RF Exposure Info._20190208_v1 - 4788805437-S1V1 FCC Report SAR App F_SAR Dipole

FCC ID: OPS16

RF Exposure Info

Download: PDF
FCCID_4174015















Justification for Extended SAR Dipole Calibrations

Instead of the typical annual calibration recommended by measurement standards, longer calibration intervals
of up to three years may be considered when it is demonstrated that the SAR target, impedance and return loss
of a dipole have remain stable according to the following requirements

KDB 865664 D01v01r04 requirements
a ) return loss : < - 20 dB, within 20% of previous measurement
b ) impedance : within 5 Ω from previous measurement

                                          Date of
  Dipole Antenna        Head/Body                        Return Loss (dB)    Δ%      Impedance (Ω)      ΔΩ
                                       Measurement
                                        2018-01-17            -24.05                      45.87
D2600V2-SN : 1097          Body                                             0.87                        -3.06
                                         2019-01-17           -23.84                      48.93



c ) Measured SAR : within 10% of that reported in the calibration data

                                           Date of        Measured SAR
  Dipole Antenna         Head/Body                                           Δ%
                                        Measurement         (W/kg)
                                         2018-01-17           5.52
D2600V2-SN : 1097           Body                                            -2.17
                                         2019-01-17           5.64





























Document Created: 2019-03-26 22:37:30