MPE Calculation

FCC ID: ODL-AC-21C

RF Exposure Info

Download: PDF
FCCID_4054408

                        FCC ID : ODL-AC-21C

  1. RF EXPOSURE

  1.1.The Requirement

            System operating under the provisions of this section shall be operated in a manner
            that ensures that the public is not exposed to radio frequency energy levels in excess
            of the Commission’s guidelines. See Section 15.247(b)(4) and Section 1.1307(b)(1)


  1.2.Limit For Maximum Permissible Exposure (MPE)

       Limits for General Population/ Uncontrolled Exposure
                                                            Power Density     Averaging Time
   Frequency         Electric Field     Magnetic Field
                                                                (S)                2        2
     Range           Strength (E)        Strength (H)                            E ,H           or S
                                                                         2
     (MHz)              (V/m)               (A/m)            ( mW/cm )
                                                                                   (minutes)
    0.3-1.34              614                1.63               (100)*               30
     1.34-30             824/f              2.19/f             (180/f)*                30
     30-300               27.5               0.073                0.2                  30
    300-1500                                                    f/1500                 30
  1500-100,000                                                    1.0                  30

F = frequency in MHz,     * Plane-wave equivalent power density


  1.3.MPE Calculation Method
         Predication of MPE limit at a given distance
         Equation from page 18 of OET Bulletin 65, Edition 97-01

         S=PG/4πR²
         Where: S=power density
                 P=power input to antenna
                G=power gain of the antenna in the direction of interest relative to an isotropic
                radiator
                 R=distance to the center of radiation of the antenna

         From the peak EUT RF output power, the minimum mobile separation distance,
         d=0.2m, as well as the gain of the antenna is 2dBi, the RF power density can be
         obtained.


   1.4.TEST RESULTS
        Maximum measured transmitter power

        8DPSK

   Test   Minimum               Target     Target                  Power    Power
                     Output                           Antenna
Frequency Separation            power      power                  Density  Density  Test
                     Power                             Gain
           Distance             (dBm)      (mW)                   At 20 cm  Limit  Results
(MHz)                (dBm)                           (Numeric)
            (cm)                                                 (mW/cm2) (mW/cm2)
  2441      20.00     2.88       3 ±1      2.512       1.585       0.0008   1.000   Pass

        The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the
        uncontrolled RF Exposure.



   1.5.FCC Radiation Exposure Statement
        This equipment complies with FCC radiation exposure limits set forth for an
        uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio
        frequency exposure limits, Human proximity to the antenna shall not be less than
        20cm(8 inches) during normal operation. Proposed RF exposure safety information to
        include in User’s Manual.



Document Created: 2018-10-30 11:00:12
Document Modified: 2018-10-30 11:00:12

© 2024 FCC.report