Test report

FCC ID: O55602119

Test Report

Download: PDF
FCCID_4393738

                          Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                                  Report No: CCISE190702105

1        Cover Page

                                      FCC REPORT
Applicant:                                 SWAGTEK

Address of Applicant:                      10205 NW 19th St. Suite 101, Miami, FL, 33172

Equipment Under Test (EUT)

    Product Name:                          6 inch 3G Smart Phone

    Model No.:                             X60G, NEMESIS, W609

    Trade mark:                            LOGIC, iSWAG, UNONU

FCC ID:                                    O55602119

Applicable standards:                      FCC CFR Title 47 Part 15 Subpart B

Date of sample receipt:                    09 Jul., 2019

Date of Test:                              10 Jul., to 29 Jul., 2019

Date of report issued:                     30 Jul., 2019

Test Result:                               PASS *
  * In the configuration tested, the EUT complied with the standards specified above.




 Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.


                                                                                 Report No: CCISE190702105

2      Version
      Version No.                            Date                                  Description
             00                         30 Jul., 2019                                Original




    Tested by:                                                           Date:          30 Jul., 2019

                                       Test Engineer

    Reviewed by:                                                         Date:          30 Jul., 2019

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1907021
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                         Page 2 of 18


                                                                                                                            Report No: CCISE190702105

3         Contents
                                                                                                                                                                                 Page
1     COVER PAGE ....................................................................................................................................................... 1
2     VERSION ............................................................................................................................................................... 2
3     CONTENTS ........................................................................................................................................................... 3
4     TEST SUMMARY .................................................................................................................................................. 4
5     GENERAL INFORMATION .................................................................................................................................. 5
    5.1    CLIENT INFORMATION ...................................................................................................................................................... 5
    5.2    GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
    5.3    TEST MODE.................................................................................................................................................................... 5
    5.4    MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
    5.5    DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
    5.6    RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................... 6
    5.7    DESCRIPTION OF CABLE USED ............................................................................................................................................ 6
    5.8    LABORATORY FACILITY ...................................................................................................................................................... 6
    5.9    LABORATORY LOCATION ................................................................................................................................................... 6
    5.10      TEST INSTRUMENTS LIST ............................................................................................................................................... 7
6     TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1    CONDUCTED EMISSION ..................................................................................................................................................... 8
    6.2    RADIATED EMISSION ...................................................................................................................................................... 11
7     TEST SETUP PHOTO ........................................................................................................................................ 17
8     EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 18




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                               Project No.: CCISE1907021
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                                        Page 3 of 18


                                                                              Report No: CCISE190702105

4      Test Summary
                 Test Item                                Section in CFR 47                 Result
           Conducted Emission                                 Part 15.107                    Pass
            Radiated Emission                                 Part 15.109                    Pass
 Remark:
 Pass: The EUT complies with the essential requirements in the standard.
 N/A: The EUT not applicable of the test item.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                       Project No.: CCISE1907021
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                      Page 4 of 18


                                                                               Report No: CCISE190702105

5      General Information
5.1 Client Information
        Applicant:                              SWAGTEK
        Address:                                10205 NW 19th St. Suite 101, Miami, FL, 33172
        Manufacturer/ Factory:                  SWAGTEK
        Address:                                10205 NW 19th St. Suite 101, Miami, FL, 33172

5.2 General Description of E.U.T.
        Product Name:                           6 inch 3G Smart Phone
        Model No.:                              X60G, NEMESIS, W609
        Power supply:                           Rechargeable Li-ion Battery DC3.8V, 3000mAh
                                                Model: XCM04
        AC adapter :                            Input: AC100-240V, 50/60Hz, 0.2A
                                                Output: DC 5.0V, 1A
        Test Sample Condition:                  The test samples were provided in good working order with no
                                                visible defects.
        Remark:                                 Model No.: X60G, NEMESIS, W609, were identical inside, the
                                                electrical circuit design, layout, components used and internal
                                                wiring. the difference between them is as follows:
                                                Model: X60G corresponds to the trademark LOGIC;
                                                Model: NEMESIS corresponds to the trademark iSWAG;
                                                Model: W609 corresponds to the trademark UNONU.

5.3 Test Mode
           Operating mode               Detail description
              PC mode                   Keep the EUT in Downloading mode(Worst case)
    Charging+Recording mode             Keep the EUT in Charging+Recording mode
      Charging+Playing mode             Keep the EUT in Charging+Playing mode
              FM mode                   Keep the EUT in FM receiver mode
            GPS mode                  Keep the EUT in GPS receiver mode
 The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
 vertical polarities were performed. During the test, each emission was maximized by: having the EUT
 continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
 typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable,
 varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case
 are shown in Test Results of the following pages.

5.4 Measurement Uncertainty
                    Parameters                                              Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                      ±1.60 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                      ±3.12 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                     ±4.32 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                       ±5.38 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                      ±3.36 dB (k=2)



Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1907021
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 5 of 18


CCIS                                                                             Report No: CCISE190702105

5.5 Description of Support Units
      Manufacturer                Description                 Model           Serial Number          FCC ID/DoC

            DELL                       PC                 OPTIPLEX745               N/A                  DoC
            DELL                   MONITOR                   E178FPC                N/A                  DoC
            DELL                  KEYBOARD                   SK—8115                N/A                  DoC
            DELL                    MOUSE                    MOCSUO                 N/A                  DoC
        LENOVO                       Laptop                   SL510              2B47A65                 DoC

5.6 Related Submittal(s) / Grant (s)
       This is an original grant, no related submittals and grants.

5.7 Description of Cable Used
        Cable Type                     Description                 Length            From                 To
   Detached USB Cable                    Shielding                  1.0m              EUT             PC/Adapter
  Detached headset cable                Unshielded                  1.2m              EUT              Headset

5.8 Laboratory Facility
        The test facility is recognized, certified, or accredited by the following organizations:
        ®@ FCC — Designation No.: CN1211
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by
       FCC(Federal Communications Commission). The test firm Registration No. is 727551.
        @ ISED — CAB identifier.: CNOO21
       The 3m Semi—anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
        Registration No.: 10106A—1.
        @ CNAS — Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.
        ®    A2LA — Registration No.: 4346.01
        This laboratory is accredited in accordance with the recognized International Standard ISO/EC
        17025:2005 General requirements for the competence of testing and calibration laboratories. The test
        scope can be found as below link: https://portal.a2la.org/scopepdf/4346—0 L.pdf

5.9 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bac‘an District, Shenzhen, Guangdong, China
        Tel: +86—755—23118282, Fax: +86—755—23116366
       Email: info@ccis—cb.com, Website: http//www.ccis—cb.com




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1907021
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                             Page 6 of 18


                                                                                  Report No: CCISE190702105

5.10 Test Instruments list
 Radiated Emission:
                                                                                           Cal. Date        Cal. Due date
    Test Equipment            Manufacturer             Model No.          Serial No.
                                                                                          (mm-dd-yy)         (mm-dd-yy)
        3m SAC                  SAEMC                  9m*6m*6m               966         07-22-2017         07-21-2020
     Loop Antenna            SCHWARZBECK              FMZB1519B             00044         03-18-2019         03-17-2020
   BiConiLog Antenna         SCHWARZBECK               VULB9163               497         03-18-2019         03-17-2020
     Horn Antenna            SCHWARZBECK              BBHA9120D               916         03-18-2019         03-17-2020
     Horn Antenna            SCHWARZBECK              BBHA9120D              1805         06-22-2017         06-21-2020
     Horn Antenna            SCHWARZBECK              BBHA 9170          BBHA9170582      11-21-2018         11-20-2019
   EMI Test Software             AUDIX                    E3                           Version: 6.110919b
     Pre-amplifier                 HP                   8447D            2944A09358       03-18-2019         03-17-2020
     Pre-amplifier                 CD                  PAP-1G18             11804         03-18-2019         03-17-2020
   Spectrum analyzer         Rohde & Schwarz            FSP30              101454         03-18-2019         03-17-2020
   Spectrum analyzer         Rohde & Schwarz            FSP40              100363         11-21-2018         11-20-2019
   EMI Test Receiver         Rohde & Schwarz           ESRP7                101070        03-18-2019         03-17-2020
        Cable                    ZDECL              Z108-NJ-NJ-81          1608458        03-18-2019         03-17-2020
        Cable                 MICRO-COAX              MFR64639             K10742-5       03-18-2019         03-17-2020
        Cable                   SUHNER              SUCOFLEX100           58193/4PE       03-18-2019         03-17-2020


 Conducted Emission:
                                                                                         Cal. Date          Cal. Due date
   Test Equipment             Manufacturer            Model No.           Serial No.
                                                                                        (mm-dd-yy)           (mm-dd-yy)
  EMI Test Receiver         Rohde & Schwarz             ESCI               101189       03-18-2019           03-17-2020
    Pulse Limiter           SCHWARZBECK              OSRAM 2306             9731        03-18-2019           03-17-2020
        LISN                    CHASE                 MN2050D               1447        03-18-2019           03-17-2020
        LISN                Rohde & Schwarz           ESH3-Z5            8438621/010    07-21-2018           07-20-2019
       Cable                      HP                   10503A                N/A        03-18-2019           03-17-2020
  EMI Test Software             AUDIX                    E3                          Version: 6.110919b




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1907021
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                  Page 7 of 18


                                                                               Report No: CCISE190702105

6      Test results and Measurement Data
6.1 Conducted Emission
       Test Requirement:                FCC Part 15 B Section 15.107
       Test Method:                     ANSI C63.4:2014
       Test Frequency Range:            150kHz to 30MHz
       Class / Severity:                Class B                  Class B
       Receiver setup:                  RBW=9kHz, VBW=30kHz
       Limit:                                                                        Limit (dBµV)
                                          Frequency range (MHz)
                                                                          Quasi-peak                 Average
                                                 0.15-0.5                   66 to 56*                56 to 46*
                                                   0.5-5                       56                       46
                                                  0.5-30                       60                       50
                                        * Decreases with the logarithm of the frequency.
       Test setup:




       Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                           line impedance stabilization network(L.I.S.N.). The provide a
                                           50ohm/50uH coupling impedance for the measuring equipment.
                                        2. The peripheral devices are also connected to the main power through a
                                           LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                           termination. (Please refers to the block diagram of the test setup and
                                           photographs).
                                        3. Both sides of A.C. line are checked for maximum conducted
                                           interference. In order to find the maximum emission, the relative
                                           positions of equipment and all of the interface cables must be changed
                                           according to ANSI C63.4: 2014 on conducted measurement.
       Test environment:                Temp.:        22.5 C       Humid.:   55%          Press.:    101kPa
       Test Instruments:                Refer to section 5.10 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1907021
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                             Page 8 of 18


c c I s                                                                                        Report No: CCISE190702105

Measurement data:
 Product name:                       6 inch 3G Smart Phone                  Product model:          x60G

 Test by:                            Yaro                                   Test mode:              PC mode

 Test frequency:                     150 kHz ~ 30 MHz                       Phase:                  Line

 Test voltage:                       AC 120 V/60 Hz                         Environment:            Temp: 22.5°C                        Huni: 55%


             so Level (dBuV)


             70

             so\\—'w
             50

             40| /             3             §                                7                                    1044
                    f           \            7                                                       !             t        ¢
             30} }              |            |                                 |                                  NV        T
                        U\M    ’                              WA        i                                   h | wl              |
             z2of           |——9# u\."r                                "           “"*'“' '"\ unJ“ ‘\‘N I                           \
             10                                                                                     l                               t

                Ab :2                        4          1                2                 5         10                20               30
         Trace: 19                                                 Frequency (MHz)



                                             Read    LISN          Cable                   Limit    Over
                               Freq         Level Factor             Loss          Level    Line   Limit Remark

                        ~           MHz dBu¥y —             dB _        dB dBu¥ dBu¥ _dB
            1                 0.158         28.94   —O.44          10.77           39.27   65.56   —26.29      QP
            2                 0.162         24.24   —O.44          10.77           34.57   55.34   —20.77      Average
            3                 0.262         26.51   —0.39          10.75           36.87   61.38   —24.51      QP
            4                 0.262         22.61   —0.39          10.75           32.97   §1.38   —18.41      Average
            5                 0.502         27.90   —0.39          10.76           38.27   56.00   —17.73      QP
            6                 0.502         19.80   —0.39          10.76           30.17   46.00   —15.83      Average
             T                2.§13         28.11   —0.43          10.94           38.62   56.00 —17.38 QP
             8                2.7T21        21.63   —0.43          10.93           32.13   46.00 —13.87 Average
             9                9.809         22.06   —O.61          10.93           32.38   50.00 —17.62 Average
            10              18.622          29.55   —0.90          10.92           39.57   60.00 —20.43 QP
            11              23.140          27.90   —1.02          10.89           37.77   60.00 —22.23 QP
            12              23.263          24.69   —1.03          10.89           34.55   50.00 —15.45 Average


 Notes:
 1. An initial pre—scan was performed on the line and neutral lines with peak detector.
 2.   Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                              Project No.: CCISE1 907021
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                         Page 9 of 18


c c I s                                                                               Report No: CCISE190702105


 Product name:                   6 inch 3G Smart Phone             Product model:            x60G

Test by:                         Yaro                              Test mode:                PC mode

Test frequency:                  150 kHz ~ 30 MHz                  Phase:                    Neutral

Test voltage:                    AC 120 V/60 Hz                    Environment:              Temp: 22.5°C                 Huni: 55%



            so Level (dBuV)


            70
            Go\
                                                                                                 FCC PART15 B OP

            sol                                                                                  ECC PART15B AV
                                                                                                       10
            40              1            4                           o                                           14
            30              J?          *|
                   \‘-\
            ao|           y Lw                  \.M" )
            10                                                                                                        N

                  15 2                   5          1          2                  5         10              20        30
        Trace 1t                                         Frequency (MHz)



                                      Read   LISN        Cable                    Limit      Over
                            Freq     Level Factor          Loss          Level      Line    Limit Remark

                   ______MHz dBuy — dB _ dB dBu¥ dBu¥ _dB
            1              8.202        21.31   —O.65     10.75          31.41    61.538   —23.97      QP
            2              0.262        23.89   —O.65     10.75          33.99    51.38    —17.39      Average
            3              0.471        20.27   —0.65     10.75          30.37    46.49    —16.12      Average
            4              0.502        28.82   —0.65     10.76          38.93    56.00    —17.07      qP
            5              1.654        25.04   —0.66     10.94          35.32    56.00    —20.68      qP
            6              1.654        17.66   —0.66     10.94          27.94    46.00    —18.06      Average
            T              2.581        28.40   —O.67     10.93          38.66    56.00    —17.34      QP
            8              2.707        22.01   —O.67     10.93          32.27    46.00    —13.73      Average
            9             16.839        21.21   —1.05     10.91          31.07    50.00    —18.93      Average
           10             18.039        33.72   —1.19     10.92          43.45    60.00    —16.55      qP
           11             23.140        27.77   —1.43     10.89          37.23    60.00    —22.77      gP
           12             24.015        25.52   —1.44     10.88          34.96    50.00    —15.04      Average

 Notes:
 1. An initial pre—scan was performed on the line and neutral lines with peak detector.
 2. Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongijian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE1907021
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                           Page 10 of 18


                                                                         Report No: CCISE190702105

6.2 Radiated Emission
        Test Requirement:             FCC Part 15 B Section 15.109
        Test Method:                  ANSI C63.4:2014
        Test Frequency Range:         30MHz to 6000MHz
        Test site:                    Measurement Distance: 3m (Semi-Anechoic Chamber)
        Receiver setup:                 Frequency       Detector        RBW      VBW           Remark
                                       30MHz-1GHz      Quasi-peak      120kHz   300kHz    Quasi-peak Value
                                                         Peak           1MHz     3MHz       Peak Value
                                       Above 1GHz
                                                         RMS            1MHz     3MHz      Average Value
        Limit:                               Frequency           Limit (dBuV/m @3m)          Remark
                                           30MHz-88MHz                    40.0           Quasi-peak Value
                                          88MHz-216MHz                    43.5           Quasi-peak Value
                                          216MHz-960MHz                   46.0           Quasi-peak Value
                                           960MHz-1GHz                    54.0           Quasi-peak Value
                                                                          54.0            Average Value
                                            Above 1GHz
                                                                          74.0             Peak Value
        Test setup:                   Below 1GHz




                                      Above 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.: CCISE1907021
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                    Page 11 of 18


                                                                               Report No: CCISE190702105


        Test Procedure:                 1. The EUT was placed on the top of a rotating table 0.8 meters above
                                           the ground at a 3 meter semi-anechoic camber. The table was rotated
                                           360 degrees to determine the position of the highest radiation.
                                        2. The EUT was set 3 meters away from the interference-receiving
                                           antenna, which was mounted on the top of a variable-height antenna
                                           tower.
                                        3. The antenna height is varied from one meter to four meters above the
                                           ground to determine the maximum value of the field strength. Both
                                           horizontal and vertical polarizations of the antenna are set to make the
                                           measurement.
                                        4. For each suspected emission, the EUT was arranged to its worst case
                                           and then the antenna was tuned to heights from 1 meter to 4 meters
                                           and the rotatable table was turned from 0 degrees to 360 degrees to
                                           find the maximum reading.
                                        5. The test-receiver system was set to Peak Detect Function and
                                           Specified Bandwidth with Maximum Hold Mode.
                                        6. If the emission level of the EUT in peak mode was 10dB lower than the
                                           limit specified, then testing could be stopped and the peak values of
                                           the EUT would be reported. Otherwise the emissions that did not have
                                           10dB margin would be re-tested one by one using peak, quasi-peak or
                                           average method as specified and then reported in a data sheet.
        Test environment:               Temp.:        24 C         Humid.:    57%         Press.:    1 01kPa
        Test Instruments:               Refer to section 5.10 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed
        Remark:                         All of the observed value above 6GHz ware the niose floor , which were
                                        no recorded




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1907021
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 12 of 18


c c I s                                                                                                     Report No: CCISE190702105

Measurement Data:
Below 1GHz:

 Product Name:                     6 inch 3G Smart Phone                                  Product Model:             X60G

 Test By:                          Yaro                                                   Test mode:                 PC mode

 Test Frequency:                   30 MHz ~1 GHz                                          Polarization:              Vertical

 Test Voltage:                     AC 120/60Hz                                            Environment:               Temp: 24°C      Huni: 57%




          8o Level (dBuVim)


          70

          60
                                                                                                                   FCC PART1S CLASS$ 8




                                                                                                                                J
                        30        50                100                                 200                        500             1000
                                                                              Frequency (MHz)




                                        Read&ntenna        Cable Preamp                                   Limit     Over
                                Freq   Level Factor          Loss Factor                        Level       Line   Limit Remark

                                 NBz      dBu¥y    db/m                        db       dB dBu¥/m dBu¥/n                 dB
                             119.856   52.52      10.89                       .11   29.39       36.19     43.50 —1.31 QP
                                                           164B co ho ho ho
            o on & uo no +




                             171.393   48.35       9.69                       .66   29.04       31.66     43.50 —11.84 QP
                             239.987   47.22      12.30                       .82   28.59       33.75     46.00 —12.25 QP
                             416.179   47.65      15.69                       12    28.81       37.65     46.00 —8.35 QP
                             T21.726   48.49      20.49                       .26   28.58       44.66     46.00 —1.34 QP
                             962.162   46.99      22.73                       .21   21.65       46.34     54.00 —7.66 QP




 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss— Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                         Project No.: CCISE1907021
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                         Page 13 of 18


c c I s                                                                                  Report No: CCISE190702105



 Product Name:                  6 inch 3G Smart Phone                   Product Model:              x60G

 Test By:                       Yaro                                    Test mode:                  PC mode

 Test Frequency:                30 MHz ~ 1 GHz                          Polarization:               Horizontal

 Test Voltage:                  AC 120/60Hz                             Environment:                Temp: 24°C         Huni: 57%




            80Le\'el (dBuVim)



            70

            60
                                                                                                FCC PART15 CLASS$ 8J
            50
            ao                                                                             3    4                5



            30                                                   1                                                    "

            20

            10


                 30           50                 100                 200                        500                  1000
                                                           Frequency (MHz)




                                    ReadAntenna        Cable Preamp                Limit        Over
                          Freq     Level Factor          Loss Factor       Level    Line       Limit Remark

                      """"NHz dBu¥ dB/m — dB _ dB dBu¥/m dBu¥/m —dB —
            1          170.195     44.30    9.64        2.66   29.056      27.55   43.50 —15.95 QP
            2          361.714     43.27   14.78        3.10   28.61       32.54   46.00 —13.46 qP
            3          416.179     48.27   15.69        3.12   28.81       38.27   46.00 —7.73 QP
            4          480.528     47.92   17.52        3.46   28.92       39.98   46.00 —6.02 QP
            5          833.317     42.40   22.20        4.24   28.07       40.86   46.00 —65.14 QP
            6          962. 162    49.19   22.73        4.27   27.65       48.54   54.00 —5.46 QP




 Remark:
 1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1907021
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                           Page 14 of 18


CCIS                                                                                       Report No: CCISE190702105

Above 1GHz:
 Product Name:                 6 inch 3G Smart Phone                      Product Model:             X60G

 Test By:                      Yaro                                       Test mode:                 PC mode

 Test Frequency:               1 GHz ~ 6 GHz                              Polarization:              Vertical

 Test Voltage:                 AC 120/60Hz                                Environment:               Temp: 24°C         Huni: 57%




          so Level (dBuVim)

                                                                                                     FCC PART 15 (PK)
          70

          60
                                                                                                     FCC PART 15 (AV)
          50


                                                                                                 3
          30 M
          ¢

          20

          10


               1000     1200          1500           2000                                                  5000     6000
                                                            Frequency (MHz)




                                   Read&ntenna         Cable Preamp                    Limit     Over
                          Freq    Level Factor           Loss Factor          Level     Line    Limit Remark

                           Nez        dbuy ~ db/m            dB       dB dBu¥/m dBu¥/m               dB
            1         4245.883    46.81      30.35      6.47      41.84       44.07    74.00   —29.93     Peak
            20        4245.883    38.71      30.35      6.47      41.84       35.97    54.00   —18.03     Average
            3          4702.434   46.78      30.83      6.85      41.96       44.91    74.00   —29.09     Peak
            4          4702.434   38.75      30.83      6.85      41.96       36.88    54.00   —17.12     Average
            5          5466.224   44.22      32.53      T.19      41.84       44.75    74.00   —29.25     Peak
            6          5466.224   34.36      32.53      T.19      41.84       34.89    54.00   —19.11     Average




 Remark:
 1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preampiifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                         Project No.: CCISE1907021
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                          Page 15 of 18


CCIS                                                                                             Report No: CCISE190702105


 Product Name:                      6 inch 3G Smart Phone                       Product Model:            X60G

Test By:                            Yaro                                        Test mode:                PC mode

Test Frequency:                      1 GHz ~6 GHz                               Polarization:             Horizontal

Test Voltage:                       AC 120/60Hz                                 Environment:              Temp: 24°C                 Huni: 57%



               Level (dBuVim)
          80
                                                                                                               FCC PART 15 (PK)
          70

          60
                                                                                                               FCC PART 15 (AV)
          50                                                                                                   x           &
                                                                                                   4           3               ie
          40

          30
               Mpiendobtentotytnbetdbluats

          20

          10


           01000          1200               1500           2000                                                    5000            6000
                                                                   Frequency (MHz)




                                          Readintenna       Cable Preamp                  Limit         Over
                             Freq        Level Factor         Loss Factor        Level     Line        Limit Remark

                               NHz           dBu¥    dB/m          dB      dB dBu¥/m dBu¥/m               dB
           1         3861.233            46.35      29.85     6.090     41.80    42.69     74.00   —31.31       Peak
           2          3861.233           38.36      29.85     6.09      41.80    34.70     54.00   —19.30       Average
           3         4504.506            47.74      30.41     6.81      42.06    45.26     74.00   —28.74       Peak
           4          4504.506           39.71      30.41     6.81      42.06    37.23     54.00   —16.77       Average
           5         §427.187            45.49      32.43     T.15      41.86    45.85     74.00   —28.15       Peak
           6          §427.187           37.51      32.43     7.15      41.86    37.87     54.00   —16.13       Average



 Remark:
 1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                              Project No.: CCISE1907021
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                         Page 16 of 18



Document Created: 2019-08-06 14:02:56
Document Modified: 2019-08-06 14:02:56

© 2024 FCC.report