Test Report_co-location

FCC ID: O6ZHXQX1AM0S

Test Report

Download: PDF
FCCID_4218125

            FCC Co-Location Test Report
            FCC ID                 : O6ZHXQX1AM0S
            Equipment              : 8-Channel LoRa Module
            Model No.              : HXQX1AM0S
            Brand Name             : machineQ
            Applicant              : Humax Co., Ltd.
            Address                : HUMAX BLDG., 2, HUMAX BLDG., 2,
                                     Yeongmun-ro, Cheoin-gu, Yongin-si,
                                     Gyeonggi-do, South Korea, 17040
            Standard               : 47 CFR FCC Part 15.247
            Received Date          : Mar. 05, 2019
            Tested Date            : Mar. 07 ~ Mar. 08, 2019


      We, International Certification Corp., would like to declare that the tested sample has been
      evaluated and in compliance with the requirement of the above standards. The test results
      contained in this report refer exclusively to the product. It may be duplicated completely for
      legal use with the approval of the applicant. It shall not be reproduced except in full without
      the written approval of our laboratory.



      Reviewed by:                        Approved by:




      Along Chen / Assistant Manager      Gary Chang / Manager




Report No.: FR782401-10CO                                                             Page : 1 of 19
Report Version: Rev. 01


                                                         Table of Contents
1        GENERAL DESCRIPTION .................................................................................................................... 5

1.1      Information.............................................................................................................................................. 5
1.2      The Equipment List ................................................................................................................................ 6
1.3      Test Standards ....................................................................................................................................... 6
1.1      Deviation from Test Standard and Measurement Procedure................................................................. 6
1.2      Measurement Uncertainty ...................................................................................................................... 7

2        TEST CONFIGURATION ....................................................................................................................... 8

2.1      Testing Condition ................................................................................................................................... 8
2.2      The Worst Test Modes and Channel Details ......................................................................................... 8

3        TRANSMITTER TEST RESULTS ......................................................................................................... 9

3.1      Unwanted Emissions into Restricted Frequency Bands ........................................................................ 9

4        TEST LABORATORY INFORMATION ............................................................................................... 19




Report No.: FR782401-10CO                                                                                                           Page : 2 of 19
Report Version: Rev. 01


                                      Release Record
     Report No.             Version                   Description      Issued Date
 FR782401-10CO              Rev. 01   Initial issue                   Mar. 26, 2019




Report No.: FR782401-10CO                                           Page : 3 of 19
Report Version: Rev. 01


                                     Summary of Test Results
    FCC Rules                        Test Items                      Measured                      Result
     15.247(d)                                          [dBuV/m at 3m]: 1513.70MHz
                          Radiated Emissions                                                        Pass
       15.209                                           53.70 (Margin -0.30dB) - AV


Declaration of Conformity:
The test results with all measurement uncertainty excluded are presented in accordance with the regulation
limits or requirements declared by manufacturers.
Comments and Explanations:
The declared values of gain for EUT presented in the report are provided by the manufacturer, and the
manufacturer takes all the responsibilities for the accuracy of the gain.




Report No.: FR782401-10CO                                                              Page : 4 of 19
Report Version: Rev. 01


1           General Description
1.1         Information
This is a Class II Permissive Change report.
This report is issued as a supplementary report to original ICC report no. FR782401-07CO.
The difference is concerned with following items:
        Modification of PCB and components of non-RF section for ESD, Ethernet Port Surge and LED circuit
         Improvement and GPIO circuit.
        Remove matching circuit and replace by band pass filter on Lora external antenna area
        Lora External antenna connector location is moved out 3.15 mm
        Having longer screw post on heat sink for WiFi
        Remove an adapter(Brand name: PHIHONG, Model name: PSAC24A-120L6)

Radiated emission tests had been re-tested and presented in following sections.


1.1.1       Specification of the Equipment under Test (EUT)
Operating Frequency           902 MHz ~ 928 MHz
Modulaton Type                CSS


1.1.2       Information of Host
        Brand Name            machineQ
        Product name          8-Channel LoRa Gateway
        Model name            HXQX1AM0S
            FCC ID            O6ZHLC0000

1.1.2.1 Antenna of Host
    Ant. No.                Model                Type       Gain (dBi)       Connector            Remark
        1                   CON 1                PIFA           3.76              UFL         Wi-Fi Antenna
        2                   CON 2                PIFA           3.86              UFL         Wi-Fi Antenna
        3          LoRa antenna (External)      Dipole          0.96              SMA          Lora Antenna
        4           LoRa antenna (Internal)    Monopole         1.02              UFL          Lora Antenna


1.1.3       Power Supply Type of Equipment under Test (EUT)
Power Supply Type                   12Vdc from adapter




Report No.: FR782401-10CO                                                               Page : 5 of 19
Report Version: Rev. 01


1.2       The Equipment List
      Test Item        Radiated Emission
      Test Site        966 chamber 3 / (03CH03-WS)
    Tested Date        Mar. 07 ~ Mar. 08, 2019
      Instrument           Manufacturer             Model No.            Serial No.      Calibration Date      Calibration Until
 Spectrum Analyzer             R&S                    FSV40               101499          Jan. 07, 2019          Jan. 06, 2020
       Receiver                R&S                    ESR3                101658          Dec. 11, 2018         Dec. 10, 2019
    Bilog Antenna         SCHWARZBECK               VULB9168           VULB9168-685       Apr. 19, 2018          Apr. 18, 2019
    Horn Antenna
                          SCHWARZBECK             BBHA 9120 D         BBHA 9120 D 1206    Jan. 07, 2019          Jan. 06, 2020
      1G-18G
    Horn Antenna
                          SCHWARZBECK              BBHA 9170           BBHA 9170517       Nov. 15, 2018         Nov. 14, 2019
      18G-40G
    Loop Antenna               R&S                   HFH2-Z2              100330          Nov. 09, 2018         Nov. 08, 2019
 Loop Antenna Cable        KOAX KABEL              101354-BW             101354-BW        Oct. 08, 2018          Oct. 07, 2019
     Preamplifier              EMC                  EMC02325              980187          Aug. 24, 2018         Aug. 23, 2019
     Preamplifier             Agilent                83017A             MY53270014        Aug. 09, 2018         Aug. 08, 2019
     Preamplifier              EMC                EMC184045B              980192          Aug. 09, 2018         Aug. 08, 2019
    RF cable-3M           HUBER+SUHNER           SUCOFLEX104             MY22620/4        Oct. 01, 2018         Sep. 30, 2019
                                               EMC104-SM-SM-80
    RF cable-8M                EMC                                        181107          Oct. 01, 2018         Sep. 30, 2019
                                                     00
    RF cable-1M           HUBER+SUHNER           SUCOFLEX104             MY22624/4        Oct. 01, 2018         Sep. 30, 2019
                                                                      EMC8D-NM-NM-800
    LF cable-0.8M              EMC             EMC8D-NM-NM-800                            Oct. 01, 2018         Sep. 30, 2019
                                                                           -001
                                               EMC8D-NM-NM-300
    LF cable-3M                EMC                                        131103          Oct. 01, 2018         Sep. 30, 2019
                                                      0
                                               EMC8D-NM-NM-130
    LF cable-13M               EMC                                        131104          Oct. 01, 2018         Sep. 30, 2019
                                                     00
    Measurement
                              AUDIX                     e3               6.120210g             NA                     NA
     Software
Note: Calibration Interval of instruments listed above is one year.



1.3       Test Standards
According to the specification of EUT, the EUT must comply with following standards and KDB documents.
47 CFR FCC Part 15.247
ANSI C63.10-2013
FCC KDB 558074 D01 15.247 Meas Guidance v05r01
FCC KDB 662911 D01 Multiple Transmitter Output v02r01


1.1       Deviation from Test Standard and Measurement Procedure
None




Report No.: FR782401-10CO                                                                                 Page : 6 of 19
Report Version: Rev. 01


C          Infernational
           Certification
           Corp.




1.2        Measurement Uncertainty
ISO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the emissions test
results be included in the report. The measurement uncertainties given below are based on a 95% confidence
level (based on a coverage factor (k=2)

                                          Measurement Uncertainty
                                    Parameters                                           Uncertainty
Radiated emission s 1GHz                                                                  +3.96 dB
Radiated emission > 1GHz                                                                  +4.51 dB




Report No.: FR782401—10CO                                                             Page : 7 of 19
Report Version: Rev. 01


C          International
           Certification
           Corp.




2           Test Configuration
2.1        Testing Condition
          Test Item                    Test Site            Ambient Condition             Tested By
Radiated Emissions                    O3CHOB3—WS              20—21°C / 66%                  Rober Lu
> FCC Designation No.:        TWO009
> FCC site registration No.:      207696
> IC site registration No.:    10807C—1


2.2         The Worst Test Modes and Channel Details

          Test item                           Test Mode                         Test Configuration
Radiated Emissions            2.4G HT20 ch6 + LoRa 923.3MHz                            1,2

Note:
1.    Test configuration are listed as listed as follows:
      Test Configuration 1: Wi—Fi + LoRa module with external antenna
      Test Configuration 2: Wi—Fi + LoRa module with internal antenna
2.     The selected channel is the maximum power channel of Wifi & LoRa




Report No.: FR782401—10CO                                                                Page : 8 of 19
Report Version: Rev. 01


C          International
           Certification
           Corp.




3          Transmitter Test Results
3.1        Unwanted Emissions into Restricted Frequency Bands
3.1.1      Limit of Unwanted Emissions into Restricted Frequency Bands

                                         Restricted Band Emissions Limit

Frequency Range (MHz)|           Field Strength (uV/m)        |Field Strength (dBuV/m)|        Measure Distance (m)

         0.009~0.490                   2400/F(kHz)                     48.5 — 13.8                         300
         0.490~1.705                  24000/F(kHz)                      33.8 — 23                          30
          1.705~30.0                         30                             29                             30
             30~88                          100                             40                              3
            88~216                          150                            43.5                             3
           216~960                          200                             46                              3
          Above 960                         500                             54                              3
Note 1:
Qusai—Peak value is measured for frequency below 1GHz except for 9—90 kHz, 110—490 kHz frequency band. Peak and
average value are measured for frequency above 1GHz. The limit on average radio frequency emission is as above table.
The limit on peak radio frequency emissions is 20 dB above the maximum permitted average emission limit
Note 2:
Measurements may be performed at a distance other than what is specified provided. When performing measurements at
a distance other than that specified, the results shall be extrapolated to the specified distance using an extrapolation
factor as below, Frequency at or above 30 MHz: 20 dB/decade Frequency below 30 MHz: 40 dB/decade.



3.1.2       Test Procedures
1.      Measurement is made at a semi—anechoic chamber that incorporates a turntable allowing a EUT
      rotation of 360°. A continuously—rotating, remotely—controlled turntable is installed at the test site to
      support the EUT and facilitate determination of the direction of maximum radiation for each EUT
      emission frequency. The EUT is placed at test table. For emissions testing at or below 1 GHz, the table
        height is 80 cm above the reference ground plane. For emission measurements above 1 GHz, the table
        height is 1.5 m.
2.       Measurement is made with the antenna positioned in both the horizontal and vertical planes of
        polarization. The measurement antenna is varied in height (1m ~ 4m) above the reference ground plane
      to obtain the maximum signal strength. Distance between EUT and antenna is 3 m.
3.    This investigation is performed with the EUT rotated 360°, the antenna height scanned between 1 m
      and 4 m, and the antenna rotated to repeat the measurements for both the horizontal and vertical
      antenna polarizations.
Note:
1.      120kHz measurement bandwidth of test receiver and Quasi—peak detector is for radiated emission below 1GHz.

2.      RBW=1MHz, VBW=3MHz and Peak detector is for peak measured value of radiated emission above 1GHz.
3.      RBW=1MHz, VBW=1/T and Peak detector is for average measured value of radiated emission above 1GHz.




Report No.: FR782401—10CO                                                                            Page : 9 of 19
Report Version: Rev. 01


3.1.3     Test Setup
Radiated Emissions below 1 GHz




Radiated Emissions above 1 GHz




Report No.: FR782401-10CO        Page : 10 of 19
Report Version: Rev. 01


Configuration 1: Wifi module + LoRa module with external antenna
3.1.4     Transmitter Radiated Unwanted Emissions (Below 1GHz)
Test Mode                   2.4G HT20 ch6 + LoRa 923.3MHz
Polarization                Horizontal




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m).
Note 3: All spurious emissions below 30MHz are more than 20 dB below the limit.




Report No.: FR782401-10CO                                                         Page : 11 of 19
Report Version: Rev. 01


Test Mode                   2.4G HT20 ch6 + LoRa 923.3MHz
Polarization                Vertical




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m).
Note 3: All spurious emissions below 30MHz are more than 20 dB below the limit.




Report No.: FR782401-10CO                                                         Page : 12 of 19
Report Version: Rev. 01


3.1.5     Transmitter Radiated Unwanted Emissions (Above 1GHz)
Test Mode                   2.4G HT20 ch6 + LoRa 923.3MHz
Polarization                Horizontal




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m).




Report No.: FR782401-10CO                                               Page : 13 of 19
Report Version: Rev. 01


Test Mode                   2.4G HT20 ch6 + LoRa 923.3MHz
Polarization                Vertical




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m).




Report No.: FR782401-10CO                                               Page : 14 of 19
Report Version: Rev. 01


Configuration 2: Wifi module + LoRa module with internal antenna
3.1.6     Transmitter Radiated Unwanted Emissions (Below 1GHz)
Test Mode                   2.4G HT20 ch6 + LoRa 923.3MHz
Polarization                Horizontal




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m).
Note 3: All spurious emissions below 30MHz are more than 20 dB below the limit.




Report No.: FR782401-10CO                                                         Page : 15 of 19
Report Version: Rev. 01


Test Mode                   2.4G HT20 ch6 + LoRa 923.3MHz
Polarization                Vertical




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m).
Note 3: All spurious emissions below 30MHz are more than 20 dB below the limit.




Report No.: FR782401-10CO                                                         Page : 16 of 19
Report Version: Rev. 01


3.1.7     Transmitter Radiated Unwanted Emissions (Above 1GHz)
Test Mode                   2.4G HT20 ch6 + LoRa 923.3MHz
Polarization                Horizontal




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m).




Report No.: FR782401-10CO                                               Page : 17 of 19
Report Version: Rev. 01


Test Mode                   2.4G HT20 ch6 + LoRa 923.3MHz
Polarization                Vertical




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m).




Report No.: FR782401-10CO                                               Page : 18 of 19
Report Version: Rev. 01


C          International
           Certification
           Corp.




4          Test laboratory information
Established in 2012, ICC provides foremost EMC & RF Testing and advisory consultation services by our
skilled engineers and technicians. Our services employ a wide variety of advanced edge test equipment and
one of the widest certification extents in the business.


International Certification Corp (EMC and Wireless Communication Laboratory), it is our definitive objective is
to institute long term, trust—based associations with our clients. The expectation we set up with our clients is
based on outstanding service, practical expertise and devotion to a certified value structure. Our passion is to
grant our clients with best EMC / RF services by oriented knowledgeable and accommodating staff.


Our Test sites are located at Linkou District and Kwei Shan District. Location map can be found on our
website http //vww.icertifi.com.tw.


Linkou                                 Kwei Shan                            Kwei Shan Site II
Tel: 886—2—2601—1640                   Tel: 886—3—271—8666                  Tel: 886—3—271—8640
No. 30—2, Ding Fwu Tsuen, Lin          No. 3—1, Lane 6, Wen San 3rd St.,    No. 14—1, Lane 19, Wen San 3rd
Kou District, New Taipei City,         Kwei Shan District, Tao Yuan City    St., Kwei Shan District, Tao Yuan
Taiwan, R.O.C.                         333, Taiwan, R.0.C.                  City 333, Taiwan, R.O.C..


If you have any suggestion, please feel free to contact us as below information

Tel: 886—3—271—8666
Fax: 886—3—318—0155
Email: ICC_Service@icertifi.com.tw




==END=




Report No.: FR782401—10CO                                                                  Page : 19 of 19
Report Version: Rev. 01



Document Created: 2019-03-28 16:09:35
Document Modified: 2019-03-28 16:09:35

© 2024 FCC.report