FCC ID: OPS16

RF Exposure Info

Download: PDF
FCCID_4174010

Test Laboratory: UL Korea Ltd. Suwon Laboratory                                            Date: 2019-01-29

20190129_SystemPerformanceCheck-D2600V2 SN 1097

Frequency: 2600 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                3
Medium parameters used: f = 2600 MHz; σ = 2.018 S/m; εr = 38.428; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1494; Calibrated: 2018-07-23
- Probe: EX3DV4 - SN7376; ConvF(7.3, 7.3, 7.3); Calibrated: 2018-09-26;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM (20deg probe tilt) with CRP v5.0_Front; Type: QD000P40CD; Serial: TP:1877

Head/Pin=100 mW/Area Scan (9x9x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 7.96 W/kg

Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 66.57 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 14.1 W/kg
SAR(1 g) = 6.05 W/kg; SAR(10 g) = 2.64 W/kg
Maximum value of SAR (measured) = 8.94 W/kg




                      0 dB = 8.94 W/kg = 9.51 dBW/kg




                                                                                                               Plot No. 1


Test Laboratory: UL Korea Ltd. Suwon Laboratory               Date: 2019-01-29

20190129_SystemPerformanceCheck-D2600V2 SN 1097

Frequency: 2600 MHz; Duty Cycle: 1:1

Head/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 8.74 W/kg




                                                                                 Plot No. 2


Test Laboratory: UL Korea Ltd. Suwon Laboratory                                            Date: 2019-01-07

20190107_SystemPerformanceCheck-D835V2 SN 4d194

Frequency: 835 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                               3
Medium parameters used: f = 835 MHz; σ = 0.998 S/m; εr = 55.244; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1447; Calibrated: 2018-03-15
- Probe: EX3DV4 - SN7313; ConvF(9.59, 9.59, 9.59); Calibrated: 2018-02-20;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v6.0; Type: QDOVA003AA; Serial: TP:2005

Body/Pin=100 mW/Area Scan (5x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.26 W/kg

Body/Pin=100 mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 35.98 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 1.55 W/kg
SAR(1 g) = 1.04 W/kg; SAR(10 g) = 0.684 W/kg
Maximum value of SAR (measured) = 1.27 W/kg




                      0 dB = 1.27 W/kg = 1.04 dBW/kg




                                                                                                               Plot No. 3


Test Laboratory: UL Korea Ltd. Suwon Laboratory               Date: 2019-01-07

20190107_SystemPerformanceCheck-D835V2 SN 4d194

Frequency: 835 MHz; Duty Cycle: 1:1

Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 1.27 W/kg




                                                                                 Plot No. 4


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-01-31

20190131_SystemPerformanceCheck-D5GHzV2 SN 1209

Frequency: 5600 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                3
Medium parameters used: f = 5600 MHz; σ = 5.892 S/m; εr = 48.171; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(4.03, 4.03, 4.03); Calibrated: 2018-08-30;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Phantom: ELI v6.0; Type: QDOVA003AA; Serial: TP:2005

Body/5.6 GHz, Pin=100mW/Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 16.1 W/kg

Body/5.6 GHz, Pin=100mW/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=1.4mm
Reference Value = 59.98 V/m; Power Drift = 0.19 dB
Peak SAR (extrapolated) = 37.7 W/kg
SAR(1 g) = 8.57 W/kg; SAR(10 g) = 2.34 W/kg
Maximum value of SAR (measured) = 20.7 W/kg




                      0 dB = 20.7 W/kg = 13.16 dBW/kg




                                                                                                               Plot No. 5


Test Laboratory: UL Korea, Ltd. Suwon Laboratory              Date: 2019-01-31

20190131_SystemPerformanceCheck-D5GHzV2 SN 1209

Frequency: 5600 MHz; Duty Cycle: 1:1

Body/5.6 GHz, Pin=100mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 10.8 W/kg




                                                                                      Plot No. 6


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-01-28

20190128_SystemPerformanceCheck-D2450V2 SN 960

Frequency: 2450 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                               3
Medium parameters used: f = 2450 MHz; σ = 2.01 S/m; εr = 52.526; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 2018-07-26
- Probe: EX3DV4 - SN3991; ConvF(7.72, 7.72, 7.72); Calibrated: 2018-05-24;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V5.0 (20deg probe tilt)_20181018; Type: QD OVA 001 BB; Serial: 1212

Body/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 6.88 W/kg

Body/Pin=100 mW/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 60.68 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 11.0 W/kg
SAR(1 g) = 5.26 W/kg; SAR(10 g) = 2.4 W/kg
Maximum value of SAR (measured) = 7.50 W/kg




                      0 dB = 7.50 W/kg = 8.75 dBW/kg




                                                                                                               Plot No. 7


Test Laboratory: UL Korea, Ltd. Suwon Laboratory               Date: 2019-01-28

20190128_SystemPerformanceCheck-D2450V2 SN 960

Frequency: 2450 MHz; Duty Cycle: 1:1

Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 3.64 W/kg




                                                                                  Plot No. 8


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-01-31

20190131_SystemPerformanceCheck-D1900V2 SN 5d199

Frequency: 1900 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                              3
Medium parameters used: f = 1900 MHz; σ = 1.5 S/m; εr = 53.784; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 2018-07-26
- Probe: EX3DV4 - SN3991; ConvF(8.03, 8.03, 8.03); Calibrated: 2018-05-24;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V5.0 (20deg probe tilt)_20181018; Type: QD OVA 001 BB; Serial: 1212

Body/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 4.97 W/kg

Body/Pin=100 mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 57.48 V/m; Power Drift = 0.17 dB
Peak SAR (extrapolated) = 7.61 W/kg
SAR(1 g) = 4.29 W/kg; SAR(10 g) = 2.26 W/kg
Maximum value of SAR (measured) = 5.73 W/kg




                      0 dB = 5.73 W/kg = 7.58 dBW/kg




                                                                                                               Plot No. 9


Test Laboratory: UL Korea, Ltd. Suwon Laboratory               Date: 2019-01-31

20190131_SystemPerformanceCheck-D1900V2 SN 5d199

Frequency: 1900 MHz; Duty Cycle: 1:1

Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 4.88 W/kg




                                                                                  Plot No. 10