MPE estimation

FCC ID: OAYSRR5B

RF Exposure Info

Download: PDF
FCCID_4135294

                                                                                                                       D-PL-12076-01-03




                        Maximum Permissible Exposure (MPE) &
                                            Exposure evaluation


                               Report identification number: 1-6030/18-01-12

                                   Certification numbers and labeling requirements
 FCC ID                                                             OAYSRR5B
 IC number                                                          4135A-SRR5B
 HVIN (Hardware Version Identification Number)                      SRR5-B
 PMN (Product Marketing Name)                                       SRR520V1
 FVIN (Firmware Version Identification Number)                      RHC_11.00.10
 HMN (Host Marketing Name)                                          -/-

This test report is electronically signed and valid without handwriting signature. For verification of the electronic signatures,
the public keys can be requested at the testing laboratory.


                                                                  Document authorized:
                                                                                                  DN: cn=Thomas Vogler, o=CTC advanced
                                                                                                  GmbH, ou=VOG-161125,
                                                                                                  email=thomas.vogler@ctcadvanced.com,
                                                                                                  c=DE
                                                                                                  Datum: 2018.11.21 12:22:31 +01'00'

                                                                  Thomas Vogler
                                                                  Lab Manager
                                                                  Radio Communications & EMC




                                                         Page 1 of 3


EUT technologies:

                                Technologies:        Applied averaged EIRP (P*G)
                                 76 - 77 GHz                   24.5 dBm


Prediction of MPE limit at given distance - FCC

Equation from page 18 of OET Bulletin 65, Edition 97-01

S = PG / 4π R2

where: S = Power density
       P = Power input to the antenna
       G = Antenna gain
       R = Distance to the center of radiation of the antenna

The table below is excerpted from Table 1B of 47 CFR 1.1310 titled “Limits for Maximum Permissible Exposure
(MPE), Limits for General Population/Uncontrolled Exposure”

     Frequency Range (MHz)                Power Density (mW/cm2)                  Averaging Time (minutes)
           300 -1500                              f/1500                                     30
         1500 - 100000                              1.0                                      30

where f = Frequency (MHz)


Prediction: worst case

                                                                > 1500   MHz
    Technology - Radar                                              77   GHz
P Applied averaged EIRP (P*G)                                     24.5   dBm
R Distance                                                          20   cm
S MPE limit for uncontrolled exposure                                1   mW/cm2
    Calculated Power density:                                   0.0561   mW/cm²
This prediction demonstrates the following:

The power density levels for FCC at a distance of 20 cm are below the maximum levels allowed by regulations.




                                                 Page 2 of 3


Prediction of MPE limit at given distance - IC

RSS-102, Issue 5, 2.5.2

RF exposure evaluation is required if the separation distance between the user and/or bystander and the
device’s radiating element is greater than 20 cm, except when the device operates as follows:
        • below 20 MHz and the source-based, time-averaged maximum e.i.r.p. of the device is equal to or less
        than 1 W (adjusted for tune-up tolerance);
        • at or above 20 MHz and below 48 MHz and the source-based, time-averaged maximum e.i.r.p. of the
        device is equal to or less than 4.49/ƒ0.5W (adjusted for tune-up tolerance), where ƒ is in MHz;
        • at or above 48 MHz and below 300 MHz and the source-based, time-averaged maximum e.i.r.p. of the
        device is equal to or less than 0.6 W (adjusted for tune-up tolerance);
        • at or above 300 MHz and below 6 GHz and the source-based, time-averaged maximum e.i.r.p. of the
        device is equal to or less than 1.31 x 10-2 ƒ0.6834 W (adjusted for tune-up tolerance), where ƒ is in MHz;
        • at or above 6 GHz and the source-based, time-averaged maximum e.i.r.p. of the device is equal to or
        less than 5 W (adjusted for tune-up tolerance).


Prediction: worst case

                                                         above 6   GHz
    Technology - Radar                                        77   GHz
P   Applied averaged EIRP (P*G)                             24.5   dBm
R   Distance                                                  20   cm
    Maximum EIRP                                           281.8   mW
    Exclusion Limit from above:                             5.00   W

Conclusion: RF exposure evaluation is not required.
            For applications where minimum distance to radiating element is 20cm Annex C of RSS-102
            should be filled out.




                                                  Page 3 of 3



Document Created: 2018-11-21 12:22:31
Document Modified: 2018-11-21 12:22:31

© 2024 FCC.report