Exhibit 11 RF Exposure Info

FCC ID: OAYARS2-B

RF Exposure Info

Download: PDF
FCCID_372567

 COntinental ®
                                              TEMIC                                                   cce sstoms

Subject:                         RF Exposure Information Pursuant to Section 15.253(f)
                                 FCC ID: OAYARS2—A


To Whom It May Concern:

The following RF Exposure information is stated in the Test Report, Section 8.6, and
is repeated here:
When the vehicle is not in motion, the appropriate category for RF Exposure is
general population/uncontrolled exposure. At 76—77 GHz the specification limits
exposure to 1 mW/cm*.
Stationary is the only operational configuration that must be evaluated for RF
exposure.
All axis and polarizations of the DUT were investigated. The maximum power was
detected in the co—polarized plane of the transmit antenna of the DUT .
The calculation is based on the received power level divided by the effective aperture
at 76.5 GHz of the standard gain horn antenna.
Measurement data taken from the Test Report show that the radar unit not in motion
produces a maximum level of —30.3 dBm/cm* measured at a distance of 20 cm using
a standard gain horn and a Rohde & Schwarz Analyzer with external Mixer. This is
equivalent to 0.9 uW/cm*.
For unwanted emissions outside the band the power was negligible.
The margin of compliance is > 30 dB and hence the device meets the requirements
of Sections 1.1307, 1.1310 and 2.1091 of the Rules.

This information does apply to the model variants ARS 2—B (FCC—ID: OAYARS2—B)
and ARS 2—C (FCC—ID: OAYARS2—C) too, because these variants also have a
transmitter switch—off function when the vehicle is not in motion.
Further on the Radiated Emission Tests show that the emission of the model variants
ARS 2—BR and ARS 2—C is similar to ARS 2—A.

Best Regards,




  (2 fl”’@\                                           ,/l“.t\_?")wLfi,'ZooJ
On behalfof A.D.C. Automotive Distance Control Systems GmbH




   ADC.                            Telefon (0 83 82) 96 99— 0   Sitz der Gesellschaft:     Geschaftsfuhrung:     Bankverbindung:
   Automotive Distance Control     Telefax (0 83 82) 96 99 19   Lindau                     Michaei Schamberger   Deutsche Bank AG
   Systems GmbH                     www.temic.com               Amtsgericht Kempten                              Friedrichshafen
   Kemptener StraBe 99                                          HRB 6408                                         BLZ 650 700 84
   88131 Lindau                                                 Ust.—ID—Nr. DE 812185464                         Kto. 34 000 82



Document Created: 2019-05-30 09:43:34
Document Modified: 2019-05-30 09:43:34

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC