Test Report_JBP

FCC ID: O55184518

Test Report

Download: PDF
FCCID_4108121

                          Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                                  Report No: CCISE181102203

1        Cover Page

                                      FCC REPORT
Applicant:                                 SWAGTEK

Address of Applicant:                      10205 NW 19th St. Suite 101, Miami, FL, 33172

Equipment Under Test (EUT)

    Product Name:                          1.8 inch Feature Phone

    Model No.:                             B3S, Star-S, UM3S

    Trade mark:                            LOGIC, iSWAG, UNONU

FCC ID:                                    O55184518

Applicable standards:                      FCC CFR Title 47 Part 15 Subpart B

Date of sample receipt:                    09 Nov., 2018

Date of Test:                              09 Nov., to 27 Nov., 2018

Date of report issued:                     28 Nov., 2018

Test Result:                               PASS *
  * In the configuration tested, the EUT complied with the standards specified above.




 Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.


                                                                                 Report No: CCISE181102203

2      Version
      Version No.                        Date                                    Description
            00                     28 Nov., 2018                                   Original




    Tested by:                                                           Date:          28 Nov., 2018

                                       Test Engineer

    Reviewed by:                                                         Date:          28 Nov., 2018

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1811022
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                          Page 2 of 18


                                                                                                                           Report No: CCISE181102203

3         Contents
                                                                                                                                                                                Page
1     COVER PAGE ....................................................................................................................................................... 1
2     VERSION ............................................................................................................................................................... 2
3     CONTENTS ........................................................................................................................................................... 3
4     TEST SUMMARY .................................................................................................................................................. 4
5     GENERAL INFORMATION .................................................................................................................................. 5
    5.1   CLIENT INFORMATION ...................................................................................................................................................... 5
    5.2   GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
    5.3   TEST MODE.................................................................................................................................................................... 5
    5.4   MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
    5.5   DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
    5.6   RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................... 6
    5.7   LABORATORY FACILITY ...................................................................................................................................................... 6
    5.8   LABORATORY LOCATION ................................................................................................................................................... 6
    5.9   TEST INSTRUMENTS LIST.................................................................................................................................................... 7
6     TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1   CONDUCTED EMISSION ..................................................................................................................................................... 8
    6.2   RADIATED EMISSION ...................................................................................................................................................... 11
7     TEST SETUP PHOTO ........................................................................................................................................ 17
8     EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 18




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                              Project No.: CCISE1811022
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                                       Page 3 of 18


                                                                              Report No: CCISE181102203

4      Test Summary
                 Test Item                                Section in CFR 47                 Result
           Conducted Emission                                 Part 15.107                    Pass
            Radiated Emission                                 Part 15.109                    Pass
 Remark:
 Pass: The EUT complies with the essential requirements in the standard.
 N/A: The EUT not applicable of the test item.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                       Project No.: CCISE1811022
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                      Page 4 of 18


                                                                               Report No: CCISE181102203

5      General Information
5.1 Client Information
       Applicant:                              SWAGTEK
       Address of Applicant:                   10205 NW 19th St. Suite 101, Miami, FL, 33172
       Manufacturer/ Factory:                  SWAGTEK
       Address:                                10205 NW 19th St. Suite 101, Miami, FL, 33172

5.2 General Description of E.U.T.
       Product Name:                           1.8 inch Feature Phone
       Model No.:                              B3S, Star-S, UM3S
       Power supply:                           Rechargeable Li-ion Battery DC3.7V-600mAh
                                               Model: B3S
       AC adapter :                            Input: AC100-240V, 50/60Hz, 0.2A
                                               Output: DC 5.0V, 500mA
                                               Item No.: B3S, Star-S, UM3S were identical inside, the electrical
                                               circuit design, layout, components used and internal wiring. The only
                                               difference is that one product has three models, each model
       Remark:                                 corresponds to one brand, three The trademarks are LOGIC and
                                               iSWAG and UNONU, the B3S model corresponds to the trademark
                                               LOGIC, the Star-S model corresponds to the trademark iSWAG, and
                                               the UM3S model corresponds to the trademark UNONU.
       Test Sample Condition:                  The test samples were provided in good working order with no visible
                                               defects.

5.3 Test Mode
         Operating mode                Detail description
             PC mode                   Keep the EUT in Downloading mode(Worst case)
    Charging+Recording mode            Keep the EUT in Charging+Recording mode
     Charging+Playing mode             Keep the EUT in Charging+Playing mode
            GPS mode                 Keep the EUT in GPS receiver mode
The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
vertical polarities were performed. During the test, each emission was maximized by: having the EUT
continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable, varying
antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown
in Test Results of the following pages.

5.4 Measurement Uncertainty
                   Parameters                                              Expanded Uncertainty
       Conducted Emission (9kHz ~ 30MHz)                                      ±2.22 dB (k=2)
        Radiated Emission (9kHz ~ 30MHz)                                      ±2.76 dB (k=2)
      Radiated Emission (30MHz ~ 1000MHz)                                     ±4.28 dB (k=2)
       Radiated Emission (1GHz ~ 18GHz)                                       ±5.72 dB (k=2)
       Radiated Emission (18GHz ~ 40GHz)                                      ±2.88 dB (k=2)



Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1811022
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                           Page 5 of 18


                                                                           Report No: CCISE181102203

5.5 Description of Support Units
      Manufacturer                 Description                 Model     Serial Number         FCC ID/DoC
           DELL                         PC                OPTIPLEX745          N/A                  DoC
           DELL                     MONITOR                  E178FPC           N/A                  DoC
           DELL                   KEYBOARD                    SK-8115          N/A                  DoC
           DELL                      MOUSE                   MOC5UO            N/A                  DoC
         LENOVO                       Laptop                   SL510        2847A65                 DoC

5.6 Related Submittal(s) / Grant (s)
        This is an original grant, no related submittals and grants.

5.7 Laboratory Facility
        The test facility is recognized, certified, or accredited by the following organizations:
         FCC - Registration No.: 727551
        Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
        (Federal Communications Commission). The Registration No. is 727551.
         IC - Registration No.: 10106A-1
        The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
        Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
        with Registration No.: 10106A-1.
         CNAS - Registration No.: CNAS L6048
        Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
        Requirements for the Competence of Testing and Calibration laboratories for the competence of
        testing. The Registration No. is CNAS L6048.
         A2LA - Registration No.: 4346.01
        This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
        17025:2005 General requirements for the competence of testing and calibration laboratories. The test
        scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf

5.8 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bao’an District, Shenzhen, Guangdong, China
        Tel: +86-755-23118282, Fax: +86-755-23116366
        Email: info@ccis-cb.com, Website: http://www.ccis-cb.com




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1811022
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                        Page 6 of 18


                                                                                    Report No: CCISE181102203

5.9 Test Instruments list
 Radiated Emission:
                                                                                          Cal. Date       Cal. Due date
    Test Equipment             Manufacturer            Model No.          Serial No.
                                                                                         (mm-dd-yy)        (mm-dd-yy)
        3m SAC                  SAEMC                  9m*6m*6m              966         07-22-2017        07-21-2020
     Loop Antenna            SCHWARZBECK              FMZB1519B             00044        03-16-2018        03-15-2019
   BiConiLog Antenna         SCHWARZBECK               VULB9163              497         03-16-2018        03-15-2019
     Horn Antenna            SCHWARZBECK              BBHA9120D              916         03-16-2018        03-15-2019
     Horn Antenna            SCHWARZBECK              BBHA9120D              1805        06-22-2017        06-21-2020
                                                                                         11-21-2017        11-20-2018
      Horn Antenna           SCHWARZBECK              BBHA 9170          BBHA9170582
                                                                                         11-21-2018        11-20-2019
   EMI Test Software             AUDIX                    E3                        Version: 6.110919b
     Pre-amplifier                 HP                   8447D            2944A09358     03-07-2018         03-06-2019
     Pre-amplifier                 CD                  PAP-1G18             11804       03-07-2018         03-06-2019
   Spectrum analyzer         Rohde & Schwarz            FSP30              101454       03-07-2018         03-06-2019
                                                                                       11-21-2017          11-20-2018
   Spectrum analyzer         Rohde & Schwarz             FSP40             100363
                                                                                       11-21-2018          11-20-2019
    EMI Test Receiver        Rohde & Schwarz           ESRP7                101070       03-07-2018        03-06-2019
         Cable                   ZDECL              Z108-NJ-NJ-81          1608458       03-07-2018        03-06-2019
         Cable                MICRO-COAX              MFR64639             K10742-5      03-07-2018        03-06-2019
         Cable                  SUHNER              SUCOFLEX100           58193/4PE      03-07-2018        03-06-2019


 Conducted Emission:
                                                                                          Cal. Date       Cal. Due date
    Test Equipment            Manufacturer             Model No.          Serial No.
                                                                                        (mm-dd-yy)         (mm-dd-yy)
   EMI Test Receiver        Rohde & Schwarz             ESCI               101189        03-07-2018        03-06-2019
     Pulse Limiter          SCHWARZBECK              OSRAM 2306             9731         03-07-2018        03-06-2019
         LISN                   CHASE                 MN2050D               1447         03-19-2018        03-18-2019
         LISN               Rohde & Schwarz           ESH3-Z5            8438621/010     07-21-2018        07-20-2019
        Cable                     HP                   10503A                N/A         03-07-2018        03-06-2019
   EMI Test Software            AUDIX                    E3                          Version: 6.110919b




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1811022
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                Page 7 of 18


                                                                               Report No: CCISE181102203

6      Test results and Measurement Data
6.1 Conducted Emission
        Test Requirement:                FCC Part 15 B Section 15.107
        Test Method:                     ANSI C63.4:2014
        Test Frequency Range:            150kHz to 30MHz
        Class / Severity:                Class B                 Class B
        Receiver setup:                  RBW=9kHz, VBW=30kHz
        Limit:                                                                         Limit (dBµV)
                                           Frequency range (MHz)
                                                                           Quasi-peak               Average
                                                  0.15-0.5                   66 to 56*              56 to 46*
                                                    0.5-5                       56                     46
                                                   0.5-30                       60                     50
                                         * Decreases with the logarithm of the frequency.
        Test setup:




        Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                            line impedance stabilization network(L.I.S.N.). The provide a
                                            50ohm/50uH coupling impedance for the measuring equipment.
                                         2. The peripheral devices are also connected to the main power through
                                            a LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                            termination. (Please refers to the block diagram of the test setup and
                                            photographs).
                                         3. Both sides of A.C. line are checked for maximum conducted
                                            interference. In order to find the maximum emission, the relative
                                            positions of equipment and all of the interface cables must be changed
                                            according to ANSI C63.4: 2014 on conducted measurement.
        Test environment:                Temp.:       23 C         Humid.:   56%         Press.:    101kPa
        Test Instruments:                Refer to section 5.9 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1811022
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 8 of 18


CCIS                                                                                                Report No: CCISE181102203

Measurement data:
Product name:                 1.8 inch Feature Phone                          Product model:               B3S
Test by:                      YT                                              Test mode:                   PC mode

Test frequency:               150 kHz ~ 30 MHz                                Phase:                       Line

Test voltage:                 AC 120 V/60 Hz                                  Environment:                Temp: 22.5°C         Huni: 55%


      so Level (dBuV)


      70

      60\                                                                                         FCC PaRT15 B op
                                                                                                flid
      50| ;                                                                                                              ECC PA§T151B AV
                                                                                                                    7           )
      40(1                A                                                                4          6              t         it        if
              ..                                                                         Hilntnat io.                               /
      30      J ‘llvq \/           *         ‘              l             UA p*flm [';‘;]If“i‘\vl I E [ ]‘\               w
      20              UAAA                                        I           '\     }‘\ mt U
                      J       V 1%@«&,»‘&1 ['|                                     "‘"                        J
      10

          0


     * A5       .2                     .5               1               2                       5                   10              20        30
 Fewnsu                                                           Frequency (MHz)

                               Read         LISN        Cable                      Limit       Over
                     Freq     Level Factor               Loss         Level         Line    Limit Remark

                       NBz     dBu?y             dB _       dB         dBu¥ —dBu¥                db               =====—
      1              0.158    26.28          O.17T      10.77         37.22        55.56 —18. 34 Average
      2              O.162    36.21         O.iT        I10.7T9       q6.21        65.3 —19.13 QP
      3              0.258    24.57         0.14        10.75         35.46        §1.51 —16.05 Average
     4              3.603     29.04         0.17        10.90         40.11        56.00   —15.89         qP
     5              4.092     26.47         0.18        10.89         37.54        46.00    —8.46         Average
     6              5.898     29.50         0.23        10.82         40.55        60.00   —19.45         QP
     T             10.019     30.93         0.32        10.94         42.19        60.00   —17.81         QP
     8             10.179     27.12         0.32        10.94         38.38        50.00   —11.62         Average
     9             16.839     36.73         0.30        10.91         47.94        60.00   —12.06         qP
    10             17.291     30.82         0.30        10.91         42.03        50.00    —7.97         Average
    11             23.018     32.95         0.31        10.89         44.15        60.00   —15.85         qP
    12             23.018     30.32         0.31        10.89         41.52        50.00    —8.48         Average


Notes:
1. An initial pre—scan was performed on the line and neutral lines with peak detector.
2. Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                      Project No.: CCISE1811022
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                         Page 9 of 18


c c I s                                                                                 Report No: CCISE181102203


Product name:               1.8 inch Feature Phone                 Product model:             B3S
Test by:                    YT                                     Test mode:                 PC mode

Test frequency:             150 kHz ~ 30 MHz                       Phase:                     Neutral

Test voltage:               AC 120 V/60 Hz                         Environment:               Temp: 22.5°C               Huni: 55%

     80 Level (dBuV)


     70
     60                                                                                                    FCC PART15 B QP

                                                                                                           FCC PART1SB AV
     501 —3!          —3                                                                                             M         i
     401              f                                                     5                        3          15              iB
             \         |                                                                  d          I                         )\


     anl|—            NNA1JcLJU ol                                               OO                                                  A
     *JY '\“"\\ ” )YA                                                       M% mP 1!1"?!!?‘\“: ¥ “l‘rif
                                                                             hunaimnt
                                                                                                                          Wl \

     10

       0


     ‘10.15      2                   .5           1            2                    5                 10                  20         30
Hrawsay                                                   Frequency (MHz)


                             Read   LISN         Cable             Limit          Over
                     Freq   Level Factor           Loss   Level      Line       Limit Remark

                     ~NHz    dBu¥y          dB        db dbuvy      dBu¥ —db_
     1            0.158     27.04         0.98   10.77    38.79    55.56    —16.77       Average
     2            0.190     33.70         0.93   10.76    45.39    64.02    —18.63       QP
     3            0.258     32.99         0.95   10.75    44.69    61.51    —16.82       QP
     4            0.258     26.03         0.95   10.75    37.73    §1.51    —13.78       Average
     5            3.584     24.66         1.00   10.90    36.56    56.00    —19.44       QP
     6            6.319     18. 89        1.02   10.81    30.72    50.00    —19.28       Average
     %            9.552     22.37         1.02   10.92    34.31    50.00    —15.69       Average
     8            9. 809    26. 39        1.02   10.93    38.34    60.00    —21.66       qP
     9           16.486     26.75         0.83   10.91    38.49    50.00    —11.51       Average
    10           16.573     38.15         0.83   10.91    49.89    60.00    —10.11       QP
    11           23.018     33.86         0.68   10.89    45.43    60.00    —14.57       QP
    12           23.140     26.62         0.68   10.89    38.19    50.00    —11.81       Average


Notes:
1. An initial pre—scan was performed on the line and neutral lines with peak detector.
2. Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1811022
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                               Page 10 of 18


                                                                           Report No: CCISE181102203

6.2 Radiated Emission
       Test Requirement:                 FCC Part 15 B Section 15.109
       Test Method:                      ANSI C63.4:2014
       Test Frequency Range:             30MHz to 6000MHz
       Test site:                        Measurement Distance: 3m (Semi-Anechoic Chamber)
       Receiver setup:                    Frequency       Detector        RBW     VBW          Remark
                                         30MHz-1GHz      Quasi-peak      120kHz  300kHz    Quasi-peak Value
                                                           Peak           1MHz    3MHz       Peak Value
                                         Above 1GHz
                                                           RMS            1MHz    3MHz      Average Value
       Limit:                                 Frequency          Limit (dBuV/m @3m)          Remark
                                            30MHz-88MHz                   40.0          Quasi-peak Value
                                           88MHz-216MHz                   43.5          Quasi-peak Value
                                           216MHz-960MHz                  46.0          Quasi-peak Value
                                            960MHz-1GHz                   54.0          Quasi-peak Value
                                                                          54.0            Average Value
                                             Above 1GHz
                                                                          74.0             Peak Value
       Test setup:                       Below 1GHz




                                         Above 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                      Project No.: CCISE1811022
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                     Page 11 of 18


                                                                               Report No: CCISE181102203


       Test Procedure:                  1. The EUT was placed on the top of a rotating table 0.8 meters above the
                                           ground at a 3 meter semi-anechoic camber. The table was rotated 360
                                           degrees to determine the position of the highest radiation.
                                        2. The EUT was set 3 meters away from the interference-receiving
                                           antenna, which was mounted on the top of a variable-height antenna
                                           tower.
                                        3. The antenna height is varied from one meter to four meters above the
                                           ground to determine the maximum value of the field strength. Both
                                           horizontal and vertical polarizations of the antenna are set to make the
                                           measurement.
                                        4. For each suspected emission, the EUT was arranged to its worst case
                                           and then the antenna was tuned to heights from 1 meter to 4 meters
                                           and the rotatable table was turned from 0 degrees to 360 degrees to
                                           find the maximum reading.
                                        5. The test-receiver system was set to Peak Detect Function and Specified
                                           Bandwidth with Maximum Hold Mode.
                                        6. If the emission level of the EUT in peak mode was 10dB lower than the
                                           limit specified, then testing could be stopped and the peak values of the
                                           EUT would be reported. Otherwise the emissions that did not have 10dB
                                           margin would be re-tested one by one using peak, quasi-peak or
                                           average method as specified and then reported in a data sheet.
       Test environment:                Temp.:       25 C         Humid.:     55%         Press.:    1 01kPa
       Test Instruments:                Refer to section 5.9 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed
       Remark:                          All of the observed value above 6GHz ware the niose floor , which were no
                                        recorded




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1811022
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 12 of 18


c c I s                                                                                                                   Report No: CCISE181102203

Measurement Data:
Below 1GHz:

Product Name:                                      1.8 inch Feature Phone                                 Product Model:       B3S
Test By:                                           YT                                                     Test mode:           PC mode

Test Frequency:                                    30 MHz ~ 1 GHz                                         Polarization:        Vertical

Test Voltage:                                      AC 120/60Hz                                            Environment:         Temp: 24°C       Huni: 57%

                   80Level (dBuVim)


                   70

                   60
                                                                                                                                    FCC PART1S CLASS 8
                   50

                   40

                   30

                   20

                   10


                        30                    50                     100                                 200                        500             1000
                                                                                                Frequency (MHz)

                                                Read&ntenna          Cable Preamp                                 Limit      Over
                                       Freq    Level Factor           Loss Factor                        Level     Line     Linit Remark

                                       MHz          dBu¥    dB/m                           dB       dB dBu¥/m dBu¥/m           dB
                                                                                          41     29.75    22.50   40.00    —17.50   qP
     oo on & Ga ho +




                                                                      Lo Co ho No i+ ++




                                                                                          .99    29.50    24.50   43.50    —19.00   qP
                                                                                          .64    29.07    24.73   43.50    —18.77   9P
                                                                                          %      28.59    23.38   46.00    —22.62   qP
                             ho
                             to
                                  to
                                       t
                                        co
                                        —2

                                               to
                                                   o
                                                   i
                                                   co

                                                           ho
                                                                w
                                                                —i



                                                                                          co
                                                                                           no




                                                                                          .09    28.63    26.66   46.00    —19.34   QP
                                                                                          .94    28.93    33.29   46.00    —12.71   QP


Remark:
1.    Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.     The emission levels of otherfrequencies are very lower than the limit and not show in test report,




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                    Project No.: CCISE1811022
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                     Page 13 of 18


CCIS                                                                                    Report No: CCISE181102203



Product Name:              1.8 inch Feature Phone                   Product Model:             B3S
Test By:                   YT                                       Test mode:                 PC mode

Test Frequency:            30 MHz ~ 1 GHz                           Polarization:              Horizontal

Test Voltage:              AC 120/60Hz                              Environment:              Temp: 24°C      Huni: 57%

      80Level (dBuVim)


      70

      60
                                                                                                 FCC PART1S CLASS$ 8
      50

      40

      30

      20

      10


           30                                 100                   200                          500               1000
                                                        Frequency (MHz)


                            Read&ntenna         Cable Preamp                   Limit      Over
                  Freq     Level Factor           Loss Factor       Level        Line    Linit Remark

                    NBz _ dBu¥y        db/m         db _ dB dBu¥/nm dBu¥/m                    dB ~          C
      1          66.266    38.12      10.27      1.41     29.75     20.05      40.00    —19.95    QP
      2         167.824    46.50       9.34      2.64     29.07     29.41      43.50    —14.09    qP
      3         216.024    42.47      12.12      2.85     28.73     28.71      46.00    —17.29    QP
      4         287.990    38.95      13.53      2.91     28.47     26.90      46.00    —19.10    qP
      5         365.539    39.76      14.89      3.09     28.63     29.11      46.00    —16.89    QP
      6         696.857    36.77      19.80      4.16     28.68     32.05      46.00    —13.95    QP


Remark:
1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of otherfrequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE1811022
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                   Page 14 of 18


c c I s                                                                                Report No: CCISE181102203

Above 1GHz:
Product Name:                 1.8 inch Feature Phone                Product Model:             B3S
Test By:                      YT                                    Test mode:                 PC mode

Test Frequency:               1 GHz ~ 6 GHz                         Polarization:              Vertical

Test Voltage:                 AC 120/60Hz                           Environment:               Temp: 24°C        Huni: 57%


          80Level (dBuVim)
                                                                                                     FCC PART 15 (PK)
          70

          60
                                                                                                     FCC PART 15 (AV)
          50




               1000    1200        1500           2000                                                    5000    6000
                                                         Frequency (MHz)

                               Readintenna     Cable Preamp                   Limit      Over
                      Freq    Level Factor        Loss Factor      Level        Line    Linit Remark

            """"NBz dBu¥y dB/m —                   db _ dB dBu¥/m dBu¥/m —dB —
      1         2977.790      48.10   28.56      5.33    41.52     40.47      74.00    —33.53    Peak
      2         2977.790      38.23   28.56      5.33    41.52     30.60      54.00    —23.40    Average
      3          4185.457     4T.51   30.55      6.37    41.81     42.62      74.00    —31.38    Peak
      4          4185.457     36.59   30.55      6.37    41.81     31.70      54.00    —22.30    Average
      §         §407.773      47.31   32.31      T.13    41.86     44.89      74.00    —29.11    Peak
      6         §407.773      37.63   32.31      T.13    41.86     35.21      54.00    —18.79    Average


Remark:
1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of otherfrequencies are very lower than the limit and not show in test report,




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE1811022
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                      Page 15 of 18


CCIS                                                                                   Report No: CCISE181102203



Product Name:              1.8 inch Feature Phone                    Product Model:             B3S
Test By:                   YT                                        Test mode:                 PC mode

Test Frequency:            1 GHz ~ 6 GHz                             Polarization:              Horizontal

Test Voltage:              AC 120/60Hz                               Environment:              Temp: 24°C            Huni: 57%


     80Level (dBu\Vim)
                                                                                                           FCC PART 15 (PK)
     70

     60
                                                                                                           FCC PART 15 (AV)
     50                                                                                                          |
                                                                                                      3          3

     40

     30

     20

      10


           1000   1200            1500            2000                                                          5000      6000
                                                         Frequency (MHz)


                          Readintenna         Cable Preamp                Limit      Over
                  Freq   Level Factor          Loss Factor      Level      Line     Limit Remark

                  NHz     dBuvy      dB/m —      dB        dB dBu¥/m dBu¥/m             dB
      1.     3159.171    48.03      28.70      5.41   41.43     40.71     74.00 —33.29 Peak
      2      3159.171    38.20      28.70      5.41   41.43     30.88     54.00 —23.12 Average
      3       4276.423   46.88      30.71      6.52   41.87     42.24     74.00 —31.76 Peak
     40      4276.423    35.74      30.11      6.52   41.87     31.10     54.00 —22.90 Average
      5       4988.864   4T.16      31.88      6.93   41.88     44.09     74.00 —29.91 Peak
      6       4988.864   37.33      31.88      6.93   41.88     34.26     54.00 —19.74 Average



Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1811022
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                          Page 16 of 18



Document Created: 2018-12-10 15:02:00
Document Modified: 2018-12-10 15:02:00

© 2024 FCC.report