and allow coupling only between
individual pairs of coils.
 — The transfer system including a charging system with multiple primary coils are to detect and allow only
  between individual pairs of coils.

(4) Client device is placed directly in contact with the transmitter.
   — Client device is placed directly in contact with the transmitter.

(5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion).
   — Mobile exposure conditions only.

(6) The aggregate H—field strengths at 15. cm surrounding the device and 20 en above the top surface from
all simultangous transmitting coils are demonstrated to be less than 50 % of the MPE limit.
   — Refer to following test results.
     The EUT H—Field Strength levels at 15 en <50 % of the MPE H—Field Strength limit 1.63 A/m
     0.170 A/m (Max. at 15 cn) < 0.815 A/m




 The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
 the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
 withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)    4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

 RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


 Report Number:              F690501/RE—RTLO14158                                             Page:       7         of     9


2.4. Environmental Evaluation and Exposure Limit According to FCC CFR 47 part 1,
1.1307(b), 1.1310

§1.1310; The eriteria listed in the following table shall be used to evaluate the environment impact of human
exposure to radio frequency (RF) radiation as specified in §1.1307(b), except in the case of portable devices
which shall be evaluated according to the provisions of FCC part 2.1093 of this chapter.

                  TABLE 1 — LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)


 Freque?m?)/ Range           Elgt::reizgliiheld      Mag:ztrilt;z‘ield         Pow(en;l}Jc:’;sity      Av(i?r?li;I';l)ne
                                  (V/im)                   (A/m)

                                    (A) Limits for Occupational /Control Exposures

        0.3—3.0                    614                      1.63                     *(100)                     6

        3.0—30                    18427                    4.89/                   *(900/°)                     6

        30—300                     61.4                    0.163                      1.0                       6

      300—1 500                                                                      7300                       6

    1 500—100 000                                                                      5                        6

                              (B) Limits for General Population / Uncontral Exposures

       8.31.34                     614                     1.63                      *(100)                    30
        1.34—30                   824/                     2197                    *(180/f)                    30
        30—300                     27.5                    0.073                      0.2                      30

      300—1 500                                                                     t1 500                     30

    1 500—100 000                                                                      1.0                     30


t= frequency in M
*= Plane wave equivalent power density




mmz
 The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
 the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
 withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)     4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

 RTT5041—19(2019.04.24)(1)                         Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


 Report Number:             F690501/RE—RTLO14158                                              Page:           8    of         9


2.5. E and H Field Strength

Ambient temperature             :10   (2341) °C
Relative humidity               :0    47      % RH.

2.5.1. E—Field Strength at from The Edges Surrounding the EUT

Test Condition: Operating Mode with Client Device (1 % Battery Status of Client Device)



 Frec(x;;ncv      DiS(‘;')“’e         Pfi eanree eetece esb Ese                                                       IE{;T/::)S
                                      (V/im) (V/im) (V/im) (V/im) (V/im)

                      15               c.68           4.98            5.51            6.65             6.51
                      13               8.45           5.41            7.29            7.24             9.22


    112               10               13.80          10.50           4.01            11.80            12.90            614


                      8                18.20          12.50          14.20            13.70            18.40


                      6                20.20          41.00          25.10            24.40            32.00




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)     4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807    Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                          Tel. +82 31 428 5700 / Fax. +82 31 427 2370           A4(210 mm x 297 mm)


 Report Number:             F690501/RE—RTLO14158                                              Page:           9    of          9


2.5.2. H—Field Strength at from The Edges Surrounding the EUT

Test Condition: Operating Mode with Client Device (1 % Battery Status of Client Device)




 F""(‘;h")""y    Dis(‘;’)“"’ pronopallieenenei Econeriel esvenio esronke                                            WLZ
                                   (A/m)             (A/m)           (A/m)            (A/m)            (A/m)

                     15             0.10              0.10            0.12             0.11            0.17


                     13             0.11              0.13            0.12            0.15             0.21


     112             10             0.18              0.22            0.28            0.25             0.34             1.63


                      8             0.27              0.30            0.41            0.32             0.46


                      6             0.67              0.49            0.97            0.50             0.90


Remark:

1. H—field strength (A/m) = B—field (uT) / 1.25
2. Each antenna was tested. As worst condition, Ant. 3 is reported.




                                            — End of the Test Report —
mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)     4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807    hitp:/worw.sascroup ks
RTT5041—19(2019.04.24)(1)                          Tel. +82 31 428 5700 / Fax. +82 31 427 2370           A4(210 mm x 297 mm)



Document Created: 2019-11-04 20:47:38