                                                           RF Exposure Report

                      Report No.: SA171206E01D

                            FCC ID: O9YJKS6

                      Test Model: JKS6A

                   Serial Model: JKS6B, JKS6C, JKS6D, ATS100-YZ-S, ATS100-Y-S, ATS100-Z-S,
                                 ATS100-S
                Received Date: Feb. 18, 2019

                        Test Date: Feb. 26 ~ Mar. 18, 2019

                    Issued Date: Mar. 26, 2019


                        Applicant: Spireon Inc.

                          Address: 9724 Kingstone Pike, suite 800, Knoxville, Tennessee, USA, 37922


                       Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                   Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
                                (R.O.C.)
                 Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                33383, TAIWAN (R.O.C.)
           FCC Registration / 788550 / TW0003
      Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth ourfindings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to
us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such
notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your
unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the
uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.



Report No.: SA171206E01D                                              Page No. 1 / 5                                             Report Format Version: 6.1.1
Reference No.: 190218C33


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
3         Calculation Result of Maximum Conducted Power........................................................................... 5




Report No.: SA171206E01D                                             Page No. 2 / 5                                              Report Format Version: 6.1.1
Reference No.: 190218C33


                                         Release Control Record


Issue No.             Description                                        Date Issued
SA171206E01D          Original release                                   Mar. 26, 2019




Report No.: SA171206E01D                    Page No. 3 / 5        Report Format Version: 6.1.1
Reference No.: 190218C33


1    Certificate of Conformity


            Product: GPS Tracker

              Brand: Spireon

        Test Model: JKS6A

       Serial Model: JKS6B, JKS6C, JKS6D, ATS100-YZ-S, ATS100-Y-S, ATS100-Z-S, ATS100-S

    Sample Status: Engineering sample

          Applicant: Spireon Inc.

          Test Date: Feb. 26 ~ Mar. 18, 2019

         Standards: FCC Part 2 (Section 2.1091)
                           KDB 447498 D01 General RF Exposure Guidance v06
                           IEEE C95.1-1992



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                              , Date:         Mar. 26, 2019
                                 Polly Chien / Specialist




     Approved by :                                               , Date:         Mar. 26, 2019
                              Bruce Chen / Project Engineer




Report No.: SA171206E01D                        Page No. 4 / 5                        Report Format Version: 6.1.1
Reference No.: 190218C33


2     RF Exposure
2.1 Limits for Maximum Permissible Exposure (MPE)
    Frequency Range         Electric Field        Magnetic Field     Power Density           Average Time
         (MHz)             Strength (V/m)         Strength (A/m)       (mW/cm2)                (minutes)
                            Limits For General Population / Uncontrolled Exposure

       300-1500                   …                     …                  F/1500                   30

     1500-100,000                 …                     …                   1.0                     30
F = Frequency in MHz

2.2 MPE Calculation Formula
Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
pi = 3.1416
r = distance between observation point and center of the radiator in cm

2.3 Classification
The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So,
this device is classified as Mobile Device.


3     Calculation Result of Maximum Conducted Power
                      Frequency                                                       Power
                                      Max Power     Antenna Gain   Distance                          Limit
      Function           Band                                                        Density
                                        (dBm)           (dBi)        (cm)                          (mW/cm2)
                        (MHz)                                                       (mW/cm2)
WCDMA Band 2 1852.4-1907.6              22.41             3.6         20             0.079               1

WCDMA Band 5          826.4-846.6       23.76             1.4         20             0.065            0.550

     LTE Band 2     1850.7-1909.3       23.35             3.6         20             0.099               1

     LTE Band 4     1710.7-1754.3       23.50             2.8         20             0.085               1

     LTE Band 5       824.7-848.3       24.03             1.4         20             0.069            0.549

    LTE Band 12       699.7-715.3       24.20             1.8         20             0.079            0.466

    LTE Band 25     1850.7-1914.3       23.10             3.6         20             0.093               1

    LTE Band 26       814.7-848.3       24.06             1.4         20             0.070            0.543
Note:
1. Determining compliance based on the results of the compliance measurement, not taking into account
   measurement instrumentation uncertainty.
2. The Max. Power = Max. tune up power