RF Exposure Info (MPE)

FCC ID: OGSUTM300

RF Exposure Info

Download: PDF
FCCID_4351474

                                                           RF Exposure Report

                       Report No.: SA190515C01

                            FCC ID: OGSUTM300

                       Test Model: UTM-300 UHF RFID Reader Module

                 Received Date: May 15, 2019

                         Test Date: May 18 ~ Jun. 17, 2019

                     Issued Date: Jun. 20, 2019


                         Applicant: Applied Wireless Identifications (AWID) Group Inc.

                           Address: 18300 Sutter Blvd. Morgan Hill, CA, 95037, USA


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
                                 (R.O.C.)
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to
us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such
notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your
unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the
uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.


Report No.: SA190515C01                                               Page No. 1 / 5                                             Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
3         Calculation Result of Maximum Conducted Power........................................................................... 5




Report No.: SA190515C01                                              Page No. 2 / 5                                              Report Format Version: 6.1.1


                                          Release Control Record


Issue No.             Description                                         Date Issued
SA190515C01           Original release.                                   Jun. 20, 2019




Report No.: SA190515C01                      Page No. 3 / 5        Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: UTM-300 UHF RFID Reader Module

              Brand: AWID

        Test Model: UTM-300 UHF RFID Reader Module

    Sample Status: Engineering sample

          Applicant: Applied Wireless Identifications (AWID) Group Inc.

          Test Date: May 18 ~ Jun. 17, 2019

         Standards: FCC Part 2 (Section 2.1093)
                          KDB 447498 D01 General RF Exposure Guidance v06
                          IEEE C95.3 -2002



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                              , Date:         Jun. 20, 2019
                                 Polly Chien / Specialist




     Approved by :                                               , Date:         Jun. 20, 2019
                             Bruce Chen / Project Engineer




Report No.: SA190515C01                         Page No. 4 / 5                        Report Format Version: 6.1.1


2      RF Exposure

2.1     Limits for Maximum Permissible Exposure (MPE)

    Frequency Range          Electric Field      Magnetic Field             Power Density         Average Time
    (MHz)                   Strength (V/m)       Strength (A/m)               (mW/cm2)              (minutes)
                              Limits For General Population / Uncontrolled Exposure
        0.3-1.34                 614                   1.63                    (100)*                    30
        1.34-30                 824/f                 2.19/f                  (180/f2)*                  30
        30-300                   27.5                 0.073                      0.2                     30
       300-1500                   …                     …                      f/1500                    30
      1500-100,000                …                     …                        1.0                     30

f = Frequency in MHz ; *Plane-wave equivalent power density


2.2     MPE Calculation Formula

Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm


2.3     Classification

The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So,
this device is classified as Mobile Device.


3      Calculation Result of Maximum Conducted Power
Frequency Band            Max Power      Antenna Gain            Distance        Power Density           Limit
    (MHz)                   (dBm)            (dBi)                 (cm)            (mW/cm2)            (mW/cm2)
 902.6 ~ 927.4              27.98             5.8                   20               0.475               0.602
Note: Determining compliance based on the results of the compliance measurement, not taking into account
measurement instrumentation uncertainty.




---END---




Report No.: SA190515C01                         Page No. 5 / 5                              Report Format Version: 6.1.1



Document Created: 2019-07-11 11:52:37
Document Modified: 2019-07-11 11:52:37

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC