3.5. Connections:                                                        Ensure that the paper is protruding from UNDERNEATH                                      Recommended brands:
    Turn the i7780 base off when connecting peripherals.                 the roll:                                                                                KANZAN .................... KF50       JUJO....................AF50KS-E
                                                                                                                                                                  KOEHLER..........KT55HS01              MITSUBISHI..............P6402
    The power supply must be connected last, only after all
                                                                                                                                                                  Thermal paper should NOT be exposed to vinyl, plastics, adhesives,
    the other connections are made.                                                                                                                               shrink-wraps, wet-toner copies or certain carbon papers, office light
                                                                                                                                                                  UV light, high humidity and temperature (above 65%, 25°C or 77°F)
                                                                                                                                                                  for long periods of time.
                                                                                                                                                         8.       If you experience problems:
                                                                                                                                                                  Call one of the customer service centers listed below:
                                                                                                                                                                  In Canada:                          In the USA:
                      VERSATILE BASE                                                                                                                              TotalCARE                           Ingenico Inc.
                                                                      4. Close the cover, press it until it snaps. Press the “Paper                               6520 Gottardo Court                 TotalCARE
                                                                         feed” key to verify that paper feeds properly.                                           Mississauga, Ontario                1003 Mansell Road
                                                                                                                                                                  L5T 2A2                             Atlanta, GA 30076
                                                                 5.   Normal Operation:                                                                           1-888-900-8221 (905-795-8221)       1-800-435-3014 (770-594-6000)
                                                                                                                                                         US Federal Communications Commission (FCC) Warnings:
                                                                      Depending of the application installed in the terminals, the                       This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
                                                                      icons indicating battery charge level, Bluetooth signal                            the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this
                                                                                                                                                         equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
                        RADIO BASE                                    strength and terminal docking status can be displayed.                             energy and, if not installed and used in accordance with the installation guide, may cause harmful interference to radio
                                                                                                                                                         communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case
                                                                      To extend the battery life, the i7780 hand held goes into a                        the user will be required to correct the interference at his own expense.
    Maximum cable length is 2.5m.                                     stand-by mode when it is not on its base. To quickly power                         Warning: Changes or modifications not expressly approved by Ingenico could void the user’s authority to operate the
    • ETHERNET CONNECTION (versatile base only)                       on the hand held:                                                                           equipment.

    Turn off the versatile base and connect the Ethernet              • Press the green <ENTER> key, or                                                  Canadian Department of Communications (DOC) Warnings:
                                                                                                                                                         This digital apparatus does not exceed the Class B limits for radio noise emissions from the digital apparatus as set out
    cable (supplied with the terminal) to the port on the
                                                                      • Place the hand held briefly on the base.                                         in the radio interference regulations of the Canadian Department of Communications.
    Ethernet Plug-It module. Plug the other end of the cable                                                                                             RF Exposure Warning:
    into the hub or router.                                      6.   Cleaning procedure:                                                                 To comply with RF exposure requirements the base unit must be installed and operated with a separation distance of 20
                                                                                                                                                         cm or more between the device and all person's body (excluding extremities of hands, wrist and feet). The terminal unit
    • DIAL LINE CONNECTION                                            • The i7780 must be off for all cleaning operations.                               has been tested and meets RF exposure guidelines for hand held operation pursuant to FCC OET Bulletin 65
                                                                                                                                                         Supplement C ed. 01-01, IEEE 1528/D1.2 (2003) and Industry Canada RSS-102 (1999). The base and terminal units
    Plug the one end of a telephone cable (supplied with the          • Do not clean the i7780 with water but with a dry or only                         must not be co-located or operated in conjunction with any other antenna or transmitter.
                                                                                                                                                         For body worn operation, this device has been tested and meets FCC RF exposure guidelines when used with
                                                                                                                                                         accessories that contain no metal and that position the device a minimum of 10 mm from the body. Use of other
    terminal) into the port, and connect the other end of the             slightly damp cloth.                                                           accessories may not ensure compliance with FCC RF exposure guidelines.

    cable to a wall telephone jack.                                   • Do not use solvent, detergent or abrasive products.                              ACTA Revision Part 68

    • PHONE CONNECTION (radio base only)                              • If the terminal has battery recharging or communication                          This equipment complies with Part 68 of the FCC rules and the requirements adopted by the Administrative Council for
                                                                                                                                                         Terminal Attachments (ACTA). On the bottom of this equipment is a label that contains, among other information, a
                                                                                                                                                         product identifier in the format US: INBMM01Bi7780. If requested, this number must be provided to the telephone
    Plug one end of a telephone cable into the radio base port          problems, clean the golden contact under the terminal                            company.

         , and plug the other end of the cable in the phone.            with a damp cloth.                                                               A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the
                                                                                                                                                         applicable FCC Part 68 rules and requirements adopted by the ACTA.

    • PERIPHERAL/HOST CONNECTION                                      • Do not scratch or scrape the surface of the contacts.                            The Ringer Equivalence Number (REN) is used to determine the number of devices that may be connected to a
                                                                                                                                                         telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming
                                                                                                                                                         call. In most but not all areas, the sum of RENs should not exceed five (5). To be certain of the number of devices that
    Unplug the i7780 base. Connect the serial cable to the       7.   Technical specifications:                                                          may be connected to a line, as determined by the total RENs, contact the local telephone company.
                                                                                                                                                         If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the
    base port marked COM2 or COM1/3. Plug the other end                                                                                                  equipment until the problem is resolved.
                                                                      The i7780 system uses Bluetooth technology:
                                                                                                                                                                                                                                                                                     Ingenico 7780
                                                                                                                                                         If your home has specially wired alarm equipment connected to the telephone line, ensure the installation of this I7780
    of the serial cable to the device (PC, check reader etc.).                                                                                           does not disable your alarm equipment. If you have questions about what will disable alarm equipment, consult your
    For detailed instructions, ask the equipment supplier.            Type...........................20 dBm hopping frequency                            telephone company or a qualified installer.

    • POWER CONNECTION                                                Bandwidth .................ISM 2.45 GHz                                            Industry Canada Warning:
                                                                                                                                                         NOTICE: This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is
    Plug the power adapter radial jack into the i7780 base            Emitting power ..........≤ 100mW (20dBm)
                                                                                                                                                                                                                                                                                     Installation Guide
                                                                                                                                                         confirmed by the registration number. The abbreviation, IC, before the registration number signifies that registration
                                                                                                                                                         was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met.
    port marked           . The green light on the front right        Range.........................≈ 200 meters (open field)                            It does not imply that Industry Canada approved the equipment.
                                                                                                                                                         NOTICE: The Ringer Equivalence Number (REN) for this terminal equipment is <0.1>. The REN assigned to each
    hand side of the base indicates the power is on.                  The power supply:                                                                  terminal equipment provides an indication of the maximum number of terminals allowed to be connected to a telephone
                                                                                                                                                         interface. The termination on an interface may consist of any combination of devices subject only to the requirement
    Attach the cable securing plate and fix it with a screw.
                                                                      • INPUT ................AC 120V 60Hz                                               that the sum of the Ringer Equivalence Numbers of all the devices does not exceed five.
                                                                                                                                                         NOTICE: To prevent radio interference to the licensed service, this device is intended to be operated indoors and away
                                                                      • OUTPUT . DC 18V 0.9A 16.2VA                                                      from windows to provide maximum shielding. Equipment (or its transmit antenna) that is installed outdoors is subject to
                                                                                                                                                         licensing.

                                                                      Thermal Paper Specification:
                                                                      • Single ply thermal sensitive – POS or facsimile grade.
3.6. Changing the printer paper:                                      • Basis Weight: (lb/rm 17 ins. X 22 ins. - 500) --- 14.5 ± 5%
                                                                                                                                                                                           Ingenico Inc.
    When the coloured stripe on the paper appears, replace                                                                     (GSM) --- 55 ± 5%                              1003 Mansell Road, Atlanta, GA 30076
    the paper:                                                        • Caliper ............................ 2.4 ± 0.2 Mils or 60 ± 5 Microns                             Tel: (770) 594 – 6000    Fax: (770) 594 – 6003
    1. Remove the i7780 from the base and wait till it turns          • Brightness........................................................... Min. 85%                                        www.ingenico-us.com
        off, do not touch the printer parts, they can be very         • Smoothness (Bekk Minimum) ....................................300 s
        hot. Be aware of the sharp paper cutter.                                                                                                                                 Ingenico Canada Ltd.
                                                                      • Roll Width ................... 2.28 ± 0.040 in (58 mm ± 1.0 mm)
    2. Push the button on the paper compartment cover                                                                                                            79 Torbarrie Road, Toronto, Ontario, Canada, M3L 1G5
                                                                      • Roll Diameter .......................... 1.97 in (50 mm) maximum
        toward the back and lift the cover.                                                                                                                          Tel: (416) 245 – 6700    Fax: (416) 245 – 6701
                                                                      • Roll Core ID ............................. 0.500 in (13 mm) nominal                                                                                                                                                        DIV750026A
    3. Remove the empty paper roll and insert the new roll.                                                                                                                                   www.ingenico-ca.com
                                                                      • Roll Core OD............................ 0.625 in (16 mm) nominal


1.   Ingenico 7780 description:                                          The card has to be swiped at uniform speed and pressure,                8. The Ethernet cable (optional, with Ethernet module only).                 Always charge the battery at the room temperature.
                                                                         ensuring that the card remains in contact with the bottom of            9. The cable securing plate and a screw (optional, with the                  Charge the battery for 3 hours when it is used the first time.
      The i7780 is a portable (Bluetooth technology) point of            the track throughout the entire swipe action.                                base only).                                                             Full charging time after the first time is 2 hours. A new
      sale electronic payment terminal designed to process          1.4. Smart Card Reader:                                                      10. The holster (optional).                                                  battery will benefit from an initial "conditioning". The first 3
      debit, credit and smart card purchases. It is highly               Insert the smart card horizontally into the slot on the front of        11. This installation guide.                                                 times the battery is used, allow the battery to fully discharge
      secured, EMV level 1and 2 certified.                               the i7780, the microchip facing up, and leave it in the reader                                                                                       and then charge it to its full capacity.
      The i7780 communicates with the acquirer through its               throughout the transaction.
                                                                                                                                            3.   Installation procedure:
      base via the telephone and/or Ethernet network. The                The i7780 has EMV level 1&2 approvals and complies                      Place the i7780 base on a clear, flat surface near an electrical
                                                                                                                                                                                                                          3.2. Installing the Battery:
      hand-held terminal and the base communicate through                                                                                                                                                                     Leave the i7780 handheld terminal off its base and wait until
                                                                         with the ISO 7816, Sync and Async T=1 & T=0.                            and telephone sockets. The ideal location is in the center of
      the Bluetooth link, or via direct contact. A network can                                                                                                                                                                it turns itself off before handling the battery pack.
                                                                    1.5. Printer:                                                                the zone to be covered with a large open area around. The
      be set up, with one base managing up to 7 terminals at the                                                                                                                                                              Hold the battery with the connectors facing downwards, do
                                                                         The i7780 integrates a quiet, high speed, “easy-load” style             antenna is inside, on the left side of the base.
      same time. Various peripherals can be connected to the                                                                                                                                                                  not touch the contacts on the battery or the i7780.
                                                                         thermal printer with graphics capability.                               The i7780 hand held and the base must be protected from
      base through its RS-232 ports.
                                                                    1.6. Battery:                                                                high temperature, vibrations, dust, dampness and
                                                        Paper                                                                                    electromagnetic radiation (computer screen, microwave
     Navigation keys                            Compartment              Rechargeable and easily replaceable Ni-MH or Li-Ion battery
                                                                         pack.                                                                   oven, anti-theft barrier etc.). Equipment such as cordless and
                                                                                                                                                 cellular phones can emit harmonics that could disturb the
                                                    Magnetic        1.7. SAM Connectors:
                                                                                                                                                 terminal at 2.45 GHz.
                                                  Stripe Card            Three SAM card connectors are located on the bottom of the
                                                                                                                                                 Do not place the base near a great vertical metal plane (doors
                                                       Reader            i7780. The SAM (Secure Access Module) supports
     Paper                                                                                                                                       of refrigerator, large home appliances, vending machines).
                                                                         smart card chips necessary for applications such as                     Ensure the base or the terminal is more than 3 m (around 10
     Feed Key
                                                     CANCEL              loyalty.                                                                feet) from any microwave oven in use.
                                                     Key            1.8. The Base                                                                Do not place the hand held terminal on a metal surface.                      Insert the two plastic teeth in the gaps on the i7780 case,
                                                                         The i7780 communicates with its base via Bluetooth radio                Do not put your hand under the printer during                                place the battery in the cavity and press the handle until a
                                                   CORR Key                                                                                                                                                                   click is heard.
                                                                         link, or through the contacts (connect mode) which is useful            communication, as the range is greatly reduced.
                                                                         when loading large amounts of data, or when a Bluetooth                 If there are several radio bases installed, position them at
     Smart Card                                    ENTER Key
                                                                         link is unavailable.
                                                                                                                                                                                                                          3.3. SAM Installation:
                                                                                                                                                 least 2 meters (around 6.5 feet) from each other.                            Wait till the i7780 turns off and remove its battery (do not
     Reader                                                              The i7780 works with either radio base or versatile base. The
                                               Green Power                                                                                       Ensure that the terminal is seated securely on the base.                     touch the contacts on the battery or the i7780). Unlock the
                                                                         versatile base has a Plug-It slot to add a Plug-It module with
                                               Indicator Light                                                                                                                                                                SAM connector by sliding the metallic latch in the direction
     Base Contacts                                                       additional communication port.                                          Operating temperature ................................+5°C to +40°C          of the OPEN arrow. Lift the SAM cover upward and insert
                                                                         The base station recharges the battery pack and includes the            Humidity ........................ 20% to 90% without condensation            the chip as shown on the picture below. Swing the cover
1.1. Display:                                                            following communication ports:                                          Storage temperature ....................................-10°C to +60°C       down and slide the latch into locked position (the LOCK
     A 4 line x 16 character LCD graphic display, with a                 - COM2 and COM1/3:
                                                                         Two RS-232 serial communication links for customer                 3.1. Battery Set up and Charging:                                                 arrow). Put the battery back in the i7780 handheld.
     back light.
                                                                         applications download and for the communication with                    The i7780 is supplied with a removable rechargeable NiMH
1.2. Keypad:                                                             external peripherals (speed 300 to 115200 bps). The                     or Li-Ion battery. Only use the battery pack supplied with
     18 keys, with a back light. The special function keys are:          COM1/3 provides power for external devices.                             your terminal.
     • Programmable function keys <F1>, <F2> and <F3>                    - DIAL LINE port:                                                       i7780 battery is built with circuitry for intelligent battery
       for navigation and access to various i7780 functions              A V34 / 33600 bps (asynch. and synchr.) modem that                      management. To charge the battery, place the handheld on
       and the system and application menus.                             supports fast connect and busy line detection.                          the base (the base must be powered up).
     • Paper Feed key is used for a printer paper feed (20mm)            - TELEPHONE port (on radio base only):                                  Ensure that the terminal is seated securely on the base.
       The green <ENTER> key confirms the data entered or                The telephone port allows sharing of the telephone line with            Use the power adapter supplied with the i7780. Many
       displayed. It also powers on the i7780.                           other devices such as a fax machine or telephone.                       adapters can appear similar and will plug into the i7780 base
     • The red <CAN> key cancels the current function and                - ETHERNET port (on versatile base only):                               but will not work properly causing erratic behavior, poor                3.4. Changing The Plug-It Module:
       returns the terminal to the idle state. It also powers off        The Ethernet port allows the i7780 to connect to a local                charging or even damage to the unit.                                         1.   Turn off the versatile base
       the i7780 if it is not docked on the base.                        network.                                                                Note that the battery will recharge only if necessary.                       2.   Remove the cable from Plug-It module.
     • The yellow <CORR> key corrects invalid data entry.                                                                                        Furthermore, the battery has internal temperature control so                 3.   Remove the screw using Philips screwdriver.
     • The blue <ADMIN> key is used to access the terminal          2.   Ingenico 7780 Packaging Content:                                        it never exceeds 50°C.                                                       4.   Take the Plug-It module out.
       administration function menu.                                                                                                             The i7780 with a fully charged battery can execute up to 200                 5.   Put in the new Plug-It module and secure it with a screw.
                                                                         1.   The I7780 hand held terminal.                                      transactions (depending on the ticket size and transaction
1.3. Magnetic Stripe Card Reader:                                        2.   The battery pack.                                                  duration).
     i7780 features a bi-directional reader capable of reading           3.   Thermal printer paper, one roll.                                   The battery status is updated on the handheld display:
     tracks 1 and 2 simultaneously. The reader is located on             4.   The base (optional versatile, radio or charging).
     the right-hand side. The card can be swiped from the                5.   The plug-it module (optional, with the versatile base).                          1 bar represents 25 % of full capacity,
     bottom to the top, or from the top to the bottom. The               6.   The power supply (optional, with the base only).                                 2 bars represent 50 % of full capacity,
     magnetic stripe on the card has to face down and point              7.   The phone cable (optional, with the radio or versatile                           3 bars represent 75 % of full capacity,