 ((( . \                  SAR REFERENCE DIPOLE CALIBRATION REPORT                                                  Ref: ACR.287 8.14.SATU.A
SATIMO

       4     MEASUREMENT METHOD
The IEEE 1528, OET 65 Bulletin C and CELIIEC 62209 standards provide requirements for
reference dipoles used for system validation measurements. The following measurements were
performed to verify that the product complies with the fore mentioned standards.

       4.1   RETURN LOSS REQUIREMENTS
The dipole used for SAR system validation measurements and checks must have a return loss of —20
dB or better. The return loss measurement shall be performed against a liquid filled flat phantom,
with the phantom constucted as outlined in the fore mentioned standards.

       4.2   MECHANICAL REQUIREMENTS
The IEEE Std. 1528 and CEIMIEC 62209 standards specify the mechanical components and
dimensions of the validation dipoles, with the dimensions frequency and phantom shell thickness
dependent. The COMOSAR test bench employs a 2 mm phantom shell thickness therefore the
dipoles sold for use with the COMOSAR test bench comply with the requirements set forth for a 2
mm phantom shell thickness.


5            MEASUREMENT UNCERTAINTY

All uncertainties listed below represent an expanded uncertainty expressed at approximately the 95%
confidence level using a coverage factor of k=2, traceable to the Internationally Accepted Guides to
Measurement Uncertainty.

       5.1   RETURNLOSS
The following uncertainties apply to the return loss measurement:
                      Frequency band                                    Expanded Uncertainty on Return Loss
                        400—6000MHz                                                               0.1 dB

       5.2   DIMENSION MEASUREMENT
The following uncertainties apply to the dimension measurements:
                         Length (mm)                                        Expanded Uncertainty on Length

                              3 — 300                                                            0.05 mm



       5.3   VALIDATION MEASUREMENT
The guidelines outlined in the IEEE 1528, OET 65 Bulletin C, CENELEC EN50361 and CEIIEC
62209 standards were followed to generate the measurement uncertainty for validation
measurements.
                         Scan Volume                                       Expanded Uncertainty
                                  1 g                                                   20.30%
                                 10 g                                                   20.1 %

                                                              Page: 5/11
                This document shall not be reproduced, except infull or in part, without the written approval ofSATIMO.
                The information contained herein is to be used onlyfor the purposefor which it is submitted and is not to
                be released in whole orpart without written approval ofSATIMO.


 (((                                  SAR REFERENCE DIPOLE CALIBRATION REPORT                                          Ref: ACR287.8.14.SATU.A
sArImo     7




         6      CALIBRATION MEASUREMENT RESULTS

         6.1        RETURN LOSS AND IMPEDANCE
                                                                           Frequency, MHz
                                       2350         2380   2400     2420     2440     2460     2480   2500   2520   2550
                           S11, 48




                                     30—

   Frequency (MHz)                                 Return Loss (dB)                     Requirement (dB)                     Impedance
        2450                                            —25.59                                —20                          44.7 Q — 1.1 j62

         6.2        MECHANICAL DIMENSIONS
 Frequency MHz                                     L mm                                        h mm                              d mm

                                      required             measured                 required          measured      required            measured

       300                           420.0 £1 %.                                250.0 £1 %.                         6.35 +1 %.

       450                           290.0 £1 %.                                166.7 £1 %.                         6.35 £1 %.
       750                           176.0 £1 %.                                100.0 £1 %.                         6.35 £1 %.

       835                           161.0 +1 %.                                 89.8 +1 %.                         3.6 +1 %.
       900                           149.0 £1 %.                                83.3 +1%.                           3.6 +1 %.

       1450                          89.1 +1 %.                                  51.7 £1 %.                         3.6 +1 %.
       1500            |             80.5 £1 %.                                  50.0 £1 %.       |                 3.6 +1 %.

       1640                          79.0 1 %.                                   45.7 £1%.                          3.6 £1 %.
       1750                          75.2 £1%.                                   42.9 £1%.                          3.6 +1 %.

       1800                          72.0 £1 %.                                  41.7 £1%.                          3.6 £1 %.

       1900                          68.0 +1 %.                                  39.5 £1%.                          3.6 £1 %.
       1950                          66.3 +1 %.                                  38.5 £1%.                          3.6 £1 %.

       2000                          64.5 41 %.                                  37.5 £1%.                          3.6 £1 %.
       2100                          61.0 +1 %.                                  35.7 £1%.                          3.6 +1 %.

       2300                          55.5 41 %.                                  32.6 +1 %.                         3.6 £1 %.

       2450                          51.5 41 %.              PASS                30.4 £1%.               PASS       3.6 41 %.             PASS
       2600                          48.5 +1 %.                                  28.8 £1%.                          3.6 +1 %.

       3000                          41.5 £1%.                                   25.0 £1 %.                         3.6 £1 %.

       3500                          37.0%1%.                                    26.4 £1%.                          3.6 41 %.

       3700                          34.7%1%.                                    26.4 £1%.                          3.6 +1 %.


                                                                           Page: 6/11

                    This document shall not be reproduced, except in full orin part, without the written approval ofSATIMO.
                    The information contained hereinis to be used onlyforthepurposefor whichit is submitted and is not to
                    be released in whole orpart without writtenapproval ofSATIMO.




 noonneree reue e e e n mnnne tm nenenap snn gnegy en ces                                                                   nou n n emereg ceme se mc e y sees


 ((( . \                    SAR REFERENCE DIPOLE CALIBRATION REPORT                                                  Ref: ACR.287 8.14.SATU.A
SATIMO

           7     VALIDATION MEASUREMENT
The IEEE Std. 1528, OET 65 Bulletin C and CEIIEC 62209 standards state that the system
validation measurements must be performed using a reference dipole meeting the fore mentioned
return loss and mechanical dimension requirements. The validation measurement must be performed
against a liquid filled flat phantom, with the phantom constructed as outlined in the fore mentioned
standards. Per the standards, the dipole shall be positioned below the bottom of the phantom, with
the dipole length centered and parallel to the longest dimension of the flat phantom, with the top
surface of the dipole at the described distance from the bottom surface of the phantom.

           7.1   HEAD LIQUID MEASUREMENT

                           Fre’?/lu:zncy          Relative permittivity (€,‘)             Conductivity {0) S/m

                                                  required          measured            required          measured

                               300               45.3 15 %                             0.87 £5 %
                               450               43.5 25 %                              0.87 £5 %

                               750               41.9 25 %                              0.89 £5 %
                               835               41.5 25 %                              0.90 £5 %
                               900               41.5 25 %                              0.97 £5 %
                              1450               40.5 45 %                              1.20 25 %

                              1500               40.4 15 %                              123125 %
                              1640               40.2 25 %                              1.31 15 %
                              1750               40.1 25 %                              1.37 25 %
                              1800               40.0 25 %                              1.40 25 %
                              1900               40.0 25 %                              1.40 25 %
                              1950               40.0 25 %                              140 £5 %

                              2000               40.0 25 %                              140 25 %
                              2100               39.8 45 %                              149 £5 %
                              2300               39.5 25 %                              1.67 25 %
                              2450               39.2 25 %             PASS             1.80 25 %            PASS
                              2600               39.0 25 %                              1.96 25 %

                              3000               38.5 15 %                              2.40 £5 %
                              3500               37.9 25 %                              2.91 +5 %


           7.2    SAR MEASUREMENT RESULT WITH HEAD LIQUID
The IEEE Std. 1528 and CEUIEC 62209 standards state that the system validation measurements
should produce the SAR values shown below (for phantom thickness of 2 mm), within the
uncertainty for the system validation. All SAR values are normalized to 1 W forward power. In
bracket, the measured SAR is given with the used input power.

Software                                                                 OPENSAR V4
Phantom                                                                  SN 20/09 SAM71
Probe                                                                    SN 18/11 BPG122
Liquid                                                                   Head Liquid Values: eps‘ : 39.0 sigma : 1.77
Distance between dipole center and liquid                                10.0 mm
Area scan resolution                                                     dx=8mm/dy=8mm

                                                                Page: 7/11

                  This document shall not be reproduced, except infull or in part, without the written approval ofSATIMO.
                  The information contained herein is to be used onlyfor the purposefor which it is submitted and is not to
                  be released in whole orpart without written approval ofSATIMO.




                                                             ts c y >


 (( s \                    SAR REFERENCE DIPOLE CALIBRATION REPORT                                                         Ref: ACR287.8.14.SATU.A
SATIMD

Zoon Scan Resolution                                                    dx=8mm/dy=8m/dz=5mm
Frequency                                                               2450 MHz
Input power                                                             20 dBm
Liquid Temperature                                                      71 °C
Lab Temperature                                                         21 °C
Lab Humidity                                                            45 %




                           F
                               um*                    1 g SAR (W/ke/w)                    10 g SAR (W/kg/w)
                                                  required          measured            required                measured

                               300                  2.85                                  1.94

                               450                  4.58                                  3.06

                               750                  8.49                                  $55

                               835                  9.56                                  6.22

                               900                  10.9                                  6.99
                               1450                  29                                    16

                               1500                 30.5                                  16.8

                               1640                 34.2                                  184

                               1750                 36.4                                  19.3

                               1800                 38.4                                  20.1

                               1900                 $9.7                                  20.5
                               1950                 40.5                                  20.9

                               2000                 41.1                                  21.1

                               2100                 43.6                                  21.9

                               2300                 48.7                                  23.3

                               2450                 52.4           53.89 (5.39)            24                  24.15 (2.42)
                               2600                 55.3                                  24.6

                               3000                 63.8                                  25.7

                               3500                 67.1                                   25


                      Iemnmeame                                                                   7
                  Sutsen hssrerws                _termos_|                                  /,‘


                                                                                                                      C
    Sinkd
     ns
         PC
         tm                                                                                                           Hinn



         Jt
         Soih                                                                               8767
                                                                                            800—       \

  ( — m                                                                                   3 £00            \
   2o«      w‘-                                                                           & «n                  x
                  |                                                                         200—                    >
   we    (gna)    n on & M w 4           4   m                                              ass—                              I~——~L_]
                   [ ximet B Yieet                                                                 0   2   4   608   10 12 12‘[’"‘”3 18 20 22 2 % m 30




                                                               Page: 8/11

                  This document shall not be reproduced, except in full or in part, without the written approval ofSATIMO.
                  The information contained herein is to be used onlyforthe purposefor which it is submitted and is not to
                  be released in whole orpart without written approval ofSATIMO.


 ((ri A                                                                                                             Ref: ACR.287.8.14.SATU.A
SsArImMo                   SAR REFERENCE DIPOLE CALIBRATION REPORT



        7.3      BODY LIQUID MEASUREMENT
                          F
                              re:,l":z"“’        Relative permittivity (€,‘)             Conductivity (0) S/m
                                                 required          measured            required          measured

                                150             61.9 £5 %                             0.80 £5 %
                               300              58.2 45 %                             0.92 £5%
                               450              56.7 45 %                             0.94 £5%
                                750             55.5 45 %                             0.96 +5 %
                                835             55.2 45 %                             0.97 £5 %
                               900              55.0 45 %                              1.05 £5 %
                               915              55.0 45 %                              1.06 £5 %
                               1450             54.0 £5 %                              1.30 +5 %
                               1610             53.8 45 %                              140 +5 %
                               1800             53.3 45 %                              1.52 45 %
                               1900             53.3 45 %                              1.52 45 %
                               2000             53.3 15 %                              1.52 +5 %
                               2100             53.2 +5 %                              1.62 +5 %
                               2450             52.7 45 %             PASS             1.95 +5 %            PASS
                               2600             52.5 45 %                             21645 %
                               3000             52.0 45 %                             2.73 45 %
                               3500             51.3 45 %                             3.31 +5 %
                               5200            49.0 £10%                              5.30 £10 %
                               5300            48.9 £10%                              5.42£10%
                               5400            48.7 £10%                              5.53 210 %
                               5500            48.6 £10%                              5.65 £10 %
                               5600            48.5 £10%                              5.77 £10%
                               5800            48.2 £10 %                             6.00 £10%




        74     SAR MEASUREMENT RESULT WITH BODY LIQUID
Software                                                                OPENSAR V4
Phantom                                                                 SN 20/09 SAM71
Probe                                                                   SN 18/11 EPG122
Liquid                                                                  Body Liquid Values: eps‘ : 53.0 sigma : 1.93
Distance between dipole center and liquid                               10.0 mm
Area scan resolution                                                    dx=8mm/dy=8mm
Zoon Scan Resolution                                                    dx=8mm/dy=8m/dz=5mm
Frequency                                                               2450 MHz
Input power                                                             20 dBm
Liquid Temperature                                                      21 °C
Lab Temperature                                                         21 °C
Lab Humidity                                                            45 %




                                                               Page: 9/11

                 This document shall not be reproduced, except infull or in part, without the written approval ofSATIMO.
                 The information contained herein is to be used onlyfor the purposefor which it is submitted and is not to
                 be released in whole orpart without written approval ofSATIMO.


     &               SAR REFERENCE DIPOLE CALIBRATION REPORT                                                      honenssisAtgATOA
SATIMO


                     Fre:/lu:zncv              1 g SAR (W/ke/W)                     10 g SAR (W/kg/W)

                                                    measured                                 measured

                        2450                       54.65 (5.46)                         24.58 (2.46)



              U imimnipcirire
                hatme meey
  Gincicw
   is




                                                                                     so0—           \
                                                                                     «00 —              A\\

                                                                                     200                      >
                                                                                                                   —}
                                                                                     ags—                               _         ¥
             [ xtB Y                                                                         0   ;204     10 122 LJ 16 1t 0
                                                                                                                          P 2 2
                                                                                                                              i ®
                                                                                                                                ® m
                                                                                                                                  2
                                                                                                                  2 jur)




                                                        Page: 10/11

            This document shall not be reproduced, except infull orin part, without the written approval ofSATIMO.
            The information contained hereinis to be used onlyforthe purposefor which it is submitted and is not to
            be released in whole orpart without written approval ofSATIMO.




                                                      nc nscz >


                            SAR REFERENCE DIPOLE CALIBRATION REPORT                                                  Ref: ACR.287.8.14.SATU.A




       8    LIST OF EQUIPMENT



                                                Equipment Summary Sheet

    Equipment                Manufacturer / Identification No.     Current                                             Next Calibration
    Description                  Model                         Calibration Date                                              Date

   SAM Phantom                       Satimo                SN—20/09—SAM71 yeao:ijf‘éz_d' Noise)                      Y;fif;gd         No: se
COMOSAR Test Bench|                Version 3                         NA               f(:jf‘etz_d' hNgie)            ;g'jfetzd       No: te)
  Network Analyzer           Rhode8Schwarz                      sN100132                        022016                        022019
      Calipers                       Carrera                  CALIPER—1                         122016                        122019
  Reference Probe                    Satimo               EPG122 SN18A1                         102018                        102019
     Multimeter                 Keithley 2000                    1188656                        122016                        122019
  Signal Generator             Agilent E4438C                 my490705s81                       122016                        122019

      mote                       xucom                            mice                    neearan nerorer
    Power Meter                   HP E4418A                   Usss2e1498                        122016                        122019
   Power Sensor                 HP ECP—E26A                   uss7181460                        122016                        122019
 Directional Coupler           Narda 4216—20                       o1386               tcegf‘rafigegsf’fegflfigf ;Z?Fafifng?egflfi;g’
  Li?”n‘?fi'@téfnig?          Control Company                     11—661—9                        arois                        8019




                                                               Page: 11/11

                  This document shall not be reproduced, except infull or in part, without the written approval ofSATIMO.
                  The information contained herein is to be used onlyfor the purposefor which it is submitted and is not to
                  be released in whole orpart without written approval ofSATIMO.


6. SAR System PHOTOGRAPHS




                       Liquid depth&15cm


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                    FCC ID: O55503719                    Report No.: LCS190923018AEB


7. SETUP PHOTOGRAPHS

                                                  Head Setup Photo (Left Cheek)




                                                  Head Setup Photo (Left Tilt)




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                               Page 139 of 144


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                    FCC ID: O55503719                    Report No.: LCS190923018AEB


                                               Head Setup Photo (Right Cheek)




                                                 Head Setup Photo (Right Tilt)




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                               Page 140 of 144


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                    FCC ID: O55503719                    Report No.: LCS190923018AEB



                                   10mm body-worn Back Side Setup Photo (hotspot)




                                   10mm body-worn Front Side Setup Photo (hotspot)




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                               Page 141 of 144


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                    FCC ID: O55503719                    Report No.: LCS190923018AEB


                                    10mm body-worn Left Side Setup Photo (hotspot)




                                      10mm body-worn Right Side Setup Photo (hotspot)




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                               Page 142 of 144


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                    FCC ID: O55503719                    Report No.: LCS190923018AEB


                                    10mm body-worn Top Side Setup Photo (hotspot)




                                  10mm body-worn Bottom Side Setup Photo (hotspot)




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                               Page 143 of 144


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                    FCC ID: O55503719                    Report No.: LCS190923018AEB


8. EUT PHOTOGRAPHS




                                                                Fig.1


                                                                                         GSM/WCDMA/LTE
                                      WIFI/BT/GPS                                            Antenna
                                        Antenna




                                  LTE Diversity
                                    Antenna


                                                                Fig.2




                       .....................The End of Test Report.........................

  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                               Page 144 of 144



Document Created: 2019-11-04 18:22:46
Document Modified: 2019-11-04 18:22:46

© 2024 FCC.report