FCC MPE Report

FCC ID: O5541SKN1

RF Exposure Info

Download: PDF
FCCID_4418882

     SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: O5541SKN1          Report No.:LCS190614011AEA


                                      Maximum Permissible Exposure Report
Product Information
  FCC ID:                                        O5541SKN1
  Product name                                   Smart Door Bell
  Model number                                   SMART RING
                                                 Input: 3.6V/10.8Wh
  Power supply
                                                 Output:5V/1A
                                                 IEEE 802.11b: DSSS(CCK,DQPSK,DBPSK)
  Modulation Type                                IEEE 802.11g: OFDM(64QAM, 16QAM, QPSK, BPSK)
                                                 IEEE 802.11n HT20: OFDM (64QAM, 16QAM, QPSK,BPSK)
  Antenna Type                                   Internal Antenna
  Antenna Gain                                   2.0dBi (Max.)
  Hardware version                               V 1.0
  Software version                               V 1.0
                                                 IEEE 802.11b:2412-2462MHz
  WLAN FCC Operation frequency                   IEEE 802.11g:2412-2462MHz
                                                 IEEE 802.11n HT20:2412-2462MHz
  Extreme temp. Tolerance                        -20°C to +55°C
  Exposure category                              General population/uncontrolled environment
  EUT Type                                       Production Unit
  Device Type                                    Stationary Device


2. Evaluation Method
Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures
that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines.
In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile
device whereby a distance of 0.2m normally can be maintained between the user and the device, and below
RF Permissible Exposure limit shall comply with.

In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum
of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the
calculated/estimated, numerically modelled or measured field strengths or power density, is ≤ 1.0. The MPE
ratio of each antenna is determined at the minimum test separation distance required by the operating
configurations and exposure conditions of the host device, according to the ratio of field strengths or power
density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from
measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not
apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions.
The antenna installation and operating requirements for the host device must meet the minimum test
separation distances required by all antennas, in both standalone and simultaneous transmission operations,
to satisfy compliance.


3. Limit
3. 1 Refer evaluation method

ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency
Electromagnetic Fields, 3 kHz to 300 GHz.
FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF
Exposure Procedures and Equipment Authorization Policies.
FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits.
FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.