RF Exposure info

FCC ID: OPDPA450UM

RF Exposure Info

Download: PDF
FCCID_2027442

              R


                                                    AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:OPDPA450UM                                                                                page          12-2

  12. RF EXPOSURE STATEMENT

      According to FCC KDB 447498 D01:
      The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
      ≤ 50 mm are determined by:
      [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
      mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where

     f(GHz) is the RF channel transmit frequency in GHz
     Power and distance are rounded to the nearest mW and mm before calculation
     The result is rounded to one decimal place for comparison

     As to this device,
     The max.power of channel is -4.659dBm=0.342mW
     The min.test separation distance=5mm
     F(GHz)=2.402

     So the result=(0.342 mW /5mm)* √2.402=0.106<3
     Then the SAR Test to this device can be excluded.




                                                         Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F13187



Document Created: 2013-07-25 18:43:54
Document Modified: 2013-07-25 18:43:54