RF Exposure

FCC ID: O6ZT3

RF Exposure Info

Download: PDF
FCCID_3564394

Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RDG170604001-00B

FCC §15.407 (f) & §1.1310 & §2.1091- MAXIMUM PERMISSIBLE
EXPOSURE (MPE)
Applicable Standard
According to subpart 15.407(f)and subpart §1.1310, systems operating under the provisions of this
section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy
level in excess of the Commission’s guidelines.

Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091)

                         (B) Limits for General Population/Uncontrolled Exposure
Frequency Range        Electric Field       Magnetic Field        Power Density            Averaging Time
     (MHz)            Strength (V/m)        Strength (A/m)           (mW/cm2)                (minutes)
    0.3–1.34                614                   1.63                 *(100)                    30
    1.34–30                824/f                 2.19/f               *(180/f²)                  30
    30–300                 27.5                  0.073                   0.2                     30
   300–1500                  /                      /                  f/1500                    30
 1500–100,000                /                      /                    1.0                     30

f = frequency in MHz; * = Plane-wave equivalent power density;

According to §1.1310 and §2.1091 RF exposure is calculated.


Calculation formula:

Prediction of power density at the distance of the applicable MPE limit
S = PG/4R² = power density (in appropriate units, e.g. mW/cm2);
P = power input to the antenna (in appropriate units, e.g., mW);
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
factor, is normally numeric gain;
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm);


For simultaneously transmit system, the calculated power density should comply with:




FCC Part 15.407                                                                              Page 13 of 97


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG170604001-00B

Calculated Data:

                                                  Conducted
                                                 output power     Evaluation      Power       MPE
        Frequency             Antenna Gain
                                               including Tune-     Distance      Density      Limit
          (MHz)
                                                 up Tolerance       (cm)        (mW/cm2)    (mW/cm2)
                           (dBi)   (numeric)   (dBm)     (mW)
         2412-2462           4        2.51       28      630.96     20.00         0.315         1.0
         5180-5825           4        2.51       21      125.89     20.00         0.063         1.0

 The 2.4GHz band and 5GHz band can transmit simultaneously:




=S2.4/Slimit- 2.4 + S5/Slimit- 5

=0.315/1+0.063/1

=0.378

< 1.0

Result: The device meet FCC MPE at 20 cm distance




FCC Part 15.407                                                                              Page 14 of 97



Document Created: 2017-09-15 14:05:07