Test Report

FCC ID: OMO-M-05

Test Report

Download: PDF
FCCID_1199329

                                                                                               Page 1 of 25




                                  FCC CERTIFICATION
                                       On Behalf of
                                   La Crosse Technology

                                      Rain Sensor
                                  Model No.: TX58U-IT

                                   FCC ID: OMO-M-05




            Prepared for     :   La Crosse Technology
            Address          :   2809 Losey Blvd. So. La Crosse WI 54601, USA

            Prepared by      :   ACCURATE TECHNOLOGY CO. LTD
            Address          :   F1, Bldg. A, Changyuan New Material Port, Keyuan Rd.
                                 Science & Industry Park, Nanshan, Shenzhen, Guangdong
                                 P.R. China

                                 Tel: (0755) 26503290
                                 Fax: (0755) 26503396




            Report Number    :   ATE20091797
            Date of Test     :   October 14-16, 2009
            Date of Report   :   October 30, 2009




FCC ID: OMO-M-05                                        ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                                                                                                           Page 2 of 25




                                                             TABLE OF CONTENTS

      Description                                                                                                                                                Page


      Test Report Certification
     1.      GENERAL INFORMATION .......................................................................................................... 4
          1.1.      Description of Device (EUT)....................................................................................................................4
          1.2.      Description of Test Facility ......................................................................................................................4
          1.3.      Measurement Uncertainty.........................................................................................................................5
     2.      MEASURING DEVICE AND TEST EQUIPMENT ..................................................................... 6
     3.      SUMMARY OF TEST RESULTS................................................................................................... 7
     4.      FUNDAMENTAL AND HARMONICS RADIATED EMISSION FOR SECTION 15.249(A) 8
          4.1.      Block Diagram of Test Setup....................................................................................................................8
          4.2.      The Emission Limit ..................................................................................................................................9
          4.3.      Configuration of EUT on Measurement ...................................................................................................9
          4.4.      Operating Condition of EUT ....................................................................................................................9
          4.5.      Test Procedure ........................................................................................................................................10
          4.6.      The Field Strength of Radiation Emission Measurement Results ..........................................................11
     5.      SPURIOUS RADIATED EMISSION FOR SECTION 15.249(D) ............................................. 12
          5.1.      Block Diagram of Test Setup..................................................................................................................12
          5.2.      The Emission Limit For Section 15.249(d) ............................................................................................13
          5.3.      EUT Configuration on Measurement .....................................................................................................13
          5.4.      Operating Condition of EUT ..................................................................................................................13
          5.5.      Test Procedure ........................................................................................................................................14
          5.6.      The Emission Measurement Result ........................................................................................................15
     6.      BAND EDGES ................................................................................................................................. 16
          6.1.      The Requirement ....................................................................................................................................16
          6.2.      EUT Configuration on Measurement .....................................................................................................16
          6.3.      Operating Condition of EUT ..................................................................................................................16
          6.4.      Test Procedure ........................................................................................................................................16
          6.5.      The Measurement Result ........................................................................................................................17
     7.      ANTENNA REQUIREMENT........................................................................................................ 18
          7.1.      The Requirement ....................................................................................................................................18
          7.2.      Antenna Construction .............................................................................................................................18


    APPENDIX I ( TEST CURVES) (6 pages)




FCC ID: OMO-M-05                                                                               ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                                                    Page 3 of 25




                                      Test Report Certification

             Applicant          :   La Crosse Technology
             Manufacturer       :   Golden ESL Instrument (S.Z.) Co. Ltd.
             EUT Description    :   Rain Sensor
                                     (A) MODEL NO.: TX58U-IT
                                     (B) SERIAL NO.: N/A
                                     (C) POWER SUPPLY: 3V DC (“AA” batteries 2×)

             Measurement Procedure Used:

             FCC Rules and Regulations Part 15 Subpart C Section 15.249
             ANSI C63.4: 2003

             The device described above is tested by ACCURATE TECHNOLOGY CO. LTD to determine
             the maximum emission levels emanating from the device. The maximum emission levels are
             compared to the FCC Part 15 Subpart C Section15.249 limits. The measurement results are
             contained in this test report and ACCURATE TECHNOLOGY CO. LTD is assumed full
             responsibility for the accuracy and completeness of these measurements. Also, this report shows
             that the Equipment Under Test (EUT) is to be technically compliant with the FCC requirements.

             This report applies to above tested sample only. This report shall not be reproduced in part
             without written approval of ACCURATE TECHNOLOGY CO. LTD.

             Date of Test :                                     October 14-16, 2009


             Prepared by :


                                                                     (Engineer)


             Approved & Authorized Signer :

                                                                     (Manager)




FCC ID: OMO-M-05                                             ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                                                      Page 4 of 25




          1. GENERAL INFORMATION


                       1.1.Description of Device (EUT)
                     EUT                     :   Rain Sensor

                     Model Number            :   TX58U-IT

                     Power Supply            :   3V DC (“AA” batteries 2×)

                     Transmitting Frequency :    906MHz

                     Applicant               :   La Crosse Technology
                     Address                 :   2809 Losey Blvd. So. La Crosse WI 54601, USA

                     Manufacturer            :   Golden ESL Instrument (S.Z.) Co. Ltd.
                     Address                 :   Fu Yuan #2 Manufactory Building, 45 Area of Baoan
                                                 District, ShenZhen, China

                     Date of sample received :   October 13, 2009

                     Date of Test            :   October 14-16, 2009


                   1.2.Description of Test Facility
                     EMC Lab                 :   Accredited by TUV Rheinland Shenzhen

                                                 Listed by FCC
                                                 The Registration Number is 752051

                                                 Listed by Industry Canada
                                                 The Registration Number is 5077A-2

                                                 Accredited by China National Accreditation Committee
                                                 for Laboratories
                                                 The Certificate Registration Number is L3193

                     Name of Firm            :   ACCURATE TECHNOLOGY CO. LTD
                     Site Location           :   F1, Bldg. A, Changyuan New Material Port, Keyuan Rd.
                                                 Science & Industry Park, Nanshan, Shenzhen, Guangdong
                                                 P.R. China




FCC ID: OMO-M-05                                               ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                                                     Page 5 of 25




                   1.3.Measurement Uncertainty
                     Conducted Emission Expanded Uncertainty    =    2.23dB, k=2

                     Radiated emission expanded uncertainty     =    3.08dB, k=2
                     (9kHz-30MHz)

                     Radiated emission expanded uncertainty     =    4.42dB, k=2
                     (30MHz-1000MHz)

                     Radiated emission expanded uncertainty     =    4.06dB, k=2
                     (Above 1GHz)




FCC ID: OMO-M-05                                              ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                                                   Page 6 of 25




          2. MEASURING DEVICE AND TEST EQUIPMENT
               Table 1: List of Test and Measurement Equipment
                   Kind of equipment Manufacturer    Type              S/N               Calibrated until
                   EMI Test Receiver Rohde&Schwarz   ESCS30            100307            03.28.2010
                   EMI Test Receiver Rohde&Schwarz   ESPI3             101526/003        03.28.2010
                   Spectrum Analyzer Agilent         E7405A            MY45115511        03.28.2010
                   Pre-Amplifier     Rohde&Schwarz   CBLU118354 3791                     03.30.2010
                                                     0-01
                   Loop Antenna      Schwarzbeck     FMZB1516   1516131                  03.28.2010
                   Bilog Antenna     Schwarzbeck     VULB9163          9163-323          03.28.2010
                   Horn Antenna      Schwarzbeck     BBHA9120D         9120D-655         12.19.2009
                   Horn Antenna      Schwarzbeck     BBHA9170          9170-359          10.09.2010
                   LISN              Rohde&Schwarz   ESH3-Z5           100305            03.28.2010
                   LISN              Schwarzbeck     NSLK8126          8126431           03.28.2010




FCC ID: OMO-M-05                                            ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                                                    Page 7 of 25




          3. SUMMARY OF TEST RESULTS

                   FCC Rules           Description of Test                               Result
                   Section 15.207      Conducted Emission                                N/A
                   Section 15.249(a)   Fundamental and Harmonics Radiated Emission Compliant
                   Section 15.249(d)   Spurious Radiated Emission                        Compliant
                   Section 15.249(d)   Band Edge                                         Compliant
                   Section 15.203      Antenna Requirement                               Compliant

               Remark: “N/A” means “Not applicable”.




FCC ID: OMO-M-05                                             ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                                                   Page 8 of 25




          4. FUNDAMENTAL AND HARMONICS RADIATED EMISSION

               FOR SECTION 15.249(A)


                     4.1.Block Diagram of Test Setup
                       4.1.1.Block diagram of connection between the EUT and simulators

                                                 EUT

                                          (EUT: Rain Sensor)

                       4.1.2.Semi-Anechoic Chamber Test Setup Diagram

                                  ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS

                                                 3 METERS




                                                                          EUT

                   Cable
                                                                                    0.8 METER



                                 GROUND PLANE

                                          (EUT: Rain Sensor)




FCC ID: OMO-M-05                                            ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                                                   Page 9 of 25




                   4.2.The Emission Limit
                     4.2.1.For intentional radiators, According to section 15.249(a), Operation within the
                          frequency band of 902 to 928MHz, The fundamental field strength shall not
                          exceed 94 dBμV/m and the harmonics shall not exceed 54 dBμV/m.
                        Fundamental         Field Strength of Fundamental      Field Strength of harmonics
                         Frequency                 (millivolts/meter)               (microvolts/meter)
                        902-928MHz                         50                              500
                      2400-2483.5MHz                       50                              500
                       5725-5875MHz                        50                              500
                       24.0-24.25GHz                      250                             2500
                     4.2.2.According to section 15.249(e), as shown in section 15.35(b), the peak field
                          strength of any emission shall not exceed the maximum permitted average limits
                          specified above by more than 20 dB under any condition of modulation.


                   4.3.Configuration of EUT on Measurement
                   The following equipment are installed on Radiated Emission Measurement to meet the
                   commission requirements and operating regulations in a manner which tends to maximize
                   its emission characteristics in normal application.
                     4.3.1.Rain Sensor (EUT)
                          Model Number       :   TX58U-IT
                          Serial Number      :   N/A
                          Manufacturer       :   Golden ESL Instrument (S.Z.) Co. Ltd.


                   4.4.Operating Condition of EUT
                     4.4.1.Setup the EUT and simulator as shown as Section 4.1.

                     4.4.2.Turn on the power of all equipment.

                     4.4.3. Let the EUT work in TX mode measure it. The transmit frequency is 906MHz.




FCC ID: OMO-M-05                                            ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                                                  Page 10 of 25




                   4.5.Test Procedure
                   The EUT and its simulators are placed on a turntable, which is 0.8 meter high above
                   ground. The turntable can rotate 360 degrees to determine the position of the maximum
                   emission level. EUT is set 3.0 meters away from the receiving antenna, which is mounted
                   on an antenna tower. The antenna can be moved up and down between 1.0 meter and 4
                   meters to find out the maximum emission level. Broadband antenna (calibrated bilog
                   antenna) is used as receiving antenna. Both horizontal and vertical polarizations of the
                   antenna are set on measurement. In order to find the maximum emission levels, all of the
                   interface cables must be manipulated according to ANSI C63.4: 2003 on radiated
                   emission measurement.

                   The bandwidth of test receiver is set at 120kHz in 30-1000MHz. and set at 1MHz in
                   above 1000MHz.




FCC ID: OMO-M-05                                            ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                                                                      Page 11 of 25




                               4.6.The Field Strength of Radiation Emission Measurement Results
                               PASS.


        Date of Test:      October 14-16, 2009                      Temperature:       25oC
        EUT:               Rain Sensor                              Humidity:          50%
        Model No.:         TX58U-IT                                 Power Supply:      3V DC (“AA” batteries 2×)
        Test Mode:         TX 906MHz                                Test Engineer:     Joe


               Fundamental Radiated Emissions

Frequency      Reading(dBμV/m)         Factor(dB)    Result(dBμV/m) Limit(dBμV/m)                   Margin(dB)         Polarization

(MHz)            AV          PEAK      Corr.             AV     PEAK         AV       PEAK         AV       PEAK
905.9896        48.24         49.84      28.80        77.04      78.64        94        114      -16.96      -35.36    Vertical
905.9896        52.03         53.66      28.80        80.83      82.46        94        114      -13.17      -31.54    Horizontal


                Harmonics Radiated Emissions


Frequency      Reading(dBμV/m)         Factor(dB)    Result(dBμV/m) Limit(dBμV/m)                   Margin(dB)         Polarization

(MHz)            AV          PEAK      Corr.             AV     PEAK         AV       PEAK         AV       PEAK
1811.991        55.16         56.79       -9.92       45.24      46.87        54        74        -8.76      -27.13    Vertical
2717.983        50.19         55.16       -6.25       42.32      43.94        54        74       -11.68      -30.06    Vertical
4529.976        42.92         44.51       -1.25       41.67      43.26        54        74       -12.33      -30.74    Vertical
1811.991        51.66         53.29       -9.92       41.74      43.37        54        74       -12.26      -30.63    Horizontal
2717.983        50.43         52.32       -6.25       44.18      46.07        54        74        -9.82      -27.93    Horizontal
4529.976        45.56         47.13       -1.25       44.31      45.88        54        74        -9.69      -28.12    Horizontal


               Note:
               1. Emissions attenuated more than 20 dB below the permissible value are not reported.
               2. The field strength is calculated by adding the antenna factor, high pass filter loss(if used) and cable loss, and
                  subtracting the amplifier gain(if any)from the measured reading. The basic equation calculation is as follows:
                   Result = Reading + Corrected Factor
                   Where Corrected Factor = Antenna Factor + Cable Loss + High Pass Filter Loss – Amplifier Gain
               3. The spectral diagrams in appendix I display the measurement of peak values.




        FCC ID: OMO-M-05                                                     ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                                                  Page 12 of 25




          5. SPURIOUS RADIATED EMISSION FOR SECTION 15.249(D)


                     5.1.Block Diagram of Test Setup
                       5.1.1.Block diagram of connection between the EUT and simulators

                                             EUT

                                      (EUT: Rain Sensor)

                       5.1.2.Semi-Anechoic Chamber Test Setup Diagram


                                  ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS
                                                 3 METERS




                                                                         EUT

                   Cable
                                                                                    0.8 METER



                                 GROUND PLANE

                                      (EUT: Rain Sensor)




FCC ID: OMO-M-05                                            ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                                                  Page 13 of 25




                   5.2.The Emission Limit For Section 15.249(d)
                     5.2.1.Emission radiated outside of the specified frequency bands, except for harmonics,
                          shall be comply with the general radiated emission limits in Section 15.209.
                   Radiation Emission Measurement Limits According to Section 15.209
                                                                 Limit
                    Frequency         Field Strength of    Field Strength of The final measurement
                                      Quasi-peak Value     Quasi-peak Value        in band 9-90kHz,
                      (MHz)
                                       (microvolts/m)         (dBμV/m)              110-490kHz and
                                                                                  above 1000MHz is
                       30 - 88               100                  40                 performed with
                                                                                   Average detector.
                                                                                      Except those
                      88 - 216               150                 43.5               frequency bands
                                                                                  mention above, the
                                                                                final measurement for
                     216 - 960               200                  46
                                                                                  frequencies below
                                                                                       1000MHz is
                    Above 960                500                  54            performed with Quasi
                                                                                      Peak detector.


                   5.3.EUT Configuration on Measurement
                   The following equipment are installed on the Radiated Emission Measurement to meet
                   the commission requirements and operating regulations in a manner which tends to
                   maximize its emission characteristics in normal application.
                     5.3.1.Rain Sensor (EUT)
                          Model Number      :   TX58U-IT
                          Serial Number     :   N/A
                          Manufacturer      :   Golden ESL Instrument (S.Z.) Co. Ltd.


                   5.4.Operating Condition of EUT
                     5.4.1.Setup the EUT and simulator as shown as Section 5.1.

                     5.4.2.Turn on the power of all equipment.

                     5.4.3. Let the EUT work in TX mode measure it. The transmit frequency is 906MHz.




FCC ID: OMO-M-05                                            ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                                                  Page 14 of 25




                   5.5.Test Procedure
                   The EUT and its simulators are placed on a turntable, which is 0.8 meter high above
                   ground. The turntable can rotate 360 degrees to determine the position of the maximum
                   emission level. EUT is set 3.0 meters away from the receiving antenna, which is mounted
                   on an antenna tower. The antenna can be moved up and down between 1.0 meter and 4
                   meters to find out the maximum emission level. Broadband antenna (calibrated bilog
                   antenna) is used as receiving antenna. Both horizontal and vertical polarizations of the
                   antenna are set on measurement. In order to find the maximum emission levels, all of the
                   interface cables must be manipulated according to ANSI C63.4: 2003 on radiated
                   emission measurement.

                   The bandwidth of test receiver is set at 120kHz in 30-1000MHz. and set at 1MHz in
                   above 1000MHz.

                   The frequency range from 30MHz to 10000MHz is checked.

                   The final measurement in band 9-90kHz, 110-490kHz and above 1000MHz is performed
                   with Average detector. Except those frequency bands mention above, the final
                   measurement for frequencies below 1000MHz is performed with Quasi Peak detector.




FCC ID: OMO-M-05                                            ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                                                             Page 15 of 25




                      5.6.The Emission Measurement Result

                      PASS.


      Date of Test:   October 14-16, 2009                        Temperature:      25oC
      EUT:            Rain Sensor                                Humidity:         50%
      Model No.:      TX58U-IT                                   Power Supply:     3V DC (“AA” batteries 2×)
      Test Mode:      TX 906MHz                                  Test Engineer:    Joe


        Frequency        Reading       Factor(dB)         Result           Limit            Margin         Polarization
          (MHz)         (dBμV/m)          Corr.         (dBμV/m)         (dBμV/m)              (dB)
                            QP                              QP               QP                QP
               -              -             -                -                -                 -            Vertical
               -              -             -                -                -                 -          Horizontal


       Note:
       1. Emissions attenuated more than 20 dB below the permissible value are not reported.
       2. The field strength is calculated by adding the antenna factor, high pass filter loss(if used) and cable loss, and
          subtracting the amplifier gain(if any)from the measured reading. The basic equation calculation is as follows:
           Result = Reading + Corrected Factor
           Where Corrected Factor = Antenna Factor + Cable Loss + High Pass Filter Loss – Amplifier Gain
       3. The spectral diagrams in appendix I display the measurement of peak values.




FCC ID: OMO-M-05                                                     ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                                                  Page 16 of 25




          6. BAND EDGES


                   6.1.The Requirement
                     6.1.1.Band Edge from 902MHz to 928MHz. Emission radiated outside of the specified
                          frequency bands, except for harmonics, shall be attenuated by at least 50 dB
                          below the level of the fundamental or to the general radiated emission limits in
                          Section 15.209, whichever is the lesser attenuation.


                   6.2.EUT Configuration on Measurement
                   The following equipment are installed on the emission measurement to meet the
                   commission requirements and operating regulations in a manner which tends to maximize
                   its emission characteristics in normal application.
                     6.2.1.Rain Sensor (EUT)
                          Model Number       :   TX58U-IT
                          Serial Number      :   N/A
                          Manufacturer       :   Golden ESL Instrument (S.Z.) Co. Ltd.


                   6.3.Operating Condition of EUT
                     6.3.1.Setup the EUT and simulator as shown as Section 4.1.

                     6.3.2.Turn on the power of all equipment.

                     6.3.3. Let the EUT work in TX mode measure it. The transmit frequency is 906MHz.


                   6.4.Test Procedure
                   The EUT and its simulators are placed on a turntable, which is 0.8 meter high above
                   ground. The turntable can rotate 360 degrees to determine the position of the maximum
                   emission level. EUT is set 3.0 meters away from the receiving antenna, which is mounted
                   on an antenna tower. The antenna can be moved up and down between 1.0 meter and 4
                   meters to find out the maximum emission level. Broadband antenna (calibrated bilog
                   antenna) is used as receiving antenna. Both horizontal and vertical polarizations of the
                   antenna are set on measurement. In order to find the maximum emission levels, all of the
                   interface cables must be manipulated according to ANSI C63.4: 2003 on radiated
                   emission measurement.

                   The bandwidth of test receiver is set at 120kHz in 30-1000MHz. and set at 1MHz in
                   above 1000MHz.




FCC ID: OMO-M-05                                            ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                                                             Page 17 of 25




                      6.5.The Measurement Result

                      Pass.


      Date of Test:   October 15, 2009                           Temperature:      25oC
      EUT:            Rain Sensor                                Humidity:         50%
      Model No.:      TX58U-IT                                   Power Supply:     3V DC (“AA” batteries 2×)
      Test Mode:      TX 906MHz                                  Test Engineer:    Joe


        Frequency        Reading       Factor(dB)         Result           Limit            Margin         Polarization
          (MHz)         (dBμV/m)          Corr.         (dBμV/m)         (dBμV/m)              (dB)
                              QP                            QP               QP                QP
               -              -             -                -                -                 -            Vertical
               -              -             -                -                -                 -          Horizontal


       Note:
       1. Emissions attenuated more than 20 dB below the permissible value are not reported.
       2. The field strength is calculated by adding the antenna factor, high pass filter loss(if used) and cable loss, and
          subtracting the amplifier gain(if any)from the measured reading. The basic equation calculation is as follows:
           Result = Reading + Corrected Factor
           Where Corrected Factor = Antenna Factor + Cable Loss + High Pass Filter Loss – Amplifier Gain
       3. The spectral diagrams in appendix I display the measurement of peak values.




FCC ID: OMO-M-05                                                     ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                                                  Page 18 of 25




          7. ANTENNA REQUIREMENT


                   7.1.The Requirement
                     7.1.1.According to Section 15.203, an intentional radiator shall be designed to ensure
                          that no antenna other than that furnished by the responsible party shall be used
                          with the device.


                   7.2.Antenna Construction
                   Antenna is formed by a short copper wire soldered on the PCB, no consideration of
                   replacement.




                                                           Antenna




FCC ID: OMO-M-05                                            ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                                                                  Page 19 of 25




                   APPENDIX I
                   (Test Curves)




FCC ID: OMO-M-05            ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20091797


                             ACCURATE TECHNOLOGY CO., LTD.                                    Site: 966 chamber
                                 F1,B1dg A Changyuan New Material Port Keyuan R,           Tel+86—0755—20503200
                                 Scienso & Induatry Pork, Nanshan Shonzhon.P.R China       Emc «nsarse econaon
Job No: RTTE #3362                                                       Polariation: Horizontal
Standard: FCC lass B 3M Radiated                                         Power Source: DC 3V
Testitem: Radiaton Test                                                  Date:conorta
Temp( C)Hum(%) 25. C/50%                                                 Time: s8054
eur         Rain sensor                                                  Engineer Signature: Joo
Mode: TX                                                                 Distance: 3m
Model: Txseu—i
Manufactirer: La Crosse Technology
Note:      Sample No—092074.       Report No—ATE20001797

     sos    wtts

     «o
     m
     «o
     m
     «
     s
     m
     10
     s
          sn o          smm c                                 "        Sn Sor sai m yontd uie
            Frea        Reading Factor         Result      |—Timt.—Marg] . . |rean| Sepee
"*          (uo)        Geuvim)       (48)_|   (@Bavim) |asuvim] (ae) P07 &m ce |                  *
i           s0s Sos0|     £365        28 80     824        11400    |—3164 peak
2           s0s s0s0|     £203        28 80     s083       si00     1317 Ave


                             ACCURATE TECHNOLOGY CO., LTD.                                     Site: 966 chamber
                                F1,B1dg A Changyuan New Material Port Keyuan R,             Tel+86—0755—20503200
                                Scienso & Induatry Pork, Nanshan Shonzhon.P.R China         Emc «nsarse econaon
Job No: RTTE#2361                                                         Polariation: Verical
Standard: FCC lass B 3M Radiated                                          Power Source: DC 3V
Testitem: Radiaton Test                                                   Date:conorta
Temp( C)Hum(%) 25. C/50%                                                  Time: 9551
eur         Rain sensor                                                   Engineer Signature: Joo
Mode: TX                                                                  Distance: 3m
Model: Txseu—i
Manufactirer: La Crosse Technology
Note: Sample No—092074. Report No—ATE20001797

     sos    wtts
                                                                                            sm~=z
     «o
     m
     «o
     m
     «
     s
     m
     10
     s
          sn o          smm c                                "        Sn Sor sai m yonrd uie
            Frea        Reading Factor        Result      |—Timt.—Marg] . . |rean| Sepee
"*          (uo)        Geuvim)      (48)_|   (@Bavim) |asuvim] (ae) P07 &m ce |                    *
i           50s 5030|    4984        28 80     7664       11400    |—35.34.   peak
2           s05 s000|    4824        28 80     7704       si00     1680       Avo


                               ACCURATE TECHNOLOGY CO., LTD.                                                Site: 968 chamber
                                  F1,1daAChangyuan New Material Port Keyuan R.,                          Te»as—075s—20503200
                                  Seianco & Induatry Pork, Nanshan Shonzhon.P.R China                    Fmcens.arse.ascoramn
Job No:      RTTE #2374                                                         Polarization:        Horizontal
Standard:    FCC Class B 3M Radiated                                            Power Source:         DC 3V
Testitem:      Radiaton Test                                                    Date: 090E
Temp(        C)Hum(%) 25. C/50%                                                 Time:92128
eut           Rain sensor                                                       Engineer Signature:         Joo
Mode:        TX                                                                 Distance:       3m
Mode!        Txs8u—it
Manutacturer: La Crosse Technology
Note:       Sample No:092074         Report No—ATE20091797



     Ts watts
                                                                                                          z—=
     w                                                               i              femaipendcafan
     so
     in
     m
     m
     10
     s                                                              ;                ;    ;
      nmroce                             zn                         on             snn on on sen
             Frea         Reading      Factor     Result     |—Timt.—Marg]            ..    |rean| Sepee
Ne          z)            (dBuvim)     |_(@@)_|   (Buvim) |raewvim)| (e) P47 en c |                               *
i            1611 991]—    5329        492         4337      7400   |3063]         peak
2            w611991]—     se          492         4178      £100   |—1220]        Avo
3            27803         $232        425         46 07     7400   |—2793]        peak
a            27883|        £043        $25         4418      5100    $62|          AVG
5            4520970)      47.3        425         4585      7400   |—28 12]       peak
6            4520970)      4555        4125        4431      5100        S63|      AVG


                               ACCURATE TECHNOLOGY CO., LTD.                                           Site: 968 chamber
                                  F1,1daAChangyuan New Material Port Keyuan R.,                     Te»as—075s—20503200
                                  Seianco & Induatry Pork, Nanshan Shonzhon.P.R China               Fmcens.arse.ascoramn
Job No:      RTTE#2373                                                     Polarization:        Verical
Standard:    FCC Class B 3M Radiated                                       Power Source:         DC 3V
Testitem:      Radiaton Test                                               Date: 090E
Temp(        C)Hum(%) 25. C/50%                                            Time: 9188
eut           Rain sensor                                                  Engineer Signature:            Joo
Mode:        TX                                                            Distance:       3m
Mode!        Txs8u—it
Manutacturer: La Crosse Technology
Note:       Sample No:092074         Report No—ATE20091797



     Ts watts
                                                                                                     z—=
     w                                                               i         femaipendcafan
     so
     in                                                                                    TiA                  fad
     »                                                                                     fafiond                  —

     m                                                                                 ofonsnefommcducd
     10
     snmroce                             zn                         i
                                                                    on           ols
                                                                               smm —mas on sen
             Frea         Reading      Factor     Result     |—Timt.—Marg]       ..    |rean| Sepee
Ne          z)            (dBuvim)     |_(@@)_|   (Buvim) |raewvim)| (e) P47 en c |                             *
i            1611 991]—    5679        492         4687      7400   |—27.13]   peak
2            w611 991]     5516        492         45 24     5100    476|      AVG
3            278635019                 425         4391      7400   |3006]     peak
a            277863 4857               $25         4237      si00   |—i68]     Avo
5            4520970]      4451        425         4326      7400   |—30.74)   peak
6            4520970       4282        4125        4167      s100   |—41233]   Ave


                        ACCURATE TECHNOLOGY CO., LTD.                                Site: 968 chamber
                        F1,1daAChangyuan New Material Port Keyuan R.,            Te»as—075s—20503200
                        Seianco & Induatry Pork, Nanshan Shonzhon.P.R China       Fmcens.arse.ascoramn
Job No: rTTE #a3ce                                               Polariation Horizonta
Standard: FCC Band Edge                                          Power Source beav
Testitem: Raclation Test                                         Date: coronst
Temp( C)Hum(%) 25. C750 %                                        Time: 101605
eur         Rain sensor                                          Engineer Signature: Joo
Mode: TX                                                         Distance
Model: Txseu—i
Manufactirer: La Crosse Technology
Note: Sample No—092074. Report No—ATE20001797

     rou0_warre
                                                                                   Ex
     u...         /ssossmsytyy_y__                                                 Ei
     10e
     so




     mo
      sorms                                                                                w ue
           Freq    Readng     Faclor   Resut      |—limt—   Margn|   o2. ,   [rean| o
"*         (uko    Geuvim)    (48)_|   @Bavim) asovim] ae) |P7| on ce |*


                        ACCURATE TECHNOLOGY CO., LTD.                                 Site: 968 chamber
                        F1,1daAChangyuan New Material Port Keyuan R.,             Te»as—075s—20503200
                        Seianco & Induatry Pork, Nanshan Shonzhon.P.R China        Fmcens.arse.ascoramn
Job No: rtre aasor                                               Polariation Vertical
Standard: FCC Band Edge                                          Power Source beav
Testitem: Raclation Test                                         Date: coronst
Temp( C)Hum(%) 25. C750 %                                        Time: 10/11/14
eur         Rain sensor                                          Engineer Signature: Joo
Mode: TX                                                         Distance: 3m
Model: Txseu—i
Manufactirer: La Crosse Technology
Note: Sample No—092074. Report No—ATE20001797

     rou0_warre
                Ex
     w     | uen
     10e
     so




     mo
      sorms                                                                                w ue
           Freq    Readng     Faclor    Resut     |—limt—   Margn|   o2. ,   [rean| o
"*         (uko    Geuvim)     (48)_|   @Bavim) asovim] ae) |P7| on ce |*



Document Created: 2009-11-09 17:33:34