MPE Prediction

FCC ID: OA3RN1723

RF Exposure Info

Download: PDF
FCCID_2597265

                             Microchip Technology Inc.
                2355 West Chandler Blvd. Chandler, Arizona,
                         85224—6199 United States


Federal Communications Commission
Authorization and Evaluation Division
Equipment Authorization Branch
7435 Oakland Mills Road
Columbia, MD 21046




Applicant‘s declaration concerning RF Radiation Exposure



We hereby indicate that the product
Product description: 2.4 GHz IEEE Std. 802.11 b/g Wireless LAN Module
Model No: RN1723


The equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled
environment. The integral antennas used for this transmitter must not be co—located or
operating in conjunction with any other antenna or transmitter within the host device.

A safety statement concerning minimum separation distances from enclosure of the
Product : 2.4 GHz IEEE Std. 802.11 b/g Wireless LAN Module
will be integrated in the user‘s manual to provide end—users with transmitter operating
conditions for satisfying RF exposure compliance.

The appropriate information can be drawn from the test report no: W6D21501—14761—C—1
and the accompanying calculations.



Company: Microchip Technology Inc.
Address: 2355 West Chandler Blvd. Chandler, Arizona, 85224—6199 United States


Date: 2015—04—21


Signature


  ze CGoblesk?


Registration number: W6D21501-14761-C-1
FCC ID: OA3RN1723
3.2       Equivalent isotropic radiated power
FCC Rule: 15.247(b)(3)

EIRP = max. conducted output power + antenna gain
EIRP = 18.27 dBm + 2.2 dBi
     = 20.47 dBm


Limit: EIRP = +36 dBm                for Antenna gain < 6 dBi

Test equipment used: ETSTW-RE 055


3.3       RF Exposure Compliance Requirements


FCC OET Bulletin 65 Edition 97.01 determines the equations for predicting       RF fields and applicable
limits.
The prediction for power density in the far-field but will over-predict power   density in the near field,
where it could be used for walking a “worst case” or conservative prediction.
                                                    PG
                                              S = ---------
                                                   4πR2
S – Power Density
P – Output power ERP
R – Distance
D – Cable Loss
AG – Antenna Gain
          Item                     Unit                     Value                  Remarks
            P                      mW                       67.14                  Peak value
            D                       dB
           AG                      dBi                        2.2
            G                                                1.66               Calculated Value
            R                       cm                        20                 Assumed value
                                        2
            S                    mW/cm                      0.022               Calculated value

Limits:
                     Limit for General Population / Uncontrolled Exposure
                    Frequency                                      Power Density
                      (MHz)                                          (mW/cm2)
                  1500 – 100.000                                         1.0




Worldwide Testing Services(Taiwan) Co., Ltd.                                             Page 17 of 54



Document Created: 2015-04-23 14:21:44
Document Modified: 2015-04-23 14:21:44

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC