11.11    TEST: RF Exposure Requirements                                                                      PASS

Parameters required prior to the    Laboratory Ambient Temperature (°C)                        15 to 35 °C
test
                                    Relative Humidity (%)                                      30 to 60 %
Parameters recorded during the      Laboratory Ambient Temperature (°C)                             ---
test
                                    Relative Humidity (%)                                           ---
                                    Air pressure (hPa)                                            1020

                                        Power Supply & Frequency                           Application Point
Fully configured sample tested at                         +5V dc                                 ---------
the power line frequency
Equipment mode:                     Operation mode                                                 #1
FCC Standard                                                           § 1.1310 (1) (B)
Systems operating under the provisions of this section shall be operated in a manner that ensures that
the public is not exposed to radio frequency energy levels in excess of the Commission's guidelines §
1.1310, table (1) (b)
EUT classification (fixed, mobile or
                                     Fixed equipment used in Uncontrolled Exposure environment
portable devices)

Limits                                                                        2
                                    f/1500   (Power Density (mW/cm ))
Freq. Range 300÷1500MHz
                       2                              2
Power Density (mW/cm )              S = P * G / 4πr


Note:
                                                          (dBi/10)
P = Conducted Power (mW); G = Numeric Gain (10                   ); r = distance (cm)




TRF FCC_15.247_000
                                              Page 105 of 106
07/10/2016


                                                                              Report No. 28110821_019

                        Max Radiated       Max Radiated    Distance
         Frequency                                                    Power Density (S)
                      Output Power (ERP)   Output Power       (r)               2            Limits
 CH                                                                      (mW/cm )
                                                                                            (f/1500)
             (MHz)          (dBm)             (mW)           (cm)

 Low         902,75         10,49             11,20              20   0,0022x1.64 < 0.004    0,602

Middle       915,25         10,75             11,89              20   0,0023x1.64 < 0.004    0,610

High         927,25         10,50             11,22              20   0,0022x1.64 < 0.004    0,618

                                                VERDICT
  The EUT Radiated Power density at evaluation distance is WHITIN THE LIMIT at the distance of
                                            20cm.




                                    END OF TEST REPORT