Tune up

FCC ID: OJYKAG9

Parts List/Tune Up Info

Download: PDF
FCCID_272569

                                                                      OJYKAG9



                      Alignment/Tune-Up Procedure

The RF Calibration table is an array of values which represent what the RBS1127 power
sensor sees at a given output power level. This table is used for controlling the
RBS1127's transmit power. The table's array elements are 0.5 dBm apart. Each
element is a set point for a given power level. The software periodically reads the
power sensor and slews the output power level towards a particular set point. For
example, if the user configures the RBS1127 so that its transmit power is 43.0 dBm, the
RBS1127 will adjust the output power so that the power sensor reading is within range
of the 43.0 dBm set point.



Document Created: 2002-09-25 12:02:32
Document Modified: 2002-09-25 12:02:32

© 2024 FCC.report