Exhibit 6 Test report 2

FCC ID: OAYARS2-C

Test Report

Download: PDF
FCCID_372583

   EMCC                                                                                      Page 1 of 17

   ~ DR. RASEK

                       TEST REPORT # EMCC—980162IDAA, 2003—JUN—18


 EQUIPMENT UNDER TEST:
     Type:                                  ARS 2—C
     Serial Number:                         1103070007
     Equipment Category:                    Part 15 Forward—Looking Field Disturbance Sensor, Vehicle
                                            Radar System

     Manufacturer:                          Conti Temic GmbH
     Address:                               Sieboldstrasse 19
                                            90411 NUurnberg
                                            Germany
     Phone:                                 +49—911—9526—2100
     Fax:                                   +49—911—9526—2354

     Applicant:                             A.D.C. Automotive Distance Control Systems GmbH
     Address:                               Kemptener Strasse 99
                                            88131 Lindau (Bodensee)
                                            Germany
     Phone:                                 +49—8382—9699—0
     Fax:                                   +49—8382—9699—19


 RELEVANT STANDARD:                         47 CFR Part 15C — Intentional Radiators, §15.253
                                            Spurious Emissions, only

 MEASUREMENT PROCEDURE USED:

     [] aAnist C63.4—1992            [] FCC/OoET MP—4 (1987)           [X] IEEE Std C95.3—1991


 TEST REPORT PREPARED BY:
     Reinhard Sauerschell                         EMCC DR. RASEK
     E—mail: r.sauerschell@emcc.de                Moggast 72—74
     Phone: +49 9194 9016                         91320 Ebermannstadt
     Fax: +49 9194 8125                           Germany


 TEST PERSONNEL:                                     HEAD OF LABORATORY:




     Reinhard Sauerschell                              Winfried Hoffmann


EMCC DR. RASEK                            RADIO LABORATORIES                 Telephone:       +49—9194—9016
Moggast 72—74                              EMC LABORATORIES                  Telefax:         +49—9194—8125
91320 Ebermannstadt                                poowei                    Mail:        emc.cons@emecc.de
Germany                                             2 C3                     Web:         http://www.emcc.de

FCC Registration # 90566                     TTI—P—G 094/94
                                             TTI—P—G 074795
ARS 2 C_FCC_IDAA.doc


                                                                                                                                Test Report #EMCC-980162IDAA
                                                                                                                                                   Page 2 of 17
                                                                                                                                       Issue Date: 2003-JUN-18


                                        Test of Conti Temic GmbH Type ARS 2-C, Serial number 1103070007
                                                 to 47 CFR Part 15C - Intentional Radiators, §15.253


CONTENTS                                                                                                                                                                                    Page


1   GENERAL INFORMATION ...................................................................................................................................................................3
    1.1   Purpose..................................................................................................................................................................................3
    1.2   Limits and Reservations ......................................................................................................................................................3
    1.3   Test Location.........................................................................................................................................................................3
    1.4   Manufacturer .........................................................................................................................................................................3
    1.5   Applicant................................................................................................................................................................................4
    1.6   Dates ......................................................................................................................................................................................4
2   Product Description.............................................................................................................................................................................5
    2.1     Equipment Under Test (EUT)...............................................................................................................................................5
    2.2     EUT Peripherals ....................................................................................................................................................................5
    2.3     Mode of Operation During Testing .....................................................................................................................................5
    2.4     Modifications Required for Compliance ............................................................................................................................5
3   Test Results Summary ........................................................................................................................................................................6
4   Radiated Emissions .............................................................................................................................................................................7
    4.1      Regulation .............................................................................................................................................................................7
    4.2      Radiated Emissions Test, up to 26.5 GHz .........................................................................................................................9
        4.2.1    Test Equipment .............................................................................................................................................................9
        4.2.2    Test Procedures ............................................................................................................................................................9
        4.2.3    Calculation of Field Strength Limits .........................................................................................................................10
        4.2.4    Average Correction Factor.........................................................................................................................................10
        4.2.5    Field Strength Calculation .........................................................................................................................................10
        4.2.6    Test Results.................................................................................................................................................................11
    4.3      Radiated Emissions Test, 26.5 GHz to 231 GHz (outside the operating band)...........................................................12
        4.3.1    Test Equipment ...........................................................................................................................................................12
        4.3.2    Test Procedures ..........................................................................................................................................................13
        4.3.3    Calculations of Spurious Emissions Limits.............................................................................................................13
        4.3.4    Field Strength Calculation .........................................................................................................................................14
        4.3.5    Power Density Calculation.........................................................................................................................................15
        4.3.6    Test Results.................................................................................................................................................................15
5   Miscellaneous Comments and Notes ..............................................................................................................................................17
6   List of ANNEXES ................................................................................................................................................................................17




ARS 2 C_FCC_IDAA.DOC


                                                                      Test Report #EMCC-980162IDAA
                                                                                         Page 3 of 17
                                                                             Issue Date: 2003-JUN-18


                       Test of Conti Temic GmbH Type ARS 2-C, Serial number 1103070007
                                to 47 CFR Part 15C - Intentional Radiators, §15.253




1 GENERAL INFORMATION

1.1 Purpose
The purpose of this report is to show compliance to the FCC regulations for devices operating under
section 15.253 of the Code of Federal Regulations title 47.



1.2 Limits and Reservations
The test results in this report apply only to the particular Equipment Under Test (EUT) as declared in this
report.
This test report shall not be reproduced except in full without the written permission of EMCC DR.
RAŠEK.



1.3 Test Location
Company Name:             EMCC DR. RAŠEK
Street:                   Moggast 72-74
City:                     91320 Ebermannstadt
Country:                  Germany
Laboratory:               Test Laboratory of EMCC DR. RAŠEK
                          FCC Registration Number: 90566
                          This site has been fully described in a report submitted to the FCC, and
                          accepted in the letter dated February 09, 2000 Registration Number 90566.
Phone:                    +49-9194-9016
Fax:                      +49-9194-8125
E-Mail:                   emc.cons@emcc.de
Web:                      www.emcc.de



1.4 Manufacturer
Company Name:             Conti Temic GmbH
Street:                   Sieboldstrasse 19
City:                     90411 Nürnberg
Country:                  Germany
Phone:                    +49-911-9526-2100
Fax:                      +49-911-9526-2354




ARS 2 C_FCC_IDAA.DOC


                                                                      Test Report #EMCC-980162IDAA
                                                                                         Page 4 of 17
                                                                             Issue Date: 2003-JUN-18


                       Test of Conti Temic GmbH Type ARS 2-C, Serial number 1103070007
                                to 47 CFR Part 15C - Intentional Radiators, §15.253



1.5 Applicant
Company Name:           A.D.C. Automotive Distance Control Systems GmbH
Street:                 Kemptener Strasse 99
City:                   88131 Lindau (Bodensee)
Country:                Germany
Name for contact purposes:     Mr Peter Glocker
Phone:                  +49-8382-9699-62
Fax:                    +49-8382-9699-94
E-mail:                 peter.glocker@adc-gmbh.de



1.6 Dates
Date of receipt of EUT:   CW 18/2003
Test date:                CW 25/2003




ARS 2 C_FCC_IDAA.DOC


                                                                                  Test Report #EMCC-980162IDAA
                                                                                                     Page 5 of 17
                                                                                         Issue Date: 2003-JUN-18


                            Test of Conti Temic GmbH Type ARS 2-C, Serial number 1103070007
                                     to 47 CFR Part 15C - Intentional Radiators, §15.253




2 PRODUCT DESCRIPTION

2.1 Equipment Under Test (EUT)

Description:                     Adaptive Cruise Control Pulse Doppler RADAR System
Device designation:              Part 15 Forward-Looking Field Disturbance Sensor, Vehicle Radar System
Type:                            ARS 2-C 1
No. of units:                    one
Serial number:                   1103070007

Transmit Frequency:       76 to 77 GHz
Type of modulation:       Pulse Doppler
Pulse repetition frequency: 286 to 667 kHz
Pulse width:              33 ns

Class of emission (ITU):         50M0 P0N
Measurement distance:            1 to 150 m
RF power:                        200 µW average nominal
Antenna:                         Integral
Rated input voltage:             12.0 VDC nominal


2.2 EUT Peripherals
The EUT was tested as stand alone unit
- with supplied cable bundle (CAN-bus matched with resistors),
- with automatic power on feature: after power on the unit turned to normal operation mode (in motion
  mode) by itself,
- with standard lead acid vehicle battery 12 VDC and standard laboratory DC power supply as back up.


2.3 Mode of Operation During Testing
The equipment under test (EUT) was operated during the tests under the the following condition:
   - in motion mode (unit was prepared by applicant in that way, that unit turned to in motion mode by
      itself after power on).


2.4 Modifications Required for Compliance
None




1
    The ARS 2-C is a variant of the ARS 2-A as full tested according to test report EMCC-980162IAA, 2003-FEB-06.
ARS 2 C_FCC_IDAA.DOC


                                                                      Test Report #EMCC-980162IDAA
                                                                                         Page 6 of 17
                                                                             Issue Date: 2003-JUN-18


                       Test of Conti Temic GmbH Type ARS 2-C, Serial number 1103070007
                                to 47 CFR Part 15C - Intentional Radiators, §15.253




3 TEST RESULTS SUMMARY

Summary of Test Results

Requirement                                CFR Section              Report Section       Test Result
Antenna Requirement                        15.203                                        not tested
Conducted Emissions                        15.207                                        n.a.
Radiated Spurious Emissions                15.209, 15.253(c)                             Pass
Power Density Limits (Fundamental)         15.253(b)                                     not tested
Operation within the band, 20 dB           15.253(e), 15.215(c)                          not tested
bandwidth, frequency stability
Radio frequency exposure                   15.253(f)                                     not tested


NOTE: "not tested" parameters on applicants request. The ARS 2-C is a variant of the ARS 2-A as
full tested according to test report EMCC-980162IAA, 2003-FEB-06.

The client has made the determination that EUT Condition, Characterization, and Mode of Operation are
representative of production units, and meet the requirements of the specifications referenced herein.

Consistent with Industry practice, measurement and test equipment not directly involved in obtaining
measurement results but having an impact on measurements (such as cable loss, antenna factors, etc.)
are factored into the "Correction Factor" documented in certain test results. Instrumentation employed
for testing meets tolerances consistent with known Industry Standards and Regulations.

The measurements contained in this report were made in accordance with the procedure ANSI C63.4 -
1992 and IEEE Std C95.3-1991. All requirements were found to be within the limits outlined in this
report.
The test results in this report apply only to the particular Equipment Under Test (EUT) as declared in this
report.

Test Personnel: Reinhard Sauerschell
Issuance Date: 2003-06-18




ARS 2 C_FCC_IDAA.DOC


                                                                      Test Report #EMCC-980162IDAA
                                                                                         Page 7 of 17
                                                                             Issue Date: 2003-JUN-18


                       Test of Conti Temic GmbH Type ARS 2-C, Serial number 1103070007
                                to 47 CFR Part 15C - Intentional Radiators, §15.253




4 RADIATED EMISSIONS
Test Requirement: FCC CFR47, Part 15C
Test Procedure: ANSI C63.4:1992

4.1 Regulation

Section 15.253 Operation within the bands 46.7-46.9 GHz and 76.0-77.0 GHz.
(a) Operation within the bands 46.7-46.9 GHz and 76.0-77.0 GHz is restricted to vehicle-mounted field
disturbance sensors used as vehicle radar systems. The transmission of additional information, such as
data, is permitted provided the primary mode of operation is as a vehicle-mounted field disturbance
sensor. Operation under the provisions of this section is not permitted on aircraft or satellites.
(b) The radiated emission limits within the bands 46.7-46.9 GHz and 76.0-77.0 GHz are as follows:
(1) If the vehicle is not in motion, the power density of any emission within the bands specified in this
section shall not exceed 200 nW/cm² at a distance of 3 meters from the exterior surface of the radiating
structure.
(2) For forward-looking vehicle-mounted field disturbance sensors, if the vehicle is in motion the power
density of any emission within the bands specified in this section shall not exceed 60 µW/cm² at a
distance of 3 meters from the exterior surface of the radiating structure.
(c) The power density of any emissions outside the operating band shall consist solely of spurious
emissions and shall not exceed the following:
(1) Radiated emissions below 40 GHz shall not exceed the general limits in Section 15.209 of this part.
(2) Radiated emissions outside the operating band and between 40 GHz and 200 GHz shall not exceed
the following:
(ii) For forward-looking vehicle-mounted field disturbance sensors operating in the band 76-77 GHz: 600
pW/cm² at a distance of 3 meters from the exterior surface of the radiating structure.
(3) For radiated emissions above 200 GHz from field disturbance sensors operating in the 76-77 GHz
band: the power density of any emission shall not exceed 1000 pW/cm² at a distance of 3 meters from
the exterior surface of the radiating structure.
(4) For field disturbance sensors operating in the 76-77 GHz band, the spectrum shall be investigated up
to 231 GHz.
(d) The provisions in Section 15.35 of this part limiting peak emissions apply.
(e) Fundamental emissions must be contained within the frequency bands specified in this section during
all conditions of operation. Equipment is presumed to operate over the temperature range -20 to +50
degrees Celsius with an input voltage variation of 85% to 115% of rated input voltage, unless justification
is presented to demonstrate otherwise.




ARS 2 C_FCC_IDAA.DOC


                                                                        Test Report #EMCC-980162IDAA
                                                                                           Page 8 of 17
                                                                               Issue Date: 2003-JUN-18


                       Test of Conti Temic GmbH Type ARS 2-C, Serial number 1103070007
                                to 47 CFR Part 15C - Intentional Radiators, §15.253



Section 15.35 Measurement detector functions and bandwidths.
(b) On any frequency of frequencies above 1000 MHz, the radiated limits shown are based upon the use
of measurement instrumentation employing an average detector function. When average radiated
emission measurements are specified in the regulations, including emission measurements below 1000
MHz, there is also a limit on the radio frequency emissions, as measured using instrumentation with a
peak detector function, corresponding to 20 dB above the maximum permitted average limit for the
frequency being investigated unless a different peak emission limit is otherwise specified in the rules in
this part, e.g., see § 15.255. Unless otherwise specified, measurements above 1000 MHz shall be
performed using a minimum resolution bandwidth of 1 MHz. Measurement of AC power line conducted
emissions are performed using a CISPR quasipeak detector, even for devices for which average
radiated emission measurements are specified.

Section 15.209 (a) Except as provided elsewhere in this subpart, the emissions from an intentional
radiator shall not exceed the field strength levels specified in the following table:

Frequency                       Field Strength                     Measurement distance
(MHz)                           (microvolts/meter)                 (meters)
0.009–0.490                     2400/F(kHz)                        300
0.490–1.705                     24000/F(kHz)                       30
1.705–30.0                      30                                 30
30–88                           100                                3
88–216                          150                                3
216–960                         200                                3
Above 960                       500                                3

(b) In the emission table above, the tighter limit applies at the band edges.

(c) The level of any unwanted emissions from an intentional radiator operating under these general
provisions shall not exceed the level of the fundamental emission. For intentional radiators which operate
under the provisions of other sections within this part and which are required to reduce their unwanted
emissions to the limits specified in this table, the limits in this table are based on the frequency of the
unwanted emission and not the fundamental frequency. However, the level of any unwanted emissions
shall not exceed the level of the fundamental frequency.

(d) The emission limits shown in the above table are based on measurements employing a CISPR quasi
peak detector except for the frequency bands 9–90 kHz, 110–490 kHz and above 1000 MHz. Radiated
emission limits in these three bands are based on measurements employing an average detector.
(e) The provisions in §§ 15.31, 15.33, and 15.35 for measuring emissions at distances other than the
distances specified in the above table, determining the frequency range over which radiated emissions
are to be measured, and limiting peak emissions apply to all devices operated under this part.




ARS 2 C_FCC_IDAA.DOC


                                                                                    Test Report #EMCC-980162IDAA
                                                                                                       Page 9 of 17
                                                                                           Issue Date: 2003-JUN-18


                             Test of Conti Temic GmbH Type ARS 2-C, Serial number 1103070007
                                      to 47 CFR Part 15C - Intentional Radiators, §15.253




4.2 Radiated Emissions Test, up to 26.5 GHz 2

4.2.1 Test Equipment

    Type                   Manufacturer/            Serial No.               Last Calibration           Next Calibration
                           Model No.
    Receiver               Rohde & Schwarz          825132/015               July 2002                  July 2003
                           ESS
    (30 MHz - 1 GHz)
    Antenna                EMCO 3143                9604-1269                June 2002                  Dec. 2003
    (30 MHz - 1 GHz)
    Receiver               Rohde & Schwarz                                   May 2002                   Nov. 2003
                           ESAI-D                   833771/008
    (1 GHz - 26.5
                           ESMI-RF                  833827/002
    GHz)
                           ESMI-B1                  832504/005
    Antenna                Schwarzbeck              137                      Oct. 2001                  Oct. 2003
    (1 GHz - 18 GHz)       BBHA 9120 D
    Standard Gain          Mid Century              1362/86                  May 2002                   May 2004
    Horn Antenna           MC 20/31B
    (18 GHz - 26.5
    GHz)


4.2.2 Test Procedures
For tabletop equipment, the EUT is placed on a 1 meter by 1.5 meters wide and 0.8 meter high
nonconductive table that sits on a flush mounted metal turntable. Floor standing equipment is placed
directly on the flush mounted metal turntable. The EUT is connected to its associated peripherals with
any excess I/O cabling bundled to approximately 1 meter.
The EUT was tested as a tabletop equipment, connected with peripherals as described in chapter 2.2.
The tests were performed in one mode as described in chapter 2.3.
The initial step in collecting radiated data is a peak scan of the measurement range with an EMI test
receiver under closer distances as given in the rule. The significant peaks are then measured with the
appropriate distance and detectors.
Worst case radiated emissions are listed under chapter: test results.




2
    The end frequency 26.5 GHz of this chapter was selected because of the end frequency of the coaxial RF input of the
     spectrum analyzer used as test receiver.
ARS 2 C_FCC_IDAA.DOC


                                                                      Test Report #EMCC-980162IDAA
                                                                                        Page 10 of 17
                                                                             Issue Date: 2003-JUN-18


                       Test of Conti Temic GmbH Type ARS 2-C, Serial number 1103070007
                                to 47 CFR Part 15C - Intentional Radiators, §15.253




Radiated Emissions Test Characteristics
Frequency range                                        30 MHz - 26,500 MHz
Test distance                                          3m
Test instrumentation resolution bandwidth              120 kHz (30 MHz - 1,000 MHz)
                                                       1 MHz (1,000 MHz - 26,500 MHz)
Test instrumentation detector                          QP (30 MHz - 1,000 MHz)
                                                       AV/PK (1,000 MHz - 26,500 MHz)
Receive antenna scan height                            1m-4m
Receive antenna polarization                           Vertical/Horizontal



4.2.3 Calculation of Field Strength Limits
Calculation: microvolts/meter to dBµV/m
Frequency                       Field Strength                        Measurement        Remarks
                                                                      distance
(MHz)                           (microvolts/meter)   (dBµV/m)         (meters)
30–88                           100                  40               3
88–216                          150                  43.5             3
216–960                         200                  46               3
960-26,500                      500                  54               3




4.2.4 Average Correction Factor
NOTE: All AV measurements were performed using the test receiver’s average detector and the max.
hold facility; the average value measured directly without the necessity of additional correction factor.



4.2.5 Field Strength Calculation
The field strength is calculated by adding the Antenna Factor and Cable Factor. The basic equation with
a sample calculation is as follows:

FS = RA + AF + CF
where
    FS = Field Strength in dBµV/m
    RA = Receiver Amplitude in dBµV
    AF = Antenna Factor in dB(1/m)
    CF = Cable Attenuation Factor in dB

ARS 2 C_FCC_IDAA.DOC


                                                                                  Test Report #EMCC-980162IDAA
                                                                                                    Page 11 of 17
                                                                                         Issue Date: 2003-JUN-18


                           Test of Conti Temic GmbH Type ARS 2-C, Serial number 1103070007
                                    to 47 CFR Part 15C - Intentional Radiators, §15.253



Assume a receiver reading of 23.5 dBµV is obtained. The Antenna Factor of 7.4 dB(1/m) and a Cable
Factor of 1.1 dB are added, giving a field strength of 32 dBµV/m. The 32 dBµV/m value can be
mathematically converted to its corresponding level in µV/m.

FS = 23.5 + 7.4 + 1.1 = 32 [dBµV/m]

Level in µV/m = Common Antilogarithm (32/20) = 39.8


4.2.6 Test Results
Device:                       Adaptive Cruise Control Pulse Doppler RADAR System
Type:                         ARS 2-C
Serial number:                1103070007


                                              PRODUCT EMISSIONS DATA
No   Emission    Receiver     Test       Receiver   Correction   Distance      Result = Spec       Polari-   Margin   Remark
     Frequency   Mode and     Distance   Reading    Factor       Extrapola-    Corrected Limit     zation
                 Bandwidth                                       tion Factor   Reading
                                         RA         AF+CF        DF            FS                  Ant
     [MHz]       [kHz]        [m]        [dBµV]     [dB(1/m)]    [dB]          [dBµV/m] [dBµV/m]             [dB]

1    40          120, QP      3          27.7       10.5         0             38.2 QP   40 QP     v         1.8
2    60          120, QP      3          19         7            0             26 QP     40 QP     v         14
3    12,750      1000, AV     1          16         40.3         9.5           46.8 AV   54 AV     v         7.2
                 1000, PK     1          24.4       40.3         9.5           55.2 PK   74 PK     v         18.8
4    25,500      1000, AV     0.3        20.8       41           20            41.8 AV   54 AV     v         12.2
                 1000, PK     1          20.4       41           9.5           51.9 PK   74 PK     v         22.1




The EUT meets the requirements of this section.

Test Personnel: Reinhard Sauerschell

Test Date:         2003-06-18




ARS 2 C_FCC_IDAA.DOC


                                                                       Test Report #EMCC-980162IDAA
                                                                                         Page 12 of 17
                                                                              Issue Date: 2003-JUN-18


                        Test of Conti Temic GmbH Type ARS 2-C, Serial number 1103070007
                                 to 47 CFR Part 15C - Intentional Radiators, §15.253



4.3 Radiated Emissions Test, 26.5 GHz to 231 GHz
    (outside the operating band)

4.3.1 Test Equipment

Type                   Manufacturer/ Model      Serial No.              Last Calibration   Next
                       No.                                                                 Calibration
Receiver           Rohde & Schwarz                                      May 2002           Nov. 2003
                   ESAI-D                       833771/008
(26.5 GHz - 110    ESMI-RF                      833827/002
GHz)               ESMI-B1                      832504/005
Waveguide Mixer    R&S/Tektronix
                   FS-Z40/WM782A                840448/007
                   FS-Z60/WM782U                840449/001
                   FS-Z75/WM782V                840450/005
                   FS-Z110/WM782W               840451/005
LO Amplifier       R&S, FS-Z30                  775850/002
Standard Gain Horn FMI/Pro N 2224-25            49                      May 2002           May 2004
Ant.
Standard Gain Horn FMI/ProN 2424-25             30                      May 2002           May 2004
Ant.
Standard Gain Horn Electrof./Tho WG25-25        001                     May 2002           May 2004
Ant
Standard Gain Horn Electrof./Tho WG27-25        001                     May 2002           May 2004
Ant.
Spectrum Analyzer Tektronix 2755A1              B 010245                Dec. 2002          Dec. 2003
Waveguide Mixer    Tektronix WM 490 F           B 020970
Waveguide Mixer    Tektronix WM 490 G           B 020958
Waveguide          Tektronix 119-1728-00        678B/0567
Transition
Diplexer           Textronix 015-0385-00        003/900
Standard Gain Horn FMI/Pro N 2824-25            24                      May 2002           May 2004
Ant.
Standard Gain Horn FMI/Pro N 3024-25            001                     May 2002           May 2004
Ant.
Standard Gain Horn Electrof./Tho WR-3           001                     May 2002           May 2004
Ant.




ARS 2 C_FCC_IDAA.DOC


                                                                        Test Report #EMCC-980162IDAA
                                                                                          Page 13 of 17
                                                                               Issue Date: 2003-JUN-18


                       Test of Conti Temic GmbH Type ARS 2-C, Serial number 1103070007
                                to 47 CFR Part 15C - Intentional Radiators, §15.253




4.3.2 Test Procedures
The basic test setups and procedures are the same as for the tests 30 MHz to 26.5 GHz. Above 26.5
GHz additional external mixers have to be used, which results in additional correction factors.
Due to high mixer loss at very high frequencies the distance between the EUT and the test antenna was
reduced to very low values (some cm) to detect any emissions.
The operating band 76 GHz to 77 GHz was excluded.

Radiated Emissions Test Characteristics
Frequency range                                   26,500 MHz - 231,000 MHz
Test distance                                     0.01 - 3 * m
Test instrumentation resolution bandwidth         1 MHz
Test instrumentation detector                     PK
Receive antenna scan height                       no height scan performed due to high gain antenna
Receive antenna polarization                      Vertical/Horizontal


* According to Section 15.31 (f) (1): At frequencies at or above 30 MHz, measurements may be
performed at a distance other than what is specified provided: measurements are not made in the near
field except where it can be shown that near field measurements are appropriate due to the
characteristics of the device; and it can be demonstrated that the signal levels needed to be measured at
the distance employed can be detected by the measurement equipment. (...) When performing
measurements at a distance other than that specified, the results shall be extrapolated to the specified
distance using an extrapolation factor of 20 dB/decade (inverse linear-distance for field strength
measurements; inverse-linear-distance-squared for power density measurements).



4.3.3 Calculations of Spurious Emissions Limits

Frequency                       Field Strength                          Measurement      Remarks
                                                                        distance
(MHz)                           (microvolts/meter)     (dBµV/m)         (meters)
26,500 – 40,000                 500                    54               3


Frequency                       Power Density                           Measurement      Remarks
                                                                        distance
(MHz)                           pW/cm²               dBm/cm²            (meters)
40,000 – 200,000                600                  -62.2              3
> 200,000                       1000                 -60.0              3




ARS 2 C_FCC_IDAA.DOC


                                                                      Test Report #EMCC-980162IDAA
                                                                                        Page 14 of 17
                                                                             Issue Date: 2003-JUN-18


                       Test of Conti Temic GmbH Type ARS 2-C, Serial number 1103070007
                                to 47 CFR Part 15C - Intentional Radiators, §15.253

4.3.4 Field Strength Calculation
The field strength is calculated by adding the Antenna Factor and Mixer Loss. The basic equation with a
sample calculation is as follows:

FS = RA + AF + ML
where
    FS = Field Strength in dBµV/m
    RA = Receiver Amplitude in dBµV
    AF = Antenna Factor in dB(1/m)
    ML = Mixer Loss in dB

Assume a receiver reading of 10.2 dBµV is obtained. The Antenna Factor of 38.8 dB(1/m) and a Mixer
Loss of 22 dB are added, giving a field strength of 71 dBµV/m. The 71 dBµV/m value can be
mathematically converted to its corresponding level in µV/m.

FS = 10.2 + 38.8 + 22 = 71 [dBµV/m]

Level in µV/m = Common Antilogarithm (71/20) = 3,548


For test distance other than what is specified, but fulfilling the requirements of Section 15.31 (f)(1) the
field strength is calculated by adding additionally an extrapolation factor of 20 dB/decade (inverse linear-
distance for field strength measurements). The basic equation with a sample calculation is as follows:

FS = RA + AF + ML + DF
where
    FS = Field Strength in dBµV/m
    RA = Receiver Amplitude in dBµV
    AF = Antenna Factor in dB(1/m)
    ML = Mixer Loss in dB
    DF = Distance Extrapolation Factor in dB,
      where DF = 20 log (Dtest/Dspec) where Dtest = Test Distance and Dspec = Specified Distance.

Assume the tests performed at a reduced Test Distance of 1 m instead of the Specified Distance
of 3 m giving a Distance Extrapolation Factor of DF = 20 log(1m/3m) = -9.5 dB.
Assuming a receiver reading of 10.2 dBµV is obtained. The Antenna Factor of 38.3 dB(1/m), the Mixer
Loss of 22 dB and the Distance Factor of -9.5 dB are added, giving a field strength of 61.5 dBµV/m. The
61.5 dBµV/m value can be mathematically converted to its corresponding level in µV/m.

FS = 10.2 + 38.8 + 22 - 9.5 = 61.5 [dBµV/m]

Level in µV/m = Common Antilogarithm (61.5/20) = 1,188




ARS 2 C_FCC_IDAA.DOC


                                                                                    Test Report #EMCC-980162IDAA
                                                                                                      Page 15 of 17
                                                                                           Issue Date: 2003-JUN-18


                            Test of Conti Temic GmbH Type ARS 2-C, Serial number 1103070007
                                     to 47 CFR Part 15C - Intentional Radiators, §15.253




4.3.5 Power Density Calculation
The power density is calculated by using the reading, mixer loss, effective aperture of the antenna and
distance correction factor (20 dB/dec relation).
The basic calculation is similar as described in the chapter above with the difference, that the result is
the power density:

PD = RA + ML + DF - A
where
   PD = Power Density in dBm/cm²,
   RA = Receiver Amplitude in dBm,
   ML = Mixer Loss in dB,
   DF = Distance Extrapolation Factor in dB,
   A = effective Antenna Aperture in dB(cm²)
      where DF = 20 log (Dtest/Dspec) where Dtest = Test Distance and Dspec = Specified Distance,
      and A = 10 log (effective Antenna Aperture in cm²).

For an assumed result of -60 dBm/cm² the level in pW/cm² is:
109 x Common Antilogarithm (-60/10) = 1,000


4.3.6 Test Results
Device:                        Adaptive Cruise Control Pulse Doppler RADAR System
Type:                          ARS 2-C
Serial number:                 1103070007


                              PRODUCT EMISSIONS DATA, 26.5 GHz < f < 40 GHz
No   Emission   Receiver     Test      Receiver   Antenna     Mixer   Distance      Result =    Spec       Polarization Margin
     Frequen-   Mode and     Distan-   Reading    Factor      Loss    Extrapola-    Corrected   Limit
     cy         Bandwidth    ce                                       tion Factor   Reading                Ant
                                       RA         AF          ML      DF            FS
     [MHz]      [kHz]        [m]       [dBµV]     [dB(1/m)]   [dB]    [dB]          [dBµV/m]    [dBµV/m]               [dB]



                No emissions found above noise within this frequency band




ARS 2 C_FCC_IDAA.DOC


                                                                                     Test Report #EMCC-980162IDAA
                                                                                                       Page 16 of 17
                                                                                            Issue Date: 2003-JUN-18


                           Test of Conti Temic GmbH Type ARS 2-C, Serial number 1103070007
                                    to 47 CFR Part 15C - Intentional Radiators, §15.253




                 PRODUCT EMISSIONS DATA, f > 40 GHz (excluding the operation band)

Receiver Mode: PK
Bandwidth: 1000 kHz
Polarization of antenna: h/v (worst case)
Gain of measurement antennas: f<220GHz: 25 dBi, f>220GHz: 30 dBi
No   Emission   Test      Receiver   Mixer   Distance    Eff.        Result =    Spec        Margin   Remark
     Frequen-   Distan-   Reading    Loss    Extrapola   Antenna     Corrected   Limit
     cy         ce                           -tion       Area        Reading
                          RA         ML      Factor      A           FS
                                             DF
     [MHz]      [m]       [dBm]      [dB]    [dB]        [dB(cm²)]   [dBm/cm²]   [dBm/cm²]   [dB]

1    76,000     1         -93        31      -9.5        5.9         -77.4       -62.2       15.2     noise, lower band
                                                                                                      edge
2    77,000     1         -95        31      -9.5        5.8         -79.3       -62.2       17.1     noise, upper band
                                                                                                      edge


NOTE: no emissions found above noise over the whole frequency range




The EUT meets the requirements of this section.

Test Personnel: Reinhard Sauerschell

Test Date: 2003-06-18




ARS 2 C_FCC_IDAA.DOC


                                                                      Test Report #EMCC-980162IDAA
                                                                                        Page 17 of 17
                                                                             Issue Date: 2003-JUN-18


                       Test of Conti Temic GmbH Type ARS 2-C, Serial number 1103070007
                                to 47 CFR Part 15C - Intentional Radiators, §15.253




5 MISCELLANEOUS COMMENTS AND NOTES
None.




6 LIST OF ANNEXES


Following annexes are separated parts from this test report.


Description                                                                         Pages
Annex 1: Photographs of test setups                                                 3
Annex 2: Photographs of equipment under test (EUT), external views                  5




ARS 2 C_FCC_IDAA.DOC



Document Created: 2003-08-01 11:55:57
Document Modified: 2003-08-01 11:55:57

© 2024 FCC.report