RF Exposure Info._20190208_v1 - 4788805437-S1V1 FCC Report SAR App B_SAR Highest

FCC ID: OPS16

RF Exposure Info

Download: PDF
FCCID_4174009

Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                             Date: 2019-01-10

GSM 850

Frequency: 836.6 MHz; Duty Cycle: 1:1.99986;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.909 S/m; εr = 41.277; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(9.47, 9.47, 9.47); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM Phantom CRP v5.0(Right); Type: QD000P40CD; Serial: TP:1855

RHS/Touch_GPRS 4slot_ch.190/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.229 W/kg

RHS/Touch_GPRS 4slot_ch.190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 16.36 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 0.261 W/kg
SAR(1 g) = 0.204 W/kg; SAR(10 g) = 0.158 W/kg
Maximum value of SAR (measured) = 0.226 W/kg




                      0 dB = 0.226 W/kg = -6.46 dBW/kg




                                                                                                                Plot No. 1


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-01-16

GSM 850

Frequency: 836.6 MHz; Duty Cycle: 1:1.99986;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.972 S/m; εr = 54.01; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1447; Calibrated: 2018-03-15
- Probe: EX3DV4 - SN7313; ConvF(9.59, 9.59, 9.59); Calibrated: 2018-02-20;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v6.0; Type: QDOVA003AA; Serial: TP:2005

Rear/GPRS_4 slots_ch 190 15mm/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.423 W/kg

Rear/GPRS_4 slots_ch 190 15mm/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 21.46 V/m; Power Drift = -0.17 dB
Peak SAR (extrapolated) = 0.671 W/kg
SAR(1 g) = 0.384 W/kg; SAR(10 g) = 0.217 W/kg
Maximum value of SAR (measured) = 0.504 W/kg




                      0 dB = 0.504 W/kg = -2.98 dBW/kg




                                                                                                                Plot No. 2


Test Laboratory: UL Korea Ltd. Suwon Laboratory                                             Date: 2019-01-15

GSM 850

Frequency: 836.6 MHz; Duty Cycle: 1:1.99986;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.972 S/m; εr = 54.01; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1447; Calibrated: 2018-03-15
- Probe: EX3DV4 - SN7313; ConvF(9.59, 9.59, 9.59); Calibrated: 2018-02-20;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v6.0; Type: QDOVA003AA; Serial: TP:2005

Rear/GPRS_4 Slots_ch 190 10mm (Hotspot)/Area Scan (8x14x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 1.08 W/kg

Rear/GPRS_4 Slots_ch 190 10mm (Hotspot)/Zoom Scan (5x5x7)/Cube 0: Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 33.84 V/m; Power Drift = 0.12 dB
Peak SAR (extrapolated) = 1.62 W/kg
SAR(1 g) = 0.855 W/kg; SAR(10 g) = 0.454 W/kg
Maximum value of SAR (measured) = 1.16 W/kg




                      0 dB = 1.16 W/kg = 0.64 dBW/kg




                                                                                                                Plot No. 3


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 1/14/2019

GSM 1900_GPRS

Frequency: 1909.8 MHz; Duty Cycle: 1:4.00037;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used: f = 1910 MHz; σ = 1.41 S/m; εr = 39.752; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 7/26/2018
- Probe: EX3DV4 - SN3991; ConvF(8.43, 8.43, 8.43); Calibrated: 5/24/2018;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: Twin-SAM V5.0 (30deg probe tilt)_20181018; Type: QD 000 P40 CD; Serial: 1829

LHS/Touch_GPRS 2slot_ch.810/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.0213 W/kg

LHS/Touch_GPRS 2slot_ch.810/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 3.858 V/m; Power Drift = 0.07 dB
Peak SAR (extrapolated) = 0.0290 W/kg
SAR(1 g) = 0.017 W/kg; SAR(10 g) = 0.00995 W/kg
Maximum value of SAR (measured) = 0.0226 W/kg




                     0 dB = 0.0226 W/kg = -16.46 dBW/kg




                                                                                                              Plot No. 4


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-01-16

GSM 1900

Frequency: 1909.8 MHz; Duty Cycle: 1:4.00037;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used: f = 1910 MHz; σ = 1.59 S/m; εr = 54.343; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(7.74, 7.74, 7.74); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v6.0; Type: QDOVA003AA; Serial: TP:2005

Rear/GPRS_2 slots_ch 810 15mm/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.0412 W/kg

Rear/GPRS_2 slots_ch 810 15mm/Zoom Scan (6x6x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 5.261 V/m; Power Drift = -0.13 dB
Peak SAR (extrapolated) = 0.0570 W/kg
SAR(1 g) = 0.032 W/kg; SAR(10 g) = 0.017 W/kg
Maximum value of SAR (measured) = 0.0411 W/kg




                      0 dB = 0.0411 W/kg = -13.86 dBW/kg




                                                                                                               Plot No. 5


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-01-16

GSM 1900

Frequency: 1909.8 MHz; Duty Cycle: 1:4.00037;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used: f = 1910 MHz; σ = 1.59 S/m; εr = 54.343; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(7.74, 7.74, 7.74); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v6.0; Type: QDOVA003AA; Serial: TP:2005

Rear/GPRS_2 slots_ch 810 10mm/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.0933 W/kg

Rear/GPRS_2 slots_ch 810 10mm/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 7.881 V/m; Power Drift = -0.07 dB
Peak SAR (extrapolated) = 0.146 W/kg
SAR(1 g) = 0.076 W/kg; SAR(10 g) = 0.039 W/kg
Maximum value of SAR (measured) = 0.104 W/kg




                      0 dB = 0.104 W/kg = -9.83 dBW/kg




                                                                                                               Plot No. 6


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 1/21/2019

W-CDMA Band II

Frequency: 1907.6 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 1907.6 MHz; σ = 1.402 S/m; εr = 39.595; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 7/26/2018
- Probe: EX3DV4 - SN3991; ConvF(8.43, 8.43, 8.43); Calibrated: 5/24/2018;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: Twin-SAM V5.0 (30deg probe tilt)_20181018; Type: QD 000 P40 CD; Serial: 1829

LHS/Touch_RMC Rel.99 ch 9538/Area Scan (7x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.305 W/kg

LHS/Touch_RMC Rel.99 ch 9538/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 14.981 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 0.400 W/kg
SAR(1 g) = 0.249 W/kg; SAR(10 g) = 0.153 W/kg
Maximum value of SAR (measured) = 0.311 W/kg




                     0 dB = 0.311 W/kg = -5.07 dBW/kg




                                                                                                               Plot No. 7


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-01-18

W-CDMA Band II

Frequency: 1907.6 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 1907.6 MHz; σ = 1.571 S/m; εr = 51.972; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(7.74, 7.74, 7.74); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v6.0; Type: QDOVA003AA; Serial: TP:2005

Rear/Rel.99_ch 9538 15mm/Area Scan (7x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.413 W/kg

Rear/Rel.99_ch 9538 15mm/Zoom Scan (6x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 16.94 V/m; Power Drift = -0.02 dB
Peak SAR (extrapolated) = 0.634 W/kg
SAR(1 g) = 0.325 W/kg; SAR(10 g) = 0.200 W/kg
Maximum value of SAR (measured) = 0.470 W/kg




                      0 dB = 0.470 W/kg = -3.28 dBW/kg




                                                                                                               Plot No. 8


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 1/31/2019

W-CDMA Band II

Frequency: 1852.4 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 1852.4 MHz; σ = 1.46 S/m; εr = 53.925; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 7/26/2018
- Probe: EX3DV4 - SN3991; ConvF(8.03, 8.03, 8.03); Calibrated: 5/24/2018;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V5.0 (20deg probe tilt)_20181018; Type: QD OVA 001 BB; Serial: 1212

Rear/Rel.99_ch 9262 10mm (Hotspot)/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.357 W/kg

Rear/Rel.99_ch 9262 10mm (Hotspot)/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 15.75 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 0.468 W/kg
SAR(1 g) = 0.264 W/kg; SAR(10 g) = 0.147 W/kg
Maximum value of SAR (measured) = 0.335 W/kg




                      0 dB = 0.335 W/kg = -4.75 dBW/kg




                                                                                                               Plot No. 9


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-01-10

W-CDMA Band V

Frequency: 836.6 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.909 S/m; εr = 41.277; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(9.47, 9.47, 9.47); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM Phantom CRP v5.0(Right); Type: QD000P40CD; Serial: TP:1855

RHS/Touch_RMC Rel.99 ch 4183/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.0460 W/kg

RHS/Touch_RMC Rel.99 ch 4183/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 7.610 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 0.0540 W/kg
SAR(1 g) = 0.042 W/kg; SAR(10 g) = 0.032 W/kg
Maximum value of SAR (measured) = 0.0470 W/kg




                      0 dB = 0.0470 W/kg = -13.28 dBW/kg




                                                                                                               Plot No. 10


Test Laboratory: UL Korea Ltd. Suwon Laboratory                                            Date: 2019-01-11

W-CDMA Band V

Frequency: 836.6 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 836.6 MHz; σ = 1.008 S/m; εr = 55.757; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1447; Calibrated: 2018-03-15
- Probe: EX3DV4 - SN7313; ConvF(9.59, 9.59, 9.59); Calibrated: 2018-02-20;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v6.0; Type: QDOVA003AA; Serial: TP:2005

Rear/Rel.99_ch 4183 15mm/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.167 W/kg

Rear/Rel.99_ch 4183 15mm/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 14.03 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 0.257 W/kg
SAR(1 g) = 0.148 W/kg; SAR(10 g) = 0.082 W/kg
Maximum value of SAR (measured) = 0.194 W/kg




                      0 dB = 0.194 W/kg = -7.12 dBW/kg




                                                                                                               Plot No. 11


Test Laboratory: UL Korea Ltd. Suwon Laboratory                                            Date: 2019-01-12

W-CDMA Band V

Frequency: 836.6 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 836.6 MHz; σ = 1.008 S/m; εr = 55.757; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1447; Calibrated: 2018-03-15
- Probe: EX3DV4 - SN7313; ConvF(9.59, 9.59, 9.59); Calibrated: 2018-02-20;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v6.0; Type: QDOVA003AA; Serial: TP:2005

Rear/Rel.99_ch 4183 10mm/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.485 W/kg

Rear/Rel.99_ch 4183 10mm/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 22.90 V/m; Power Drift = -0.07 dB
Peak SAR (extrapolated) = 0.748 W/kg
SAR(1 g) = 0.379 W/kg; SAR(10 g) = 0.193 W/kg
Maximum value of SAR (measured) = 0.522 W/kg




                      0 dB = 0.522 W/kg = -2.82 dBW/kg




                                                                                                               Plot No. 12


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-01-10

LTE Band 5

Frequency: 836.5 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 836.5 MHz; σ = 0.909 S/m; εr = 41.278; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(9.47, 9.47, 9.47); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM Phantom CRP v5.0(Right); Type: QD000P40CD; Serial: TP:1855

RHS/Touch_QPSK RB 1/0 ch 20525/Area Scan (7x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.178 W/kg

RHS/Touch_QPSK RB 1/0 ch 20525/Zoom Scan (6x6x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 14.49 V/m; Power Drift = 0.11 dB
Peak SAR (extrapolated) = 0.198 W/kg
SAR(1 g) = 0.157 W/kg; SAR(10 g) = 0.121 W/kg
Maximum value of SAR (measured) = 0.173 W/kg




                      0 dB = 0.173 W/kg = -7.62 dBW/kg




                                                                                                               Plot No. 13


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 1/10/2019

LTE Band 5

Frequency: 836.5 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 836.5 MHz; σ = 1.008 S/m; εr = 55.758; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1447; Calibrated: 3/15/2018
- Probe: EX3DV4 - SN7313; ConvF(9.59, 9.59, 9.59); Calibrated: 2/20/2018;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v6.0; Type: QDOVA003AA; Serial: TP:2005

Rear/QPSK RB 1/0 Ch 20525 15 mm/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.304 W/kg

Rear/QPSK RB 1/0 Ch 20525 15 mm/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 19.06 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 0.474 W/kg
SAR(1 g) = 0.275 W/kg; SAR(10 g) = 0.156 W/kg
Maximum value of SAR (measured) = 0.359 W/kg




                      0 dB = 0.359 W/kg = -4.45 dBW/kg




                                                                                                               Plot No. 14


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 1/10/2019

LTE Band 5

Frequency: 836.5 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 836.5 MHz; σ = 1.008 S/m; εr = 55.758; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1447; Calibrated: 3/15/2018
- Probe: EX3DV4 - SN7313; ConvF(9.59, 9.59, 9.59); Calibrated: 2/20/2018;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v6.0; Type: QDOVA003AA; Serial: TP:2005

Rear/QPSK RB 1/0 Ch 20525 10 mm/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.712 W/kg

Rear/QPSK RB 1/0 Ch 20525 10 mm/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 28.38 V/m; Power Drift = -0.14 dB
Peak SAR (extrapolated) = 1.16 W/kg
SAR(1 g) = 0.607 W/kg; SAR(10 g) = 0.317 W/kg
Maximum value of SAR (measured) = 0.791 W/kg




                      0 dB = 0.791 W/kg = -1.02 dBW/kg




                                                                                                               Plot No. 15


Test Laboratory: UL Korea Ltd. Suwon Laboratory                                            Date: 2019-01-29

LTE Band 41

Frequency: 2506 MHz; Duty Cycle: 1:1.59956;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 2506 MHz; σ = 1.915 S/m; εr = 38.753; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1494; Calibrated: 2018-07-23
- Probe: EX3DV4 - SN7376; ConvF(7.3, 7.3, 7.3); Calibrated: 2018-09-26;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM (20deg probe tilt) with CRP v5.0_Front; Type: QD000P40CD; Serial: TP:1877

RHS/Touch_QPSK RB 1/0_ch 39750/Area Scan (9x16x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.138 W/kg

RHS/Touch_QPSK RB 1/0_ch 39750/Zoom Scan (8x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 8.562 V/m; Power Drift = 0.11 dB
Peak SAR (extrapolated) = 0.197 W/kg
SAR(1 g) = 0.103 W/kg; SAR(10 g) = 0.053 W/kg
Maximum value of SAR (measured) = 0.136 W/kg




                      0 dB = 0.136 W/kg = -8.66 dBW/kg




                                                                                                           Plot No. 16


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 1/21/2019

LTE Band 41

Frequency: 2506 MHz; Duty Cycle: 1:1.59956;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 2506 MHz; σ = 2.114 S/m; εr = 52.36; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 7/26/2018
- Probe: EX3DV4 - SN3991; ConvF(7.6, 7.6, 7.6); Calibrated: 5/24/2018;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V5.0 (20deg probe tilt)_20181018; Type: QD OVA 001 BB; Serial: 1212

Rear/QPSK RB 1/0 ch 39750 15mm/Area Scan (9x17x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.302 W/kg

Rear/QPSK RB 1/0 ch 39750 15mm/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 15.12 V/m; Power Drift = -0.06 dB
Peak SAR (extrapolated) = 0.623 W/kg
SAR(1 g) = 0.284 W/kg; SAR(10 g) = 0.145 W/kg
Maximum value of SAR (measured) = 0.424 W/kg




                      0 dB = 0.424 W/kg = -3.73 dBW/kg




                                                                                                              Plot No. 17


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 1/21/2019

LTE Band 41

Frequency: 2506 MHz; Duty Cycle: 1:1.59956;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 2506 MHz; σ = 2.114 S/m; εr = 52.36; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 7/26/2018
- Probe: EX3DV4 - SN3991; ConvF(7.6, 7.6, 7.6); Calibrated: 5/24/2018;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V5.0 (20deg probe tilt)_20181018; Type: QD OVA 001 BB; Serial: 1212

Rear/QPSK RB 1/0 ch 39750 10mm/Area Scan (9x17x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.718 W/kg

Rear/QPSK RB 1/0 ch 39750 10mm/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 16.02 V/m; Power Drift = -0.11 dB
Peak SAR (extrapolated) = 1.11 W/kg
SAR(1 g) = 0.517 W/kg; SAR(10 g) = 0.246 W/kg
Maximum value of SAR (measured) = 0.736 W/kg




                      0 dB = 0.736 W/kg = -1.33 dBW/kg




                                                                                                              Plot No. 18


Test Laboratory: UL Korea Ltd. Suwon Laboratory                                            Date: 2019-01-31

Wi-Fi 2.4 GHz

Frequency: 2462 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 2462 MHz; σ = 1.839 S/m; εr = 39.603; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1447; Calibrated: 2018-03-15
- Probe: EX3DV4 - SN7313; ConvF(7.43, 7.43, 7.43); Calibrated: 2018-02-20;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM (20deg probe tilt) with CRP v5.0(Middle); Type: QD000P40CD; Serial: TP:1847

LHS/Tilt_802.11 b mode ch 11 Ant 1/Area Scan (9x17x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.495 W/kg

LHS/Tilt_802.11 b mode ch 11 Ant 1/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 16.82 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 0.885 W/kg
SAR(1 g) = 0.333 W/kg; SAR(10 g) = 0.135 W/kg

Maximum value of SAR (measured) = 0.507 W/kg




                      0 dB = 0.507 W/kg = -2.95 dBW/kg




                                                                                                           Plot No. 19


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 1/30/2019

Wi-Fi 2.4 GHz

Frequency: 2462 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 2462 MHz; σ = 2.024 S/m; εr = 52.496; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 7/26/2018
- Probe: EX3DV4 - SN3991; ConvF(7.72, 7.72, 7.72); Calibrated: 5/24/2018;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V5.0 (20deg probe tilt)_20181018; Type: QD OVA 001 BB; Serial: 1212

Rear/802.11 b mode ch 11 15mm/Area Scan (17x9x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.118 W/kg

Rear/802.11 b mode ch 11 15mm/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 7.717 V/m; Power Drift = 0.10 dB
Peak SAR (extrapolated) = 0.198 W/kg
SAR(1 g) = 0.097 W/kg; SAR(10 g) = 0.045 W/kg
Maximum value of SAR (measured) = 0.132 W/kg




                      0 dB = 0.132 W/kg = -8.79 dBW/kg




                                                                                                               Plot No. 20


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 1/30/2019

Wi-Fi 2.4 GHz

Frequency: 2462 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 2462 MHz; σ = 2.024 S/m; εr = 52.496; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 7/26/2018
- Probe: EX3DV4 - SN3991; ConvF(7.72, 7.72, 7.72); Calibrated: 5/24/2018;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V5.0 (20deg probe tilt)_20181018; Type: QD OVA 001 BB; Serial: 1212

Rear/802.11 b mode ch 11 10mm/Area Scan (17x9x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.292 W/kg

Rear/802.11 b mode ch 11 10mm/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 13.678 V/m; Power Drift = 0.11 dB
Peak SAR (extrapolated) = 0.540 W/kg
SAR(1 g) = 0.241 W/kg; SAR(10 g) = 0.103 W/kg
Maximum value of SAR (measured) = 0.345 W/kg




                     0 dB = 0.345 W/kg = -4.62 dBW/kg




                                                                                                               Plot No. 21


Test Laboratory: UL Korea Ltd. Suwon Laboratory                                            Date: 2019-02-01

Wi-Fi 5.2 GHz

Frequency: 5220 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used: f = 5220 MHz; σ = 4.79 S/m; εr = 35.266; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1494; Calibrated: 2018-07-23
- Probe: EX3DV4 - SN7376; ConvF(5.12, 5.12, 5.12); Calibrated: 2018-09-26;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Phantom: SAM (20deg probe tilt) with CRP v5.0_Back; Type: QD000P40CD; Serial: TP:1882

LHS/Tilt_802.11 a mode ch 44/Area Scan (10x20x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.675 W/kg

LHS/Tilt_802.11 a mode ch 44/Zoom Scan (8x9x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=1.4mm
Reference Value = 10.57 V/m; Power Drift = -0.07 dB
Peak SAR (extrapolated) = 1.59 W/kg
SAR(1 g) = 0.349 W/kg; SAR(10 g) = 0.091 W/kg
Maximum value of SAR (measured) = 0.889 W/kg




                      0 dB = 0.889 W/kg = -0.51 dBW/kg




                                                                                                               Plot No. 22


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-02-07

Wi-Fi 5.2 GHz

Frequency: 5180 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used: f = 5180 MHz; σ = 5.106 S/m; εr = 47.625; ρ = 1000 kg/m3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(4.77, 4.77, 4.77); Calibrated: 2018-08-30;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Phantom: ELI v6.0; Type: QDOVA003AA; Serial: TP:2005

Rear/802.11 a mode ch 36 15mm/Area Scan (20x11x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.189 W/kg

Rear/802.11 a mode ch 36 15mm/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=1.4mm
Reference Value = 7.220 V/m; Power Drift = -0.19 dB
Peak SAR (extrapolated) = 0.347 W/kg
SAR(1 g) = 0.085 W/kg; SAR(10 g) = 0.032 W/kg
Maximum value of SAR (measured) = 0.195 W/kg




                      0 dB = 0.195 W/kg = -7.10 dBW/kg




                                                                                                               Plot No. 23


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-02-07

Wi-Fi 5.2 GHz

Frequency: 5180 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used: f = 5180 MHz; σ = 5.106 S/m; εr = 47.625; ρ = 1000 kg/m3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(4.77, 4.77, 4.77); Calibrated: 2018-08-30;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Phantom: ELI v6.0; Type: QDOVA003AA; Serial: TP:2005

Edge 1/802.11 a mode ch 36 0mm/Area Scan (13x6x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 4.22 W/kg

Edge 1/802.11 a mode ch 36 0mm/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm,
dy=4mm, dz=1.4mm
Reference Value = 43.67 V/m; Power Drift = -0.10 dB
Peak SAR (extrapolated) = 16.6 W/kg
SAR(1 g) = 2.18 W/kg; SAR(10 g) = 0.354 W/kg
Maximum value of SAR (measured) = 8.41 W/kg




                      0 dB = 8.41 W/kg = 9.25 dBW/kg




                                                                                                               Plot No. 24


Test Laboratory: UL Korea Ltd. Suwon Laboratory                                            Date: 2019-02-01

Wi-Fi 5.6 GHz

Frequency: 5500 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used: f = 5500 MHz; σ = 5.089 S/m; εr = 34.727; ρ = 1000 kg/m3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1494; Calibrated: 2018-07-23
- Probe: EX3DV4 - SN7376; ConvF(4.6, 4.6, 4.6); Calibrated: 2018-09-26;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Phantom: SAM (20deg probe tilt) with CRP v5.0_Back; Type: QD000P40CD; Serial: TP:1882

LHS/Tilt_802.11 a mode ch 100/Area Scan (10x20x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 1.93 W/kg

LHS/Tilt_802.11 a mode ch 100/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=1.4mm
Reference Value = 16.64 V/m; Power Drift = -0.14 dB
Peak SAR (extrapolated) = 3.41 W/kg
SAR(1 g) = 0.704 W/kg; SAR(10 g) = 0.193 W/kg
Maximum value of SAR (measured) = 1.83 W/kg




                      0 dB = 1.83 W/kg = 2.62 dBW/kg




                                                                                                               Plot No. 25


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-02-01

Wi-Fi 5.5 GHz

Frequency: 5500 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used: f = 5500 MHz; σ = 5.779 S/m; εr = 48.315; ρ = 1000 kg/m3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(4.03, 4.03, 4.03); Calibrated: 2018-08-30;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Phantom: ELI v6.0; Type: QDOVA003AA; Serial: TP:2005

Rear/802.11 a mode ch 100 15mm/Area Scan (20x11x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.511 W/kg

Rear/802.11 a mode ch 100 15mm/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm,
dy=4mm, dz=1.4mm
Reference Value = 10.91 V/m; Power Drift = -0.10 dB
Peak SAR (extrapolated) = 0.875 W/kg
SAR(1 g) = 0.219 W/kg; SAR(10 g) = 0.085 W/kg
Maximum value of SAR (measured) = 0.513 W/kg




                      0 dB = 0.513 W/kg = -2.90 dBW/kg




                                                                                                               Plot No. 26


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-02-01

Wi-Fi 5.5 GHz

Frequency: 5500 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used: f = 5500 MHz; σ = 5.779 S/m; εr = 48.315; ρ = 1000 kg/m3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(4.03, 4.03, 4.03); Calibrated: 2018-08-30;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Phantom: ELI v6.0; Type: QDOVA003AA; Serial: TP:2005

Edge 1/802.11 a mode ch 100 0mm/Area Scan (13x6x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 12.0 W/kg

Edge 1/802.11 a mode ch 100 0mm/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm,
dy=4mm, dz=1.4mm
Reference Value = 66.67 V/m; Power Drift = -0.19 dB
Peak SAR (extrapolated) = 43.3 W/kg
SAR(1 g) = 5.1 W/kg; SAR(10 g) = 0.847 W/kg
Maximum value of SAR (measured) = 17.3 W/kg




                      0 dB = 17.3 W/kg = 12.38 dBW/kg




                                                                                                               Plot No. 27


Test Laboratory: UL Korea Ltd. Suwon Laboratory                                            Date: 2019-02-02

Wi-Fi 5.8 GHz

Frequency: 5825 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used: f = 5825 MHz; σ = 5.471 S/m; εr = 34.173; ρ = 1000 kg/m3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1494; Calibrated: 2018-07-23
- Probe: EX3DV4 - SN7376; ConvF(4.63, 4.63, 4.63); Calibrated: 2018-09-26;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Phantom: SAM (20deg probe tilt) with CRP v5.0_Back; Type: QD000P40CD; Serial: TP:1882

LHS/Tilt_802.11 a mode ch 165/Area Scan (10x20x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.718 W/kg

LHS/Tilt_802.11 a mode ch 165/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=1.4mm
Reference Value = 8.367 V/m; Power Drift = 0.12 dB
Peak SAR (extrapolated) = 1.31 W/kg
SAR(1 g) = 0.248 W/kg; SAR(10 g) = 0.068 W/kg
Maximum value of SAR (measured) = 0.682 W/kg




                      0 dB = 0.682 W/kg = -1.66 dBW/kg




                                                                                                               Plot No. 28


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-02-01

Wi-Fi 5.8 GHz

Frequency: 5745 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used: f = 5745 MHz; σ = 6.106 S/m; εr = 47.956; ρ = 1000 kg/m3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(4.31, 4.31, 4.31); Calibrated: 2018-08-30;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Phantom: ELI v6.0; Type: QDOVA003AA; Serial: TP:2005

Rear/802.11 a mode ch 149 15mm/Area Scan (20x11x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.434 W/kg

Rear/802.11 a mode ch 149 15mm/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm,
dy=4mm, dz=1.4mm
Reference Value = 9.868 V/m; Power Drift = -0.10 dB
Peak SAR (extrapolated) = 0.796 W/kg
SAR(1 g) = 0.190 W/kg; SAR(10 g) = 0.074 W/kg
Maximum value of SAR (measured) = 0.446 W/kg




                      0 dB = 0.446 W/kg = -3.51 dBW/kg




                                                                                                               Plot No. 29


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-02-01

Wi-Fi 5.8 GHz

Frequency: 5745 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used: f = 5745 MHz; σ = 6.106 S/m; εr = 47.956; ρ = 1000 kg/m3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(4.31, 4.31, 4.31); Calibrated: 2018-08-30;
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Phantom: ELI v6.0; Type: QDOVA003AA; Serial: TP:2005

Edge 1/802.11 a mode ch 149 10mm/Area Scan (13x6x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.796 W/kg

Edge 1/802.11 a mode ch 149 10mm/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm,
dy=4mm, dz=1.4mm
Reference Value = 13.17 V/m; Power Drift = -0.19 dB
Peak SAR (extrapolated) = 1.44 W/kg
SAR(1 g) = 0.337 W/kg; SAR(10 g) = 0.110 W/kg
Maximum value of SAR (measured) = 0.830 W/kg




                      0 dB = 0.830 W/kg = -0.81 dBW/kg




                                                                                                               Plot No. 30


Test Laboratory: UL Korea Ltd. Suwon Laboratory                                            Date: 2019-01-16

Bluetooth

Frequency: 2441 MHz; Duty Cycle: 1:1.29033;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
Medium parameters used (interpolated): f = 2441 MHz; σ = 1.742 S/m; εr = 39.795; ρ = 1000 kg/m 3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1494; Calibrated: 2018-07-23
- Probe: EX3DV4 - SN7376; ConvF(7.4, 7.4, 7.4); Calibrated: 2018-09-26;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM (20deg probe tilt) with CRP v5.0_Front; Type: QD000P40CD; Serial: TP:1877

LHS/Tilt__bluetooth_GFSK_ch 39/Area Scan (9x17x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.164 W/kg

LHS/Tilt__bluetooth_GFSK_ch 39/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 9.129 V/m; Power Drift = 0.05 dB
Peak SAR (extrapolated) = 0.301 W/kg
SAR(1 g) = 0.112 W/kg; SAR(10 g) = 0.045 W/kg
Maximum value of SAR (measured) = 0.174 W/kg




                      0 dB = 0.174 W/kg = -7.59 dBW/kg




                                                                                                           Plot No. 31



Document Created: 2019-03-28 01:09:48
Document Modified: 2019-03-28 01:09:48