RF Exposure

FCC ID: O5301526RX24G

RF Exposure Info

Download: PDF
FCCID_2662694

                       RF Exposure evaluation


According to KDB 447498 D01 General RF Exposure Guidance v05
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at
test separation distances ≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test
separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for
10-g extremity SAR, where
  f(GHz) is the RF channel transmit frequency in GHz
   Power and distance are rounded to the nearest mW and mm before
calculation
  The result is rounded to one decimal place for comparison


The worst case is as below: [at 2437 MHz, power is 7.46 dBm( 5.57 mW)
output power]


(5.57 mW /5mm) ·[√2.437 (GHz)]= 1.74 <3.0 for 1-g SAR


Then SAR evaluation is exempted.



Document Created: 2015-06-30 13:46:06
Document Modified: 2015-06-30 13:46:06

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC