Tes report

FCC ID: O55185118

Test Report

Download: PDF
FCCID_4189001

                          Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                                  Report No: CCISE181216103

1        Cover Page

                                      FCC REPORT
Applicant:                                 SWAGTEK

Address of Applicant:                      10205 NW 19th St. Suite 101, Miami, FL, 33172

Equipment Under Test (EUT)

    Product Name:                          1.8 inch 2G Bar Phone

    Model No.:                             A8, Quartz, J8

    Trade mark:                            LOGIC, iSWAG, UNONU

FCC ID:                                    O55185118

Applicable standards:                      FCC CFR Title 47 Part 15 Subpart B

Date of sample receipt:                    29 Dec., 2018

Date of Test:                              29 Dec.,2018 to 11 Jan., 2019

Date of report issued:                     12 Jan., 2019

Test Result:                               PASS *
  * In the configuration tested, the EUT complied with the standards specified above.




 Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.


                                                                                 Report No: CCISE181216103

2      Version
      Version No.                        Date                                    Description
            00                     12 Jan., 2019                                   Original




    Tested by:                                                           Date:          12 Jan., 2019

                                       Test Engineer

    Reviewed by:                                                         Date:          12 Jan., 2019

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1812161
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                          Page 2 of 18


                                                                                                                            Report No: CCISE181216103

3         Contents
                                                                                                                                                                                 Page
1     COVER PAGE ....................................................................................................................................................... 1
2     VERSION ............................................................................................................................................................... 2
3     CONTENTS ........................................................................................................................................................... 3
4     TEST SUMMARY .................................................................................................................................................. 4
5     GENERAL INFORMATION .................................................................................................................................. 5
    5.1    CLIENT INFORMATION ...................................................................................................................................................... 5
    5.2    GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
    5.3    TEST MODE.................................................................................................................................................................... 5
    5.4    MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
    5.5    DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
    5.6    RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................... 6
    5.7    DESCRIPTION OF CABLE USED ............................................................................................................................................ 6
    5.8    LABORATORY FACILITY ...................................................................................................................................................... 6
    5.9    LABORATORY LOCATION ................................................................................................................................................... 6
    5.10      TEST INSTRUMENTS LIST ............................................................................................................................................... 7
6     TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1    CONDUCTED EMISSION ..................................................................................................................................................... 8
    6.2    RADIATED EMISSION ...................................................................................................................................................... 11
7     TEST SETUP PHOTO ........................................................................................................................................ 17
8     EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 18




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                               Project No.: CCISE1812161
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                                        Page 3 of 18


                                                                              Report No: CCISE181216103

4      Test Summary
                 Test Item                                Section in CFR 47                 Result
           Conducted Emission                                 Part 15.107                    Pass
            Radiated Emission                                 Part 15.109                    Pass
 Remark:
 Pass: The EUT complies with the essential requirements in the standard.
 N/A: The EUT not applicable of the test item.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                       Project No.: CCISE1812161
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                      Page 4 of 18


                                                                                 Report No: CCISE181216103

5      General Information
5.1 Client Information
       Applicant:                              SWAGTEK
       Address of Applicant:                   10205 NW 19th St. Suite 101, Miami, FL, 33172
       Manufacturer& Factory:                  SWAGTEK
       Address:                                10205 NW 19th St. Suite 101, Miami, FL, 33172

5.2 General Description of E.U.T.
       Product Name:                           1.8 inch 2G Bar Phone
       Model No.:                              A8, Quartz, J8
       Power supply:                           Rechargeable Li-ion Battery DC3.7V-600mAh
       AC adapter:                             Model: YLT-USB-540
                                               Input: AC100-240V, 50/60Hz, 0.2A
                                               Output: DC 5.0V, 600mA
       Remark:                                 item No.: A8, Quartz, J8 were identical inside, the electrical circuit
                                               design, layout, components used and internal wiring.
                                               A8 model corresponds to the trademark LOGIC.
                                               Quartz model corresponds to the trademark iSWAG.
                                               J8 model corresponds to the trademark UNONU.
                                               All the models are electrically identical, only named differently. No
                                               other changes are made to them.
       Test Sample Condition:                  The test samples were provided in good working order with no visible
                                               defects.

5.3 Test Mode
         Operating mode                Detail description
             PC mode                   Keep the EUT in Downloading mode(Worst case)
    Charging+Recording mode            Keep the EUT in Charging+Recording mode
     Charging+Playing mode             Keep the EUT in Charging+Playing mode
             FM mode                 Keep the EUT in FM receiver mode
The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
vertical polarities were performed. During the test, each emission was maximized by: having the EUT
continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable, varying
antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown
in Test Results of the following pages.

5.4 Measurement Uncertainty
                   Parameters                                                Expanded Uncertainty
       Conducted Emission (9kHz ~ 30MHz)                                        ±2.22 dB (k=2)
        Radiated Emission (9kHz ~ 30MHz)                                        ±2.76 dB (k=2)
      Radiated Emission (30MHz ~ 1000MHz)                                       ±4.28 dB (k=2)
       Radiated Emission (1GHz ~ 18GHz)                                         ±5.72 dB (k=2)
       Radiated Emission (18GHz ~ 40GHz)                                        ±2.88 dB (k=2)


Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1812161
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                               Page 5 of 18


CCIS                                                                            Report No: CCISE181216103

5.5 Description of Support Units
      Manufacturer                 Description                 Model          Serial Number           FCC ID/DoC

            DELL                        PC                 OPTIPLEX745               N/A                  DaC
            DELL                    MONITOR                  E178FPC                 N/A                  DaC
            DELL                   KEYBOARD                   SK—8115                N/A                  DaC
            DELL                     MOUSE                   MOC§UO                  N/A                  DoC
         LENOVO                       Laptop                   SL510              2847A65                 DoC

5.6 Related Submittal(s) / Grant (s)
        This is an original grant, no related submittals and grants.

5.7 Description of Cable Used
         Cable Type                     Description                Length            From                  To
    Detached USB Cable                  Unshielded                  0.95m             EUT                Adapter
  Detached headset cable                Unshielded                  1.00m             EUT               Headset

5.8 Laboratory Facility
        The test facility is recognized, certified, or accredited by the following organizations:
        ®   FCC — Registration No.: 727551
        Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
        (Federal Communications Commission). The Registration No. is 727551.
        ®    IC — Registration No.: 10106A—1
        The 3m Semi—anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
        Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
        with Registration No.: 10106A—1.
        ® CNAS — Registration No.: CNAS L6048
        Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
        Requirements for the Competence of Testing and Calibration laboratories for the competence of
        testing. The Registration No. is CNAS L6048.
        ®    A2LA — Registration No.: 4346.01
        This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
        17025:2005 General requirements for the competence of testing and calibration laboratories. The test
        scope can be found as below link: https://portal.a2la.ora/scopepdf/4348—0 1.pdf

5.9 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bac‘an District, Shenzhen, Guangdong, China
        Tel: +86—755—23118282, Fax: +86—755—23116366
        Email: info@ccis—cb.com, Website: http//www.ccis—cb.com




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1812161
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                              Page 6 of 18


                                                                                  Report No: CCISE181216103

5.10 Test Instruments list
 Radiated Emission:
                                                                                           Cal. Date        Cal. Due date
    Test Equipment             Manufacturer            Model No.          Serial No.
                                                                                          (mm-dd-yy)         (mm-dd-yy)
        3m SAC                  SAEMC                  9m*6m*6m              966          07-22-2017         07-21-2020
     Loop Antenna            SCHWARZBECK              FMZB1519B             00044         03-16-2018         03-15-2019
   BiConiLog Antenna         SCHWARZBECK               VULB9163              497          03-16-2018         03-15-2019
     Horn Antenna            SCHWARZBECK              BBHA9120D              916          03-16-2018         03-15-2019
     Horn Antenna            SCHWARZBECK              BBHA9120D              1805         06-22-2017         06-21-2020
     Horn Antenna            SCHWARZBECK              BBHA 9170          BBHA9170582      11-21-2018         11-20-2019
   EMI Test Software             AUDIX                    E3                           Version: 6.110919b
     Pre-amplifier                 HP                   8447D            2944A09358        03-07-2018        03-06-2019
     Pre-amplifier                 CD                  PAP-1G18             11804          03-07-2018        03-06-2019
   Spectrum analyzer         Rohde & Schwarz            FSP30              101454          03-07-2018        03-06-2019
   Spectrum analyzer         Rohde & Schwarz            FSP40              100363         11-21-2018         11-20-2019
    EMI Test Receiver        Rohde & Schwarz           ESRP7                101070        03-07-2018         03-06-2019
         Cable                   ZDECL              Z108-NJ-NJ-81          1608458        03-07-2018         03-06-2019
         Cable                MICRO-COAX              MFR64639             K10742-5       03-07-2018         03-06-2019
         Cable                  SUHNER              SUCOFLEX100           58193/4PE       03-07-2018         03-06-2019


 Conducted Emission:
                                                                                          Cal. Date         Cal. Due date
    Test Equipment            Manufacturer             Model No.          Serial No.
                                                                                        (mm-dd-yy)           (mm-dd-yy)
   EMI Test Receiver        Rohde & Schwarz             ESCI               101189        03-07-2018          03-06-2019
     Pulse Limiter          SCHWARZBECK              OSRAM 2306             9731         03-07-2018          03-06-2019
         LISN                   CHASE                 MN2050D               1447         03-19-2018          03-18-2019
         LISN               Rohde & Schwarz           ESH3-Z5            8438621/010     07-21-2018          07-20-2019
        Cable                     HP                   10503A                N/A         03-07-2018          03-06-2019
   EMI Test Software            AUDIX                    E3                          Version: 6.110919b




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1812161
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                  Page 7 of 18


                                                                               Report No: CCISE181216103

6      Test results and Measurement Data
6.1 Conducted Emission
        Test Requirement:                FCC Part 15 B Section 15.107
        Test Method:                     ANSI C63.4:2014
        Test Frequency Range:            150kHz to 30MHz
        Class / Severity:                Class B                 Class B
        Receiver setup:                  RBW=9kHz, VBW=30kHz
        Limit:                                                                         Limit (dBµV)
                                           Frequency range (MHz)
                                                                           Quasi-peak               Average
                                                  0.15-0.5                   66 to 56*              56 to 46*
                                                    0.5-5                       56                     46
                                                   0.5-30                       60                     50
                                         * Decreases with the logarithm of the frequency.
        Test setup:




        Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                            line impedance stabilization network(L.I.S.N.). The provide a
                                            50ohm/50uH coupling impedance for the measuring equipment.
                                         2. The peripheral devices are also connected to the main power through
                                            a LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                            termination. (Please refers to the block diagram of the test setup and
                                            photographs).
                                         3. Both sides of A.C. line are checked for maximum conducted
                                            interference. In order to find the maximum emission, the relative
                                            positions of equipment and all of the interface cables must be changed
                                            according to ANSI C63.4: 2014 on conducted measurement.
        Test environment:                Temp.:       22.5 C       Humid.:   55%         Press.:    101kPa
        Test Instruments:                Refer to section 5.9 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1812161
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 8 of 18


CCIS                                                                                                                 Report No: CCISE181216103

Measurement data:
Product name:                                           1.8 inch 2G Bar Phone                   Product model:           AB
Test by:                                                YT                                      Test mode:               PC mode
Test frequency:                                         150 kHz ~ 30 MHz                        Phase:                   Line

Test voltage:                                           AC 120 V/60 Hz                          Environment:             Temp: 22.5°C            Huni: 55%


                  Level (dBuV)
             80

             70
                                                                                                                                   FCC PART15B OP
             60
                                                                                                                                   FCC PART15B AV
                                                                                                                 |            ;              1




                                                                                       Frequency (MHz)
         Trace: 9



                                                                       Read    LISN    Cable             Linit        Orer
                                                              Freq    Level Factor       Loss   Level     Line       Linit Remark

                                                               MHz     dBu¥      dB        dB     dBu¥    dBu¥          dB

                                                             0.158    26.28     O.17   10.77    37.22    55.56 —18. 34 Average
                       ho i0 to 0o —1 on in as Lo no+




                                                             .162     36.27    O.17    10.77    46.21    6534 —18 13 9P
                                                             0.258    24. 67   0.14    10.75    36.46    51.51 —16.05 Average
                                                             3.603    29.04    0.17    10.90    40.11    56.00 —15. 89 9P
                                                             4.092    26. 47   0.18    10.89    37.54    46.00       —8.46 Avworage
                                                             5.898    29.50    0.23    10.82    40.55    60.00 —18.45 9P
                                                             10.018   30. 93   0.32    10.94    42.19    60.00 —17.81 QP
                                                          10.179      2M.12    0.32    10.94    38.38    50.00 —11. 62 Average
                                                          16.838      36.73     0.30   10.91    47.94     60.00 —12. 06 qP
                                                          17.291      30.82    0.30    10.91    42.03    50.00 —7.97 Average
                                                          259.018     32.95     0.31   10.89    44.15    60.00 —15. 85 QP
                                                          23.018      30. 32   0. 31   10.89    41.52.   50.00       —E.48 Average




Notes:
1. An initial pre—scan was performed on the line and neutral lines with peak detector.
2. Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                      Project No.: CCISE1812161
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                       Page 9 of 18


CCIS                                                                                                             Report No: CCISE181216103


Product name:                                       1.8 inch 2G Bar Phone                     Product model:         AB
Test by:                                            YT                                        Test mode:             PC mode

Test frequency:                                     150 kHz ~ 30 MHz                          Phase:                 Neutral

Test voltage:                                       AC 120 V/60 Hz                            Environment:           Temp: 22.5°C       Huni: 55%

                 Level (dBuV)
            80

            70
                 **=k.                                                                                                         FCC PART15B OP
            60
                 _
                                                                                                                               ECC PA@T15B AV
                                                                                                                                     f   11




                                                    ll,f\/mmw
                                                                           ««mwwmm)u
                                                                                    wf‘


            ~(c18                                             5             1              2                5
                                                                                     Frequency (MHz)
        Trace:9


                                                                   Read   LISN       Cable             Linit      Over
                                                          Freq    Level Factor         Loss   Level      Line    Linit Remark

                                                           MHz     dBu¥         dB       dB    dBu¥     dBu¥        dB
                                                          0.158   27. 04    0.98     10.77    38.79    55.56 —16.77 Average
                       ra — o w ce —i0 one c no —




                                                          0.190   33.70     0.93     10.76    45.38    64.02 —18.63 9P
                                                          0.258   32. 99    0.95     10.75    44.69    61.51 —16. 82 qP
                                                          .258    26.03     0.95     10.7§    37.73    §1.5§1 —13.78 Average
                                                          5.584   24.65     1.00     10.80     36.56   §6.00 —19.44 QP
                                                          6.319   16.89      1.02    10.81.   30.72.   50.00    —19. 28   Average
                                                          9.552   22.37      1.02    10.92    34.31.   50.00    —15. 69   Average
                                                          9.809   26.30     1.02     10.95    38.34    60.00    —21.66    oP
                                                         16.486   26.75      0.83    10.91    38.49    50.00    —11.51    Average
                                                         16.573   36.15     0.83     10.91    49.839   60.00 —i0.11 oP
                                                         23.018   31.86     0.68     10.89    45.43    60.00 —14.57 QP
                                                         23.140   26. 62    0.68     10.890   38.19    50.00 —11. 81 Awerage




Notes:
1. An initial pre—scan was performed on the line and neutral lines with peak detector.
2. Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                               Project No.: CCISE1812161
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                               Page 10 of 18


                                                                           Report No: CCISE181216103

6.2 Radiated Emission
       Test Requirement:                 FCC Part 15 B Section 15.109
       Test Method:                      ANSI C63.4:2014
       Test Frequency Range:             30MHz to 6000MHz
       Test site:                        Measurement Distance: 3m (Semi-Anechoic Chamber)
       Receiver setup:                    Frequency       Detector        RBW     VBW          Remark
                                         30MHz-1GHz      Quasi-peak      120kHz  300kHz    Quasi-peak Value
                                                           Peak           1MHz    3MHz       Peak Value
                                         Above 1GHz
                                                           RMS            1MHz    3MHz      Average Value
       Limit:                                 Frequency          Limit (dBuV/m @3m)          Remark
                                            30MHz-88MHz                   40.0          Quasi-peak Value
                                           88MHz-216MHz                   43.5          Quasi-peak Value
                                           216MHz-960MHz                  46.0          Quasi-peak Value
                                            960MHz-1GHz                   54.0          Quasi-peak Value
                                                                          54.0            Average Value
                                             Above 1GHz
                                                                          74.0             Peak Value
       Test setup:                       Below 1GHz




                                         Above 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                      Project No.: CCISE1812161
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                     Page 11 of 18


                                                                               Report No: CCISE181216103


       Test Procedure:                  1. The EUT was placed on the top of a rotating table 0.8 meters above the
                                           ground at a 3 meter semi-anechoic camber. The table was rotated 360
                                           degrees to determine the position of the highest radiation.
                                        2. The EUT was set 3 meters away from the interference-receiving
                                           antenna, which was mounted on the top of a variable-height antenna
                                           tower.
                                        3. The antenna height is varied from one meter to four meters above the
                                           ground to determine the maximum value of the field strength. Both
                                           horizontal and vertical polarizations of the antenna are set to make the
                                           measurement.
                                        4. For each suspected emission, the EUT was arranged to its worst case
                                           and then the antenna was tuned to heights from 1 meter to 4 meters
                                           and the rotatable table was turned from 0 degrees to 360 degrees to
                                           find the maximum reading.
                                        5. The test-receiver system was set to Peak Detect Function and Specified
                                           Bandwidth with Maximum Hold Mode.
                                        6. If the emission level of the EUT in peak mode was 10dB lower than the
                                           limit specified, then testing could be stopped and the peak values of the
                                           EUT would be reported. Otherwise the emissions that did not have 10dB
                                           margin would be re-tested one by one using peak, quasi-peak or
                                           average method as specified and then reported in a data sheet.
       Test environment:                Temp.:       24 C         Humid.:     57%         Press.:    1 01kPa
       Test Instruments:                Refer to section 5.9 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed
       Remark:                          All of the observed value above 6GHz ware the niose floor , which were no
                                        recorded




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1812161
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 12 of 18


c c I s                                                                                                       Report No: CCISE181216103

Measurement Data:
Below 1GHz:

Product Name:                      1.8 inch 2G Bar Phone                                     Product model:             AB
Test By:                           YT                                                        Test mode:                 PC mode

Test Frequency:                    30 MHz ~ 1 GHz                                            Polarization:              Vertical

Test Voltage:                      AC 120/60Hz                                               Environment:               Temp: 24°C     Huni: 57%


           sule\'e\ (dBu\/im}


           zo

           60
                                                                                                                    FECPART1S CLAS$ 8
           50

           40

           30                                                                                     —       5         6
                                                                                   10    2      25
           20 JA                                                                   |                  :



            D30                    50                   100                           200                           500                 1000
                                                                            Frequency (MHz)


                                                Read&ntenna      Cable Preamp                             Limit    Over
                                        Freq   Level Factor       Loss Factor                   Level      Line   Limit Remark

                                        MHz     dBu¥    dB/m                       dB        dB dBu¥/m dBu¥/m           dB

                                  146. 374     40.99      8.42                    «47   29.24    22.604   43.50 —20.80 qF
                   o ons cono +




                                                                 w roro ro o ho




                                  180.017      40. 00    9. 80                     T3   28.97    23.56    43.50 —19.94 QP
                                  219.076      37.77    12.23                      86   28.71    24.14    46.00 —21.86 QP
                                  239.987      37. 60   12. 97                     82   28.59    24.80    46.00 —21.20 QOP
                                  312.179      37.M4    13.86                      98   28.48    26.20    46.00 —19.80 QP
                                  468.876      37.30    16. 65                    .36   28.90    28.50    46.00 —17.50 oP




Remark:
1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                             Project No.: CCISE1812161
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                            Page 13 of 18


c c I s                                                                                                       Report No: CCISE181216103


Product Name:                    1.8 inch 2G Bar Phone                                        Product model:         AB
Test By:                         YT                                                           Test mode:             PC mode

Test Frequency:                  30 MHz ~ 1 GHz                                               Polarization:          Horizontal

Test Voltage:                    AC 120/60Hz                                                  Environment:           Temp: 24°C     Huni: 57%


          SGLE\'E\ (dBuWim)


          zo

          60
                                                                                                                     FECPART1S CLAS$G
          50
          al— —|— _T

          30                                                                            51z
          20
          mflWWWM

           ‘30                   5o                   100                                 200                       500              1000
                                                                            Frequency (MHz)


                                              Read&ntenna      Cable Preamp                              Limit     Over
                                      Freq   Level Factor       Loss Factor                      Level    Line    Limit Remark

                                      MHz     dBu¥    dB/m                        dB       dB dBu¥/m dBu¥/m          dB

                                187.824      42.41    9. 34                      .640   29.07    25.52   43.50 —18.18 QF
                                                               t ho ho ho o ho
                 m eme cono —




                                180.017      46. 79    9. 80                     L73    28.97    30.35   4350    —13.15   9P
                                191.746      40.17    11.2%                      L810   28.89    25.34   43.50   —18.16   9P
                                239.987      36.22    12.97                      82     28.59    2342    46.00   —22.58   QP
                                312.178      37.18    13.86                      98     28.48    25.54   46.00   —20.46   QF
                                468.876      39.94    16. 65                      36    98.90    31.05   46.00 —14.95 QP




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                          Project No.: CCISE1812161
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                         Page 14 of 18


CCIS                                                                                    Report No: CCISE181216103

Above 1GHz:

Product Name:                  1.8 inch 2G Bar Phone                   Product model:              AB
Test By:                     YT                                        Test mode:                  PC mode

Test Frequency:                1 GHz ~ 6 GHz                           Polarization:               Vertical

Test Voltage:                AC 120/60Hz                               Environment:                Temp: 24°C       Huni: 57%


           so Level (dBu\im)
                                                                                                     ECC PART 15 (PK)
           zo

           60
                                                                                                     FCC PART 15 (AV)



           40                                                                1                :W
           3GMMWM WWWW                                                                        \

           20
           10

            01000    1200           1500            2000                                                  5000     6000
                                                           Frequency (MHz)


                                    Read&ntenna        Cable Preamp                  Limit         Over
                         Freq      Level Factor            Loss Ffactor      Level     Line       Limit Remark
                            MH=z     dBu? —dB/m —            dB       dB dBu¥/m dBu¥,/m              aB           CC

                1   2956.526       47.92   28. 52       5.30       41.54     40.10   74. 00 —33.90 Peak
                2    2956.525      38.67   28.52        5.10       41.54     30.95   54.00 —23.05 Average
                3   4067T.171      48.58   30. 35       6.20       41.31     43.50   74.00 —30.70 Peak
                4   4067.171       39.21   30. 33       6.20       41.81     33.93   54.00 —20.01 Average
                §    5§35.214      49.2M   32.47           T.2M4   41.81     4T.14   74.00 —26.86 Peak
                6   §§35.214       39.46   32.47        T.24       41.81     37.36   54.00 —16.65 Average




Remark:
1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of otherfrequencies are very lower than the limit and not show in test report,




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1812161
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                         Page 15 of 18


c c I s                                                                                                     Report No: CCISE181216103


Product Name:                           1.8 inch 2G Bar Phone                               Product model:            AB
Test By:                                YT                                                 Test mode:                 PC mode

Test Frequency:                         1 GHz ~ 6 GHz                                       Polarization:             Horizontal

Test Voltage:                           AC 120/60Hz                                         Environment:              Temp: 24°C        Huni: 57%


          eo Level (dBuVim)
                                                                                                                           FCC PART 15 (PK)
           r0

          60
                                                                                                                           FCC PART 15 (AV)
          50                                                                                                      F                5

                                                                                                  1               aitet
          40                                                                                       apemenonbectnt

          30 pragptnyaWW“*WWWMJM

          20

          10

                1000             1200          1500           2000                                                              5000     6000
                                                                              Frequency (MHz)


                                                 Read&ntenna      Cable Preamp                          Limit     Over
                                        Freq    Level Factor       Loss Factor                  Level    Line    Limit Remark

                                         MHz     dBu¥     dB/m                     dB      dB dBu¥/m dBu¥/m           dB

                                  2099.209      49.06    28. 60                   236   41.51   41.50   74.00 —32. 50 Peak
                  o ome cons —




                                                                  1 ~im oven on




                                  2099.209      39.23    28. 60                   36    41.51   31.67   54.00   —22. 31    Average
                                  4030.897      49.49    30.26                    18    41.81   44.09   74.00   —29.91     Peak
                                  4030.897      39.75    30.26                    «18   41.81   34.35   54.00   —13. 6§    Average
                                  §161.626      50.88    32.07                    06    41.94   48.07   74.00   —25.93     Peak
                                  5161.626      41. 20   32. 07                   .06   41.94   38.39   54.00 —15.61 Average




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lowerthan the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                           Project No.: CCISE1812161
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                             Page 16 of 18



Document Created: 2019-02-28 15:27:31
Document Modified: 2019-02-28 15:27:31

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC