    DASYS5 Validation Report for Head TSL                                        Date: 06.15.2016
    Test Laboratory: CTTL, Beijing, China
    DUT: Dipole 1900 MHz; Type: D1900V2; Serial: D1900V2 — SN: 5d175
       Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1
       Medium parameters used: f= 1900 MHz; 0 = 1.381 $/m; sr = 40.33; p = 1000 kg/m3
       Phantom section: Right Section
       Measurement Standard: DASY5 (IEEE/IEC/ANSI €63.19—2007)
    DASYS Configuration:

                *    Probe: EX3DV4 — SN7307; ConvF(8.1, 8.1, 8.1); Calibrated: 2/19/2016;
                *    Sensor—Surface: 2mm (Mechanical Surface Detection)
                *    Electronics: DAE4 Sn771; Calibrated: 2/2/2016
|               *    Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1161/1
|               +    Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7372)

            System Performance Check/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid:
            dx=5mm, dy=5mm, dz=5mm
|           Reference Value = 103.5V/m; Power Drift = 0.00 dB
            Peak SAR (extrapolated) = 18.0W/kg
            SAR(I g) =9.99 W/kg; SAR(10 g) = 5.28 W/kg
            Maximum value of SAR (measured) =14.1 W/kg

               dB
               0


                —3.41


                —6.82


                —10.24


               ~13.65

                                                   a
               —17.06                            fl—_—

                          0 dB =14.1 W/kg =11.49 dBW/kg




    Certificate No: Z16—97090                             Page 5 of 8


CCGIS
                 fi                         I;Coflabomtionewith 3

                 V                         CALIBRATION LABORATORY

               Add: No.51 Xueyuan Road, Haidian District, Beijing, 100191, China
               Tel: +86—10—62304633—2079     Fax: +86—10—62304633—2504
               E—mail: cttl@chinattl.com       Hitp://www.chinattl.en




               Impedance Measurement Plot for Head TSL


     [ Tri 11 Log Mag 10.00d8/ Ref 0.000d8 [F1]
      |     so.c0      L   1.9000000 onz —24.303 do_
            40. 00
            30. 00

            20.00

            10. 00
            0. 000p)
           —10. 00

           ~20. 00


           ~30. 00


           ~40. 00
           «8B 86 fe..__
          MIR 511 smith (R+jX) scale 1.000U [F1 bel]
            »1 1.9000000 Ghz §3.173 n 5.4373 n 455.46—pH




      [1 Strt 17 GHe                             i              IFSW 100 He        Stop 2.1 GHtc BB




    Certificate No: Z16—97090                                 Page 6 of 8


CCGIS
            i!”?\l"/                   I;Co!laborationewiflu 3


             ‘/                        CALIBRATION LABORATORY
           Add: No.51 Xueyuan Road, Haidian District, Beijing, 100191, China
           Tel: +86—10—62304633—2079      Fax: +86—10—62304633—2504
           E—mail: cttl@chinattl.com       Hitp://www.chinattl.en




    DASYS Validation Report for Body TSL                                       Date: 06.15.2016
    Test Laboratory: CTTL, Beijing, China
    DUT: Dipole 1900 MHz; Type: D1900V2; Serial: D1900V2 — SN: 50175
       Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1
      Medium parameters used: f= 1900 MHz; 0 = 1.537 S/m; s, = 53.34; p = 1000 kg/m3
      Phantom section: Center Section
      Measurement Standard: DASYS (IEEE/IEC/ANSI €63.19—2007)
    DASYS Configuration:

               +    Probe: EX3DV4 — SN7307; ConvF(7.67, 7.67, 7.67); Calibrated: 2/19/2016;
               +    Sensor—Surface: 2mm (Mechanical Surface Detection)
|              *    Electronics: DAE4 Sn771; Calibrated: 2/2/2016
|              +    Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1 161/1
               +    Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7372)

           System Performance Check/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid:
           dx=5mm, dy=5mm, dz=5mm
           Reference Value = 96.11 V/m; Power Drift =—0.03 dB
           Peak SAR (extrapolated) = 17.8 W/kg
           SAR(I g) = 10.1 W/kg; SAR(10 g) = 5.39 W/kg
           Maximum value of SAR (measured) = 14.3 W/kg


               dB
               0


                ~3.23


                —6.47


                —9.70


                ~12.94


                1617       |2
                                £.            kassmmmmmmmmmmmgaceeeee
                                                         Tess
                           0 dB = 14.3 W/kg = 11.55 dBW/kg




    Certificate No: Z16—97090                              Page 7 of 8


CCGIS
                                     *     In Collaboration with

                a=/"7"J, a
                   Wigaazgy»~              CALIBRATION LABORATORY
              Add: No.51 Xueyuan Road, Haidian District, Beijing, 100191, China
              Tel: +86—10—62304633—2079        Fax: +86—10—62304633—2504
              E—mail: cttl@chinattl.com        Hitp://www.chinattl.en


              Impedance Measurement Plot for Body TSL


        Tri S11 Log Mag 10.00d8/ Ref 0.000db [F1]
          59.00     »1   1.9000000 nz <24.565 db
          40. 00
          30. 00
          20. 00
          10. 00
          0. 000p
         ~10.00 |—==

         —20.00                                                              §
         ~30.00
         ~40. 00

         —50.00
                                                                             A
       MIBRB 511 smith (RJX) scale 1.000U [F1 bel]
         »2   1.9000000 Ghz     48.877 o    5.7473 n   481.4%—pf




|                                               [                       1
                                                                                    \
                                                                                  \\'



|                                               |\                                J}



      |                                                            ~«~
      [ Surt 17642                                             IFBW 100 He              Stop 21 GHz IRemlli




    Certificate No: Z16—97090                               Page 8 of 8


                                                                              Report No: CCISE181212401

                Dipole Impedance and Return Loss calibration Report
 Object:                           D1900V2 - SN: 5d175

 Calibration Date:                 June 10, 2018

 Calibration reference:            IEEE Std 1528:2013, IEC 62209-1:2006, FCC KDB 865664 D01

 Calibrated By:
                                                              (Janet Wei, SAR project engineer)

 Reviewed By:
                                                        (Bruce Zhang, Technical manager)


Environment of Test Site
 Temperature:                      18 ~ 25C
 Humidity:                         50~60% RH
 Atmospheric Pressure:             1011 mbar

Test Data
     Measurement Plot for Head TSL In 2017                          Measurement Plot for Body TSL In 2017




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1812124
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: info@ccis-cb.com                Page 80 of 84


                                                                                 Report No: CCISE181212401


        Measurement Plot for Head TSL In 2018                          Measurement Plot for Body TSL In 2018




   Comparison with Original report
                              Calibrated By CCIS      Calibrated By CCIS
         Items                                                                  Deviation                 Limit
                                    In 2017                 In 2018
Impendence for Head TSL         51.36Ω+7.68jΩ           53.21Ω+5.11jΩ         1.85Ω-2.57jΩ                ±5Ω
Return Loss for Head TSL            -22.3dB                 -22.9dB               2.7%         ±20%(No less than 20 dB)
Impendence for Body TSL         47.47Ω+4.24jΩ           48.56Ω+3.45jΩ         1.09Ω-0.79jΩ                ±5Ω
Return Loss for Body TSL            -26.4dB                 -28.4dB               7.6%         ±20%(No less than 20 dB)
   Result
   Compliance




   Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1812124
   No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
   Bao’an District, Shenzhen, Guangdong,China
   Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: info@ccis-cb.com                   Page 81 of 84


CCGIS
                                                                                       uy
                                           In Collaboration with                    *"/           A s BB NA 5
                                       AraW
                        T‘"T‘LI a % CNAS
                                           CALIBRATION LABORATORY                  zy                               CALIIMYION
               Add: No.51 Xueyuan Road, Haidian District, Beijing, 100191, China     hlayny‘#
                                                                                    *4            v CNAS LO570
               Tel: +86—10—62304633—2512        Fax: +86—10—62304633—2504               APME
               E—mail: ctt|@chinattl.com        Hitp:/www.chinattl.en

        Client :         CcIs                                                      Certificate No: 218—97054

   CALIBRATION CERTIFICATE

   Object                                     DAE4 — SN: 1373

   Calibration Procedure(s)                   FF—211—002—01
                                              Calibration Procedure for the Data Acquisition Electronics
                                              (DAEx)
   Calibration date:                          March 22, 2018

   This calibration Certificate documents the traceability to national standards, which realize the physical units of
   measurements(S1). The measurements and the uncertainties with confidence probability are given on the following
   pages and are part of the certificate.

   All calibrations have been conducted in the closed laboratory facility: environment temperature(22+3)°c and
   humidity<70%.

   Calibration Equipment used (M&TE critical for calibration)

   Primary Standards                ID #           Cal Date(Calibrated by, Certificate No.)       Scheduled Calibration



   Process Calibrator 753         1971018              27—Jun—17 (CTTL, No.J17X05859)                     June—18




                                    Name                       Function                               Signature
    Calibrated by:                   Yu Zongying              SAR Test Engineer                     /Aé“@

    Reviewed by:                     Lin Hao                  SAR Test Engineer                      1&,%

    Approved by:                     Qi Dianyuan              SAR Project Leader                  ePt

                                                                                               Issued: March 23, 2018
    This calibration certificate shall not be reproduced exceptin full without written approval of the laboratory.




         Certificate No: Z18—97054                                 Page 1 of 3


CCGIS
                                           In Collaboration with

                      TTL a                CALIBRATION LABORATORY

              Add: No.51 Xueyuan Road, Haidian District, Beijing, 100191, China
              Tel: +86—10—62304633—25 12        Fax: +86—10—62304633—2504
              E—mail: ctt!@chinattl.com         Hitp:/Awww.chinattl.en

    Glossary:
    DAE                              data acquisition electronics
    Connector angle                   information used in DASY system to align probe sensor X
                                     to the robot coordinate system.


    Methods Applied and Interpretation of Parameters:
    e DC Voltage Measurement: Calibration Factor assessed for use in DASY
       system by comparison with a calibrated instrument traceable to national
       standards. The figure given corresponds to the full scale range of the
       voltmeter in the respective range.

    e      Connector angle: The angle of the connector is assessed measuring the
           angle mechanically by a tool inserted. Uncertainty is not required.

    e      The report provide only calibration results for DAE, it does not contain other
           performance test results.




        Certificate No: Z18—97054                                  Page 2 of 3




                                                                                                evpeve n nee nene n e r ie



                                                                                  nsl en n en                 mc o n —


                                                                              Report No: CCISE181212401




                                        ------End of Report------

Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1812124
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: info@ccis-cb.com               Page 84 of 84



Document Created: 2019-03-11 11:56:38
Document Modified: 2019-03-11 11:56:38

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC