Test report

FCC ID: O55181919

Test Report

Download: PDF
FCCID_4392446

                          Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                                  Report No: CCISE190701903

1        Cover Page

                                      FCC REPORT
Applicant:                                 SWAGTEK

Address of Applicant:                      10205 NW 19th St. Suite 101, Miami, FL, 33172

Equipment Under Test (EUT)

    Product Name:                          1.8 inch 3G Bar Phone

    Model No.:                             Z3G, OPAL, Q3G

    Trade mark:                            LOGIC, iSWAG, UNONU

FCC ID:                                    O55181919

Applicable standards:                      FCC CFR Title 47 Part 15 Subpart B

Date of sample receipt:                    15 Jul., 2019

Date of Test:                              16 Jul., to 31 Jul., 2019

Date of report issued:                     2 Aug., 2019

Test Result:                               PASS *
  * In the configuration tested, the EUT complied with the standards specified above.




 Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.


                                                                                 Report No: CCISE190701903

2      Version
      Version No.                            Date                                  Description
             00                         2 Aug., 2019                                 Original




    Tested by:                                                           Date:          2 Aug., 2019

                                       Test Engineer

    Reviewed by:                                                         Date:          2 Aug., 2019

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1907019
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                         Page 2 of 18


                                                                                                                            Report No: CCISE190701903

3         Contents
                                                                                                                                                                                 Page
1     COVER PAGE ................................................................................................................................................... 1
2     VERSION ........................................................................................................................................................... 2
3     CONTENTS ....................................................................................................................................................... 3
4     TEST SUMMARY .............................................................................................................................................. 4
5     GENERAL INFORMATION .............................................................................................................................. 5
    5.1    CLIENT INFORMATION ...................................................................................................................................................... 5
    5.2    GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
    5.3    TEST MODE.................................................................................................................................................................... 5
    5.4    MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
    5.5    DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
    5.6    RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................... 6
    5.7    DESCRIPTION OF CABLE USED ............................................................................................................................................ 6
    5.8    LABORATORY FACILITY ...................................................................................................................................................... 6
    5.9    LABORATORY LOCATION ................................................................................................................................................... 6
    5.10      TEST INSTRUMENTS LIST ............................................................................................................................................... 7
6     TEST RESULTS AND MEASUREMENT DATA ............................................................................................. 8
    6.1    CONDUCTED EMISSION ..................................................................................................................................................... 8
    6.2    RADIATED EMISSION ...................................................................................................................................................... 11
7     TEST SETUP PHOTO..................................................................................................................................... 17
8     EUT CONSTRUCTIONAL DETAILS.............................................................................................................. 18




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                               Project No.: CCISE1907019
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                                        Page 3 of 18


                                                                              Report No: CCISE190701903

4      Test Summary
                 Test Item                                Section in CFR 47                 Result
           Conducted Emission                                 Part 15.107                    Pass
            Radiated Emission                                 Part 15.109                    Pass
 Remark:
 Pass: The EUT complies with the essential requirements in the standard.
 N/A: The EUT not applicable of the test item.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                       Project No.: CCISE1907019
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                      Page 4 of 18


CCIS                                                                             Report No: CCISE190701903

5       General Information
5.1 Client Information
        Applicant:                              SWAGTEK
        Address:                                 10205 NW 19th St. Suite 101, Miami, FL, 33172
        Manufacturer/Factory:                   SWAGTEK
        Address:                                 10205 NW 19th St. Suite 101, Miami, FL, 33172

5.2 General Description of E.U.T.
        Product Name:                            1.8 inch 3G Bar Phone
        Model No.:                               23G, OPAL, Q3G
        Power supply:                            Rechargeable Li—ion Battery DC3.7V, 800mAh
                                                 Model: XCMO4—X0505000YU CHARGER | CARGADOR
        AC adapter:                              Input: AC100—240V, 50/60Hz, 0.15A
                                                 Output: DC 5.0V, 500mA
        Test Sample Condition:                  The test samples were provided in good working order with no
                                                visible defects.
        Remarks:                                 item No.: Z3G, OPAL, Q3G, were identical inside, the electrical
                                                 circuit design, layout, components used and internal wiring.
                                                 Z3G model corresponds to the trademark LOGIC.
                                                 OPAL model correspond to the trademark ISWAG.
                                                 Q3G model corresponds to the trademark UNONU.


5.3 Test Mode
          Operating mode                 Detail description
              PC mode                    Keep the EUT in Downloading mode(Worst case)
    Charging+Recording mode              Keep the EUT in Charging+Recording mode
      Charging+Playing mode              Keep the EUT in Charging+Playing mode
              FM mode                    Keep the EUT in FM receiver mode
             GPS mode                    Keep the EUT in GPS receiver mode
 The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
 vertical polarities were performed. During the test, each emission was maximized by: having the EUT
 continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
 typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable,
 varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst—case
 are shown in Test Results of the following pages.

5.4 Measurement Uncertainty
                       Parameters                                            Expanded Uncertainty
        Conducted Emission (9kHz ~ 3OMHz)                                       +1.60 dB (k=2)
         Radiated Emission (@kHz ~ SOMHz)                                       +3.12 dB (k=2)
       Radiated Emission (3OMHz ~ 1000MHz)                                      +4.32 dB (k=2)
         Radiated Emission (1GHz ~ 18GHz)                                       +5.38 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                       +3.36 dB (k=2)




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1907019
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                              Page 5 of 18


CCIS                                                                             Report No: CCISE190701903

5.5 Description of Support Units
     Manufacturer                 Description                 Model           Serial Number          FCC ID/DeC

           DELL                        PC                 OPTIPLEX745               N/A                  DoC
           DELL                    MONITOR                   E178FPG                N/A                  DoC
           DELL                   KEYBOARD                   SK—8115                N/A                  DoC
           DELL                     MOUSE                    MOCSUO                 N/A                  DoC
        LENOVO                       Laptop                   SL510              2B47A65                 DoC

5.6 Related Submittal(s) / Grant (s)
       This is an original grant, no related submittals and grants.

5.7 Description of Cable Used
        Cable Type                     Description                 Length            From                 To
   Detached USB Cable                   Unshielded                  1.0m              EUT             PC/Adapter

5.8 Laboratory Facility
        The test facility is recognized, certified, or accredited by the following organizations:
        ® FCC — Designation No.: CN1211
       Shenzhen Zhongiian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by
       FCC(Federal Communications Commission). The test firm Registration No. is 727551.
        @ ISED — CAB identifier.: CNOO21
       The 3m Semi—anechoic chamber of Shenzhen Zhongiian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
       Registration No.: 10106A—1.
        ©@ CNAS — Registration No.: CNAS L6048
       Shenzhen Zhongiian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.
       ®     A2LA — Registration No.: 4346.01
        This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
        17025:2005 General requirements for the competence of testing and calibration laboratories. The test
        scope can be found as below link: https://portal.a2la. org/scopepdt/4346—01.pdf

5.9 Laboratory Location
       Shenzhen Zhongjian Nanfang Testing Co., Ltd.
       Address: No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
       Bac‘an District, Shenzhen, Guangdong, China
       Tel: +86—755—23118282, Fax: +86—755—23116366
       Email: info@ccis—cb.com, Website: http://www.ccis—cb.com




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1907019
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                             Page 6 of 18


                                                                                  Report No: CCISE190701903

5.10 Test Instruments list
 Radiated Emission:
                                                                                            Cal. Date       Cal. Due date
    Test Equipment            Manufacturer            Model No.           Serial No.
                                                                                          (mm-dd-yy)         (mm-dd-yy)
        3m SAC                  SAEMC                 9m*6m*6m                966          07-22-2017         07-21-2020
     Loop Antenna            SCHWARZBECK             FMZB1519B              00044          03-18-2019         03-17-2020
   BiConiLog Antenna         SCHWARZBECK              VULB9163                497          03-18-2019         03-17-2020
     Horn Antenna            SCHWARZBECK             BBHA9120D                916          03-18-2019         03-17-2020
     Horn Antenna            SCHWARZBECK             BBHA9120D               1805          06-22-2017         06-21-2020
     Horn Antenna            SCHWARZBECK             BBHA 9170           BBHA9170582      11-21-2018         11-20-2019
   EMI Test Software             AUDIX                   E3                            Version: 6.110919b
     Pre-amplifier                 HP                  8447D             2944A09358       03-18-2019         03-17-2020
     Pre-amplifier                 CD                 PAP-1G18              11804         03-18-2019         03-17-2020
   Spectrum analyzer         Rohde & Schwarz           FSP30               101454         03-18-2019         03-17-2020
   Spectrum analyzer         Rohde & Schwarz           FSP40               100363         11-21-2018         11-20-2019
   EMI Test Receiver         Rohde & Schwarz           ESRP7                101070        03-18-2019         03-17-2020
        Cable                    ZDECL              Z108-NJ-NJ-81          1608458        03-18-2019         03-17-2020
        Cable                 MICRO-COAX              MFR64639             K10742-5       03-18-2019         03-17-2020
        Cable                   SUHNER              SUCOFLEX100           58193/4PE       03-18-2019         03-17-2020


 Conducted Emission:
                                                                                          Cal. Date         Cal. Due date
   Test Equipment            Manufacturer             Model No.           Serial No.
                                                                                        (mm-dd-yy)           (mm-dd-yy)
  EMI Test Receiver         Rohde & Schwarz             ESCI               101189        03-18-2019           03-17-2020
    Pulse Limiter           SCHWARZBECK              OSRAM 2306             9731         03-18-2019           03-17-2020
        LISN                    CHASE                 MN2050D               1447         03-18-2019           03-17-2020
                                                                                         07-21-2018           07-20-2019
         LISN               Rohde & Schwarz            ESH3-Z5           8438621/010
                                                                                         07-21-2019           07-20-2020
       Cable                      HP                    10503A               N/A         03-18-2019           03-17-2020
  EMI Test Software              AUDIX                    E3                         Version: 6.110919b




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1907019
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                  Page 7 of 18


                                                                               Report No: CCISE190701903

6      Test results and Measurement Data
6.1 Conducted Emission
       Test Requirement:                FCC Part 15 B Section 15.107
       Test Method:                     ANSI C63.4:2014
       Test Frequency Range:            150kHz to 30MHz
       Class / Severity:                Class B                  Class B
       Receiver setup:                  RBW=9kHz, VBW=30kHz
       Limit:                                                                        Limit (dBµV)
                                          Frequency range (MHz)
                                                                          Quasi-peak                 Average
                                                 0.15-0.5                   66 to 56*                56 to 46*
                                                   0.5-5                       56                       46
                                                  0.5-30                       60                       50
                                        * Decreases with the logarithm of the frequency.
       Test setup:




       Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                           line impedance stabilization network(L.I.S.N.). The provide a
                                           50ohm/50uH coupling impedance for the measuring equipment.
                                        2. The peripheral devices are also connected to the main power through a
                                           LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                           termination. (Please refers to the block diagram of the test setup and
                                           photographs).
                                        3. Both sides of A.C. line are checked for maximum conducted
                                           interference. In order to find the maximum emission, the relative
                                           positions of equipment and all of the interface cables must be changed
                                           according to ANSI C63.4: 2014 on conducted measurement.
       Test environment:                Temp.:        22.5 C       Humid.:   55%          Press.:    101kPa
       Test Instruments:                Refer to section 5.10 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1907019
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                             Page 8 of 18


c c I s                                                                                Report No: CCISE190701903

Measurement data:
 Product name:               1.8 inch 3G Bar Phone             Product model:              23G
 Test by:                    Janet                             Test mode:                  PC mode

 Test frequency:             150 kHz ~ 30 MHz                  Phase:                      Line

 Test voltage:               AC 120 V/60 Hz                    Environment:                Temp: 22.5°C        Huni: 55%


       so Level (dBuV)


       70
       60\
                                                                                    FCC PART15 B OP
                                                                                    e
            —_L_
       50    4                                                                                         FCC PART15B AV

                                                                                           12
       40 3                          4
       30; ¢V;


       n Nlnk[ ho ol
       10
                                                                                                                    J o

            15 .2                 5              1              2                  5              10           20       30
 Hace:3                                                  Frequency (MHz)


                              Read   LISN              Cable                     Limit       Over
                     Freq    Level Factor               Loss        Level          Line     Linmit Remark

            ______NHz        dBu¥y — dB _ dB dBu¥ dBu¥                                            dB
   1                0. 170   36.89        —0.43        10.77        47.23        64.94     —11.71        QP
   2                0.170    26.72        —0.43        10.77        37.06        54.94     —17.88        Average
   3                0.219    19.74        —0.40        10.76        30.10        52.88     —22.78        Average
   4                0.527    21.87f       —0.39        10.76        38.24        56.00     —11.16        QP
   5                0.527    16.85        —0.39        10.76        27.22        46.00     —18.78        Average
   6                1.037    24.178       —0.38        10.87        35.27        56.00     —20.73        qP
   T                1.753    11.64        —0.40        10.94        22.18        46.00     —23.82        Average
   8                3.328    31.38        —0.45        10.91        41.84        56.00     —14.16        QP
   9                3.381    20.06        —0.45        10.91        30.52        46.00     —15.48        Average
  10                4.158    36.52        —O.47        10.88        46.93        56.00      —9.07        qP
  11                4.269    24.10        —O.47        10.88        34.51        46.00     —11.49        Average
  12                7.687    31.36        —0.55        10.83        41.64.       60.00     —18s.36       QP

 Notes:
 1. An initial pre—scan was performed on the line and neutral lines with peak detector.
 2.   Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE1907019
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                   Page 9 of 18


c c I s                                                                              Report No: CCISE190701903


 Product name:               1.8 inch 3G Bar Phone             Product model:               Z23G
Test by:                     Janet                             Test mode:                   PC mode

Test frequency:              150 kHz ~ 30 MHz                  Phase:                       Neutral

Test voltage:                AC 120 V/6O Hz                    Environment:                 Temp: 22.5°C        Huni: 55%


          go Level (dBuV)


          70

          60                                                                                           FCC PART1S 8 OP

          50                                                                 g9                       FCC PART15B AV
                                                                                            12
          40}%—
          30


          20

          10


      0.15 12                    :16            1             2
 Hace:4                                                 Frequency (MHz)


                               Read           LISN     Cable                      Linmnit         Over
                     Freq    Level Factor                  Loss     Level          Line       Limit Remark

               C       MHz     dBu¥           dB _            dB dBu¥ dBu¥                            dB         C
      1             0. 182   46.31        —0.69         10.77       56.39         64.42 —8.03 QP
      2             0. 186   35.01        —0.69         10.76       45.08         54.20 —9.12 Average
      3             0.206    27.10        —0.69         10.76       37.17         53.36 —16.19 Average
      4             0.238    40.24        —O.66         10.75       50.33         62.17 —11.84 qP
      5             0.246    26.23        —0.66         10.75       36.32         51.91 —15.59 Average
   6                0.527    17.74        —0.685        10.76       27.85         46.00 —18.15 Average
   T                3.623    38.99        —0.69         10.90       49.20         56.00 —6.80 qP
   8                3.943    41.18        —0.70         10.89       51.37         56.00 —4.63 qP
   9                4.180    41.62        —O.70         10.88#      51.80         56.00 —4.20 QP
  10                4.180    26.47        —0.70         10.88       36.65         46.00 —9.35 Average
  11                T.566    14.71        —0.76         10.83       24.78         50.00 —25.22 Average
  12                T.977    32.80        —0.76         10.85       42.89         60.00 —17.11 QP

 Notes:
 1. An initial pre—scan was performed on the line and neutral lines with peak detector.
 2.   Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1907019
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                    Page 10 of 18


                                                                         Report No: CCISE190701903

6.2 Radiated Emission
       Test Requirement:              FCC Part 15 B Section 15.109
       Test Method:                   ANSI C63.4:2014
       Test Frequency Range:          30MHz to 6000MHz
       Test site:                     Measurement Distance: 3m (Semi-Anechoic Chamber)
       Receiver setup:                  Frequency       Detector        RBW      VBW           Remark
                                       30MHz-1GHz      Quasi-peak      120kHz   300kHz    Quasi-peak Value
                                                         Peak           1MHz     3MHz       Peak Value
                                       Above 1GHz
                                                         RMS            1MHz     3MHz      Average Value
       Limit:                                Frequency           Limit (dBuV/m @3m)          Remark
                                           30MHz-88MHz                    40.0           Quasi-peak Value
                                          88MHz-216MHz                    43.5           Quasi-peak Value
                                         216MHz-960MHz                    46.0           Quasi-peak Value
                                           960MHz-1GHz                    54.0           Quasi-peak Value
                                                                          54.0            Average Value
                                            Above 1GHz
                                                                          74.0             Peak Value
       Test setup:                    Below 1GHz




                                      Above 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.: CCISE1907019
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                    Page 11 of 18


                                                                               Report No: CCISE190701903


        Test Procedure:                 1. The EUT was placed on the top of a rotating table 0.8 meters above
                                           the ground at a 3 meter semi-anechoic camber. The table was rotated
                                           360 degrees to determine the position of the highest radiation.
                                        2. The EUT was set 3 meters away from the interference-receiving
                                           antenna, which was mounted on the top of a variable-height antenna
                                           tower.
                                        3. The antenna height is varied from one meter to four meters above the
                                           ground to determine the maximum value of the field strength. Both
                                           horizontal and vertical polarizations of the antenna are set to make the
                                           measurement.
                                        4. For each suspected emission, the EUT was arranged to its worst case
                                           and then the antenna was tuned to heights from 1 meter to 4 meters
                                           and the rotatable table was turned from 0 degrees to 360 degrees to
                                           find the maximum reading.
                                        5. The test-receiver system was set to Peak Detect Function and
                                           Specified Bandwidth with Maximum Hold Mode.
                                        6. If the emission level of the EUT in peak mode was 10dB lower than the
                                           limit specified, then testing could be stopped and the peak values of
                                           the EUT would be reported. Otherwise the emissions that did not have
                                           10dB margin would be re-tested one by one using peak, quasi-peak or
                                           average method as specified and then reported in a data sheet.
        Test environment:               Temp.:        24 C         Humid.:    57%         Press.:    1 01kPa
        Test Instruments:               Refer to section 5.10 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed
        Remark:                         All of the observed value above 6GHz ware the niose floor , which were
                                        no recorded




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1907019
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 12 of 18


CCIS                                                                                    Report No: CCISE190701903

Measurement Data:
Below 1GHz:

 Product Name:               1.8 inch 3G Bar Phone                     Product Model:            23G

Test By:                     Janet                                     Test mode:                PC mode

Test Frequency:              30 MHz ~ 1 GHz                            Polarization:             Vertical

Test Voltage:                AC 120/60Hz                               Environment:              Temp: 24°C      Huni: 57%


  so Level (dBuVim)


  70

  60
                                                                                                     FCC PART1S CLASS$ B
  50

  40

  30

  20

  10


      G30              50                     100                    200                             500               1000
                                                         Frequency (MHz)




                             Readintenna            Cable Preamp                        Linit        Over
                 Freq       Level Factor              Loss Factor           Level        Line       Linit Remark

        ______NHz dBu¥ dB/m —db _ dB dBu¥/m dBu¥/m —dB
  1           64.887        50.96         9.60        1.38      29.T6       32.18       40.00       —7.82 qQP
  2          92.462         44.175      10.65         2.03      29.56       27.87       43.50 —15.63 QP
  3         150.011         47.50        8.90         2.52      29.22       29.70       43.50 —13.80 qP
 4          194.453         52.89       10.43        2.83       28.87       37.28       43.50 —6.22 qP
 5          480.528         48.70       17.52        3.46       28.92       40.76       46.00 —5.24 QP
 6          116.682         38.42       20.48        4.24       28.60       34.54       46.00 —11.46 qP



 Remark:
 1.    Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preampiifier Factor.
 2.    The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1907019
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                     Page 13 of 18


CCIS                                                                                   Report No: CCISE190701903


 Product Name:              1.8 inch 3G Bar Phone                     Product Model:            Z3G

Test By:                    Janet                                     Test mode:                PC mode

Test Frequency:             30 MHz ~ 1 GHz                            Polarization:             Horizontal

Test Voltage:               AC 120/60Hz                               Environment:              Temp: 24°C          Huni: 57%



      Level (dBuVim)
 80

 70

 60
                                                                                                   FCC PART1S CLASS$ B




      30             50                     100                     200                            500                   1000
                                                        Frequency (MHz)




                           Readintenna             Cable Preamp                        Linit        Over
                Freq      Level Factor               Loss Factor           Level        Line       Limit Remark

             _NHz           dBu¥         dB/m _         dB _dB dBu¥/m dBu¥/nm                               dB _                ~
 1         187.753        50.61        10.23         2.78      28.92       34.70       43.50 —8.80 qP
 2         195.822        S51.46       10.48         2.84      28.86       35.92       43.50 —7.58 qP
 3         239.987        43.80        12.30         2.82      28.59       30.33       46.00 —15.67 qP
 4         336.035        43.44        14.33         3.05      28.53       32.29       46.00 —13.71 QP
 5         480.528        46.69        17.52         3.46      28.92       38.75       46.00 —7.25 QP
 6         T21.726        42.68        20.49         4.26      28.58       38.85       46.00 —T.15 qP


 Remark:
1.    Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preampiifier Factor.
2.    The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1907019
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                        Page 14 of 18


CCIS                                                                                    Report No: CCISE190701903

Above 1GHz:
 Product Name:               1.8 inch 3G Bar Phone                     Product Model:            Z3G
 Test By:                    Janet                                     Test mode:                PC mode

 Test Frequency:             1 GHz ~6 GHz                              Polarization:             Vertical

 Test Voltage:               AC 120/60Hz                               Environment:              Temp: 24°C              Huni: 57%


       Level (dBuVim)
 80
                                                                                                        FCC PART 15 (PK)
 70

 60
                                                                                                        FCC PART 15 (AV)
 50


 40

 30

 20


 10


       1000     1200          1500                2000                                                            5000       6000
                                                         Frequency (MHz)



                             Readintenna            Cable Preamp                        Limit          Over
                  Freq     Level Factor              Loss Factor            Level         Line      Limit Remark

         _         NHz       dBu¥y        dB/nm          dB _        dB dBuV/m dBu¥/m —                      dB              CCC
   1         3058.908      45.81        28.51         5.37      41.48       40.14       74.00      —33.86         Peak
  2           3058.908     40.25        28.51         5.37      41.48       34.58       54.00      —19.42         Average
  3          4il1.131      45.78        30.32%        6.27      41.81       42.79       14.00      —31.21         Pesk
  40         41l1.131      40.31        30.32         6.27      41.81       37.32       54.00      —16.68         Average
  §           §152.386     46.68        31.76         7.05      41.93       46.10       74.00      —27.90         Peak
  6           5§152.386    40.24        31.76         7.05      41.93       39.66       54.00      —14.34         Average


 Remark:
 1.    Final Level = Receiver Read level + Antenna Factor + Cable Loss— Preamplifier Factor.
 2.    The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1907019
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                          Page 15 of 18


CCIS                                                                                    Report No: CCISE190701903


 Product Name:               1.8 inch 3G Bar Phone                     Product Model:            Z23G

Test By:                     Janet                                     Test mode:                PC mode

Test Frequency:              1 GHz ~6 GHz                              Polarization:             Horizontal

Test Voltage:                AC 120/60Hz                               Environment:              Temp: 24°C         Huni: 57%


 80Level (dBuVi/m)
                                                                                                           FCC PART 15 (PK)
 70

 60
                                                                                                           FCC PART 15 (AV)
 50                                                                                                                      5
                                                                                                 3
 40                                                                         i
 30


 20

 10


      01000    1200           1500                2000                                                          5000      6000
                                                         Frequency (MHz)

                             Readintenna            Cable Preamp                        Limit          Over
                 Freq       Level Factor              Loss Factor           Level        Line         Limit Remark

         """""WHz dBuvy dB/m — dB _ dB dBu¥/m dBu¥/m dB —
  1        2862.693         45.T5       28.22         5.20      41.61       39.41       74.00 —34.59 Peak
  2         2862.693        40.65       28.22         5.20      41.61       34.31       54.00 —19.69 Average
  3        3916.979         46.85       30.03         6.10      41.80       43.38       74.00 —30.62 Peak
  4           3916.979      41.22       30.03         6.10      41.80       37.75       54.00 —16.25 Average
  5           5675.819      47.88       32.64         T.55      41.89       48.88       74.00 —25.12 Peak
  6           5675.819      41.67       32.64         T.55      41.89       42.67       54.00 —11.33 Average

 Remark:
 1.    Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preampiifier Factor.
2.     The emission levels of other frequencies are very lower than the limit and not show in test report,




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                         Project No.: CCISE1907019
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                        Page 16 of 18



Document Created: 2019-08-06 11:59:51
Document Modified: 2019-08-06 11:59:51